| 1 | 1 | Supply & Replacement of Surface mounted LED Downlighter of 15/18 Watt with lumens of more then 1650 ,CCT more then 4500k , Die- Cast Aluminium housing ,Energy Efficient electronic driver with input voltage of 220-240V, 50/60Hz, High Surge Protection : 2.5KV,THD <10% & PF>0.95 ,Efficacy more than 100 lumens/watt, Confirmed to IEC Safety Standard(IEC 60598, IEC 61347) with certificates of LM79 & LM80 , Optics :Polycarbonate diffuser lens for better light distribution.i/c less credit for dismantle material . | | 75 | Each |
|---|
| 2 | 2 | Supply & Replacement of recess mounted LED Downlighter of 15/18 Watt of 150mm dia ,with lumens of more then 1650 ,CCT more then 4500k , Die- Cast Aluminium housing ,Energy Efficient electronic driver with input voltage of 220-240V, 50/60Hz, High Surge Protection : 2.5KV,THD <10% & PF>0.95 ,Efficacy more than 100 lumens/watt Confirmed to IEC Safety Standard(IEC 60598, IEC 61347) with certificates of LM79 & LM80 , Optics :Polycarbonate diffuser lens for better light distribution.i/c less credit for dismantle material | | 100 | Each |
|---|
| 3 | 3 | Supply & Replacement of LED Post Top decorative type with 360 degree view of 35/45 Watt with lumens of more then 3000 ,CCT 5500K , Die- Cast Aluminium housing With Top cover HET PPMA Clear Diffuser having IP 65 protection for complete fixture ,with input voltage of 220-240V, 50/60Hz, THD <10% & PF>0.95, Confirmed to IEC Safety Standard(IEC 60598, IEC 61347), with certificates of LM79 & LM80 i/c credit for dismentaled material. | | 45 | Each |
|---|
| 4 | 4 | Supply & Replacement of Storage Water Cooler Storage Capacity (in litre) 80,Power Consumption 625 Watt +/- 10 %,Current 3.2 A +/- 10 %,Cooling Capacity 60 LPH, Maximum Water Input Pressure 2.0 kg/mm square ,Minimum Water Input Pressure 0.4 kg/mm square,Operating Power Supply 230 +/- 10% V AC,50Hz,1 PH, Operating Temperature 15 to 45 Degree C , Recommended Maximum Water Flow 1.5 LPM, Second Stage Of Purification Carbon filtration, Number Of Normal Water Faucets 1 ,Third Stage Of Purification UV filtration , Net Weight 65 kg, Front Panel Material SS 304 , Storage Tank Material SS 304, First Stage Of Purification Sediment filtration, Refrigerant R134a , Side And Back Panel Material SS 304 , Dimensions W X D X H 660 x 480 x 1355 mm, Number Of Cold Water Faucets 1, Thermal Insulation For Storage Tank PUF, Number Of Filtration Stage 3, Number Of Purifier Circuit 2, Operating Voltage 180 - 250 V.i/c credit for dismentaled material. | | 3 | Each |
|---|
| 5 | 5 | Taking out & Lowering of upto 5 HP Submersible P/set along with G.I pipe from well / underground tank with the help of chain pully block and tripod etc. as reqd. | | 3 | P/Job |
|---|
| 6 | 6 | Dismantling of Submersible / Mono submersible motor i/c cutting the burnt winding wire & rewinding the same with PVC insulated copper winding wire etc as reqd. | | | |
|---|
| 7 | 6.01 | 5HP | | 1 | P/Job |
|---|
| 8 | 6.02 | 10 HP | | 1 | P/Job |
|---|
| 9 | 6.03 | 15HP | | 1 | P/Job |
|---|
| 10 | 7 | Supplying & Laying of one number PVC insulated and PVC sheathed / XLPE aluminum armoured power cable of 1.1 KV grade of following size in the existing masonry open duct as required etc as reqd. | | | |
|---|
| 11 | 7.01 | 2 X 10 sq. mm | | 700 | P/Mtr |
|---|
| 12 | 7.02 | 2 X 16 sq. mm | | 350 | P/Mtr |
|---|
| 13 | 7.03 | 3.5 x 70 sq. mm | | 200 | P/Mtr |
|---|
| 14 | 8 | Supplying and fixing weather proof, hot press mouled smc junction box of size 333 x 233 x 120 mm outside size and 300 x 200 x 105 mm of inside size (side hinged door box.) complete with 1 No.SPMCB of 10KA breaking capcity and 6A rating, din bar, 2 No. aluminium busbar fixed on 4 No. suitable insulator and hole for cable entry complete with gasket etc. to be fixed direct on wall or pole complete with conection i/c dismantaling of existing and credit for rebate etc. as required. | | 40 | Each |
|---|
| 15 | 9 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. | | | |
|---|
| 16 | 9.01 | 3½ X 70 sq. mm | | 4 | Each |
|---|
| 17 | 10 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required | | 1000 | P/Mtr |
|---|
| 18 | 11 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. | | | |
|---|
| 19 | 11.01 | 2 X 10 sq. mm | | 10 | Each |
|---|
| 20 | 11.02 | 2 X 16 sq. mm | | 6 | Each |
|---|
| 21 | 12 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paint of required shade complete as required | | | |
|---|
| 22 | 12.01 | 80 mm dia | | 20 | P/Mtr |
|---|
| 23 | 12.02 | 100 mm dia | | 20 | P/Mtr |
|---|
| 24 | 13 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : | | | |
|---|
| 25 | 13.01 | 80mm dia | | 4 | Each |
|---|
| 26 | 14 | Supply & replacement of mosquito/Dengue free NCDC approved desert coolers of 20\" size made out of GI body of capacity 4000 cum/hr complete set etc as reqd.i/c less credit to dismantaled material. | | 25 | Nos |
|---|
| 27 | 15 | Supplying and fixing of following sizes of FRLS PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, in the existing surface/recessed/Open / Channel etc as required. | | | |
|---|
| 28 | 15.01 | 3 Core 1.5 Sq. mm | | 60 | P/Mtr |
|---|
| 29 | 16 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | | | |
|---|
| 30 | 16.01 | Group B | | 125 | Each |
|---|
| 31 | 17 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. | | | |
|---|
| 32 | 17.01 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | | 400 | P/Mtr |
|---|
| 33 | 18 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steeI / PVC conduit as required. | | | |
|---|
| 34 | 18.01 | 3 x 1.5 sq. mm | | 600 | P/Mtr |
|---|
| 35 | 19 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. | | | |
|---|
| 36 | 19.01 | 3 Module (100 mmX75 mm) | | 150 | Each |
|---|
| 37 | 19.02 | 8 Module (125 mmX125 mm) | | 80 | Each |
|---|
| 38 | 20 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | | | |
|---|
| 39 | 20.01 | 5/6 A switch | | 300 | Each |
|---|
| 40 | 20.02 | 15/16 A switch | | 250 | Each |
|---|
| 41 | 20.03 | 3 pin 5/6 A socket outlet | | 100 | Each |
|---|
| 42 | 20.04 | 6 pin 15/16 A socket outlet | | 100 | Each |
|---|
| 43 | 21 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar,earth bar, dinbar inter-connections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) | | | |
|---|
| 44 | 21.01 | 16 way, Double door | | 2 | Each |
|---|
| 45 | 22 | Motor Control Centre Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated with reinforcement of suitable size upto 300 mm deep made out of M.S. Sheet 2mm. Thick (14 SWG) duly compartmentalised having 4 strip Al. busbar of minimum 200amps capacity double door with locking arrangement for protection from rain, dust, duly fixed on M.S. angle iron frame work of size 50 mm X 50 mm X 6 mm (NS) 50 cm long legs grouted in cement concrete 1:2:4 (1 cement 2 sand :4 stone aggregate 20 mm) on underground tank Surface/ Ground and having following accessories mounted inside the cubical panel i/c connection, inter connection with aluminum thimbles, earth studs duly painted with one coat of red oxide & two coats of superior quality enamel paint complete etc. as reqd i/c supplying and fixing following accessories as per item i/c control wiring. Cable gland plates shall be provided on top as well as at the bottom of the panels. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. | | | |
|---|
| 46 | 22.01 | Incoming | | | |
|---|
| 47 | 22.02 | 200 amps 25KA TPN MCCB with the following accessories | | | |
|---|
| 48 | 22.03 | a.) 0-500 volts 96 x 96 mm square electronic voltmeter with selector switch shall be protected by 2 amps TP MCB. 1 Set | | | |
|---|
| 49 | 22.04 | b.) 0-100 amps 96 x 96 mm square electronic ammeter with selector switch and 100./5 amps 10 VA CL:1 CTs. 1 Set | | | |
|---|
| 50 | 22.05 | c) Phase indicating lamps shall be protected by 2 amp SP MCB 3 Sets | | | |
|---|
| 51 | 22.06 | BusBar | | | |
|---|
| 52 | 22.07 | 300amps TPN (15 KA) Aluminim bus bar with heat shrinkable insulation sleeves. | | | |
|---|
| 53 | 22.08 | Required Nos of required capacity TPN MCB for direct on line starter/star delta starters and out going feeders to all the pumps (including standbys). Each compartment shall contain auto / manual selector switch and indicating lamp with MCB’s for ‘ON/OFF/TRIP’ status of motor . | | | |
|---|
| 54 | 22.09 | Spare MCB's of the following capacites: 32 amps TPN MCB's 3 Nos . | | | |
|---|
| 55 | 22.1 | Notes:- All MCCBs / MCBs shall be of 25KA breaking capacity and suitable for motor duty application. | | | |
|---|
| 56 | 22.11 | All motor starters shall be provided with Automatic level controller . | | | |
|---|
| 57 | 22.12 | (2+1) NOS DOL starters shall be used for mototrs Of 10HP and (2+1) Nos Star-Delta Starters for 15HP motors. | | | |
|---|
| 58 | 22.13 | Provision shall be made for providing potential free contacts to all Pump starters.i/c less credit for dismantle material | | 1 | Each |
|---|