Gek-33/2021-22 Repair Maint Of Lt Cables Poles Earthings And Other Connected Works At Subathu Under Ge Kasauli
Tender Overview
Project Description
Gek-33/2021-22 Repair Maint Of Lt Cables Poles Earthings And Other Connected Works At Subathu Under Ge Kasauli
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-Jul-2021 | AMENDEMENTS TO TENDER DOCUMENTS AND UPLOAD REVISED BOQ | BOQ | 14-Jul-2021 |
| 2 | 14-Jul-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-Jul-2021 |
| 3 | 05-Jul-2021 | AMENDEMENT TO DATE | Date | 14-Jul-2021 |
BOQ
| Name of Work: REPAIR/ MAINT OF LT CABLES, POLES, EARTHINGS AND OTHER CONNECTED WORKS AT SUBATHU UNDER GE KASAULI. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 0.01 | Schedule 'A' Section - I | |||
| 2 | 1 | Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles/laying of under ground cables etc and getting out in hard/dense soil complete all as specified and as directed. | 50 | Cum | |
| 3 | 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed. | 40 | Cum | |
| 4 | 3 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. | 10 | Cum | |
| 5 | 4 | M & L Precast cable cover ,class L V ,Type I, flat ,size 250mm x150 mm x40mm the cable for cable protection all as specified and directed. | 1500 | Each | |
| 6 | 5 | Supply, laying, testing and commissioning of cable LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sq. Mm 3.5 core confirming to IS specification including taking out existing unserviceable cable complete all as specified and as directed. | 100 | RM | |
| 7 | 6 | Supply, laying, testing and commissioning of cable LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 sq. Mm 3.5 core confirming to IS specification including taking out existing unserviceable cable complete all as specified and as directed. | 100 | RM | |
| 8 | 7 | Supply, laying, testing and commissioning of cable LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 sq. Mm 3.5 core confirming to IS specification including taking out existing unserviceable cable complete all as specified and as directed. | 100 | RM | |
| 9 | 8 | S&F double wall corrugated HDPE duct pipe 63 mm outer dia confirming to IS: 14930 (Part-II) of approved colour with fittings for cable protection complete all as specified and as directed. | 50 | RM | |
| 10 | 9 | S&F GI tubing 40mm bore light grade for cable protection on pole / trench incl dismentling taking down unserviceable one. | 8 | RM | |
| 11 | 10 | Supply and erecting steel tubular swaged type pole 410 SP 31 (.9 mtr long) single swan neck type including foundation complete with cast iron /MS base plate of size 300mmx300mmx6mm continously welded at the centre of the pole and MS cap at the top of the pole all as specified including factory painted with two coats of black bituminous paint internally throughout and externally for embedded portion and applying of two coats of aluminium paint over a coat of red oxide primer above 1.5 mtr from GL and making of size 30 cm wide of black and white synthetic enamel paint alternately upto 1.5 m from ground level complete all as specified. | 4 | Each | |
| 12 | 11 | S&F cradle hexagonal /rectangular fabricated with galvanised steel wire 4mm dia including dismentling taking out unsv Cradle goard from Pole. | 0.5 | Qtl | |
| 13 | 12 | PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed. | 2 | Cum | |
| 14 | 13 | Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below notmal ground level, connected to galvanised iron earth strip 32x6mm upto test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including light grade GI watering pipe 20mm bore with funnel wire mesh and medium grade GI wire protection pipe 40mm bore up to main board completew as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete ass as specified and testing on completion complete ass as specified and directed. \nNote - The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 20mm GI pipe (light grade) for watering 40mm GI protection pipe (medium grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. | 10 | Each Set | |
| 15 | 14 | Supply and fixing of shock treatment chart as per E-in-C's pattern size 2 feet x 4 feet aluminium board with alluminium frame & glass with houging aggrements all as directed. | 6 | Each | |
| 16 | 15 | Supply & Laying rubber mat size 1 mtr x 2 mtr x 10mm thickness , suitabe for electric supply 1100 Volts. | 10 | Each | |
| 17 | 16 | M&L for Painting of steel tubular pole 9.0 metre long, by applying two coat of aluminium paint after scraping / brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and yellow enameled paint (30 Cms each). Pole Nos will be written on pole by black paint in white circle of 150mm dia, complete, all as specified and directed. \nNote:- Only one coat will be applied at one time and payment at 50% of coated rate to be applied at the first time of first coat. Second coat is to be done more than 30 days after first coat. | 100 | Each | |
| 18 | 17 | M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in single red color and fixed with MS clamps , bolts and nuts of approved size, for 20x15mm size. | 100 | Each | |
| 19 | 18 | M&L for anti-climbing device, spikes type fabricated out of MS bars (round,square and flat) including nuts,bolts,washer and welding in two halves made to shape to suit the cross section of the pole. | 0.5 | Qtl | |
| 20 | 19 | Supply and fixing in repairs straight through (Heat shrinkable) joint kit suitable for 1.1 KV UG XLPE cable of size 70 to 150 Sqmm 3.5 core. | 2 | Each | |
| 21 | 20 | Supply and fixing in repairs straight through (Heat shrinkable) joint kit suitable for 1.1 KV UG XLPE cable of size 185 to 300 Sqmm 3.5 core. | 1 | Each | |
| 22 | 21 | Supply and fixing in repairs straight through (Heat shrinkable) joint kit suitable for 1.1 KV UG XLPE cable of size 630 Sqmm 3.5 core. | 1 | Each | |
| 23 | 22 | Supply and fixing &replacement Time switch astro type 1 Phase - 2W 2 Channel, Base/DIN with necessary electric connection including setting the time and other specification as per directed. | 3 | Each | |
| 24 | 23 | Supply & Fixing and replacement Aluminium Thimbles/Lugs in existing panel and DB box in verious sizes 10/16/25/35/50/70/95/120/150/220/240/300/400/630sqmm | 300 | Each | |
| 25 | 24 | Repair/Overhauling of air CIRCUIT BREAKERS by replacing stationary and coming contacts, flexible cooper chord, GI nuts, bolts etc incliding alignment for smooth functioning from ground level all as required at site and as directed. | 5 | Job | |
| 26 | 25 | S&F in repair on existing location including taking out of existing MCCBs of following capacity :- | |||
| 27 | 25.01 | (a) MCCB 415 volts 200 Amps 04 pole 36 KA (ICU= 50% ICS), | 1 | Each | |
| 28 | 25.02 | (b) MCCB 415 volts 100 Amps 04 pole 25 KA (ICU= 50% ICS) | 1 | Each | |
| 29 | 25.03 | (c) MCCB 415 volts 63 Amps 04 pole 25 KA (ICU= 50% ICS) | 1 | Each | |
| 30 | 26 | Taking down old UNSV Strret light, any type and size from the poles and Supply and fixing inreplacement of street/security light with'CUB' LED light 35 watt presure die cast housing with epoxy power coated dark graphite grey colour finish. polycarbonate cover with individual LED lenses , inbuilt electronic driver and providing necessary connections with 2 core 2.5 Sqmm stranded PVC insulated and PVC sheathed copper conductor upto 3 metre length . | 45 | Each | |
| 31 | 27 | Taking down old unserviceable LED street light fitting of any size/capacity from exsting location i.e from LT pole/Bldg /Store etc and opening up and removing old unserviceable LED Driver /Surge protection device and fixing new driver /SPD and replaceing connection if required to making the street light is serviceable connection and re- fixing the same on existing location (Note:-LED Driver/SPD will be measured and paid seprately) | |||
| 32 | 28 | S&F in repair LED current driver adopter AC 85-265V to DC 24-38 V IP 65 waterproof LED Street light capacity 35 W | 20 | Each | |
| 33 | 29 | S&F in repair LED current driver adopter AC 85-265V to DC 24-38 V IP 65 waterproof LED Street light capacity 45 W | 20 | Each | |
| 34 | 30 | S&F in repair LED current driver adopter AC 85-265V to DC 24-38 V IP 65 waterproof LED Street light capacity 60 W | 20 | Each | |
| 35 | 31 | S&F in repair LED current driver adopter AC 85-265V to DC 24-38 V IP 65 waterproof LED Street light capacity 90 W | 10 | Each | |
| 36 | 32 | S&F in repair on existing location including taking out of existing LED Street light surge protection device for additional protectionof following capacity :- 30w,45w,60W,90W | 10 | Each | |
| 37 | 33 | Supply and fixing in replacement maintenance free dry type battery 12 volts, 180 AH. | 2 | Each | |
| 38 | 34 | S&F in replacement change over switch 125 Amps four pole 415 volts complete | 2 | Each | |
| 39 | 35 | -do- but capacity 200 amps four pole 415 volts. complete | 2 | Each | |
| 40 | 36 | Supply, installing, testing & commissioning of LT sheet metal enclosure outdoor type dust & Vermin proof (duly painted with powder coating 6 tank process). Cable lugs are to be used to terminate cables/wires, and necessary connections all as directed, self supporting fabricated out of CRCA steel sheet 3.15 mm thick, of size ( 1000x700x350 )with base mounted on angle iron frame (40x40x4 mm) incldg 4 Legs 60 cms long made of angle iron (40x40x4 mm) grouted 30 cms below ground with PCC 1:2:4, cubicle type comprising of following:-\n(a) Onload Changeover Switch 100 Amps, 4 pole - 01 Nos. \n(b) Digital Volt meter, AC, single phase 0-500 volt 48x96 mm, 3 1/2 digit, -03 Nos. \n(c) Digital Amp meter, AC, 0-100 Amps 48x96 mm, 3 1/2 digit incldg CT (100 : 5), -03 Nos. \n(d) Digital frequency meter, AC, single phase 50 Hz, 48x96 mm, 3 1/2 digit, -01 Nos. | 1 | Each Job | |
| 41 | 37 | Amount of credit of Rs. 18270.00 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents