| 1 | 1 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)\n4 way (4 + 12), Double door\nMake: Legrand/Hager/Schnieder | item1 | 1 | Each |
|---|
| 2 | 1.1 | Supplying and fixing following rating, four pole, 415 V, MCB in\nthe existing MCB DB complete with connections, testing and\ncommissioning etc. as required.\n63 Amp 4pole 25KA C curve MCB, Make: Legrand/Hager/Schnieder | item2 | 1 | Nos |
|---|
| 3 | 1.2 | Supplying and fixing 10A and 16 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. \n SP MCB, “C” curve, 10 kA breaking capacity.\nMake: Legrand/Hager/Schnieder | item3 | 3 | Nos |
|---|
| 4 | 1.3 | Supplying and fixing 32 A rating, 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. \n TP MCB, “C” curve, 10 kA breaking capacity.\nMake: Legrand/Hager/Schnieder | item4 | 5 | Nos |
|---|
| 5 | 2 | Supplying and fixing 4pole double door TPN sheet steel enclosure on surface/ recess along with 32A 240 V \"C\" curve 4P MCB complete with connections, testing and commissioning etc. as required. \nMake: Legrand/Hager/Schnieder | item5 | 5 | Each |
|---|
| 6 | 3 | Supplying and fixing of 6 Module Modular PVC Surface Box with base and face plate/cover plate with 2 nos. of 6/16A socket outlet with 2 nos. of Modular switch including installation, fixing of switch and socket and connection.) in the surface.\n2 socket and 2nos. Of Switch each \nMake: Legrand (Mylinc/Myrius) | item6 | 16 | Each |
|---|
| 7 | 4 | Wiring for circuit/ submain wiring alongwith earth wire with the\nfollowing sizes of FRLS PVC insulated copper conductor, single\ncore cable in surface/ recessed medium class PVC conduit as\nrequired.\n4 X 16 sq. mm + 2 X 6 sq. mm earth wire\nMake: Polycab/Universal/RR/Havells | item7 | 10 | Metre |
|---|
| 8 | 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.\n4 X 4 sq. mm + 2 X 4 sq. mm earth wire \nMake: Polycab/Universal/Finolex/RR | item8 | 140 | Mtr |
|---|
| 9 | 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.\nFRLS multi core Cable: 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire \nMake: Polycab/Universal/Finolex/RR | item9 | 200 | Mtr |
|---|