Repair Maintenance Of Control Panels And Misc Repair Of Stp At Af Stn Gurgaon Under Age Em Af Gurgaon Of Ge Af Gurgaon, GE (AF) Gurgaon-Haryana

Military Engineer Services-MES has published Repair Maintenance Of Control Panels And Misc Repair Of Stp At Af Stn Gurgaon Under Age Em Af Gurgaon Of Ge Af Gurgaon. Submission Date for this Tender is 15-07-2021. Control Panel Tenders in GE (AF) Gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

28227062
Corrigendum : Repair Maintenance Of Control Panels And Misc Repair Of Stp At Af Stn Gurgaon Under Age Em Af Gurgaon Of Ge Af Gurgaon
Open Tender
Indian
Haryana
GE (AF) Gurgaon
15-07-2021

Tender Details

Repair Maintenance Of Control Panels And Misc Repair Of Stp At Af Stn Gurgaon Under Age Em Af Gurgaon Of Ge Af Gurgaon

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Jul-2021 Amendment BOQ 08-07-2021
2 08-Jul-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-07-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work : REPAIR /MAINT CONTROL PANELS AND MISC REPAIR OF STP AT AF STN GURGAON UNDER AGE E/M (AF) GURGAON OF GE (AF) GURGAON
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Lifting and taking out the sewage submersible pump set and motor of capacity 10 to 15 HP including column pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from the sewage sump /well and lowering back the pump after repairing /removing the sludge from the pump including making electrical connection with the existing panel /starter and connecting the complete the column pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as directed. \nNote :- Rate are deemed to be inclusive for jointing of Submersible Cable , reconnecting the delivery pipe line of submersible pump sets to water mains , testing for satisfactory running & continuous flow of water complete. 8 Each Job
2 2 All as per item No. 1 desribed here in before but of capacity 2 HP to 7.5 HP complete all as specified and as directed . 10 Each Job
3 3 M&L for electric arc welding at places like flanges/pipe line, joints , strip of clarifier tank, approach ladder to aeration tank etc all as specified and directed by Engineer-in-Charge. 5 Each Job
4 4 M&L for rewinding of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire, varnishing and stamping and overhauling etc. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 10 HP to 15 HP complete all as specified and as directed . 6 Each
5 5 All as per Item No 4 but 5 to 7.5 HP Capacity 7 Each
6 6 M&L for repairing and testing of pump centrifugal/mono block/non clogging upto 5 to 12.5 HP of any make and type including welding work, rotor turning and balancing, re-metaling of shaft bush bearing, keys, mechanincal seal, SS shaft impeller and other such accessories etc required to make pump functional and testing on load complete all as specified and as directed . 5 Each
7 7 M&L for rewinding of electric motor upto 5 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed 5 Each
8 8 M&L for rewinding of electric motor 15 to 20 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes, varnishing and stamping and overhauling. making the winding leak proof etc. and other accessories etc required to make motor functional and testing on load complete all as specified and as directed . 2 Each
9 9 Disconnecting and taking down treated sewage transfer pump set up to 15 HP horizintal type and replacement of urnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire including bearing bushes, mechanical seal rotor tunring & balancing, shaft SS impeller varnishing and stamping and overhauling etc. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter and re-assembling and fixing the pump set complete in the same location and testing all as specified and as directed . 2 Each
10 10 M & L for servicing of air blower with positive displacement type twin lube root blower with Motor of 12.5 HP to 15 HP capacities, including Opening the blower motor blower shaft, shaft Key ways, shaft holes etc and M & L for replacing the gland packing, gland nuts, coupling, replacement of oil seal including oil and rewinding of blower motor with super enameled copper winding wire as per existing size including re-fixing the same to the original position and commissioning testing complete all as specified and as directed . 3 Job
11 11 S & F Fan belt B-45 suitable for Air blower including taking down complete all as specified and directed. 6 Each
12 12 M & L for Periodical Cleaning of equalizing tank /grit chamber/ oil grease chamber/stilling chamber of Sewage Water in the tank and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortor 1:3 where required all as required at site and directed by the Engineer-in-Charge at AF Stn Gurgaon for Sewage tank of STP 500 KLD of under mentioned sizes complete all as specified and directed :- \n(a) Collection tank dia 6m and depth 9m x 4m - (Sump Well/ Equalization tank). (b) Screen/ grid Chamber. (c) Aeration tank - dia-9m and depth 5m. (d) Clarifier - dia 7.4 mtrs and depth 4.5 mtrs. (e) Sludge drying bed of size 10 m x 4.5 m x1.5m. \nNote: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the Delhi Canttonment Board/MCD. (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineerin- Charge. 1 Each Jon
13 13 M & L for Cleaning of filter medial tank (ACF & DMF) , pumping out all sludge and foreign material including washing the entire tank and scraping the walls with wire brushes and making good the patches on walls internally or externally where required all as specified and directed by Engr-in-Charge.\n(Make: MM Aqua/Venayaka Engineers/ Ion Exchange) 2 Each Job
14 14 Supply and pouring Bio media made of plastic and corrugated shape having surface area 260 sqm/cum in MBBR as directed by Engr-in-charge 5 Cum
15 15 Supply only DWPE chemical for sewage treatment plant. 150 Kgs
16 16 Material and labour for replacement of quartz silica sand 32-64 grade complete all as specified and directed by Engr-in-charge. 200 Kgs
17 17 Material and labour for replacement of quartz silica sand 16-32 grade complete all as specified and directed by Engr-in-charge 200 Kgs
18 18 Material and labour for replacement of quartz silica sand 8-16 grade complete all as specified and directed by Engr-in-charge. 200 Kgs
19 19 Material and labour for replacement of quartz silica sand 4-8 grade complete all as specified and directed by Engr-in-charge. 200 Kgs
20 20 Material and labour for replacement of activated carbon IV 1000 complete all as specified and directed by Engr-in-charge. 100 Kgs
21 21 Taking out complete pebbles from the filter and and refilling the same pebbles after washing /cleaning thoroughly complete all as specified and directed by Engr-in-charge. 2 Cum
22 22 M & L for Periodical Cleaning of equalizing tank /grit chamber/ oil grease chamber/stilling chamber of sewage Water in the tank and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortor 1:3 where required all as required at site and directed by the Engineer-in-Charge at AF Stn Gurgaon for Sewage tank of STP 300 KLD of under mentioned sizes etc complete all as specified and directed :- \n(a) Equilizer tank/ /grit chamber/ oil grease chamber/stilling chamber of Sewage Water of size - 6.30m x 4.70m x 6m - 01 No. (b) Sludge holding tank of size - 2.6mx2.6mx3m-01 No. (c ) Fab-1 & Fab-2 of size - 2.1m x 2.1m x 5.80m - 02 Nos. (d) Tube Settler Tank - 4.1m x 2.5m x 3.8m - 01 No. (e) Treated water Tank 9.3 m x 3.4 m x 4.1m-01 No. \nNote: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the Delhi Canttonment Board/MCD. (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including ecessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineerin-Charge. 1 Each Job
23 23 Supply and mixing of Sodium hypochloride having 10% chlorine content etc required at site and all as directed by the Engineerin-Charge. 2500 Ltr
24 24 Supply and mixing of Poly aluminium chloride 100% purity etc required at site and all as directed by the Engineerin-\nCharge. 1200 Kgs
25 25 Supply fixing, testing and commissioning in-replacement of 0-6 LPH electrically operated, metered, adjustable dosing pump with accssories including lead tubing , connecting nuts injection check valve with 60 ltr PE/ FRP tank fitted with agiatator all as directed by engineer -in - charge E tank with PE/FRP/HDPE lid and level gauges, mounted on tank all as specified and directed by Engineer -in-charge . 2 Each
26 26 M & L for carrying sample testing of sewage water as per relevant IS of STP and submission of detailed test report to the office of the Engr-in-charge and testing in Govt approved laboratory as approved by GE. (a) Carrying out minimum essential testing of sewage water as per relevant IS mandatory for chemical, odour, PH value,TSS, BOD, COD, total nitrogen, sulphate, oil and grease, ammonical Nitrogen (NH3-N) and Bacteriological total colliform organism and other characterstics as per relevant IS of sewage water. (i) Cost of sterilized bottle as required. (ii) cost of sample collection from Site to laboratory including transportation charges are included in the quoted rate. 6 Each
27 27 M & L for Carrying sample for testing of treated water of STP and submission of detailed test report to the office of the Engineer-in-charge. Details are as under:- (a) carry ing out minimum essential testing of water as per IS 3025 & IS 1622 mandatory for chemical , colour, odour, PH value, TSS, BOD,COD, Total residual chlorine, total Nitrogen, sulphate, oil and grease, Ammonical nitrogen(NH3-N) and Bacteriological total coliform organism per 100ml (MPN) and Ecoli in 100ml. (b) Treated sewage water shall confirm to the following characterstics:- (i) TSS : < 10 mg/litre. (ii) BOD : < 10 mg/ litre. (iii) COD: < 150 mg/litre. (iv) Ph: 6.5 -8.5. (v) Total coliform: < 100 MPN/100 ml (desired nil). (vi) Resudual CI> 1 mg/litre. Rest of the characterstic of the treated water shall be as per IS 3025 & IS 1622. (i) Cost of sterilized bottle as required. (ii) cost of sample collection from Site to laboratory including transportation charges are included in the quoted rate. 6 Each
28 28 Supply only compressure oil all as specified and directed by Engineer - in- charge . 20 Ltr
29 29 Supply, laying , jointing, welding & testing MS pipe ( Heavy duty Class 'c') including fitting as required of following sizes laid in treches or laying or floor for connecting to various STP accessories and to connect outgoing water main from Non clogging submersible pump including taking down the unserviceable pipe all as directed by Engr-in-charge. Note:- MS flange and flange joint, bends etc complete with jointing material shall deemed to be included in the unit rate of this item.
30 29.01 100 mm bore 30 RM
31 29.02 80 mm bore 40 RM
32 29.03 65 mm bore 20 RM
33 29.04 50 mm bore 30 RM
34 29.05 40 mm bore 30 RM
35 30 S & F in repair GI tubing and connections including all fittings such as bends, belows tee, unions, sockets, flange welding on both side of a length of 6 mtr span etc or laid complete in trenches of size 50mm dia including taking down etc complete all as specififed and directed. 60 RM
36 31 M & L for High density polyethylene pipes (HDPE) of size 50mm of pressure rating 6 Kgf/cm2 fixed complete laid in trenches etc complete all as specified and directed. 100 RM
37 32 M & L for High density polyethylene pipes (HDPE) of size 90mm of pressure rating 6 Kgf/cm2 fixed complete laid in trenches etc complete all as specified and directed. 100 RM
38 33 M & L for Earthing complete with GI earth plate electrode 600 mm x 600 mm x 600 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised strip 25×4mm mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth pit surrounded by picked layer of coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 50mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 6mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified. 5 Each
39 34 Supply and fix cast iron flanged drilled heavy duty sluice valve 100 mm dia with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion, nuts and bolts with washers etc complete all as directed by Engr-in-Charge. \nNote. Rate for Nuts, bolts, gasket, etc. shall be included in the unit rates. 2 Each
40 35 Supply and fix in butterfly valves suiatable for GI/MS pipe complete including dismantling the old one all as specified and as directed by Engr-in-Charge for the following sizes :-
41 35.01 100 mm bore 2 Each
42 35.02 80 mm bore 4 Each
43 35.03 65 mm bore 4 Each
44 35.04 50 mm bore 6 Each
45 36 Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 50mm dia bore complete all as specified and directed by Engr-in-Charge. 2 Each
46 37 Supply and fix in replacement MCCB 100 A ,3 pole ,25 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the engineer-in-Charge. Make : L&T/Schneider/Siemens 2 Each
47 38 Supply and fixing in replacement of MCCB 250 A, 4 pole, 36 KA with adjustable thermal magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the engineer-in-Charge. Make :- Legrand/Schineder /Siemens/L&T 1 Each
48 39 Supply and fix in replacement MCCB 160 A ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the engineer-in-Charge. Make : L&T/Schneider/Siemens 1 Each
49 40 Supply and fixing in replacement of flat submersible 3 core 6 sqmm cable PVC insualted unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed. 300 RM
50 41 Supply and fixing in replacement of flat submersible 3 core 10 sqmm cable PVC insualted unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed. 140 RM
51 42 Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. 226 Cum
52 43 Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed. 150 Cum
53 44 Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed. 76 Cum
54 45 Supply and fix in replacement of cast iron pipes with spigot and socket ends centrifugally cast 100mm dia size Class LA, in any length, laid in trenches all as specified and as directed. 60 RM
55 46 Supply and fix in replacement of cast iron pipes with spigot and socket ends centrifugally cast 150mm dia size Class LA, in any length, laid in trenches all as specified and as directed. 60 RM
56 47 M&L for CI fitting for spigot and socketed pipes such as bends (any type, radius and angle) Tapers any type (straight, bend, increasing or double socket etc) Tee pieces single branch 'Y' juction double branch cross (all sockets or socket and spigot) collars, caps and plugs of any size complete all as specified and as directed. 250 Kg
57 48 Demolition of existing valve pit and M&L for construction of valve pit of size 900mm x 900mm x 900mm, consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc complete all as specified and directed. 3 Each Job
58 49 Disconnecting/removing the old unserviceable burnt parts from the FASD starters and supply and fix the new items as per exiting the model for AC 415 V,50 HZ 3 phase suitlable for lthe motors all as directed by the Engineer-in-charge.
59 49.01 Power Contactor, 3 pole, MNX-12 with front mounting Aux contacts block1 NO + 1NC of range AC1 -30 A & AC3 - 12 A of Make - L&T Cat No. CS94108 and Aux contat block Cat No CS94112^ 5 Each
60 49.02 Power Contactor, 3 pole, MNX-18 with front mounting Aux contacts Block1 NO + 21NC of range AC1 - 30 A & AC3 - 18 A of Make - L&T Cat No. CS94100 and Aux contact block Cat No CS94112^ 5 Each
61 49.03 Power Contactor, 3 pole, MNX-22 with front mounting Aux contacts 1 NO + 21NC of range AC1 - 32 A & AC3 - 22 A of Make - L&T Cat No. CS94980 and Aux contact block Cat No CS94113^ 5 Each
62 49.04 Power Contactor, 3 pole, MNX-25 with frot mounting Aux contacts 1 NO + 21NC of range AC1 - 45 A & AC3 - 25 A of Make - L&T Cat No. CS94110 and Aux contact block Cat No CS94114^ 4 Each
63 49.05 Power Contactor, 3 pole, MNX-32 with Aux contacts 1 NO + 1NC of range AC1 - 55 A & AC3 - 32 A of Make - L&T Cat No. CS94110 4 Each
64 49.06 Power Contactor, 3 pole, MNX-40 with Aux contacts 1 NO + 1 NC of range AC1 - 55 A & AC3 - 40 A of Make - L&T Cat No. CS94190 and Aux contact block Cat No CS94114^ 5 Each
65 49.07 Power Contactor, 3 pole, MNX-45 with Aux contacts 2 NO + 2 NC of range AC1 - 80 A & AC3 - 45 A of Make - L&T Cat No. CS97074 4 Each
66 49.08 Power Contactor, 3 pole, MNX-50 with Aux contacts 2 NO + 2 NC of range AC1 - 85 A & AC3 - 50 A of Make - L&T Cat No. CS97076 4 Each
67 49.09 Power Contactor, 3 pole, MNX-70 with Aux contacts 2 NO + 2 NC of range AC1 - 100 A & AC3 - 70 A of Make - L&T Cat No. CS97076 3 Each
68 49.1 Power Contactor, 3 pole, MNX-80 with Aux contacts 2 NO + 2 NC of range AC1 - 100 A & AC3 - 80 A of Make - L&T Cat No. CS97077 2 Each
69 49.11 Power Contactor, 3 pole, ML-2 with Aux contacts 2 NO + 2 NC of range AC1 - 40 A & AC3 - 32 A of Make - L&T Cat No. SS90701 3 Each
70 49.12 Bimetal over load relay MN-2 type directly mounted/operated of range 9-15 Amp of Make L&T Cat No. SS94142OOVO 3 Each
71 49.13 Bimetal over load relay MN-2 type directly mounted/operated of range 14-23 Amp of Make L&T Cat No. SS94144OODO 3 Each
72 49.14 Bimetal over load relay MN-5 type directly mounted/operated of range 30-50 Amp of Make L&T Cat No. SS94136OOGO 3 Each
73 49.15 Bimetal over load relay MN-5 type directly mounted/operated of range 66-110 Amp of Make L&T Cat No. SS94137OOKO 3 Each
74 49.16 single phase preventer suitable for 3 HP to 60 HP pump sets 4 Each
75 50 Supply, laying and testing cable XLPE insulated, screened, PVC badded,galvanised steel strip or wire armoured, Heavy duty, electric power cable with Aluminum conductor 1100 Volts Grade, Cross-Sectional area as mentioned under 120 Sqmm 3.5 core complete all as specified and directed.\n
76 50.01 35 Sqmm, 3.5 core 450 RM
77 50.02 50 Sqmm, 3.5 core 100 RM
78 50.03 70 Sqmm, 3.5 core 100 RM
79 51 M&L, for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. 43 CUM
80 52 Supply and laying, sub class old 'B' burnt bricks, size of brick 230x115x75mm, laid as cable protection cover complete all as specified and directed. 4150 EACH
81 53 M & L for Carrying sample for testing of water of well/GMDA and submission of detailed test report to the office of the Engineer-in-charge. Details are as under :- (a) carrying out minimum essential testing of water as per IS 30271 & IS 30271(1) mandatory for chemical, colour, odour, PH value, Turbidity,Chlorode, Total Alkalimity, Total Dissolved Solids, Hardness, Iron and Bacteriological Taste, Calcium, Magnesium per 100ml. (b) Drinking water shall confirm to the following characterstics limit as per protocol IS : 10500 : 2012:- (i) Colour : 5 /15 Hazen Max. (ii) Odour :Agreeable. (iii) Ph value : 6.5 - 8.5. (iv) Turbidity : 1/5 NTU max (v) Chloride : 250 gm/ltr max. (vi) Total Alkalimity : 200 gm/ltr max (vii) Total Dissolved Solids : 500 gm/ltr max. (viii) Hardness : 200 gm/ltr max. (ix) Irons : 0.3 gm/ltr max. (x) Test : Agreeable. (xi) Calcium : 75 gm/ltr max. (xii) Magnesium : 30 gm/ltr max Rest of the characterstic of the drinking water shall be as per IS 30271 & IS 30271(1). (i) Cost of sterilized bottle as required. (ii) cost of sample collection from Site to laboratory including transportation charges are included in the quoted rate. 24 Each
82 54 Supply, installation , commissioning and testing of factory made LT panel board of suitable size double door, indoor type, floor mounted, dust, weather and vermin proof, 415 volts, 3 phase, wire, 50 Hz AC supply powder coated internally and externally made out of 2 mm thick outside body and inside body 1.6mm thick steel sheet with locking arrangement, front side and rear side opening arrangement including mounted on Angle iron stand of size 50x50x6mm having minimum height from ground level 450mm , duly grouted or welded on floor. Aluminium bus bar TPN of 400 A for all feeders to accommodate and including following items :- 1 Each
83 54.01 (a) Incoming MCCB 200 Amp 35KA, with adjustable thermal and magnetic release, 4 pole -01 No.\n(b) Outgoing MCCB 100 Amp 35 KA,with adjustable thermal and magnetic release 3 pole -03 Nos.\n(c ) FASD starter suitable for motor of capacity of 40 HP , 3 phase, AC, 415 Volt, complete - 03 No.\n(d) LED RYB indication for each incoming & outgoing supplies- 03 Sets\n(e) Digital Voltmeter, 0-500 Volt meter with selector switch-01 Set\n(f) Digital Ampere meter, 0-300 Amp with suitable size of CT selector switch- 1Set \n(g) Termination of all cables with suitable size thimble and gland- 1 Job\nNote: The rate of all above items shall deemed to be included in the quoted rates. \nMake Siemens/L&T/ABB/Schneider/Legrand/Hensel/Bhandari/Indo Asian/SMS panels & switchgear/Shalabh/Havells/Hartek/ Universal Switch Gear Control, DV Electromatic Pvt Ltd/Power System & Controls Jallandhar/Neptune /GM&G/ITE Gurgaon\n
84 55 Supply, installation , commissioning and testing of factory made LT panel board of suitable size double door, indoor type, floor mounted, dust, weather and vermin proof, 415 volts, 3 phase, wire, 50 Hz AC supply, powder coated internally and externally made out of 2 mm thick outside body and inside body 1.6mm thick steel sheet with locking arrangement, front side and rear side opening arrangement including mounted on Angle iron stand of size 50x50x6mm having minimum height from ground level 450mm , duly grouted or welded on floor. Aluminium bus bar TPN of 300 A for all feeders to accommodate and including following items :- 5 Each
85 55.01 (a) Incoming MCCB 160 Amp 35KA, with adjustable thermal and magnetic release, 4 pole -01 No.\n(b) Outgoing MCCB 63 Amp 35 KA,with adjustable thermal and magnetic release 3 pole -02 Nos.\n(c ) FASD starter suitable for motor of capacity of 20 HP , 3 phase, AC, 415 Volt, complete - 02 No.\n(d) LED RYB indication for each incoming & outgoing supplies- 03 Sets\n(e) Digital Voltmeter, 0-500 Volt meter with selector switch-01 Set\n(f) Digital Ampere meter, 0-300 Amp with suitable size of CT selector switch- 1Set \n(g) Termination of all cables with suitable size thimble and gland- 1 Job\nNote: The rate of all above items shall deemed to be included in the quoted rates. \nMake Siemens/L&T/ABB/Schneider/Legrand/Hensel/Bhandari/Indo Asian/SMS panels & switchgear/Shalabh/Havells/Hartek/ Universal Switch Gear Control, DV Electromatic Pvt Ltd/Power System & Controls Jallandhar/Neptune /GM&G/ITE Gurgaon\n
86 56 Supply, installation , commissioning and testing of factory made LT panel board of suitable size double door, outdoor type, floor mounted, dust, weather and vermin proof, 415 volts, 3 phase, wire, 50 Hz AC supply, powder coated internally and externally made out of 3.15 mm thick outside body and inside body 1.6mm thick steel sheet with locking arrangement, front side and rear side opening arrangement including mounted on Angle iron stand of size 50x50x6mm having minimum height from ground level 450mm , duly grouted or welded on floor. Aluminium bus bar TPN of 300 A for all feeders to accommodate and including following items :- 3 Each
87 56.01 (a) Incoming MCCB 160 Amp 35KA, with adjustable thermal and magnetic release, 4 pole -01 No.\n(b) Outgoing MCCB 63 Amp 35 KA,with adjustable thermal and magnetic release 3 pole -02 Nos.\n(c ) FASD starter suitable for motor of capacity of 20 HP , 3 phase, AC, 415 Volt, complete - 02 No.\n(d) LED RYB indication for each incoming & outgoing supplies- 03 Sets\n(e) Digital Voltmeter, 0-500 Volt meter with selector switch-01 Set\n(f) Digital Ampere meter, 0-300 Amp with suitable size of CT selector switch- 1Set \n(g) Termination of all cables with suitable size thimble and gland- 1 Job\nNote: The rate of fll above items shall deemed to be included in the quoted rates.\n Make Siemens/L&T/ABB/Schneider/Legrand/Hensel/Bhandari/Indo Asian/SMS panels & switchgear/Shalabh/Havells/Hartek/ Universal Switch Gear Control, DV Electromatic Pvt Ltd/Power System & Controls Jallandhar/Neptune /GM&G/ITE Gurgaon\n
88 57 M & L for trenchless boring under roads/ crossing or fixed to wall/ pole, GI tubing light grade of size upto 150mm bore for protection of UG cables complete all as specified and as directed. 25 RM
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail