Road And Building Department-RBD has published Construction Of Surgical Modular Operation Theater Complex ( 02 Nos . ) ( Such As Modular Ot 02 Nos . , Pre And Post-Operative , Anesthesia Room , Sterilization Room , Doctors And Nurses Changing Room And Other Related Areas ) Inside Centenary B. Submission Date for this Tender is 06-07-2021. Modular Operation Theater Tenders in Keonjhar Odisha. Bidders can get complete Tender details and download the document.
Name of Work:Construction of Surgical Modular operation theater complex (02 Nos.) (such as modular OT 02 Nos., pre & post-operative, Anesthesia room, Sterilization room, Doctors & Nurses changing room & other related areas) inside Centenary Building at DHH campus keonjhar for the year 2020-21 (under OMBADC) (Civil, Electrical & miscellaneous items). | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | A.CIVIL WORKS:- Providing fitting & fixing of arm strong acoustic false ceiling including with cost, conveyances, taxes of all materials and cost of all labour T&P etc complete | BI01010001010000000000000515BI0100001152 | 2400 | Sqft |
2 | 2 | WALL FOR STERILE AREA painting two coats with plastic imulsion paint over a coat of wall primer including cost of paint | BI01010001010000000000000515BI0100001153 | 1000 | Sqm |
3 | 3 | Finishing wall surface with cement based wall putty including cost of putty | BI01010001010000000000000515BI0100001154 | 1200 | Sqm |
4 | 4 | New brick walls: S/F of Fly ash brick masonary in cement(1:4) in 3rd floor | BI01010001010000000000000515BI0100001155 | 90 | Cum |
5 | 5 | S/F of 12mm thick cement plaster (1:4) over brick wall in 1st floor | BI01010001010000000000000515BI0100001156 | 600 | Sqm |
6 | 6 | Re Modification Of Existing Brick Wall & Anthilary Civil Work | BI01010001010000000000000515BI0100001157 | 15 | Cum |
7 | 7 | B.MISCELLANEOUS & ELECTRICAL OPERATION THEATRE CEILING S/F of 40 MM THICK PUF PANEL FRONT PANEL PPGI 0.8 MM THICK BACK PANEL PPGI 0.8 MM THICK PUF density of 40kg/m3 With Jointless Coatings: Filling of all joints & cavities with metal epoxy filler and sanded flush to provide a seamless finish including one primer and three coats of antibacterial & antifungal paint equivalent to a minimum dry film thickness of 200 microns. | BI01010001010000000000000515BI0100001158 | 900 | Sqft |
8 | 8 | OPERATION THEATER WALL S/F of 50 MM THICK PUF PANEL FRONT PANEL PPGI 0.8 MM THICK BACK PANEL PPGI 0.8 MM THICK PUF density of 40kg/m3 With Jointless Coatings: Filling of all joints & cavities with metal epoxy filler and sanded flush to provide a seamless finish including one primer and three coats of antibacterial & antifungal paint equivalent to a minimum dry film thickness of 200 microns. | BI01010001010000000000000515BI0100001159 | 2100 | Sqft |
9 | 9 | OT FLOOR & Sterile area floor: S/F of 2mm Homogenous antibacterial vinyl with welding on the edges, Copper stripping to be done and proper earthing to be done.: H. OPERATION THEATRE FLOORING& STERILE AREA FLOORING : The vendor must ensure antistatic and antibacterial flooring with homogeneous vinyl floor covering. The material should be in sheet format so as to avoid more welding. The 2 mm homogeneous material incorporates homogenousity throughout its full thickness and should carry warranty of 5yrs after laying. The product should comply with EN 649. The product is non-reactive to residual indentation with a value = 0,02 mm (EN 433) The flooring complies with the EN 649 (34-43) offering a group P-wear rating suitable for heavy duty traffic areas and Bfl-s1 fire resistance. The product is non-emissive of volatile organic compounds with < 10 Micro Gm(TVOC after 28 Days ISO -16000-6 ). The material should be laid after doing self levelling with self levelling compound. | BI01010001010000000000000515BI0100001160 | 2500 | Sqft |
10 | 10 | S/F of Self Levelling - Floor. | BI01010001010000000000000515BI0100001161 | 2500 | Sqft |
11 | 11 | Metal Flush Door With Powder Coating - 46 mm thick door leaf, 0.8 mm thick galvanized steel Paper honeycomb in fill , Powder coated door leaf , View port - 1 hour fire rated, 6 mm thick with metal frame and ceramic tape With accessories | BI01010001010000000000000515BI0100001162 | 40 | Sqm |
12 | 12 | Manual sliding door manual sliding HPL OT door with PUF insulation , with vision window 300 x300 , liver handle ,gasket, trackers , canopy SIZE :- 1800 X 2100\n | BI01010001010000000000000515BI0100001163 | 2 | No |
13 | 13 | S/F of Shade & Covering for AHU: Fully Ceiling covered by PPGI sheet structure made of MS angle and cover with MS net | BI01010001010000000000000515BI0100001164 | 350 | Sqft |
14 | 14 | Control panel as per specification: SITC of G. OPERATION THEATRE CONTROL PANEL: The surgeon control panel should meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations. The room Surgeon’s control panel should be modifiable with changing technology & equipment in operating environments. Control Panel will be user friendly & ease of operating & maintaining purpose. The panel should be “Touch Sensitivity” type; configured to incorporate all the services that operation room staff required. The fascia should be made with superior quality UV resistance screen with sterilization feature. The Panel should contain 6 or 9 service tiles as below: 1. Time Day Clock. 2. Time Elapse Day Clock. 3. General Lighting System. 4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory. 6. Temperature & humidity indicator with controller. 7. HEPA Filter Status module. 8. Room Pressure Indicator. 9. Music control. Time day clock should be digital type & clocks having high brightness characters. Time Elapsed Day Clock should be digital type & clocks having high brightness characters. Temperature indicator should indicate the room temperature which should be connected to the local pressure switches of Air-Conditioning System. Indicators should be digital type & clocks having high brightness characters, not less than 30 mm in height. Central Lighting system should incorporate all the necessary controls of the lighting. system inside the theatre. The medical gas alarm should indicate High, Normal & Low gas Pressure for each gas service present in the operating system & should have an audible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures. A hand free set Telephone System should be incorporated in the panel with memory type card. The control panel should be designed for front- access only. All internal wires should be marked with plastic Ferrule type cable markers for ease of identification and provision of Surge Arrestor. | BI01010001010000000000000515BI0100001165 | 2 | Nos |
15 | 15 | Supply & Installation of Planair Ceiling system with unidirectional airflow. Plenum unit, Holding structure & Top plenum are made of Aluminium Sheet 1.5mm thk. with aluminum extrusion frame with hepa filter having efficiency 99.97% down to0.3 micron.. in plenum level or in AHU level (AHU Level is preferred) The laminar flow system shall have such design with Diffuser : 2 layer monofilament precision woven polyester of uniform porosity with an open area of sufficient resistance to create laminar from diffusers face and integral lighting provides an illumination level in excess of 15000 Lux in operating area and 10000 Lux other electronic without flicker.Size 1800mm x 1800mm x350mm. | BI01010001010000000000000515BI0100001166 | 2 | Nos |
16 | 16 | D.Medical Equipment :- X-ray View box: X RAY VIEWING SCREENS : SITC of the system should have electrical safety codes for high & low voltage system. The theatre should be equipped with a 2 plate X-ray viewing screen. It should be designed to provide flicker free luminance for the film viewing purpose. It should be installed flushed with theatre wall for hygienic and ease of cleaning purpose .The X-Ray viewing screen should be designed for the purpose of front access. The X-Ray viewing screen should be illuminated by LED with LED Ballast Technology and the dimming is controlled by the usage of dimming ballast with the PCB that is mounted inside the box. The diffuser should be able to diffuse the light evenly and to provide enough luminance for film viewing. It should be made of high quality opaque acrylic sheet. The film should be held firmly by using spring – loaded clips for ease of mounting and demounting. The body should be built by using electrolyzed steel with powder coating. It should work on PCB button control system. | BI01010001010000000000000515BI0100001167 | 2 | Nos |
17 | 17 | Medical Gas pipe line for 02 Nos of Surgical OT | BI01010001010000000000000515BI0100001168 | 1 | Job |
18 | 18 | SITC of Writing board. | BI01010001010000000000000515BI0100001169 | 2 | Nos |
19 | 19 | SITC of Magnehlic gauge. | BI01010001010000000000000515BI0100001170 | 2 | Nos |
20 | 20 | SITC of Pressure Relief Dampers. | BI01010001010000000000000515BI0100001171 | 2 | Nos |
21 | 21 | SITC of Single arm pendant (Type Surgeon) each will be made of aluminuium sheets box, provision for (2) oxygen, (1) compresssed air medical gas 4 BAR (1) compressed air medical gas 7 BAR (1)vacuume with twin 5/15 A electrical sockets four (8) numbers, and one I.V hooks with a load bearing capacity up to 100 kgs. 1 drawer & tryas will be 2 in quantity. The movable arm length is 1000mm and rotates at 330 degree. The console of the single arm pendant moves in330 degree movement. | BI01010001010000000000000515BI0100001172 | 4 | Set |
22 | 22 | SITC of 2-Bay Scrub Sink, with Infrared Photo sensor, Digital Timer with user defined Time interval 1,3,5 and 10 minutes, 1 no. mixture valve and 2 nos. solenoid valves along with Manual Option knee Operated mechanism/ Foot switch.Anti-splash metal body construction made of Stainless Steel Grade 304 polished finished. The Scrub Sink is provided with front access panel for ease of maintenance and repairs. | BI01010001010000000000000515BI0100001173 | 1 | Set |
23 | 23 | Hatch Box (600X600 Size) - Each hatch is equipped with two doors and the doors are electronically interlocked i.e. the hatch is designed in such a way that only one door can be opened at one time. The UV light is so installed that it is kept on while both the doors are closed. This UV light turns off automatically in case of opening of either of the doors. | BI01010001010000000000000515BI0100001174 | 1 | Set |
24 | 24 | ELECTRICAL WORKS:- Celing lights: SITC of LED peripheral light cum clean room luminarie for OT area should give a total of 1500 lux in operating area and 1000 lux in other peripheral areas with steeples, flicker less dimming control down to 5% level. There shall be two minimum independent cirucits. They should be surface mounted and recessed lights. Framed light cover should be made of highly resistant and disinfectant consistent laminated safety glass with visual systems against glare of the lamps and of the internal highly specular reflectros, cumulative reflection coated , body should consist of sheet steel with mechanical and electrical removable carrier equipment. Protection IP 65 | BI01010001010000000000000515BI0100001175 | 16 | Nos. |
25 | 25 | S/F of 2'x2' LED recessed ceiling light Make: Philips/Wipro/Havells or equivalent as per the direction of Engineer-in-charge | BI01010001010000000000000515BI0100001176 | 60 | Nos. |
26 | 26 | S/F of UV light of 36w each inside OT. | BI01010001010000000000000515BI0100001177 | 2 | Nos. |
27 | 27 | SITC of Electrical panel and low side job materials for 1 OT's and Rest Area and provision of Surge Arrestor. Electrical wiring inside OT for Wall, Pendant, OT Light, CSSD/ICU/Doctors room/ Toilets etc With 6,4,2.5,1.5 Sq.MM wire with Modular Legrand/eq. make switch socket. | BI01010001010000000000000515BI0100001178 | 2 | Job |
28 | 28 | AHU 7.5 TR/3000 CFM DX Type Double Skin AHUs(R410 Refrigerant Gas) floor mounted type to be placed at AHU Room.( Surg OT-1 & OT- 2) | BI01010001010000000000000515BI0100001179 | 2 | Each |
29 | 29 | Wired Remote Controller | BI01010001010000000000000515BI0100001180 | 2 | Each |
30 | 30 | Connecting KIT for AHUs with ODUnits | BI01010001010000000000000515BI0100001181 | 2 | Each |
31 | 31 | SITC OF Condensate UPVC drain piping with mm nominal dia (minimum 4 mm wall thickness) with U traps having provision for periodical cleaning. 32 mm dia | BI01010001010000000000000515BI0100001182 | 40 | Rft |
32 | 32 | SITC OF canvas in mouthpiece | BI01010001010000000000000515BI0100001183 | 2 | Each |
33 | 33 | Volume control damper manual | BI01010001010000000000000515BI0100001184 | 4 | Sqm |
34 | 34 | ODU 5.5 TR Top Discharge ODU ( Conect to AHU ) | BI01010001010000000000000515BI0100001185 | 4 | Each |
35 | 35 | SITC OF Refrigerant Piping with proper arrengements for ms hangers, cable trays and as required. Liquid | BI01010001010000000000000515BI0100001186 | 100 | Rft |
36 | 36 | Suction | BI01010001010000000000000515BI0100001187 | 100 | Rft |
37 | 37 | Ducting & Insulation SITC OF Hand fabricated rectangular Aluminum Ducting in accordance with the approved ducting lay out drawing, complete with all accessories , dampers, guide, vanes, support, etc. 0.64 mm Aluminum Sheet | BI01010001010000000000000515BI0100001188 | 400 | Sqm |
38 | 39 | SITC Of Acoustic insulation inside the SA Ducts with 10 mm thick F.G. & 36 G perporated aluminium. | BI01010001010000000000000515BI0100001190 | 190 | Sqm |
39 | 40 | SITC of Thermal insulation over the duct with nitrile rubber without aluminum foil fire retradant insulation of 13 mm thickness. | BI01010001010000000000000515BI0100001191 | 400 | Sqm |
40 | 41 | Supply Air Grill and Return Air Grill SITC OF Dynacraft/metal forge/carryair or equivalent make linear grills or extruded aluminium section finished with power coated or approved colour. Supply Air Grill and Return Air Grill | BI01010001010000000000000515BI0100001192 | 20 | Sqm |
41 | 42 | Instalation & Others Inter Connecting communication shielded Cable with Propper PVC Conduting 1.5sqmmx2 core | BI01010001010000000000000515BI0100001193 | 300 | Rft |
42 | 43 | SITC OF PCC Base/MS Platform | BI01010001010000000000000515BI0100001194 | 4 | Each |
43 | 44 | Commissioning ,testing ,balancing the system & handling over the same to the owner in satisfactory working condition For AHU SYSTEM. | BI01010001010000000000000515BI0100001195 | 20 | TR |
44 | 45 | Machine lifting and shifting,Chiping,wall cutting as required | BI01010001010000000000000515BI0100001196 | 1 | Lot |
45 | 46 | SITC OF refregerent gas | BI01010001010000000000000515BI0100001197 | 20 | Kg |
46 | 47 | scraf folding and other civil work as required | BI01010001010000000000000515BI0100001198 | 1 | Lot |
47 | 48 | SITC Power Supply Pvc Insulated XLPE Armoured Copper cable require to run from HVAC Pannel to the Isolater box naer the Outdoor unit.Make:- Havells/ polycab/ Glostar/ KEI. or equivalent as per the direction of Engineer-in-charge 4 X 10sqmm | BI01010001010000000000000515BI0100001199 | 100 | Rmt |
48 | 49 | SITC Of ODU Power Distrubution board suitable to mount in the outside exposed wall | BI01010001010000000000000515BI0100001200 | 2 | Each |