}

Calibration Of Laboratory Test Equipment And Measuring Devices For Two Years, Numaligarh Refinery Limited-Assam

Numaligarh Refinery Limited has published Calibration Of Laboratory Test Equipment And Measuring Devices For Two Years. Submission Date for this Tender is 15-07-2021. Calibration Service Tenders in Numaligarh Refinery Limited Assam. Bidders can get complete Tender details and download the document.




Tender Notice

28315403
Corrigendum : Calibration Of Laboratory Test Equipment And Measuring Devices For Two Years
Tender
Indian
Assam
Numaligarh Refinery Limited
15-07-2021

Tender Details

Calibration Of Laboratory Test Equipment And Measuring Devices For Two Years - 1 Calibration Charges For First Year 2 Calibration Of Temp Of Oven 3 Calibration Of Oxidation Stability Bath 4 Calibration Of Microcarbon Residue Test One Temperature 5 Calibration Of Gum Test Apparatus 6 Calibration Of Fia Apparatus ( Scale ) 7 Calibration Of Electronic Balance 8 Calibration Of Copper Corrosion Bath 9 Calibration Of Muffle Furnace 10 Calibration Of Incubator 11 Calibration Of Low Temperature Bath 12 Oxidation Stability Bath For Diesel 13 Calibration Of Probe Simulator 14 Calibration Of Stop Watch 15 Calibration Of Weight Box 16 Calibration Of Hygrometer @ 50%, 70% And 90% 17 Calibration Of Silver Corrosion Bath 18 Calibration Of Barometer 19 Thermometer No Ip 1C ( Pour Point ) 20 Thermometer No Ip 5C ( D86 Low ) 21 Thermometer No Ip 6C 22 Thermometer No Ip 14C ( Freezing Point ) 23 Thermometer No Ip 15C ( Pensky Martens Low ) 24 Thermometer No Ip 17C ( Wax Melting Point ) 25 Thermometer No Ip 21C ( Aniline Point ) 26 Thermometer No Ip 23C ( Reid Vapour Pressure ) Any Thre Points Within The Range 27 Thermometer No Ip 39C ( Density ) 28 Thermometer No Ip 63C ( Petroleum Melting Point ) 29 Thermometer No Ip 64C ( Density Wide Range ) 30 Thermometer No Ip 72C ( Oil In Wax ) 31 Thermometer No Ip 74C ( Able Oil Cup Wide Range ) 32 Thermometer No Ip 75C ( Able Water Bath ) 33 Thermometer No Ip 92C ( K Visc 40 Deg C ) 34 Thermometer No Astm 99C ( Weathering ) 35 Hydrmeter ( 0.600-0.650 ) 36 Hydrmeter ( 0.650-0.700 ) 37 Hydrmeter ( 0.700-0.750 ) Any Thre Points Within The Range 38 Hydrmeter ( 0.750-0.800 ) 39 Hydrmeter ( 0.800-0.850 ) 40 Hydrmeter ( 0.850-0.900 ) 41 Hydrmeter ( 0.900-0.950 ) 42 Hydrmeter L - 50 ( 0.950-1.00 ) 43 Viscometer Size 50 44 Viscometer Size 75 45 Viscometer Size 100 46 Viscometer Size 150 47 Viscometer Size 200 @ 40°C Within 2.0 Cst, 5.0 48 Pipette Transfer1 Ml 49 Pipette Transfer 2 Ml 50 Pipette Transfer 5 Ml 51 Pipette Transfer 10 Ml 52 Pipette Transfer 20 Ml 53 Pipette Transfer 25 Ml 54 Measuring Pipette 5 Ml 55 Measuring Pipette 10 Ml 56 Burette 25 Ml 57 Cylinder 100 Ml 58 Pressure Gauge Fia Apparatus 59 Pressure Gauge Oxidation Stability Bath 60 Pressure Gauge Gum Test Appratus 61 Pressure Gauge Reid Vapor Pressure 62 Volumetric Flask 500 Ml 63 Volumetric Flask 250 Ml 64 Volumetric Flask 50 Ml 65 Volumetric Flask 25 Ml 66 Calibration Charges For Second Year 67 Calibration Of Temp Of Oven 68 Calibration Of Oxidation Stability Bath 69 Calibration Of Microcarbon Residue Test One Temperature 70 Calibration Of Gum Test Apparatus 71 Calibration Of Fia Apparatus ( Scale ) 72 Calibration Of Electronic Balance 73 Calibration Of Copper Corrosion Bath 74 Calibration Of Muffle Furnace 75 Calibration Of Incubator 76 Calibration Of Low Temperature Bath 77 Oxidation Stability Bath For Diesel 78 Calibration Of Probe Simulator 79 Calibration Of Stop Watch 80 Calibration Of Weight Box 81 Calibration Of Hygrometer @ 50%, 70% And 90% 82 Calibration Of Silver Corrosion Bath 83 Calibration Of Barometer 84 Thermometer No Ip 1C ( Pour Point ) 85 Thermometer No Ip 5C ( D86 Low ) 86 Thermometer No Ip 6C 87 Thermometer No Ip 14C ( Freezing Point ) 88 Thermometer No Ip 15C ( Pensky Martens Low ) 89 Thermometer No Ip 17C ( Wax Melting Point ) 90 Thermometer No Ip 21C ( Aniline Point ) 91 Thermometer No Ip 23C ( Reid Vapour Pressure ) Any Thre Points Within The Range 92 Thermometer No Ip 39C ( Density ) 93 Thermometer No Ip 63C ( Petroleum Melting Point ) 94 Thermometer No Ip 64C ( Density Wide Range ) 95 Thermometer No Ip 72C ( Oil In Wax ) 96 Thermometer No Ip 74C ( Able Oil Cup Wide Range ) 97 Thermometer No Ip 75C ( Able Water Bath ) 98 Thermometer No Ip 92C ( K Visc 40 Deg C ) 99 Thermometer No Astm 99C ( Weathering ) 100 Hydrmeter ( 0.600-0.650 ) 101 Hydrmeter ( 0.650-0.700 ) 102 Hydrmeter ( 0.700-0.750 ) Any Thre Points Within The Range 103 Hydrmeter ( 0.750-0.800 ) 104 Hydrmeter ( 0.800-0.850 ) 105 Hydrmeter ( 0.850-0.900 ) 106 Hydrmeter ( 0.900-0.950 ) 107 Hydrmeter L - 50 ( 0.950-1.00 ) 108 Viscometer Size 50 109 Viscometer Size 75 110 Viscometer Size 100 111 Viscometer Size 150 112 Viscometer Size 200 @ 40°C Within 2.0 Cst, 5.0 113 Pipette Transfer1 Ml 114 Pipette Transfer 2 Ml 115 Pipette Transfer 5 Ml 116 Pipette Transfer 10 Ml 117 Pipette Transfer 20 Ml 118 Pipette Transfer 25 Ml 119 Measuring Pipette 5 Ml 120 Measuring Pipette 10 Ml 121 Burette 25 Ml 122 Cylinder 100 Ml 123 Pressure Gauge Fia Apparatus 124 Pressure Gauge Oxidation Stability Bath 125 Pressure Gauge Gum Test Appratus 126 Pressure Gauge Reid Vapor Pressure 127 Volumetric Flask 500 Ml 128 Volumetric Flask 250 Ml 129 Volumetric Flask 50 Ml 130 Volumetric Flask 25 Ml

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 09-07-2021 Technical details Technical Bid 15-07-2021

Key Value

Document Fees
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail