| 1 | 1 | Tightening of GI J or L hooks in AC sheet/ GI sheet roofing including removal of clotted bitumastic compound wherever necessary, arresting roof leakage by providing and applying bitumastic compound of approved brand and bitumen/ GI washers and other roof leaking arresting materials wherever required over J bolts including providing safety measures for the labourers to work at higher elevation viz., ropes etc., insurance coverage for labourers and hiring of required T&P etc complete. \n | | 1500 | Each |
|---|
| 2 | 2 | Providing and Laying tarfelt/ plastic felt/ bitumen felt sheet with Shalibond CS over AC sheet roofing wherever necessary including providing and applying Shalibond CS & Bitumen felt :Type 3 grade 1 of approved brand wherever required over roof including providing necessary safety measures for the labourers to work at higher elevation, ropes etc., insurance coverage for labourers and hiring of requiring T&P etc complete. | | 90 | Sqm |
|---|
| 3 | 3 | Tightening of EPDM Screws in GI Profile sheet roofing including fixing of missing Screws ,arresting roof leakage by providing and applying Sealant compound / GI washers and other roof leaking arresting materials wherever required over EPDM Screws including providing safety measures for the labourers to work at higher elevation viz., ropes etc., insurance coverage for labourers and hiring of required T&P etc complete. \n | | 1050 | Each |
|---|
| 4 | 4 | Cleaning of Service drains around godowns in all depths and width 0.30m including removal of debris/ rubbish and disposal of the same in all leads and lifts filling in low lying areas and levelling complete in the depot premises as directed by the Engineer-in-charge and the drain to be kept clean during the period of monsoon.\n | | 1104 | Mtr |
|---|
| 5 | 5 | Cleaning of Storme water drains in all depths and width 0.60m to 1.00m including removal of debris/ rubbish and disposal of the same in all leads and lifts filling in low lying areas and levelling complete in the depot premises as directed by the Engineer-in-charge and the drain to be kept clean during the period of monsoon.\n | | 790 | Mtr |
|---|
| 6 | 6 | Providing and replacing 6 mm thick corrugated AC sheets in roofing including dismantling broken AC sheet upto any pitch and fixing with G I J or L hooks bolts and nuts 8 mm dia GI plain and bitumen washers etc. complete as per directions of Engineer-in-charge (excluding the cost of purlins, rafters and trusses) including cutting sheets to size and shape wherever required.\n | | 84 | Sqm |
|---|
| 7 | 7 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking outjoints and preparing and plastering the surface of the walls complete,including disposal of rubbish to the dumping ground within 50 metres lead : With cement mortar 1:4 (1 cement : 4 fine sand) | | 60 | Sqm |
|---|
| 8 | 8 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading etc for a lead up to 1 Km. | | 320 | Cum |
|---|
| 9 | 9 | Supply of rolling shutter springs of 27.5 cm long wire spring grade no.2 for rolling shutters including labour charges etc. | | 16 | Each |
|---|
| 10 | 10 | Servicing to the rolling shutters including cleaning the side guides , springs and shaft etc., with kerosene oil, providing and applying fresh grease, applying tension to the springs replacing damaged parts and welding locking plates stoppers etc., wherever necessary etc complete as directed by the Engineer -in- Charge(Rolling shutters parts like laths, springs etc.. will be supplied at free of cost ) | | 98 | Each |
|---|
| 11 | 11 | Supplying at site rolling shutter made of 80x1.25mm machine rolled lathes/ bottom plates arrangement for inside and outside locking with push and pull operation etc.complete of required thickness etc. for rolling shutters\n | | 5.7 | Sqm |
|---|
| 12 | 12 | Demolishing cement concrete manually/ by mechanical means\nincluding disposal of material within 50 metres lead as per direction\nof Engineer - in - charge. | | 10.1 | Cum |
|---|
| 13 | 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | | 20.32 | Cum |
|---|
| 14 | 14 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) | | 125 | Sqm |
|---|
| 15 | 15 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. | | 3.82 | Cum |
|---|
| 16 | 16 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | | 1.2 | Cum |
|---|
| 17 | 17 | Providing and laying cement concrete in retaining walls, return walls walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone\naggregate 20 mm nominal size) | | 1.2 | Cum |
|---|
| 18 | 18 | Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand) | | 3.42 | Cum |
|---|
| 19 | 19 | Demolishing stone rubble masonry manually/ by mechanical means\nincluding stacking of serviceable material and disposal of\nunserviceable material within 50 metres lead as per direction of\nEngineer-in-charge :In cement mortar | | 11.2 | Cum |
|---|
| 20 | 20 | Centering and shuttering including strutting, propping etc. and removal\nof form work for : Foundations, footings, bases for columns | | 25 | Sqm |
|---|
| 21 | 21 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | | 180 | Sqm |
|---|
| 22 | 22 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc complete | | 9.7 | Sqm |
|---|
| 23 | 23 | Dismantling tile work in floors and roofs laid in cement mortar including\nstacking material within 50 metres lead.\n For thickness of tiles 10 mm to 25 mm sqm | | 56 | Sqm |
|---|
| 24 | 24 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. | | 20 | Sqm |
|---|
| 25 | 25 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | | 36 | Sqm |
|---|
| 26 | 26 | Providing and fixing white vitreous china pedestal type water closet\n(European type W.C. pan) with seat and lid, 10 litre low level white\nP.V.C. flushing cistern, including flush pipe, with manually controlled\ndevice (handle lever), conforming to IS : 7231, with all fittings and\nfixtures complete, including cutting and making good the walls and\nfloors wherever required :W.C. pan with ISI marked white solid plastic seat and lid | | 7 | each |
|---|
| 27 | 27 | Providing and fixing white vitreous china flat back or wall corner type\nlipped front urinal basin of 430x260x350 mm or 340x410x265 mm\nsizes respectively. | | 6 | each |
|---|
| 28 | 28 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, This includes jointing of pipes & fittings with one step CPVC solvent, cement, and testing of joints complete as per direction of Engineer in Charge. internal Work Exposed on wall. 20 mm nominal outer dia Pipes | | 60 | Mtr |
|---|
| 29 | 29 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, This includes jointing of pipes & fittings with one step CPVC solvent, cement, and testing of joints complete as per direction of Engineer in Charge. internal Work Exposed on wall. 32 mm nominal outer dia Pipes | | 10 | Mtr |
|---|
| 30 | 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundation and plinth in: 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) | | 1.5 | Mtr |
|---|
| 31 | 31 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | | 2000 | per litre |
|---|
| 32 | 32 | Cleaning of under ground sump, Over Head R.C.C.Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i)Tank shall be emptied of water by pumping & bottom shall becleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughlywith wire brush etc. and pressure washed with water (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all looseparticles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc.as per direction of Engineer-in-Charge. | | 37 | Sqm |
|---|
| 33 | 33 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) | | 54 | Sqm |
|---|
| 34 | 34 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface | | 425 | Sqm |
|---|
| 35 | 35 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour | | 1477.8 | Sqm |
|---|
| 36 | 36 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 3.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) | | 15 | Cum |
|---|
| 37 | 37 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | | 4.48 | Cum |
|---|
| 38 | 38 | 15 mm cement plaster on the rough side of single or half brick wall ofmix :1:6 (1 cement: 6 fine sand) sqm | | 74 | Sqm |
|---|
| 39 | 39 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) | | 74 | Sqm |
|---|
| 40 | 40 | Providing & fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+.05%) total coated thickness , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | | 10 | Sqm |
|---|
| 41 | 41 | Supply of services of semi-skilled labour like carpenter, sewer man, plumber etc. on daily rate basis for day-to-day maintenance atleast weekly once as per direction of Engineer-in-charge.\n | | 10 | Each /Day |
|---|
| 42 | 42 | Supply of services of labour like beldar, coolie, helper etc. on daily rate basis for day-to-day maintenance atleast weekly once as per direction of Engineer-in-charge. | | 20 | Each /Day |
|---|
| 43 | 43 | Deduct towards cost of salvage value of dismantled materials received from specified items which shall be issued to contractor and shall be cleared by the cotractor from the site of work with all leads and lifts complete as directed by the EIC as is where is basis Dismantled. RS MS laths, springsetc | | 50 | Kg |
|---|
| 44 | 44 | Deduct towards cost of salvage value of dismantled materials received from specified items which shall be issued to contractor and shall be cleared by the cotractor from the site of work with all leads and lifts complete as directed by the EIC as is where is basis Dismantled AC Sheets | | 50 | Sqm |
|---|