Construction Of Gynecology Modular Operation Theater Complex ( 02 Nos . ) ( Such As Pre Op And Post Op . , Sterilization Room , Doctors And Nurses Changing Room And Other Related Areas ) Inside Mch Building At Dhh Campus Keonjhar For The Year 2020, Keonjhar-Odisha

Road And Building Department-RBD has published Construction Of Gynecology Modular Operation Theater Complex ( 02 Nos . ) ( Such As Pre Op And Post Op . , Sterilization Room , Doctors And Nurses Changing Room And Other Related Areas ) Inside Mch Building At Dhh Campus Keonjhar For The Year 2020. Submission Date for this Tender is 06-07-2021. Modular Operation Theater Tenders in Keonjhar Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

28255123
Construction Of Gynecology Modular Operation Theater Complex ( 02 Nos . ) ( Such As Pre Op And Post Op . , Sterilization Room , Doctors And Nurses Changing Room And Other Related Areas ) Inside Mch Building At Dhh Campus Keonjhar For The Year 2020
Open Tender
Indian
Odisha
Keonjhar
06-07-2021

Tender Details

Construction Of Gynecology Modular Operation Theater Complex ( 02 Nos . ) ( Such As Pre Op And Post Op . , Sterilization Room , Doctors And Nurses Changing Room And Other Related Areas ) Inside Mch Building At Dhh Campus Keonjhar For The Year 2020-21

Key Value

Document Fees
INR 10000 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work:Construction of Gynecology Modular operation theater complex (02 Nos.) (such as pre OP & post OP., Sterilization room, Doctors & Nurses changing room & other related areas) inside MCH Building at DHH campus keonjhar for the year 2020-21 (under OMBADC), (Civil, Electrical & miscellaneous items).
Sl. No. Item Description Item Code / Make Quantity Units
1 1 A.CIVIL WORKS:- Providing fitting & fixing of arm strong acoustic false ceiling including with cost, conveyances, taxes of all materials and cost of all labour T&P etc complete BI01010001010000000000000515BI0100001152 1500 Sqft
2 2 WALL FOR STERILE AREA painting two coats with plastic imulsion paint over a coat of wall primer including cost of paint BI01010001010000000000000515BI0100001153 420 Sqm
3 3 Finishing wall surface with cement based wall putty including cost of putty BI01010001010000000000000515BI0100001154 420 Sqm
4 4 New brick walls: S/F of Fly ash brick masonary in cement(1:4) in 3rd floor BI01010001010000000000000515BI0100001155 80 Cum
5 5 S/F of 12mm thick cement plaster (1:4) over brick wall in 1st floor BI01010001010000000000000515BI0100001156 330 Sqm
6 6 Re Modification Of Existing Brick Wall & Anthilary Civil Work BI01010001010000000000000515BI0100001157 40 Cum
7 7 Ms Structure with fabrication With Febricated Stair Case For Dirty Corridure For 02 Nos Of Gyning OT From 1st Floor to OUT Side . BI01010001010000000000000515BI0100001158 390 Sqft
8 8 MISCELLANEOUS & ELECTRICAL WORK OPERATION THEATRE CEILING S/F of 40 MM THICK PUF PANEL FRONT PANEL PPGI 0.8 MM THICK BACK PANEL PPGI 0.8 MM THICK PUF density of 40kg/m3 With Jointless Coatings: Filling of all joints & cavities with metal epoxy filler and sanded flush to provide a seamless finish including one primer and three coats of antibacterial & antifungal paint equivalent to a minimum dry film thickness of 200 microns. BI01010001010000000000000515BI0100001159 500 Sqft
9 9 OPERATION THEATER WALL S/F of 50 MM THICK PUF PANEL FRONT PANEL PPGI 0.8 MM THICK BACK PANEL PPGI 0.8 MM THICK PUF density of 40kg/m3 With Jointless Coatings: Filling of all joints & cavities with metal epoxy filler and sanded flush to provide a seamless finish including one primer and three coats of antibacterial & antifungal paint equivalent to a minimum dry film thickness of 200 microns. BI01010001010000000000000515BI0100001160 1448 Sqft
10 10 OT FLOOR & Sterile area floor: S/F of 2mm Homogenous antibacterial vinyl with welding on the edges, Copper stripping to be done and proper earthing to be done.: H. OPERATION THEATRE FLOORING& STERILE AREA FLOORING : The vendor must ensure antistatic and antibacterial flooring with homogeneous vinyl floor covering. The material should be in sheet format so as to avoid more welding. The 2 mm homogeneous material incorporates homogenousity throughout its full thickness and should carry warranty of 5yrs after laying. The product should comply with EN 649. The product is non-reactive to residual indentation with a value = 0,02 mm (EN 433) The flooring complies with the EN 649 (34-43) offering a group P-wear rating suitable for heavy duty traffic areas and Bfl-s1 fire resistance. The product is non-emissive of volatile organic compounds with < 10 Micro Gm(TVOC after 28 Days ISO -16000-6 ). The material should be laid after doing self levelling with self levelling compound. BI01010001010000000000000515BI0100001161 2500 Sqft
11 11 S/F of Self Levelling - Floor. BI01010001010000000000000515BI0100001162 2400 Sqft
12 12 Metal Flush Door With Powder Coating - 46 mm thick door leaf, 0.8 mm thick galvanized steel Paper honeycomb in fill , Powder coated door leaf , View port - 1 hour fire rated, 6 mm thick with metal frame and ceramic tape With accessories BI01010001010000000000000515BI0100001163 25 Sqm
13 13 Manual sliding door manual sliding HPL OT door with PUF insulation , with vision window 300 x300 , liver handle ,gasket, trackers , canopy SIZE :- 1500 X 2100\n BI01010001010000000000000515BI0100001164 2 No
14 14 S/F of Shade & Covering for AHU: Fully Ceiling covered by PPGI sheet structure made of MS angle and cover with MS net BI01010001010000000000000515BI0100001165 450 Sqft
15 15 Control panel as per specification: SITC of G. OPERATION THEATRE CONTROL PANEL: The surgeon control panel should meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations. The room Surgeon’s control panel should be modifiable with changing technology & equipment in operating environments. Control Panel will be user friendly & ease of operating & maintaining purpose. The panel should be “Touch Sensitivity” type; configured to incorporate all the services that operation room staff required. The fascia should be made with superior quality UV resistance screen with sterilization feature. The Panel should contain 6 or 9 service tiles as below: 1. Time Day Clock. 2. Time Elapse Day Clock. 3. General Lighting System. 4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory. 6. Temperature & humidity indicator with controller. 7. HEPA Filter Status module. 8. Room Pressure Indicator. 9. Music control. Time day clock should be digital type & clocks having high brightness characters. Time Elapsed Day Clock should be digital type & clocks having high brightness characters. Temperature indicator should indicate the room temperature which should be connected to the local pressure switches of Air-Conditioning System. Indicators should be digital type & clocks having high brightness characters, not less than 30 mm in height. Central Lighting system should incorporate all the necessary controls of the lighting. system inside the theatre. The medical gas alarm should indicate High, Normal & Low gas Pressure for each gas service present in the operating system & should have an audible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures. A hand free set Telephone System should be incorporated in the panel with memory type card. The control panel should be designed for front- access only. All internal wires should be marked with plastic Ferrule type cable markers for ease of identification and provision of Surge Arrestor. BI01010001010000000000000515BI0100001166 1 Nos
16 16 Supply & Installation of Planair Ceiling system with unidirectional airflow. Plenum unit, Holding structure & Top plenum are made of Aluminium Sheet 1.5mm thk. with aluminum extrusion frame with hepa filter having efficiency 99.97% down to0.3 micron.. in plenum level or in AHU level (AHU Level is preferred) The laminar flow system shall have such design with Diffuser : 2 layer monofilament precision woven polyester of uniform porosity with an open area of sufficient resistance to create laminar from diffusers face and integral lighting provides an illumination level in excess of 15000 Lux in operating area and 10000 Lux other electronic without flicker.Size :- 2400 X 2400 BI01010001010000000000000515BI0100001167 2 Nos
17 17 D.Medical Equipment :- X-ray View box: X RAY VIEWING SCREENS : SITC of the system should have electrical safety codes for high & low voltage system. The theatre should be equipped with a 2 plate X-ray viewing screen. It should be designed to provide flicker free luminance for the film viewing purpose. It should be installed flushed with theatre wall for hygienic and ease of cleaning purpose .The X-Ray viewing screen should be designed for the purpose of front access. The X-Ray viewing screen should be illuminated by LED with LED Ballast Technology and the dimming is controlled by the usage of dimming ballast with the PCB that is mounted inside the box. The diffuser should be able to diffuse the light evenly and to provide enough luminance for film viewing. It should be made of high quality opaque acrylic sheet. The film should be held firmly by using spring – loaded clips for ease of mounting and demounting. The body should be built by using electrolyzed steel with powder coating. It should work on PCB button control system. BI01010001010000000000000515BI0100001168 3 Nos
18 18 Medical Gas pipe line for 02 Nos Gyning OT & 03 Labour Tables BI01010001010000000000000515BI0100001169 1 Job
19 19 SITC of Writing board. BI01010001010000000000000515BI0100001170 3 Nos
20 20 SITC of Magnehlic gauge. BI01010001010000000000000515BI0100001171 1 Nos
21 21 SITC of Pressure Relief Dampers. BI01010001010000000000000515BI0100001172 4 Nos
22 22 SITC of Single arm pendant (Type Surgeon) each will be made of aluminuium sheets box, provision for (2) oxygen, (1) compresssed air medical gas 4 BAR (1) compressor air medical gas 7 BAR (1) vacuume with twin 5/15 A electrical sockets four (8) numbers, and one I.V hooks with a load bearing capacity up to 100 kgs. 1 drawer & tryas will be 2 in quantity. The movable arm length is 1000mm and rotates at 330 degree. The console of the single arm pendant moves in330 degree movement. BI01010001010000000000000515BI0100001173 3 Set
23 23 SITC of 3-Bay Scrub Sink, with Infrared Photo sensor, Digital Timer with user defined Time interval 1,3,5 and 10 minutes, 1 no. mixture valve and 2 nos. solenoid valves along with Manual Option knee Operated mechanism/ Foot switch.Anti-splash metal body construction made of Stainless Steel Grade 304 polished finished. The Scrub Sink is provided with front access panel for ease of maintenance and repairs. BI01010001010000000000000515BI0100001174 1 Set
24 24 Hatch Box (600X600 Size) - Each hatch is equipped with two doors and the doors are electronically interlocked i.e. the hatch is designed in such a way that only one door can be opened at one time. The UV light is so installed that it is kept on while both the doors are closed. This UV light turns off automatically in case of opening of either of the doors. BI01010001010000000000000515BI0100001175 2 Set
25 25 ELECTRICAL WORKS:- Celing lights: SITC of LED peripheral light cum clean room luminarie for OT area should give a total of 1500 lux in operating area and 1000 lux in other peripheral areas with steeples, flicker less dimming control down to 5% level. There shall be two minimum independent cirucits. They should be surface mounted and recessed lights. Framed light cover should be made of highly resistant and disinfectant consistent laminated safety glass with visual systems against glare of the lamps and of the internal highly specular reflectros, cumulative reflection coated , body should consist of sheet steel with mechanical and electrical removable carrier equipment. Protection IP 65 BI01010001010000000000000515BI0100001176 24 Nos.
26 26 S/F of 2'x2' LED recessed ceiling light Make: Philips/Wipro/Havells or equivalent as per the direction of Engineer-in-charge BI01010001010000000000000515BI0100001177 35 Nos.
27 27 S/F of UV light of 36w each inside OT. BI01010001010000000000000515BI0100001178 2 Nos.
28 28 SITC of Electrical panel and low side job materials for 1 OT's and Rest Area and provision of Surge Arrestor. Electrical wiring inside OT for Wall, Pendant, OT Light, CSSD/ICU/Doctors room/ Toilets etc With 6,4,2.5,1.5 Sq.MM wire with Modular Legrand/eq. make switch socket. BI01010001010000000000000515BI0100001179 2 Job
29 29 AHU 7.5 TR/3000 CFM DX Type Double Skin AHUs(R410 Refrigerant Gas) floor mounted type to be placed at AHU Room.( Surg OT-1 & OT- 2) BI01010001010000000000000515BI0100001180 1 Each
30 30 SITC of Air Handling Unit of 11TR capacity 4400 CFM and 30 air exchanges per hour. Make Zeco/VTS/Crystal. Conforming to DTCN Technical -AHU , Air Conditioning and Complete Low Side job : as per NABH with 25% fresh air and 20 air exchanges per hour with complete ducting and insulation and as per medical standards inside OT & T-ICU and 5 Air changes in OT Corridor. BI01010001010000000000000515BI0100001181 1 Each
31 31 Wired Remote Controller BI01010001010000000000000515BI0100001182 2 Each
32 32 Connecting KIT for AHUs with ODUnits BI01010001010000000000000515BI0100001183 2 Each
33 33 SITC OF Condensate UPVC drain piping with mm nominal dia (minimum 4 mm wall thickness) with U traps having provision for periodical cleaning. 32 mm dia BI01010001010000000000000515BI0100001184 40 Rft
34 34 SITC OF canvas in mouthpiece BI01010001010000000000000515BI0100001185 2 Each
35 35 Volume control damper manual BI01010001010000000000000515BI0100001186 4 Sqm
36 36 ODU 5.5 TR Top Discharge ODU ( Conect to AHU ) BI01010001010000000000000515BI0100001187 2 Each
37 37 SITC of Out door Unit Compressor Daikin/Voltas/Hitachi/Carrier or equivalent as per the direction of Engineer-in-charge of 16 TR dual compressor in OT BI01010001010000000000000515BI0100001188 1 Each
38 38 SITC OF Refrigerant Piping with proper arrengements for ms hangers, cable trays and as required. Liquid BI01010001010000000000000515BI0100001189 100 Rft
39 39 Suction BI01010001010000000000000515BI0100001190 100 Rft
40 40 Ducting & Insulation SITC OF Hand fabricated rectangular Aluminum Ducting in accordance with the approved ducting lay out drawing, complete with all accessories , dampers, guide, vanes, support, etc. 0.64 mm Aluminum Sheet BI01010001010000000000000515BI0100001191 250 Sqm
41 41 SITC Of Acoustic insulation inside the SA Ducts with 10 mm thick F.G. & 36 G perporated aluminium. BI01010001010000000000000515BI0100001192 190 Sqm
42 42 SITC of Thermal insulation over the duct with nitrile rubber without aluminum foil fire retradant insulation of 13 mm thickness. BI01010001010000000000000515BI0100001193 250 Sqm
43 43 Supply Air Grill and Return Air Grill SITC OF Dynacraft/metal forge/carryair or equivalent make linear grills or extruded aluminium section finished with power coated or approved colour. Supply Air Grill and Return Air Grill BI01010001010000000000000515BI0100001194 21 Sqm
44 44 Instalation & Others Inter Connecting communication shielded Cable with Propper PVC Conduting. 1.5sqmmx2 core BI01010001010000000000000515BI0100001195 300 Rft
45 45 SITC OF PCC Base/MS Platform BI01010001010000000000000515BI0100001196 4 Each
46 46 Commissioning ,testing ,balancing the system & handling over the same to the owner in satisfactory working condition For AHU SYSTEM. BI01010001010000000000000515BI0100001197 20 TR
47 47 Machine lifting and shifting,Chiping,wall cutting as required BI01010001010000000000000515BI0100001198 1 Lot
48 48 SITC OF refregerent gas BI01010001010000000000000515BI0100001199 31 Kg
49 49 scraf folding and other civil work as required BI01010001010000000000000515BI0100001200 1 Lot
50 50 SITC Power Supply Pvc Insulated XLPE Armoured Copper cable require to run from HVAC Pannel to the Isolater box naer the Outdoor unit.Make:- Havells/ polycab/ Glostar/ KEI. or equivalent as per the direction of Engineer-in-charge 4 X 16sqmm BI01010001010000000000000515BI0100001201 100 Rmt
51 51 SITC Of ODU Power Distrubution board suitable to mount in the outside exposed wall BI01010001010000000000000515BI0100001202 2 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail