Preventive And Breakdown Maintenance Of Hp/Lp Valves Preventive And Breakdown Maintenance Of Hp/Lp Valves Of Turbine Side Of Unit No 4 And 5 2X500 Mw Btps Anpara, ANPARA THERMAL POWER PROJECT ANPARA SONEBHADRA UP-Uttar Pradesh

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited-UPRVUNL has published Preventive And Breakdown Maintenance Of Hp/Lp Valves Preventive And Breakdown Maintenance Of Hp/Lp Valves Of Turbine Side Of Unit No 4 And 5 2X500 Mw Btps Anpara. Submission Date for this Tender is 28-07-2021. Valve Tenders in ANPARA THERMAL POWER PROJECT ANPARA SONEBHADRA UP Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28242893
Preventive And Breakdown Maintenance Of Hp/Lp Valves Preventive And Breakdown Maintenance Of Hp/Lp Valves Of Turbine Side Of Unit No 4 And 5 2X500 Mw Btps Anpara
Open Tender
Indian
Uttar Pradesh
ANPARA THERMAL POWER PROJECT ANPARA SONEBHADRA UP
28-07-2021

Tender Details

Preventive And Breakdown Maintenance Of Hp/Lp Valves Preventive And Breakdown Maintenance Of Hp/Lp Valves Of Turbine Side Of Unit No 4 And 5 2X500 Mw Btps Anpara

Key Value

Document Fees
INR 590 /-
EMD
INR 14000.0 /-
Tender Value
INR 6.91 Lakhs /-

BOQ Items

Name of Work: Preventive & Breakdown Maintenance of HP/LP Valves of Turbine side of Unit No. 4&5, 2X500 MW, ‘B’ TPS, Anpara
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Servicing of motor operated M-BFP discharge isolation valves, control & isolating valves on feed water lines, Ist/IInd discharge NRVs of M-BFP, manually operated gate/globe valves installed of HP lines on Turbine side. Size: 250~300mm, Design press.: > 40 Kg/cm2, temp.: 250 oC 3 No.
2 2 Servicing of motor operated discharge isolation valve, Ist / IInd. discharge NRVs of T-BFPs, control & isolating valves on feed water lines. Size:350 mm, Design press.: 219~302 Kg/cm2, temp.:210 oC 2 No.
3 3 Servicing of feed water minimum flow isolation valves, pneumatically operated control valves on Turbine side. Size:150 mm, Pr. : 219~224 Kg/cm2 4 No.
4 4 Servicing of motor operated control valve, motor operated gate/globe valves, manually operated gate/globe valves, check valves Size:150~250 mm & manually operated valves of Size: 15~100mm installed on HP lines. motor operated valves. Size: 25~100 mm Pr.> 40 Kg/cm2 2500 mm
5 5 Servicing of hydraulic operated HP Bypass spray water control valves, spray isolation valves, NRVs on Turbine side. Size:100-150mm, Pr. : 152 Kg/cm2. 3 No.
6 6 Servicing of HPH 5A, 5B, 6A, 6B Extraction steam valve, check valves. Size: 250mm, Pr.: 40~51Kg/cm2 3 No.
7 7 Servicing/Overhauling of CRH reverse current valve. Size:900mm, Pr:51 Kg/cm2 1 No.
8 8 Replacement of HP / LP valves of different Floors by cutting of damaged valve & welding of new valve. Size: 08~25 mm. 300 mm
9 9 Replacement of flange gasket of HP/LP valves & piping on per mm dia.basis of valve. 3000 mm
10 10 Replacement of gland packing with new one of HP / LP Valves on per mm dia. basis of valve. 2000 mm
11 11 Replacement of HP / LP Heater man hole flange gasket. 1 No.
12 12 Servicing of HPH - 5A/5B, 6A/6B, LPH-2&3, deaerator & Gland steam header safety valve. 3 No.
13 13 Servicing of suction relief valves of T-BFPs / M-BFPs / CEPs / LPHs / HPHs and safety valves of main air ejectors. 4 No.
14 14 Servicing of motor operated/control & isolation valves installed on LP lines. Size: 25~100mm, Pr. <40 Kg/cm2. 1200 mm
15 15 Servicing of motor operated / control & isolation valves installed on LP lines. Size: 150~200mm, Press<40 Kg/cm2. 1500 mm
16 16 Servicing of motor operated/control & isolation valves installed on LP lines. Size: 250~650 mm, Press<40 Kg/cm2. 5500 mm
17 17 Servicing of mannual operated gate/globe valves & NRVs installed on LP lines. Size: 15~100mm, Pr. <40 Kg/cm2. 8000 mm
18 18 Servicing of mannual operated gate/ globe valves & NRVs installed on LP lines. Size:150~350mm, Press<40 Kg/cm2. 8000 mm
19 19 Servicing of mannual operated gate/ globe valves & NRVs installed on LP lines. Size: 400~650mm, Press < 40 Kg/cm2. 2 No.
20 20 Servicing of steam drain trap valve. Size: 40~50mm, Pr. < 40Kg/cm2. 1 No.
21 21 Revisioning/ Servicing of Butterfly valves installed on ACW System & Gland steam system.Size:150~350mm. 1000 mm
22 22 Revisioning / Servicing of Butterfly valves of ACW System. Size: 450~750mm 1000 mm
23 23 Revisioning / Servicing of NRVs installed on ACW System. Size: 500mm. 4 No.
24 24 Revisioning / Servicing of NRVs installed on SRW System. Size: 750mm. 4 No.
25 25 Servicing of gear boxes of various valves installed on ACW System, feed water, condensate & steam line. Valve Size: 100~750 mm. 3 No.
26 26 Servicing of gear boxes of various valves provided at condenser inlet & outlet in CW line and BFP-T exhaust to condenser. Valve Size: 1350-2100 mm. 1 No.
27 27 Revisioning/Servicing of butterfly valves of BFP-T exhaust to condenser. Size:1350 mm. 1 No.
28 28 Revisioning/Servicing of butterfly valves provided at condenser inlet & outlet in circulating water line. Size:2100 mm. 1 No.
29 29 Welding/repair of LP pipings attending leakages of pipe lines & headers etc. by cutting the damaged portions. 400 mm
30 30 Revisioning / Servicing of Ventilator valve. 1 No.
31 31 Replacement of flange type gate/globe valves of M-BFP & T-BFP oil coolers / LP lines Size: 80 -100 mm 2 No.
32 32 Replacement of butt welded gate/globe valves of M-BFP & T-BFP oil coolers/LP lines Size: 80-100 mm 2 No.
33 33 Revisioning/Servicing of NRVs installed on sump pump pipe lines on Turbine side. Size: 50-100 mm. 2 No.
34 34 Revisioning / Servicing of Ball Collector of Condenser Tube Cleaning System. 1 No.
35 35 Inspection/minor repairing of ball catch strainer of condenser tube cleaning system installed inside CW return line of size:2100 mm 1 No.
36 36 Revisioning/Servicing of ball type valves installed on condenser tube cleaning system on Turbine side. Size:15-40 mm. 1 No.
37 37 Revisioning/Servicing of ball type valves installed on condenser tube cleaning system on Turbine side. Size: 65 -100 mm. 1 No.
38 38 Inside inspection and minor repairing of HP/LP Flash Tanks. 1 No.
39 39 Inspection/Repairing of nozzle of starting air ejector. 1 No.
40 40 Replacement of HP / LP valves of different Floors by cutting of damaged valve & welding of new valve. Size: 40~65 mm. 2 No.
41 41 Inspection and O/H of nozzles of Steam Jet Air Ejector. 1 No.
42 42 Inside inspetion of CW outlet duct by opening of its manhole 1 No.
43 43 Revisioning / Servicing of HP Heater Bypass Valve BF-031-EGV 1 No.
44 44 Revisioning / Servicing of Isolating valve for Superheater spray water SP-031-MGV 1 No.