Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #28261763

Repair/Replacement Of Unsv Gi Pipe/Flange /Reducer/ Valves From Existing Pumps Incl Mise Works Taking Out 30Hp Centrifugel Pump 1 Nos Repair And Replacment Of Unsv Spare Parts With Re-Installed At Chani Morg Pump House And Phase-Ii Pump House Under

Issued by Statutory Bodies & Commissions/Committees · GE (AF) Udhampur, Jammu And Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Jun 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
GE (AF) Udhampur → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair/Replacement Of Unsv Gi Pipe/Flange /Reducer/ Valves From Existing Pumps Incl Mise Works Taking Out 30Hp Centrifugel Pump 1 Nos Repair And Replacment Of Unsv Spare Parts With Re-Installed At Chani Morg Pump House And Phase-Ii Pump House Under

BOQ

Name of Work: REPAIR / REPLACEMENT OF UNSV GI PIPE/FLANGE /REDUCER/ VALVES FROM EXISTING PUMPS INCL MISE WORKS TAKING OUT 30HP CENTRIFUGEL PUMP 1 NOS REPAIR AND REPLACMENT OF UNSV SPARE PARTS WITH RE- INSTALLED AT CHANI MORGH PUMP HOUSE AND PHASE-II PUMP HOUSE UNDER GE (AF) UDHAMPUR AT 39 WING AF STN.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11(a) Pump NO-1:-Taking out old unsv 100mm GI pipe/ Flange /Valve/ reducer from Existing 30 HP monoblock pump delivery section and Supply, fabrication of 100 mm nominal dia MS pipe ERW steel (class -C) including specials such as Flange, Tee, bends, Nipple, nuts, bolts ,washer of suitable size nominal dia 100 mm as per IS 1239, IS 3589 (I) 2004 (including welding work ) complete all as specified and as directed Engr-in-Charge. Each -01\n(b) Pump NO-2:-Taking out old unsv 100mm GI pipe/ Flange /Valve/ reducer from Existing 30 HP monoblock pump delivery section and Supply, fabrication of 100 mm nominal dia MS pipe ERW steel (class -C) including specials such as Flange, Tee, bends, Nipple, nuts, bolts ,washer of suitable size nominal dia 100 mm as per IS 1239, IS 3589 (I) 2004 (including welding work ) complete all as specified and as directed Engr-in-Charge. Each -01\n(c) Pump NO-3:-Supply, fabrication of 100 mm nominal dia MS pipe ERW steel (class -C) including specials such as Flange, Tee, bends, Nipple, nuts, bolts ,washer of suitable size nominal dia 100 mm as per IS 1239, IS 3589 (I) 2004 (including welding work ) complete all as specified and as directed Engr-in-Charge. Each -01\n(d) 40HP Mono block Pump /Loading from store / un loading/ lifting/ shifting from vehicle and erection of 40HP Monoblock pump set carefully and complete all as specified and as directed Engr-in-Charge (inclu PCC / plastering / work complete). Each -01\n(e) Pump NO-1:-Supply and fabrication of 50 x 100 mm reducer of suitable size for existing level with hevy duty Flange welding both end etc complete all as specified and directed Engr-in-Charge. Each -01\n(f) Pump NO-2:-Supply and fabrication of 80 x 100 mm reducer of suitable size for existing level with hevy duty Flange welding both end etc complete all as specified and directed Engr-in-Charge. Each -01\n(g) Pump NO-3:-Supply and fabrication of 80 x 100 mm reducer of suitable size for existing level with hevy duty Flange welding both end etc complete all as specified and directed Engr-in-Charge Each -011Job
22(h) Supply and fixing of 100 mm nominal dia MS pipe ERW steel (class -C) including specials such as Flange, Tee, bends, Nipple, nuts, bolts ,washer of suitable size nominal dia 100 mm as per IS 1239, IS 3589 (I) 2004 (including welding work ) complete all as specified and as directed Engr-in-Charge. RM-15\n(j) Taking out old unsv 100mm Sluice valve and S&F 100mm bore Cast iron flanged sluice valve PN 1.6 with stainless steel spindle and CI wheel head with flanged ends, including necessary jointing material such as rubber gasket, bolts, nut & washer of suitable size and welding including testing etc complete all as specified and directed. Each-06\n(k) MS Flange 50 mm heavy duty with rubber washer 5mm including nut and bolt. Each-02\n(l) MS Flange 80 mm heavy duty with rubber washer 5mm including nut and bolt. Each-02\n(m) MS Flange 100 mm heavy duty with rubber washer 5mm including nut and bolt. Each-04\n(n) Supply and laying GI water tubing 80 mm bore , medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) complete all as specified and directed by Engr-in-Charge. RM-03\n(o) M&L for PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) in foundation. CuM- 0.864\n(p) M&L for construction of brick works of required size and shape, with sub class ‘B’ bricks, in cement mortar 1:4 for supporting of pipe line, complete all as specified and directed. CuM- 5.184\n(q) M&L for 10 mm thick cement plaster, in CM 1:4 on fair faces of brick work or concrete surfaces and finished even and fair, complete all as specified and directed. Sq Meter - 14.4
33(r) Channi Morgh pump house:- Electric line disconnected, removing from existing pipe line and Taking out carefully Centrifugel pump 30 HP , after Repairing Same re fitting incl replacement of suitable rubber waser 5 mm & new nut, bolt, washer & testing complete all as specified and directed Engr-in-Charge. (Note: - Any repair required for pumping set, will be measured and paid separately under respective items. T&P required for repairs , lowering or taking up of pumping set will be the responsibility of the contractor incl tranfort from pump house to workshop & back and rates quoted are deemed to be included in unit rate quoted). Each-01\n(s) Dismantling centrifugel pump motor of capacity 30 HP and rewinding the motor with super enameled copper conductor of standard size including varnish, insulation paper and soldering of connection etc. Assembly of motor with pump set with necessary studs, bolts, washers etc complete with all connection all as specified and directed. Each-01\n(t) Pump shaft. Each-01\n(u) Bearing Each-01
44(v) Upper camp Fountain : Electric line disconnected, removing from existing pipe line From fountain and Taking out carefully open well pump heavy duty 5 HP , after Repairing Same re-fitting incl replacement of suitable rubber waser 5 mm & new nut, bolt, washer & testing complete all as specified and directed Engr-in-Charge. (Note: - Any repair required for pumping set, will be measured and paid separately under respective items. T&P required for repairs , lowering or taking up of pumping set will be the responsibility of the contractor incl transfort from pump house to workshop & back and rates quoted are deemed to be included in unit rate quoted). Each-01\n(w) dismantling open well pump hevay duty motor of capacity 5 HP and rewinding the motor with super enameled copper conductor of standard size including varnish, insulation paper and soldering of connection etc. Assembly of motor with pump set with necessary studs, bolts, washers etc complete with all connection all as specified and directed. Each-01\n(x) Cleaning / removing rested /junk/mud/ dust & lath working complete for impeller ,vane and pump casing complete. Each-01\n(y) Removing unsv armature from motor and refitting same new one. Each-01\n(z) Removed existing all damaged bearing and replacement of all bearing. Set-01\n(aa) Replacement of unserviceable dual stator 5 HP 3 phase ,415-440 volt, 50Hrz complete set. Each-01
55(ab) Dismantling carefully of existing fountain water line circle pipe with Nozzle , pipe line cleaning , blocked nozzle clean blocking, and carried out the following works, incl refitting, testing complete ( Incl replacement of socket, union, reducer with welding work complete). Job-01\n(ac) Replacement of damaged unsv pipe 50 mm dia with bending / welding / inseting with 15 mm pipe with threading suitable for 15mm nozzel has been fitting and complete the existing same model all as directed. Job-01\n(ad) Replacement of unserviceable gate valve brass 50mm-01 No. Each -01\n(ae) Replacement of unserviceable nozzle existing same size 15 mm Brass with socket complete. Each-22\n(af) Replacement of unserviceable center fountain 25 mm size internal thread Brass. Each -01
66(ag) Replacement of unsv fountain Light 15 watts LED with clamp. Each -08\n(ah) Replacement of unsv fountain Light 50 watts LED Float light with clamp. Each -02\n(aj) Replacement of unsv Center fountain Light 30 watts LED light with clamp. Each -01\n\n\n

AI Tender Summary

OUR REF NO 28261763
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 28-06-2021
Authority
Authority Name Military Engineer Services
Work Description Repair/Replacement Of Unsv Gi Pipe/Flange /Reducer/ Valves From Existing Pumps Incl Mise Works Taking Out 30Hp Centrifugel Pump 1 Nos Repair And Replacment Of Unsv Spare Parts With Re-Installed At Chani Morg Pump House And Phase-Ii Pump House Under
Basic Detail
Tender No 3008/Q/21-22/02/E3
Bidding Type Tender
Location
City GE (AF) Udhampur
State Jammu And Kashmir
Key Dates
Publish Date 21 Jun 2021
Submission Date 28 Jun 2021
Open Date 30 Jun 2021
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
Tendernotice_1.pdf
TandC.pdf
A52B24C7-DC95-4E1E-BB78-EB21885BB5E9.html
BOQ_505288.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 21, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 28, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 30, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

TandC.pdf

html

A52B24C7-DC95-4E1E-BB78-EB21885BB5E9.html

xls

BOQ_505288.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders