Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Medicine For 2021 22
Tender Overview
Project Description
Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Medicine For 2021 22 - 1.001 Sterile Suction Catheter With Mucus Extractor / Trap 1.002 Catheter Mount For Ventilator 1.003 T-Piece Connector ( With Corrugated Side Tube And Oxygen Nipple ) 1.004 Tracheal Mask 1.005 Pericardiocentesis Catheter ( Single Lumen Cvp Catheter ) 1.006 Temporary Cardiac Pacing Leads ( Transvenous Vvi Pacing; Compatible With Biotronic Pacemakers Available At The User Department ) 1.007 Ventilator Circuit-Single Patient Use, Disposable With Water Traps Double Limb Circuit 1.008 Pacing Catheter - 7F 1.009 Legionella Urinary ( Antigen Card ) 1.010 Streptococcal Urinary ( Antigen Card ) 1.011 Urine For Glucose Protein Testing 1.012 Arterial Cannulae 20G With Flow Switch; Length Less Than 5 Cm 1.013 Auto-Venting 1Ml Arterial Blood Sampling Syringes With Dry Sprayed Balanced Heparin Formulations ( Lithium Heparin ) With 22-25G Needle With Needle Stopper, Preferably With Needle Safety Sheath And Filter Cap 1.014 Emergency Percutaneous Cricothyrotomy Set With Seldinger Technique 1.015 Endotracheal Tube Cuff Pressure Monitor 1.016 Gum Elastic Bougie ( To Aid Difficult Intubation ) : Reusable; 15 F Sizes Of At Least 70 Cm Length 1.017 Stillet With Pvc Insulation, Malleable With Metal Core And Soft Retracted Metal Tip - Adult 1.018 Peripherally Inserted Cvp Catheter With Stillette - 70 Cms, 16G Catheter ( With 14 G Introducer Cannula ) & 18G Catheter ( With 16 G Introducer Cannula ) 1.019 Double Lumen Dialysis Curved Extension Catheter Kit With Following Parameters ( 1 ) Two Lumens Of Double-D Design ( 2 ) Laser Cut Side Slots To Avoid Positional Occlusion ( 3 ) Clear. Silicon Extensions ( 4 ) Size 11.5 Fr X 13.5 Cm ( 5 ) 2 Dilators In A Pack 1.020 Cvp Cable Compatible With Carescape Monitor B450 1.021 Nibp Cable And Cuff Compatible With Carescape Monitor B450- Adult Size 1.022 Nibp Cable And Cuff Compatible With Carescape Monitor B450- Large Adult Size 1.023 Nibp Cable And Cuff Compatible With Carescape Monitor B450-Small Adult Size 1.024 Saturation Probe And Cable Compatible With Carescape Monitor B450 1.025 Solution For Hemofiltration And Hemodialysis For Intravenous And / Or Continuous Hemodialysis, Potassium Free 5000Ml / Bag 1.026 Adult Diaper , Latex Free, Hydrophilic Non-Woven- 50”-70” 1.027 Adult Underpads 1.028 Ventilator Circuits - Double Limb With Trap Macquet 1.029 Oxygen Mask Without Nebulizer 1.030 Oxygen Mask With Tubing 1.031 T- Piece Connector ( With Corrugated Side Tube And Oxygen Nipple 1.032 Ecg Clip Clamp ( Set Of 4 ) 1.033 Stillet With Pvc Insulation, Malleable With Metal Core And Soft Retracted Metal Tip - Adult 1.034 Glucose Test Strips For Blood Compatible Glucometer Should Be Supplied Free Of Cost To All Wards, Labs And Services Where It Is Required. Free Repair / Replacement Shoud Be Provided During The Period Of Use. 1.035 Resuable Nibp Cuff Suit With Wipro Ge Monitor 1.036 Spo2 Cable -Adult To Fit With Wipro Ge Ss Monitor 1.037 Neubauer Counting Chamber 1.038 O-Toluidine Powder 1.039 Ammonium Sulphate 1.040 Flash Glucose Monitoring System Specifications: It Should Have Reader And Sensor For Real Time Monitoring Of Blood Glucose. Accuracy Blood Glucose Estimation Should Be Within 20Mg / Dl. Reader Should Have Built In Port To Use Glucometer Strips And Have A Memory Of At Least 90 Days. Glucometer Strips Should Be Supplied Free Of Cost . Mean Service Life Should Be Atleast 3 Years. 1.041 Pereutaneous Dilatational Trracheostomy Sets Ciaglia Blue Rhino; With Loading Dilator Fr 24, 26, 28 & 21, 24, 27 Virus Filter For Ventilator Breathing System Specifications: 1 ) Filters Should Have Validated To Remove Ms2 Which Is Equivalent To Sars-Cov-2, Hepatitis C Virus, Hiv2, Mycobacterium Tuberculosis, Staphylococcus Aureus, And Influenza A Virus. 2 ) Filters Should Have Airborne Bacterial And Viral Removal Efficiency Of At Least 99.999% . 3 ) Filter Should Have No / Little Change In Airflow Resistance Over Time Even Under Wet Conditions. 4 ) Continuous Usage Hours For Single Patients Should Not Be Less Than 48Hours. 5 ) Filters Should Have A Dgci / Bis / European Ce / Us-Fda. Digital Hand Dynamometer: To Measure Isometric Hand Grip Stength Of Adults. Tials In Both Hands Auto Calculates Average, Stamdard Deviatgion And Co-Efficient Of Variation. Capacity : 90 Kg ( 200 Ib ) Display: Lcd Phonocardiograph Activity Of The Heart And Lungs- Cardiac Sound , Murmurs Amd Respiratory Sounds Contact Type Mir Sensor Matched Tosensor With Gain Adjustable Upto 5000 Frequency Response : 10 ?Hz To 2Khz ( +1Db ) Filter : Mass Weber Type With Cut Offs At 1 Khz With Slopes Of 20 Db , 30Db, 40Db 60 Db Octave. Adjustable By 5-Way Rotary Switch Out Put Level: Audio Visual Indication With Light Flashes And Beeps Power Requirement : 220 Or 110 Volts / 50 Cycle Or External 12 Volts D.C Power Consumption : Less Than 2 Watts
BOQ
| Name of Work: Rate Contract for supply of consumables and non-consumables for the Department of Medicine JIPMER, Puducherry – 605 006 | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Consumbale Items | |||
| 2 | 1.001 | Sterile suction catheter with mucus extractor/trap | i1 | 4400 | pieces |
| 3 | 1.002 | Catheter mount for ventilator | i2 | 6600 | pieces |
| 4 | 1.003 | T-piece connector (with corrugated side tube and oxygen nipple) | i3 | 550 | pieces |
| 5 | 1.004 | Tracheal Mask | i4 | 110 | pieces |
| 6 | 1.005 | Pericardiocentesis catheter (Single Lumen CVP catheter) | i5 | 55 | pieces |
| 7 | 1.006 | Temporary cardiac pacing leads (transvenous VVI pacing; compatible with biotronic pacemakers available at the user department) | i6 | 11 | pieces |
| 8 | 1.007 | Ventilator Circuit-single patient use, disposable with water traps double limb circuit | i7 | 110 | pieces |
| 9 | 1.008 | Pacing Catheter - 7F | i8 | 66 | pieces |
| 10 | 1.009 | Legionella Urinary (Antigen Card) | i9 | 1100 | per card |
| 11 | 1.01 | Streptococcal Urinary (Antigen Card) | i10 | 1100 | per card |
| 12 | 1.011 | Urine for glucose protein testing | i11 | 11000 | per card |
| 13 | 1.012 | Arterial cannulae 20G with flow switch; Length less than 5 cm | i12 | 55 | pieces |
| 14 | 1.013 | Auto-venting 1ml arterial blood sampling syringes with dry sprayed balanced heparin formulations (lithium heparin) with 22-25G needle with needle stopper, preferably with needle safety sheath and filter cap | i13 | 1100 | pieces |
| 15 | 1.014 | Emergency percutaneous cricothyrotomy set with seldinger technique | i14 | 5 | pieces |
| 16 | 1.015 | Endotracheal tube cuff pressure monitor | i15 | 2 | pieces |
| 17 | 1.016 | Gum elastic bougie (to aid difficult\nintubation): Reusable; 15 F sizes of at least\n70 cm length | i16 | 44 | pieces |
| 18 | 1.017 | Stillet with PVC insulation, malleable with\nmetal core and soft retracted metal tip -\nAdult | i17 | 10 | pieces |
| 19 | 1.018 | Peripherally inserted CVP catheter with stillette - 70 cms, 16G catheter (with 14 G introducer cannula) & 18G catheter (with 16 G introducer cannula) | i18 | 5 | pieces |
| 20 | 1.019 | \"Double Lumen Dialysis Curved extension catheter Kit with following parameters (1)Two lumens of Double-D design (2) Laser Cut Side slots to avoid positional occlusion (3)Clear. Silicon Extensions(4) Size 11.5 Fr x 13.5 cm (5) 2 dilators in a pack | i19 | 500 | pieces |
| 21 | 1.02 | CVP cable compatible with CARESCAPE MONITOR B450 | i20 | 10 | pieces |
| 22 | 1.021 | NIBP cable and cuff compatible with CARESCAPE MONITOR B450- adult size | i21 | 10 | pieces |
| 23 | 1.022 | NIBP cable and cuff compatible with CARESCAPE MONITOR B450- large adult size | i22 | 3 | pieces |
| 24 | 1.023 | NIBP cable and cuff compatible with CARESCAPE MONITOR B450-small adult size | i23 | 2 | pieces |
| 25 | 1.024 | Saturation probe and cable compatible with CARESCAPE MONITOR B450 | i24 | 10 | pieces |
| 26 | 1.025 | Solution for hemofiltration and hemodialysis for intravenous and/or continuous hemodialysis, potassium free 5000ml/bag | i25 | 1500 | pieces |
| 27 | 1.026 | Adult diaper ,latex free, hydrophilic non-woven- 50”-70” | i26 | 20000 | pieces |
| 28 | 1.027 | Adult underpads | i27 | 20000 | pieces |
| 29 | 1.028 | Ventilator Circuits - double limb with trap Macquet | i28 | 2500 | pieces |
| 30 | 1.029 | Oxygen mask without Nebulizer | i29 | 3000 | pieces |
| 31 | 1.03 | Oxygen mask with tubing | i30 | 1500 | pieces |
| 32 | 1.031 | T- Piece connector (with corrugated side tube and oxygen nipple | i31 | 500 | pieces |
| 33 | 1.032 | ECG Clip clamp (Set of 4) | i32 | 10 | pieces |
| 34 | 1.033 | Stillet with PVC insulation, malleable with\nmetal core and soft retracted metal tip - Adult | i33 | 40 | pieces |
| 35 | 1.034 | Glucose test strips for blood compatible glucometer should be supplied free of cost to all wards, labs and services where it is required. Free repair/ replacement shoud be provided during the period of use. | i34 | 66000 | per strip |
| 36 | 1.035 | Resuable NIBP cuff suit with Wipro GE monitor | i35 | 40 | pieces |
| 37 | 1.036 | SPO2 cable -Adult to fit with wipro GE SS Monitor | i36 | 30 | pieces |
| 38 | 1.037 | Neubauer counting chamber | i37 | 20 | pieces |
| 39 | 1.038 | O-Toluidine Powder | i38 | 500 | grams |
| 40 | 1.039 | Ammonium Sulphate | i39 | 1000 | grams |
| 41 | 1.04 | Flash Glucose Monitoring system Specifications: It should have reader and sensor for real time monitoring of blood glucose. Accuracy blood glucose estimation should be within 20mg/dl. Reader should have built in port to use glucometer strips and have a memory of at least 90 days. Glucometer strips should be supplied free of cost . Mean service life should be atleast 3 years. | i40 | 50 | Nos |
| 42 | 1.041 | Pereutaneous dilatational trracheostomy sets Ciaglia Blue Rhino; with loading dilator Fr 24, 26,28 & 21,24,27 | i41 | 50 | Pieces |
| 43 | 1.042 | Virus Filter for Ventilator Breathing System \nSpecifications: \n1) Filters should have Validated to remove MS2 which is equivalent to SARS-CoV-2, Hepatitis C virus, HIV2, Mycobacterium tuberculosis, Staphylococcus aureus, and Influenza A virus. \n2) Filters should have airborne bacterial and viral removal efficiency of at least 99.999% . \n3) Filter should have No/little change in airflow resistance over time even under wet conditions. 4) Continuous Usage Hours for Single Patients should not be less than 48Hours. \n5) Filters should have a DGCI/BIS/European CE / US-FDA. | i42 | 2640 | Pieces |
| 44 | 1.043 | \nDigital Hand Dynamometer:\nTo measure isometric hand grip stength of adults.\nTials in both hands\nAuto calculates average, stamdard deviatgion and co-efficient of variation.\nCapacity : 90 kg (200 ib)\nDisplay: LCD\n | i43 | 1 | unit |
| 45 | 1.044 | Phonocardiograph\nActivity of the Heart and lungs- cardiac sound ,murmurs amd respiratory sounds\nContact type MIR Sensor\nMatched tosensor with gain adjustable upto 5000\nFrequency response : 10 ?Hz to 2KHz(+1db)\nFilter : Mass weber type with cut offs at 1 khZ with slopes of 20 db , 30db,40db 60 db octave. Adjustable by 5-way rotary switch\nOut put level: Audio visual indication with light flashes and beeps\nPower requirement : 220 or 110 volts/50 cycle or external 12 volts D.C\nPower consumption : less than 2 watts\n | i44 | 1 | unit |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender