Sales : +91-777 804 8217
| Name of Work:Raze and Rebuild of Bhagwati Filling Station under Kolkata DO of West Bengal State Office | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Qty | Units | |
| 1 | 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 | ITEM CODE 1 | ||
| 2 | 2 | i) All kinds of Soil | ITEM CODE 2 | 250 | M3 |
| 3 | 3 | Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil | ITEM CODE 3 | 45 | M3 |
| 4 | 4 | Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil | ITEM CODE 4 | ||
| 5 | 5 | i) Pipes,cables etc. not exceeding 80mm dia | ITEM CODE 5 | 50 | M |
| 6 | 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m | ITEM CODE 6 | 245 | M3 |
| 7 | 7 | Supply & filling of local earth (including royalty) by mechanical transport also including ramming & watering of the earth in layers not exceeding 20cm in depth in plot, trenches, plinth, sides of foundations etc. complete | ITEM CODE 7 | 15 | M3 |
| 8 | 8 | Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. | ITEM CODE 8 | ||
| 9 | 9 | i) Local Fine Sand within grading zone IV | ITEM CODE 9 | 120 | M3 |
| 10 | 10 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: | ITEM CODE 10 | ||
| 11 | 11 | iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) | ITEM CODE 11 | 4 | M3 |
| 12 | 12 | v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) | ITEM CODE 12 | 100 | M3 |
| 13 | 13 | viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm) | ITEM CODE 13 | 2 | M3 |
| 14 | 14 | Centering and shuttering including strutting, propping etc. and removal of form work for: | ITEM CODE 14 | ||
| 15 | 15 | i) Foundations,footings,bases of column | ITEM CODE 15 | 95 | M2 |
| 16 | 16 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil | ITEM CODE 16 | 20 | M2 |
| 17 | 17 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level | ITEM CODE 17 | ||
| 18 | 18 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm | ITEM CODE 18 | 50 | M3 |
| 19 | 19 | Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : | ITEM CODE 19 | ||
| 20 | 20 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm | ITEM CODE 20 | 40 | M3 |
| 21 | 21 | Providing and laying RCC work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). | ITEM CODE 21 | 2 | M3 |
| 22 | 22 | Centering and shuttering including strutting, propping etc. and removal of form for : | ITEM CODE 22 | ||
| 23 | 23 | i) Foundations,footings,bases of columns, etc. for mass concrete | ITEM CODE 23 | 120 | M2 |
| 24 | 24 | iii) Suspended floors,roofs,landings,balconies, access platform and Shelves (Cast in situ) | ITEM CODE 24 | 300 | M2 |
| 25 | 25 | iv) Lintels, beams plinth beams,girders bressumers and cantilevers | ITEM CODE 25 | 80 | M2 |
| 26 | 26 | v) Columns, Pillars, Piers, Abutments, Posts and Struts. | ITEM CODE 26 | 150 | M2 |
| 27 | 27 | vii) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards | ITEM CODE 27 | 40 | M2 |
| 28 | 28 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels | ITEM CODE 28 | ||
| 29 | 29 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 | ITEM CODE 29 | 11000 | KG |
| 30 | 30 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth | ITEM CODE 30 | ||
| 31 | 31 | ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH | ITEM CODE 31 | 65 | M3 |
| 32 | 32 | iv) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand) in superstructure in all shapes & sizes in superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL | ITEM CODE 32 | 20 | M3 |
| 33 | 33 | viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH | ITEM CODE 33 | 15 | M2 |
| 34 | 34 | Brick on edge flooring with bricks of Class designation 7.5 on a bed of 12mm cement mortar including filing the joints with same mortar with common burnt clay non modular bricks | ITEM CODE 34 | ||
| 35 | 35 | ii) cement mortar 1:6 (1 cement : 6 fine sand) | ITEM CODE 35 | 75 | M2 |
| 36 | 36 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. | ITEM CODE 36 | ||
| 37 | 37 | i) Raj Nagar Plain white marble or Udaipur green marble or Zebra black marble or Cuddapa stone having Area of slab upto 0.50 sqm | ITEM CODE 37 | 20 | M2 |
| 38 | 38 | Extra for providing edge moulding to 18mm Granite/ marble stone counters,Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge. | ITEM CODE 38 | ||
| 39 | 39 | ii) Granite work | ITEM CODE 39 | 20 | M |
| 40 | 40 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters & similar location in marble/Granite/stone work including necessary holes for pillar taps etc.including rubbing and polishing of cut edges etc.complete | ITEM CODE 40 | 5 | EA |
| 41 | 41 | Providing & fixing MS grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc.including priming coat with approved steel primer (fixed to steel windows by welding) all complete. | ITEM CODE 41 | 130 | KG |
| 42 | 42 | Providing and fixing 150 mm bright finished chrome plated brass hanging type floor door stopper with rubber cushion necessary brass screws, etc. complete. to suit shutter thickness complete | ITEM CODE 42 | 10 | EA |
| 43 | 43 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. | ITEM CODE 43 | 1 | EA |
| 44 | 44 | Providing & fixing chromium plated brass 100mm mortice latch & lock with 6 levers & a pair of lever handles with necessary screws etc complete (best make of approved quality). | ITEM CODE 44 | 10 | EA |
| 45 | 45 | Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogeneous fine cellular structure having smooth outer integral skin having 62mm width and 32mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38mm x 4mm & PVC solvent cement, including fixing the frame to wall with suitable dia and length anchor fastener as per manufacturer's specification and direction of Engineer-in-charge. | ITEM CODE 45 | 6 | M |
| 46 | 46 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) | ITEM CODE 46 | ||
| 47 | 47 | i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections | ITEM CODE 47 | 175 | KG |
| 48 | 48 | iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) | ITEM CODE 48 | 40 | KG |
| 49 | 49 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): | ITEM CODE 49 | ||
| 50 | 50 | ii) With float glass panes of 5.0 mm thickness (weight not less than 12.5kg/sqm) | ITEM CODE 50 | 20 | M2 |
| 51 | 51 | iii) With float glass panes of 8.0 mm thickness (weight not less than 20kg/sqm) | ITEM CODE 51 | 10 | M2 |
| 52 | 52 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. | ITEM CODE 52 | ||
| 53 | 53 | ii) With brass cover plate | ITEM CODE 53 | 4 | EA |
| 54 | 54 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. | ITEM CODE 54 | 8 | EA |
| 55 | 55 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). | ITEM CODE 55 | 15 | M2 |
| 56 | 56 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: | ITEM CODE 56 | 20000 | KG |
| 57 | 57 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover | ITEM CODE 57 | 30 | M2 |
| 58 | 58 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in- charge.(area of grill to be measured). | ITEM CODE 58 | 7 | M2 |
| 59 | 59 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete. | ITEM CODE 59 | 5 | EA |
| 60 | 60 | Providing & fixing hand rail of approved size, welding etc. to steel ladder railing,balcony railing & staircase railing and similar works including applying priming coat of approved steel primer. | ITEM CODE 60 | ||
| 61 | 61 | i) M.S. tube | ITEM CODE 61 | 20 | KG |
| 62 | 62 | 40mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete. | ITEM CODE 62 | 10 | M2 |
| 63 | 63 | 18mm thick Cement plaster skirting with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement. | ITEM CODE 63 | 10 | M2 |
| 64 | 64 | Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement | ITEM CODE 64 | 30 | M2 |
| 65 | 65 | Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade. | ITEM CODE 65 | 25 | M2 |
| 66 | 66 | Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete. | ITEM CODE 66 | 10 | M2 |
| 67 | 67 | Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified | ITEM CODE 67 | ||
| 68 | 68 | i) Flooring with size of Tiles 60x60Cm in cement mortar 1:4 | ITEM CODE 68 | 85 | M2 |
| 69 | 69 | iv) Skirting with size of Tiles 80x80Cm in cement mortar 1:3 | ITEM CODE 69 | 20 | M2 |
| 70 | 70 | Deduct for not using 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.30kg/sqm | ITEM CODE 70 | 75 | M2 |
| 71 | 71 | Fixing glazed/ Ceramic/Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 , using quick set tile adhesive(water based) in average 3mm thickness. | ITEM CODE 71 | 75 | M2 |
| 72 | 72 | Providing and fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge. | ITEM CODE 72 | ||
| 73 | 73 | i) Profile Sheet for roofing | ITEM CODE 73 | 300 | M2 |
| 74 | 74 | ii) Plain Sheet for Ridges (500 - 600mm). | ITEM CODE 74 | 50 | M |
| 75 | 75 | iii) Plain sheet for Flashings/ Aprons (Upto 600 mm) | ITEM CODE 75 | 45 | M |
| 76 | 76 | iv) Plain Sheet for Gutter (600 mm over all girth) | ITEM CODE 76 | 50 | M |
| 77 | 77 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. | ITEM CODE 77 | ||
| 78 | 78 | ii) 110 mm diameter | ITEM CODE 78 | 40 | M |
| 79 | 79 | iii) 160 mm diameter PVC Rain water pipe | ITEM CODE 79 | 40 | M |
| 80 | 80 | Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure. | ITEM CODE 80 | 300 | M2 |
| 81 | 81 | Providing and laying cement plaster on surfaces with fine sand including curing etc. | ITEM CODE 81 | ||
| 82 | 82 | i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) | ITEM CODE 82 | 200 | M2 |
| 83 | 83 | v) 20mm Cement plaster of mix 1:4 (1 cement: 4 fine sand) | ITEM CODE 83 | 100 | M2 |
| 84 | 84 | Providing and laying cement plaster on surfaces with Coarse sand including curing etc. | ITEM CODE 84 | ||
| 85 | 85 | i) 12mm Cement plaster of mix 1:4 (1 cement: 4 coarse sand) | ITEM CODE 85 | 100 | M2 |
| 86 | 86 | Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc. | ITEM CODE 86 | ||
| 87 | 87 | i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand) | ITEM CODE 87 | 50 | M2 |
| 88 | 88 | Providing Neat cement punning | ITEM CODE 88 | 10 | M2 |
| 89 | 89 | Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete | ITEM CODE 89 | 400 | M2 |
| 90 | 90 | Distempering with oil bound washable distemper of approved brand & manufacture to give an even shade with 2 or more coats including water thinnable priming coat with cement primer | ITEM CODE 90 | 10 | M2 |
| 91 | 91 | Distempering with 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50gm/ltr of approved manufacturer, of required shade and colour complete as per manufacturer's specification with 2 or more coats | ITEM CODE 91 | 200 | M2 |
| 92 | 92 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : | ITEM CODE 92 | 200 | M2 |
| 93 | 93 | Finishing walls with water proofing cement paint of required shade with Two or more coats applied @ 3.84 kg/10 sqm: | ITEM CODE 93 | 100 | M2 |
| 94 | 94 | Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) | ITEM CODE 94 | 100 | M2 |
| 95 | 95 | Painting on G.S. sheet with synthetic enamel paint of approved brand & manufacture of required colour to give an even shade, 2 or more coats,including a coat of approved steel primer but excluding a coat of mordant solution | ITEM CODE 95 | 100 | M2 |
| 96 | 96 | Applying a coat of mordant solution on G.S. sheet with a solution of 38 gms of copper acetate in a litre of soft water | ITEM CODE 96 | 100 | M2 |
| 97 | 97 | Demolishing cement concrete manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction of Engineer-in-charge. | ITEM CODE 97 | ||
| 98 | 98 | i) 1:3:6 or richer mix (i/c equivalent design mix) | ITEM CODE 98 | 20 | M3 |
| 99 | 99 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars & disposal of unserviceable material outside site to an unobjectionable place as/ direction of Engineer-in-charge | ITEM CODE 99 | 50 | M3 |
| 100 | 100 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. | ITEM CODE 100 | 50 | M2 |
| 101 | 101 | Demolishing brick work manually/mechanical means including stacking of serviceable material & disposal of unserviceable material outside premises at an unobjectionable place as / direction of Engg-in-charge | ITEM CODE 101 | 25 | M3 |
| 102 | 102 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within premises | ITEM CODE 102 | ||
| 103 | 103 | ii) Of area beyond 3 sq. metres | ITEM CODE 103 | 50 | EA |
| 104 | 104 | Dismantling Steel work in built up sections in angles, tees, flats channels etc. including all gusset plates, bolts nuts, cutting rivets welding etc. including dismembering and stacking within premises | ITEM CODE 104 | 12000 | KG |
| 105 | 105 | Dismantling roofing including ridges, hips valleys & gutters, False ceiling of any type and stacking the material within premises, of: | ITEM CODE 105 | ||
| 106 | 106 | ii) Asbestos Cement sheet | ITEM CODE 106 | 30 | M2 |
| 107 | 107 | Dismantling manually/by mechanical means including stacking of serviceable material & disposal of unserviceable material outside site at unobjectionable place as per direction of Engineer-in-charge : | ITEM CODE 107 | ||
| 108 | 108 | i) Water bound macadam road | ITEM CODE 108 | 30 | M2 |
| 109 | 109 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material within premises lead as directed by Engineer-in-charge. | ITEM CODE 109 | 40 | M2 |
| 110 | 110 | Providing & laying factory made reflective type Lacquered finish Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. (Payment for provision of edge restraints shall be made separately) | ITEM CODE 110 | ||
| 111 | 111 | ii) M40 grade 80 mm thick reflective type Lacquered finish | ITEM CODE 111 | 1700 | M2 |
| 112 | 112 | Providing and fixing water closet squatting pan (Indian type W.C.pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C.flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required -White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. | ITEM CODE 112 | 1 | EA |
| 113 | 113 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white PVC flushing cistern including flush pipe with manually controlled device (handle lever),conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required: | ITEM CODE 113 | ||
| 114 | 114 | i) W.C. pan with ISI marked white solid plastic seat and lid | ITEM CODE 114 | 1 | EA |
| 115 | 115 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : | ITEM CODE 115 | ||
| 116 | 116 | i) One urinal basin with 5 litre white P.V.C. automatic flushing cistern | ITEM CODE 116 | 2 | EA |
| 117 | 117 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : | ITEM CODE 117 | ||
| 118 | 118 | ii) White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap | ITEM CODE 118 | 4 | EA |
| 119 | 119 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | ITEM CODE 119 | 2 | EA |
| 120 | 120 | Providing and fixing toilet paper holder : | ITEM CODE 120 | ||
| 121 | 121 | i) C.P. brass | ITEM CODE 121 | 1 | EA |
| 122 | 122 | Providing and fixing soil, waste and vent pipes : | ITEM CODE 122 | ||
| 123 | 123 | i) 100mm dia Sand cast iron S&S pipe as per IS: 1729. | ITEM CODE 123 | 10 | M |
| 124 | 124 | Providing & fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : | ITEM CODE 124 | ||
| 125 | 125 | i) 100mm inlet & 100mm outlet SCI S&S as per IS - 3989. | ITEM CODE 125 | 2 | EA |
| 126 | 126 | ii) 100mm inlet & 75mm outlet SCI S&S as per IS - 3989. | ITEM CODE 126 | 2 | EA |
| 127 | 127 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. | ITEM CODE 127 | ||
| 128 | 128 | i) 15 mm nominal outer dia Pipes | ITEM CODE 128 | 30 | M |
| 129 | 129 | ii) 20 mm nominal outer dia Pipes | ITEM CODE 129 | 40 | M |
| 130 | 130 | Providing and fixing brass bib cock of approved quality : | ITEM CODE 130 | ||
| 131 | 131 | i) 15 mm nominal bore | ITEM CODE 131 | 4 | EA |
| 132 | 132 | Providing and fixing brass stop cock of approved quality : | ITEM CODE 132 | ||
| 133 | 133 | i) 15 mm nominal bore | ITEM CODE 133 | 4 | EA |
| 134 | 134 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : | ITEM CODE 134 | ||
| 135 | 135 | i) 25 mm nominal bore | ITEM CODE 135 | 2 | EA |
| 136 | 136 | Constructing masonry Chamber 30x30x50 cm, inside, in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with CI surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement:2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design: With common burnt clay F.P.S (non modular) bricks of class designation 7.5 | ITEM CODE 136 | 1 | EA |
| 137 | 137 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank | ITEM CODE 137 | 1000 | L |
| 138 | 138 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty | ITEM CODE 138 | ||
| 139 | 139 | iv) 300 mm dia. R.C.C. pipe | ITEM CODE 139 | 40 | M |
| 140 | 140 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: | ITEM CODE 140 | ||
| 141 | 141 | ii) Inside dimensions 500x700 mm and 45 cm deep for pipeline with one or two inlets with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | ITEM CODE 141 | 5 | EA |
| 142 | 142 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | ITEM CODE 142 | 1 | EA |
| 143 | 143 | Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : | ITEM CODE 143 | ||
| 144 | 144 | v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate | ITEM CODE 144 | 32 | EA |
| 145 | 145 | vi) 32mm dia x 1125mm long with 100 mm dia x 8 mm thick plate | ITEM CODE 145 | 6 | EA |
| 146 | 146 | Supplying & Fixing of following items for electrical safety in switch rooms/DG rooms etc | ITEM CODE 146 | ||
| 147 | 147 | i) Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 33 kV. Test certificate to be provided with supply. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. | ITEM CODE 147 | 2 | M2 |
| 148 | 148 | ii) 6 mm thick chequered plate on cable trench inside swtich room, DG room, earthing pit including cutting, painting, lifting hooks, etc | ITEM CODE 148 | 5 | M2 |
| 149 | 149 | PROVIDING INTERNAL WIRING | ITEM CODE 149 | ||
| 150 | 150 | ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. | ITEM CODE 150 | 30 | EA |
| 151 | 151 | iii) Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. with modular switch, modular plate, suitable GI box | ITEM CODE 151 | 15 | EA |
| 152 | 152 | SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. | ITEM CODE 152 | ||
| 153 | 153 | i) 1or 2 module frame | ITEM CODE 153 | 5 | EA |
| 154 | 154 | ii) 3 module frame | ITEM CODE 154 | 5 | EA |
| 155 | 155 | iii) 4 module frame | ITEM CODE 155 | 5 | EA |
| 156 | 156 | iv) 6 module frame | ITEM CODE 156 | 2 | EA |
| 157 | 157 | MCB DISTRIBUTION BOARD INCLUSIVE OF SINGLE PHASE MCB Supply & fixing of MCB Distribution Board double door type, IP-42, inclusive of MCB, Single Phase, as per approved make of following types with all accessories such as tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs, etc. (MCB - 10KA Breaking Capacity) | ITEM CODE 157 | ||
| 158 | 158 | ii) 12 way DB with 32A DP as incoming-1No.& 6to16ASP as outgoing-12No | ITEM CODE 158 | 1 | EA |
| 159 | 159 | Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping | ITEM CODE 159 | ||
| 160 | 160 | ii) S/L Welded U/G HD MS Pipes of 80mm dia with fittings,doping | ITEM CODE 160 | 24 | M |
| 161 | 161 | Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. | ITEM CODE 161 | 150 | M |
| 162 | 162 | iv) S/L Welded U/G HD MS Pipes of 40mm dia with fittings,doping | ITEM CODE 162 | 10 | M |
| 163 | 163 | INSTALLATION OF SD/HD DISPENSING PUMPS (MONO /DUAL) Installation of supplied standard duty/heavy duty dispensing pump on existing pump island as per IOCL's drawings and instructions including supplying /filling required quantity of dry sand in the pit(s) below the pump | ITEM CODE 163 | ||
| 164 | 164 | i) Installation of DU Including providing necessary anchor bolts and C.C. foundation | ITEM CODE 164 | 3 | EA |
| 165 | 165 | Removing connected dispensing pump from pedestal including disconnection of pipeline, electrical connection, removal of nuts of the foundation bolts etc. complete. | ITEM CODE 165 | 3 | EA |
| 166 | 166 | ii) Re-installing MPD / MPP on existing foundation including connecting pipelines, electrical connections, tightening nuts etc. | ITEM CODE 166 | 4 | EA |
| 167 | 167 | Disconnecting, dismantling the existing screwed pipeline both above/ underground including excavating, back-filling, restoring the surfaces into original condition, disconnecting all fittings, stacking the dismantled pipes/fittings at site as directed. | ITEM CODE 167 | ||
| 168 | 168 | vii) Dismantling and stacking 50 mm dia U/G P/L | ITEM CODE 168 | 100 | M |
| 169 | 169 | viii) Dismantling and stacking 40 mm dia U/G P/L | ITEM CODE 169 | 100 | M |
| 170 | 170 | Lowering company supplied submersible water pump in the existing bore, connection of electrical power supply cable and connection of pipe fittings etc complete. Payment for new cables, pipes and any other fittings will be paid seperately. | ITEM CODE 170 | 3 | EA |
| 171 | 171 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items | ITEM CODE 171 | ||
| 172 | 172 | ii) 2 Core x 2.5 sq. mm. (copper) | ITEM CODE 172 | 200 | M |
| 173 | 173 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS | ITEM CODE 173 | 400 | M |
| 174 | 174 | v) 4 Core x 2.5 sq. mm Copper Cable FRLS | ITEM CODE 174 | 10 | M |
| 175 | 175 | CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. | ITEM CODE 175 | ||
| 176 | 176 | vii) 3 Core x 2.5 sq. mm | ITEM CODE 176 | 10 | EA |
| 177 | 177 | CABLE BRICK DUCT Providing & constructing underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, complete with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils | ITEM CODE 177 | ||
| 178 | 178 | ii) 225 mm (16 Bricks & 0.0195 cum per Mtr) | ITEM CODE 178 | 50 | M |
| 179 | 179 | Providing and laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen | ITEM CODE 179 | 50 | M |
| 180 | 180 | Supplying and providing 100mm square hensel weather proof junction box for emblem pole/ light pole/yard light | ITEM CODE 180 | 5 | EA |
| 181 | 181 | PROVISION OF EARTHING | ITEM CODE 181 | ||
| 182 | 182 | ii) Providing earthing with 80 mm dia,3.0 M long GI (Heavy duty) perforated pipe as per IS:3043 (with latest ammendment) including providing suitable earth bus for interconnection, providing a mixture of salt & charcoal, making earth pit chamber with chequered plate cover as per standard Drwng. etc. all complete as per specif. & direction of Engineer-In-charge | ITEM CODE 182 | 2 | EA |
| 183 | 183 | Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : | ITEM CODE 183 | ||
| 184 | 184 | ii) 32 x 6 mm G.I.strip | ITEM CODE 184 | 30 | M |
| 185 | 185 | iii) 50 x 6 mm G.I. Strip | ITEM CODE 185 | 100 | M |
| 186 | 186 | iv) 25 x 6 mm GI strip | ITEM CODE 186 | 10 | M |
| 187 | 187 | v) 25 x 3 mm GI strip | ITEM CODE 187 | 100 | M |
| 188 | 188 | vii) 10 S.W.G. G.I. Wire (bare) | ITEM CODE 188 | 50 | M |
| 189 | 189 | PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. | ITEM CODE 189 | ||
| 190 | 190 | COCO, Standard drawing No. ENG/IOCL/PDIL-1. List of Componets are: (a) 1 No. MCCB (3P+N) of 160 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-150A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 160 A, Manually Operated Change over switch suitable for connection of Mains supply and 75 KVA DG Set /10 KW Solar system with required No. of MCCB (160 A, 35 KA, 3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 160A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/ Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 160/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 160 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4. (l) 12 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB 20 A, 10KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA,6 Nos DP MCB of 20A, 10 KA & 3 Nos DP MCB of 25 A, 10 KA in outgoing Feeder-3 (o) 3 Nos TP MCB of 16 A, 10 KA,3 Nos TP MCB of 20A, 10 KA & 6 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL. | ITEM CODE 190 | 1 | EA |
| 191 | 191 | PROVIDING INTERNAL WIRING | ITEM CODE 191 | ||
| 192 | 192 | ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. | ITEM CODE 192 | 30 | EA |
| 193 | 193 | iii) Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. with modular switch, modular plate, suitable GI box | ITEM CODE 193 | 10 | EA |
| 194 | 194 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make | ITEM CODE 194 | ||
| 195 | 195 | ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire | ITEM CODE 195 | 150 | M |
| 196 | 196 | iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire | ITEM CODE 196 | 100 | M |
| 197 | 197 | iv) 2 x 6 sq mm + 1 x 6 sq mm earth wire | ITEM CODE 197 | 60 | M |
| 198 | 198 | vi) 2 x 16 sq mm + 1 x 16 sq mm earth wire | ITEM CODE 198 | 30 | M |
| 199 | 199 | Supply and fixing of following Electrical fittings /fixtures | ITEM CODE 199 | ||
| 200 | 200 | v) 15Amp modular type 6 pin socket | ITEM CODE 200 | 15 | EA |
| 201 | 201 | SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. | ITEM CODE 201 | ||
| 202 | 202 | xii) Fan Regulator of stepped modular type | ITEM CODE 202 | 4 | EA |
| 203 | 203 | Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc. | ITEM CODE 203 | ||
| 204 | 204 | ii) Upto 32A DP MCB | ITEM CODE 204 | 3 | EA |
| 205 | 205 | Supply and installation of MCB distribution board having Double door complete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. without incoming isolator and MCBs | ITEM CODE 205 | ||
| 206 | 206 | ii) 2+8 way SPN | ITEM CODE 206 | 1 | EA |
| 207 | 207 | MCB DISTRIBUTION BOARD INCLUSIVE OF SINGLE PHASE MCB Supply & fixing of MCB Distribution Board double door type, IP-42, inclusive of MCB, Single Phase, as per approved make of following types with all accessories such as tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs, etc. (MCB - 10KA Breaking Capacity) | ITEM CODE 207 | ||
| 208 | 208 | i) 8way DB with 32ADP as incoming-1No.& 6 to16A SP as outgoing-8Nos | ITEM CODE 208 | 1 | EA |
| 209 | 209 | CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: | ITEM CODE 209 | ||
| 210 | 210 | iii) 1200 mm sweep | ITEM CODE 210 | 8 | EA |
| 211 | 211 | EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does not include making suitable cut out in the wall for fixing the fan). | ITEM CODE 211 | ||
| 212 | 212 | ii) 9\" dia light duty, make Khaitan or equivalent | ITEM CODE 212 | 2 | EA |
| 213 | 213 | iii) 12\" heavy duty, make GEC or equivalent | ITEM CODE 213 | 1 | EA |
| 214 | 214 | DISMANTLING Dismantling of following electrical fittings / fixtures with all leads and lifts. | ITEM CODE 214 | ||
| 215 | 215 | i) Electrical cables of all sizes from under / above ground position | ITEM CODE 215 | 300 | M |
| 216 | 216 | ii) DPS board all types with/ without stand | ITEM CODE 216 | 4 | EA |
| 217 | 217 | iii) 5 to 15A switches/MCBs/plugs | ITEM CODE 217 | 40 | EA |
| 218 | 218 | iv) 32/63/100A DP/TPN switches/ MCCBs /MCBs | ITEM CODE 218 | 10 | EA |
| 219 | 219 | v) Flourescent tube light fittings of all sizes | ITEM CODE 219 | 8 | EA |
| 220 | 220 | S/F OF UNDER CANOPY RECESS MOUNTED LINEA | ITEM CODE 220 | 28 | EA |
| 221 | 221 | S/F 18W LEDTube light | ITEM CODE 221 | 19 | EA |
| 222 | 222 | S/F 30W LED light Fixture | ITEM CODE 222 | 2 | EA |
| 223 | 223 | S/F FRP TANK M/H COVER | ITEM CODE 223 | 8 | EA |
| 224 | 224 | Installation Charges for S/F of FRP/E FR | ITEM CODE 224 | 8 | EA |
| 225 | 225 | Lifting Handle C/W | ITEM CODE 225 | 1 | EA |
| 226 | 226 | 900 mm x 900 mm Flat sealed Alumunium | ITEM CODE 226 | 8 | EA |
| 227 | 227 | FASCIA FOR AIR & WATER CANOPY | ITEM CODE 227 | 10 | M |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy