Ioaod Engg Modernisation Of A Site Ro Ms Changanmall Sarawgi And Sons Chapaguri Dist Bongaigaon . Modernisation Of A Site Ro Ms Changanmall Sarawgi And Sons Chapaguri Dist Bongaigaon . , Bongaigaon Assam-Assam

Indian Oil Corporation Limited-IOCL has published Ioaod Engg Modernisation Of A Site Ro Ms Changanmall Sarawgi And Sons Chapaguri Dist Bongaigaon . Modernisation Of A Site Ro Ms Changanmall Sarawgi And Sons Chapaguri Dist Bongaigaon . . Submission Date for this Tender is 01-07-2021. Civil Work Tenders in Bongaigaon Assam Assam. Bidders can get complete Tender details and download the document.




Tender Notice

28232927
Ioaod Engg Modernisation Of A Site Ro Ms Changanmall Sarawgi And Sons Chapaguri Dist Bongaigaon . Modernisation Of A Site Ro Ms Changanmall Sarawgi And Sons Chapaguri Dist Bongaigaon .
Open Tender
Indian
Assam
Bongaigaon Assam
01-07-2021

Tender Details

Ioaod Engg Modernisation Of A Site Ro Ms Changanmall Sarawgi And Sons Chapaguri Dist Bongaigaon . Modernisation Of A Site Ro Ms Changanmall Sarawgi And Sons Chapaguri Dist Bongaigaon .

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 1.33 Crore /-

BOQ Items

Name of Work: Modernisation of “A” Site RO M/s. Changanmall Sarawgi and Sons, Chapaguri, Dist: Bongaigaon, State: Assam.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 LAND DEVELOPMENT : BI01010001010000000000000515BI0100001112
2 1.01 Clearing grass and removal of the rubbish outside site premises and at an unobjectionable place. BI01010001010000000000000515BI0100001113 1746.32 M2
3 1.02 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth within premises BI01010001010000000000000515BI0100001114 1746.32 M2
4 1.04 CONST.OF PUMP PLINTH, INSTALLATION OF PUMPS & PIPELINES : BI01010001010000000000000515BI0100001116
5 1.05 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 BI01010001010000000000000515BI0100001117
6 1.06 i) All kinds of Soil BI01010001010000000000000515BI0100001118 45.04 M3
7 1.07 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001119
8 1.08 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001120 26.086 M3
9 1.09 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth BI01010001010000000000000515BI0100001121 14.154 M2
10 1.1 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001122
11 1.11 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001123 0.611 M3
12 1.12 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001124
13 1.13 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001125 2.29 M2
14 1.14 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001126
15 1.15 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001127 6.233 M3
16 1.16 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001128 2.71 M2
17 1.17 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. BI01010001010000000000000515BI0100001129
18 1.18 iv) Granite of any colour and shade having Area of slab over 0.50 sqm BI01010001010000000000000515BI0100001130 12.86 M2
19 1.19 Extra for providing edge moulding to 18mm Granite/ marble stone counters,Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge. BI01010001010000000000000515BI0100001131
20 1.2 ii) Granite work BI01010001010000000000000515BI0100001132 20 RM
21 1.21 Supply and Laying of 80 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. BI01010001010000000000000515BI0100001133
22 1.22 Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. BI01010001010000000000000515BI0100001134
23 1.23 Supply, fabrication, laying and testing of MS, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL Specifications including pipeline fittings like bends, tee etc as required and as directed for Above Ground pipeline including surface preparation according to standard SSPC ST2 and painting with 2 coats of red oxide zinc phosphate primer and 2 coats of Synthetic enamel / aluminium finish paint as per IOCL specifications BI01010001010000000000000515BI0100001135
24 1.24 iv) S/L Threaded A/G HD MS Pipes of 40 mm dia with fittings,Painting BI01010001010000000000000515BI0100001136
25 1.25 Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor) BI01010001010000000000000515BI0100001137
26 1.26 viii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos,0-30 Km BI01010001010000000000000515BI0100001138
27 1.27 ix) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos, Add extra for every additional Km above 30km BI01010001010000000000000515BI0100001139
28 1.28 xii) MPD/MPP pumps upto 2 nos., 0-30 Km BI01010001010000000000000515BI0100001140
29 1.29 xii) MPD/MPP pumps upto 2 nos., Add extra for every additional Km above 30km BI01010001010000000000000515BI0100001141
30 1.3 Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, including supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump BI01010001010000000000000515BI0100001142
31 1.31 i) 2 product - 4 nozzle MPPs/MPDs BI01010001010000000000000515BI0100001143 2 EA
32 1.32 Installation of Corporation supplied Standard Submersible Turbine Pump on the existing Manhole Cover as per drawing and direction of Engineer in Charge BI01010001010000000000000515BI0100001144
33 1.33 Supply & welding slip-on flanges conforming to IS2062 GrA, ANSI B16.5, Class#150 with 3 runs of weld outside and one run of weld inside the flanges as per specifications and standard Drg.enclosed herein BI01010001010000000000000515BI0100001145
34 1.34 iii) S/W Slipon flanges of 50 mm dia. conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein BI01010001010000000000000515BI0100001146 4 EA
35 1.35 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001147
36 1.36 iii) 3 Core x 1.5 sq. mm. (copper) BI01010001010000000000000515BI0100001148 120 M
37 1.37 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001149 140 M
38 1.38 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001150
39 1.39 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001151 10 EA
40 1.4 Chemical Earthing with Copper Bonded Rod suitable for current carrying capacity of 15kA for 1 second - Supply of chemical earthing Cu Bonded High Tensile Low Carbon Steel Rod of dia not less than 17mm electrode complying to UL 467 Requirements & suitable for current carrying capacity of 15kA for 1 second, exothermic welded & 3Mtr long BI01010001010000000000000515BI0100001152 4 EA
41 1.41 Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : BI01010001010000000000000515BI0100001153
42 1.42 i) 50 x 10mm G.I. Strip BI01010001010000000000000515BI0100001154 200 M
43 1.43 ii) 32 x 6 mm G.I.strip BI01010001010000000000000515BI0100001155 120 M
44 1.44 x) 8 S.W.G. Cu. Wire BI01010001010000000000000515BI0100001156 65 M
45 1.45 MINIATURE CIRCUIT BREAKERS (MCB) Supplying & fixing of Miniature Circuit Breakers as per approved make of 10KA Breaking cpacity of following ratings BI01010001010000000000000515BI0100001157
46 1.46 ii) 6A to 32A SPN MCB BI01010001010000000000000515BI0100001158 6 EA
47 1.47 MCB DISTRIBUTION BOARD INCLUSIVE OF SINGLE PHASE MCB Supply & fixing of MCB Distribution Board double door type, IP-42, inclusive of MCB, Single Phase, as per approved make of following types with all accessories such as tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs, etc. (MCB - 10KA Breaking Capacity) BI01010001010000000000000515BI0100001159
48 1.48 ii) 12 way DB with 32A DP as incoming-1No.& 6to16ASP as outgoing-12No BI01010001010000000000000515BI0100001160 1 EA
49 1.49 Supply of Galvanised Fire buckets of 9 litre capacity, painted white inside and red outside with letters 'fire' in black, conforming to IS 2546-1974. BI01010001010000000000000515BI0100001161
50 1.5 Supplying Fire bucket stand- 4 buckets hanging arrangement 1 meter height, made of 50x50x6mm angle frame, painted with 2 coats of primer and 2 coats of Red, synthetic enamel paint. BI01010001010000000000000515BI0100001162
51 1.51 Supplying and fixing of 4.5kg CO2 fire extinguisher of approved make Conforming to IS 15683, portable high pressure type. Body seamless Manganese Steel, ISI marked conforming to IS 7285, discharge valve conforming to IS 324,polyethylene flat discharge horn with diffuser,1m wire braded rubber hose, powder coated wall mounting mild steel bracket,stainless steel safety pin of SS 316 grade, CO2 gas with 99.5% purity. Extinguisher shall have anti corrosive treatment of phosphating by hot dipping process to thickness not less than 0.012mm both internally and externally. Epoxy polyester powder coating of minimum 50 micron to all metallic external parts with two bands of yellow colored fluorescent adhesive tape of minimum 20mm thickness of body. Finish of the paint to be PO red as per shade 538 of IS:5 BI01010001010000000000000515BI0100001163
52 1.52 Supplying and fixing of 9kg DCP portable,cartridge type Fire extinguisher of approved make,Conforming to IS15683:2006,Body Carbon Steel as per IS:513,EDD grade with no vertical weld joint on the body Neck ring of seamless mild steel tube conforming to IS 1239 part-1, Valve assembly conforming to SS 316 grade or forged brass as per IS 6912 grade FLB, Inlet and outlet siphon tubes of SS 316 grade or of brass as per IS 407, Discharge nozzle of SS 316 grade of forged brass as per IS 6912, 500mm long discharge hose of EDPM rubber, powder coated wall mounting mild steel bracket,stainless steel safety Pin of SS 316 grade, Dry Chemical powder ( potassium bi-carbonate & Minimum 90% of the total chemical), ISI marked CO2 Gas cartridge of 200 gms, dia of the body 175mm +/- 10mm & overall height less than 650mm.Extinguisher shall have anticorrosive treatment of phosphating by hot dipping process to thickness not less than 0.012mm both internally & externally. Epoxy polyester powder coating of minimum 50 micron to all metallic external parts with two bands of yellow colored fluorescent adhesive tape of minimum 20mm thickness of body. Finish of the paint to be PO red as per shade 538 of IS:5 BI01010001010000000000000515BI0100001164
53 1.53 Providing alteration to Manhole Covers for Fixing Submersible Turbine Including Fixing of 100mm diax 150 to 200mm long C class threaded Barrel Nipple , 100mm dia x 100 mm long coupler , 2 nos 100mm dia Class 150 threaded MS flange, 3mm thick packing sheet, nuts and bolts, 3mm thick permanite oil packing gasket to manhole cover, cutting of the manhole cover for fixing nipples etc. at workshop including transportation etc. BI01010001010000000000000515BI0100001165
54 1.54 iii) Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework. BI01010001010000000000000515BI0100001166
55 1.55 iii) Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework. BI01010001010000000000000515BI0100001167 1 EA
56 1.56 Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job) BI01010001010000000000000515BI0100001168 4 EA
57 1.57 THREE PHASE SERVO STABILIZER Supplying and fixing of 3 phase air cooled servo stabilizer for balanced and unbalanced load shall be independent correction of each phase (Range 300 - 460 V minimum) and as per specification BI01010001010000000000000515BI0100001169
58 1.58 v) 30 KVA stabilizer BI01010001010000000000000515BI0100001170 1 EA
59 1.6 CONSTRUCTION OF BUFFER STRIP : BI01010001010000000000000515BI0100001172
60 1.61 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 BI01010001010000000000000515BI0100001173
61 1.62 i) All kinds of Soil BI01010001010000000000000515BI0100001174 11.25 M3
62 1.63 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001175
63 1.64 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001176 37.5 M3
64 1.65 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth BI01010001010000000000000515BI0100001177 12.5 M2
65 1.66 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001178
66 1.67 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001179 3.75 M3
67 1.68 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001180
68 1.69 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001181 30 M2
69 1.7 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001182
70 1.71 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001183 331.59 KG
71 1.72 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001184
72 1.73 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001185 13.283 M3
73 1.74 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001186
74 1.75 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001187 57.5 M2
75 1.76 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001188 57.5 M2
76 1.78 CONSTRUCTION OF CULVERT & OPEN DRAIN : BI01010001010000000000000515BI0100001190
77 1.79 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 BI01010001010000000000000515BI0100001191
78 1.8 i) All kinds of Soil BI01010001010000000000000515BI0100001192 183.249 M3
79 1.81 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth BI01010001010000000000000515BI0100001193 122.166 M2
80 1.82 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001194
81 1.83 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001195 55.575 M3
82 1.84 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001196
83 1.85 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001197 97.774 M2
84 1.86 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001198
85 1.87 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001199 4709.24 KG
86 1.88 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001200
87 1.89 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001201 22.071 M3
88 1.9 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001202 4977.7 KG
89 1.91 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001203
90 1.92 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001204 100.896 M2
91 1.93 Providing Neat cement punning BI01010001010000000000000515BI0100001205 100.896 M2
92 1.94 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. BI01010001010000000000000515BI0100001206
93 1.95 ii) 110 mm diameter BI01010001010000000000000515BI0100001207 10 M
94 1.97 CONSTRUCTION OF SALES BUILDING : BI01010001010000000000000515BI0100001209
95 1.98 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 BI01010001010000000000000515BI0100001210
96 1.99 i) All kinds of Soil BI01010001010000000000000515BI0100001211 30.24 M3
97 2 Supply & filling of local earth (including royalty) by mechanical transport also including ramming & watering of the earth in layers not exceeding 20cm in depth in plot, trenches, plinth, sides of foundations etc. complete BI01010001010000000000000515BI0100001212 14.429 M3
98 2.01 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001213
99 2.02 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001214 30.513 M3
100 2.03 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil BI01010001010000000000000515BI0100001215 6.098 M2
101 2.04 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth BI01010001010000000000000515BI0100001216 57.55 M2
102 2.05 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001217
103 2.06 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001218 7.17 M3
104 2.07 Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : BI01010001010000000000000515BI0100001219
105 2.08 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001220 16.387 M3
106 2.09 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001221
107 2.1 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001222 32.378 M2
108 2.11 iii) Suspended floors,roofs,landings,balconies, access platform and Shelves (Cast in situ) BI01010001010000000000000515BI0100001223 66.861 M2
109 2.12 iv) Lintels, beams plinth beams,girders bressumers and cantilevers BI01010001010000000000000515BI0100001224 8.424 M2
110 2.13 v) Columns, Pillars, Piers, Abutments, Posts and Struts. BI01010001010000000000000515BI0100001225 34.234 M2
111 2.14 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001226
112 2.15 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001227 2173.79 KG
113 2.16 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001228
114 2.17 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001229 10.935 M3
115 2.18 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001230 58.722 M2
116 2.19 Providing and fixing 150 mm bright finished chrome plated brass hanging type floor door stopper with rubber cushion necessary brass screws, etc. complete. to suit shutter thickness complete BI01010001010000000000000515BI0100001231 2 EA
117 2.2 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. BI01010001010000000000000515BI0100001232 2 EA
118 2.21 Providing & fixing chromium plated brass 100mm mortice latch & lock with 6 levers & a pair of lever handles with necessary screws etc complete (best make of approved quality). BI01010001010000000000000515BI0100001233 2 EA
119 2.22 Providing and fixing factory made 30mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75mm x 30mm having wall thickness 5mm. The styles, top & bottom rails shall have one side wall thickness of 15mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with MS tubes of size 33mm x 17mm x 1mm painted with primer, all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and rails with a cavity to receive single piece extruded 5mm PVC sheet as panel. The styles and rails shall be mitred cut and joint with help of PVC solvent cement and self tapping screws. Single piece extruded solid PVC lock rail of size 100mm x 30mm with wall thickness 5mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8mm complete as per manufacturer's specifications and direction of Engineer-in-charge BI01010001010000000000000515BI0100001234
120 2.23 i) Non Decorative finish BI01010001010000000000000515BI0100001235 3.2 M2
121 2.24 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001236 64.588 KG
122 2.25 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover BI01010001010000000000000515BI0100001237 31.68 M2
123 2.26 Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement BI01010001010000000000000515BI0100001238 27.6 M2
124 2.27 Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade. BI01010001010000000000000515BI0100001239 30.24 M2
125 2.28 Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete. BI01010001010000000000000515BI0100001240 6 M2
126 2.29 Providing & laying double charged,full body vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tiles 60x60 Cm. BI01010001010000000000000515BI0100001241
127 2.3 Size of Tiles 60x60 Cm. BI01010001010000000000000515BI0100001242 30.75 M2
128 2.31 25mm Thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) BI01010001010000000000000515BI0100001243 6 M2
129 2.32 Providing & fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work & fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. BI01010001010000000000000515BI0100001244
130 2.33 ii) 110 mm BI01010001010000000000000515BI0100001245 16 M
131 2.34 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001246
132 2.35 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001247 118.164 M2
133 2.36 iii) 15mm Cement plaster of mix 1:4 (1 cement: 4 fine sand) on rough side of half or single brick wall BI01010001010000000000000515BI0100001248 43.263 M2
134 2.37 Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001249
135 2.38 i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand) BI01010001010000000000000515BI0100001250 42.959 M2
136 2.39 Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete BI01010001010000000000000515BI0100001251 204.386 M2
137 2.4 Finishing walls with textured exterior paint of required shade (2 or more coats applied @ 3.28 ltr/10 sqm, over and including priming coat of exterior Primer applied @ 2.20kg/10 sqm) BI01010001010000000000000515BI0100001252 43.263 M2
138 2.41 Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm BI01010001010000000000000515BI0100001253 161.123 M2
139 2.42 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001254 26.19 M2
140 2.43 Providing and fixing water closet squatting pan (Indian type W.C.pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C.flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required -White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. BI01010001010000000000000515BI0100001255
141 2.44 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white PVC flushing cistern including flush pipe with manually controlled device (handle lever),conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required: BI01010001010000000000000515BI0100001256
142 2.45 i) W.C. pan with ISI marked white solid plastic seat and lid BI01010001010000000000000515BI0100001257 2 EA
143 2.46 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : BI01010001010000000000000515BI0100001258
144 2.47 i) One urinal basin with 5 litre white P.V.C. automatic flushing cistern BI01010001010000000000000515BI0100001259 2 EA
145 2.48 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : BI01010001010000000000000515BI0100001260
146 2.49 i) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps BI01010001010000000000000515BI0100001261 2 EA
147 2.5 Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. BI01010001010000000000000515BI0100001262 2 EA
148 2.51 Providing and fixing toilet paper holder : BI01010001010000000000000515BI0100001263
149 2.52 i) C.P. brass BI01010001010000000000000515BI0100001264 2 M
150 2.53 Providing and fixing soil, waste and vent pipes : BI01010001010000000000000515BI0100001265
151 2.54 i) 100mm dia Sand cast iron S&S pipe as per IS: 1729. BI01010001010000000000000515BI0100001266 4 EA
152 2.55 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall BI01010001010000000000000515BI0100001267
153 2.56 i) 15 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001268 30 M
154 2.57 ii) 20 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001269 25 M
155 2.58 iii) 25 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001270 15 M
156 2.59 Providing and fixing B class G.I. pipes complete with G.I. fittings & clamps, i/c cutting & making good the walls etc. Internal work Exposed on wall. BI01010001010000000000000515BI0100001271
157 2.6 ii) 20 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001272 25 M
158 2.61 iii) 25 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001273 15 M
159 2.62 Providing and fixing brass bib cock of approved quality : BI01010001010000000000000515BI0100001274
160 2.63 i) 15 mm nominal bore BI01010001010000000000000515BI0100001275 6 EA
161 2.64 Providing and fixing brass stop cock of approved quality : BI01010001010000000000000515BI0100001276
162 2.65 i) 15 mm nominal bore BI01010001010000000000000515BI0100001277 6 EA
163 2.66 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : BI01010001010000000000000515BI0100001278
164 2.67 i) 25 mm nominal bore BI01010001010000000000000515BI0100001279 2 EA
165 2.68 Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank BI01010001010000000000000515BI0100001280 1000 L
166 2.69 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) BI01010001010000000000000515BI0100001281
167 2.7 i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections BI01010001010000000000000515BI0100001282 92.275 KG
168 2.71 ii) Fixed glazing with Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) sections BI01010001010000000000000515BI0100001283 0.546 KG
169 2.72 iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) BI01010001010000000000000515BI0100001284 44.615 KG
170 2.73 Providing and fixing panelling or panelling and glazing in panelled or panelled & glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : BI01010001010000000000000515BI0100001285
171 2.74 ii) 12mm thick particle board with Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS:3097, Grade I BI01010001010000000000000515BI0100001286 3.36 M2
172 2.75 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): BI01010001010000000000000515BI0100001287
173 2.76 ii) With float glass panes of 5.0 mm thickness (weight not less than 12.5kg/sqm) BI01010001010000000000000515BI0100001288 36.961 M2
174 2.77 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. BI01010001010000000000000515BI0100001289
175 2.78 i) With stainless steel cover plate BI01010001010000000000000515BI0100001290 2 EA
176 2.79 Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceilings, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001291
177 2.8 ii) Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) BI01010001010000000000000515BI0100001292 4 EA
178 2.81 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc. complete as per direction of Engineer-in-Charge. BI01010001010000000000000515BI0100001293
179 2.82 ii) Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar BI01010001010000000000000515BI0100001294 4 EA
180 2.83 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). BI01010001010000000000000515BI0100001295 4.2 M2
181 2.84 Cruse set, for PH toilet : Supplying & providing Wash Basin BI01010001010000000000000515BI0100001296
182 2.85 CONSTRUCTION OF SEPTIC TANK & SOAK PIT :- BI01010001010000000000000515BI0100001297
183 2.86 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 BI01010001010000000000000515BI0100001298
184 2.87 i) All kinds of Soil BI01010001010000000000000515BI0100001299 17.145 M3
185 2.88 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth BI01010001010000000000000515BI0100001300 6.218 M2
186 2.89 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001301
187 2.9 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001302 0.67 M3
188 2.91 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001303
189 2.92 iii) Suspended floors,roofs,landings,balconies, access platform and Shelves (Cast in situ) BI01010001010000000000000515BI0100001304 5.23 M2
190 2.93 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001305
191 2.94 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001306 99.082 KG
192 2.95 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001307
193 2.96 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001308 4.078 M3
194 2.97 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001309
195 2.98 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001310 18.003 M2
196 2.99 Providing Neat cement punning BI01010001010000000000000515BI0100001311 29.628 M2
197 3 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001312
198 3.01 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001313 23.475 M2
199 3.03 ELECTRIFICATION OF SALES BUILDING : BI01010001010000000000000515BI0100001315
200 3.04 PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. BI01010001010000000000000515BI0100001316
201 3.05 Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL. BI01010001010000000000000515BI0100001317 1 EA
202 3.06 PROVIDING INTERNAL WIRING BI01010001010000000000000515BI0100001318
203 3.07 i) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. BI01010001010000000000000515BI0100001319 40 EA
204 3.08 Providing following point wiring with standard wire/ cable, plug, fittings, with suitable sockets, suitable GI box with front plate etc. complete, to include circuits from distribution boards to individual point boards, suitable PVC casing capping and required accessories pulling of wires, etc. complete. BI01010001010000000000000515BI0100001320
205 3.09 i) Supplying and drawing following 2 pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. BI01010001010000000000000515BI0100001321 18 M
206 3.1 Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make BI01010001010000000000000515BI0100001322
207 3.11 i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire BI01010001010000000000000515BI0100001323 60 M
208 3.12 ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire BI01010001010000000000000515BI0100001324 60 M
209 3.13 iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire BI01010001010000000000000515BI0100001325 60 M
210 3.14 iv) 2 x 6 sq mm + 1 x 6 sq mm earth wire BI01010001010000000000000515BI0100001326 55 M
211 3.15 SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001327
212 3.16 iii) 4 module frame BI01010001010000000000000515BI0100001328 6 EA
213 3.17 viii) 15 A Modular switch BI01010001010000000000000515BI0100001329 32 EA
214 3.18 xi) 2 Pin Telephone Modular Socket BI01010001010000000000000515BI0100001330 4 EA
215 3.19 xii) Fan Regulator of stepped modular type BI01010001010000000000000515BI0100001331 3 EA
216 3.2 Supply & fixing of 300mA RCCB of approved Make of following ratings: BI01010001010000000000000515BI0100001332
217 3.21 v) 4 poles, 63A BI01010001010000000000000515BI0100001333 1 EA
218 3.22 Supplying & fixing of approved make 4 pole change over switch in steel sheet enclosure with side handle operation onload type grouting in C.C. Complete as per direction of Engineer-In-Charge. BI01010001010000000000000515BI0100001334
219 3.23 iii) 100 Amps., 4 Pole BI01010001010000000000000515BI0100001335 1 EA
220 3.24 MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive of MCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity) BI01010001010000000000000515BI0100001336
221 3.25 i) S/E 4 way DB with 63A FP RCBO, 300 mA sensitivity as incoming - 1No.& 6 to 16A SP as outgoing - 4 Nos. for each phase. BI01010001010000000000000515BI0100001337 2 EA
222 3.26 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001338 10 EA
223 3.27 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watts with fittings and accessories, having IP20 protection class with CRCA/PC/Aluminium Extrusion housing & with UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer in charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall range from 5700 Kelvin (5665 K +/- 355 K) to 6500 Kelvin, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 80 for indoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 95 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 2kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001339 6 EA
224 3.28 CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: BI01010001010000000000000515BI0100001340
225 3.29 iii) 1200 mm sweep BI01010001010000000000000515BI0100001341 3 EA
226 3.3 EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does not include making suitable cut out in the wall for fixing the fan). BI01010001010000000000000515BI0100001342
227 3.31 ii) 9" dia light duty, make Khaitan or equivalent BI01010001010000000000000515BI0100001343 4 EA
228 3.32 Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works: BI01010001010000000000000515BI0100001344
229 3.33 iii) Horizontal air compressor Assembly of 5 HP (160-220 LITRES) including civil works BI01010001010000000000000515BI0100001345
230 3.34 Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.) BI01010001010000000000000515BI0100001346
231 3.35 Supplying and fixing of MV Lightining Arrestor horn gap type as required BI01010001010000000000000515BI0100001347 1 EA
232 3.36 Formation of lighting protection arrangement with supply of 1.0 M height spike and erection at top most portion of structure/building and connecting the same to earthpit by 40x6mm GI strip (excluding supply and laying of GI strip) BI01010001010000000000000515BI0100001348 1 EA
233 3.38 CONSTRUCTION OF DRVEWAY & APPROACH : BI01010001010000000000000515BI0100001350
234 3.39 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001351
235 3.4 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001352 92.4813 M3
236 3.41 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001353
237 3.42 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001354 6.35 M2
238 3.43 Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge. BI01010001010000000000000515BI0100001355
239 3.44 i) With material confirming to grade-I (size 75 mm to .075 mm) having CBR value - 30, Thickness as desired BI01010001010000000000000515BI0100001356 508.647 M3
240 3.45 Supply and laying of water bound macadam of 100 mm consolidated thickness for subbase with 90 to 45 mm stone aggregate,11.2mm size screenings, chippings of stone and murrum spreading, watering and consolidating in camber with power roller complete as/specifications. BI01010001010000000000000515BI0100001357 1849.62 M2
241 3.46 Supply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer BI01010001010000000000000515BI0100001358 3699.25 M2
242 3.47 Providing & laying factory made reflective type Lacquered finish Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. (Payment for provision of edge restraints shall be made separately) BI01010001010000000000000515BI0100001359
243 3.48 ii) M40 grade 80 mm thick reflective type Lacquered finish BI01010001010000000000000515BI0100001360 1849.62 M2
244 3.49 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001361
245 3.5 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001362 5.4 M3
246 3.51 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001363
247 3.52 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001364 561.391 KG
248 3.53 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement:3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment) (Precast C.C. kerb stone shall be approved by Engineer-in-charge. BI01010001010000000000000515BI0100001365 5 M3
249 3.55 SUPPLY AND INSTALLATION OF YARD LIGHT : BI01010001010000000000000515BI0100001367
250 3.56 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty BI01010001010000000000000515BI0100001368
251 3.57 ii) 150 mm dia. R.C.C. pipe BI01010001010000000000000515BI0100001369 40 M
252 3.58 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001370
253 3.59 i) 2 Core x 1.5 sq. mm. (copper) BI01010001010000000000000515BI0100001371 180 M
254 3.6 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001372 400 M
255 3.61 xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS BI01010001010000000000000515BI0100001373 50 M
256 3.62 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001374
257 3.63 ii) 2 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001375 12 EA
258 3.64 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001376 12 EA
259 3.65 Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : BI01010001010000000000000515BI0100001377
260 3.66 vii) 10 S.W.G. G.I. Wire (bare) BI01010001010000000000000515BI0100001378 60 M
261 3.67 Supplying & fixing of approved make 4 pole change over switch in steel sheet enclosure with side handle operation onload type grouting in C.C. Complete as per direction of Engineer-In-Charge. BI01010001010000000000000515BI0100001379
262 3.68 ii) 63 Amps., 4 Pole BI01010001010000000000000515BI0100001380
263 3.69 OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) : BI01010001010000000000000515BI0100001381
264 3.7 iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) BI01010001010000000000000515BI0100001382 12 EA
265 3.71 Supply, fitting, fixing of arm bracket, tubular type, 38mm/50mm dia on pole including painting, all complete. BI01010001010000000000000515BI0100001383
266 3.72 i) S/E Arm " L " bracket 38/50mm dia on pole, as per specifications and direction of Engineer in charge BI01010001010000000000000515BI0100001384 10 EA
267 3.73 ii) S/E Arm " Y " bracket 38/50mm dia on pole, as per specifications and direction of Engineer in charge BI01010001010000000000000515BI0100001385 2 EA
268 3.74 Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001386
269 3.75 ii) "L" Pole BI01010001010000000000000515BI0100001387 12 EA
270 3.76 Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001388 12 EA
271 3.77 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. All Kinds of Soil BI01010001010000000000000515BI0100001389 10 M3
272 3.78 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth BI01010001010000000000000515BI0100001390 10 M2
273 3.79 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001391
274 3.8 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001392 3.692 M3
275 3.81 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001393 27.35 M2
276 3.82 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001394
277 3.83 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001395 209.415 KG
278 3.85 DEMOLISHING/DISMANTLING ITEMS BI01010001010000000000000515BI0100001397
279 3.86 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars & disposal of unserviceable material outside site to an unobjectionable place as/ direction of Engineer-in-charge BI01010001010000000000000515BI0100001398 42.016 M3
280 3.87 Demolishing brick work manually/mechanical means including stacking of serviceable material & disposal of unserviceable material outside premises at an unobjectionable place as / direction of Engg-in-charge BI01010001010000000000000515BI0100001399 89.657 M3
281 3.88 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001400 36 M2
282 3.89 i) Of area 3 sq. metres and below BI01010001010000000000000515BI0100001401 16 EA
283 3.9 ii) Of area beyond 3 sq. metres BI01010001010000000000000515BI0100001402 2 EA
284 3.91 Removing connected dispensing pump from pedestal including disconnection of pipeline, electrical connection, removal of nuts of the foundation bolts etc. complete. BI01010001010000000000000515BI0100001403 2 EA
285 3.92 iv) Exhuming of tanks of 50 KL Tank BI01010001010000000000000515BI0100001404 1 EA
286 3.93 Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor) BI01010001010000000000000515BI0100001405
287 3.94 v) 50/70 KL Tanks with fittings : 0 - 30 Km BI01010001010000000000000515BI0100001406 1 LS
288 3.95 vi) 50/70 KL Tank with fittings: Add extra for each addtnl. Km above 30km BI01010001010000000000000515BI0100001407 300 KM
289 3.96 iii) Loading/unloading charges for 50/70 KL Tank BI01010001010000000000000515BI0100001408 2 EA