Repairing Of 8 Mtr Mini Mast Lights At Thannimoodu , Kochupalli , Nellimoodu And Repairing And Relocation Of 12 Mtr High Mast Light At Kamukinkode In Athiyannur Grama Panchayat Repairing Of 8 Mtr Mini Mast Lights At Thannimoodu , Kochupalli , Nellimoo
Tender Overview
Project Description
Repairing Of 8 Mtr Mini Mast Lights At Thannimoodu , Kochupalli , Nellimoodu And Repairing And Relocation Of 12 Mtr High Mast Light At Kamukinkode In Athiyannur Grama Panchayat Repairing Of 8 Mtr Mini Mast Lights At Thannimoodu , Kochupalli , Nellimoodu And Repairing And Relocation Of 12Mtr High Mast Light At Kamukinkode In Athiyannur Grama Panchayat
BOQ
| Name of Work:Repairing of 8 Mtr Mini Mast Lights at Thannimoodu, Kochupalli, Nellimoodu and Repairing and Relocation of 12 Mtr High Mast Light at Kamukinkode in Athiyannur Grama Panchayat | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Repairing of 8Mtr Mini Mast Lights at Thannimoodu, Kochupalli and Nellimoodu in Athiyannur Grama Pachayat | BI01010001010000000000000515BI0100001113 | ||
| 2 | 1.01 | Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | BI01010001010000000000000515BI0100001114 | 54 | mtr |
| 3 | 1.02 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001115 | 3 | nos |
| 4 | 1.03 | Digital timer | BI01010001010000000000000515BI0100001116 | 3 | nos |
| 5 | 1.04 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | BI01010001010000000000000515BI0100001117 | 3 | nos |
| 6 | 1.05 | 32A 2-way neutral links mounted\non DMC/SMC base | BI01010001010000000000000515BI0100001118 | 3 | nos |
| 7 | 1.06 | Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | BI01010001010000000000000515BI0100001119 | 18 | nos |
| 8 | 2 | Repair and Relocation of 12 Mtr High Mast Light at Kamukinkode in Athiyannur Grama Pachayat | BI01010001010000000000000515BI0100001120 | ||
| 9 | 2.01 | Labour charges for dismantling of High Mast Pole from existing foundation and fixing on new foundation including Crane charges | BI01010001010000000000000515BI0100001121 | 1 | nos |
| 10 | 2.02 | Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | BI01010001010000000000000515BI0100001122 | 18 | mtr |
| 11 | 2.03 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. | BI01010001010000000000000515BI0100001123 | 2 | nos |
| 12 | 2.04 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001124 | 1 | nos |
| 13 | 2.05 | Digital timer | BI01010001010000000000000515BI0100001125 | 1 | nos |
| 14 | 2.06 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | BI01010001010000000000000515BI0100001126 | 1 | nos |
| 15 | 2.07 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole | BI01010001010000000000000515BI0100001127 | 1 | nos |
| 16 | 2.08 | Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | BI01010001010000000000000515BI0100001128 | 6 | nos |
| 17 | 2.09 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.\n3 core 10 sq mm | BI01010001010000000000000515BI0100001129 | 50 | mtr |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender