Part-A Reo Raod To Tube Well Sadak Tak Part-B Construction Of H Part-A Reo Raod To Tube Well Sadak Tak Part-B Construntion Of H, VIRPUR-Bihar

Rural Works Department has published Part-A Reo Raod To Tube Well Sadak Tak Part-B Construction Of H Part-A Reo Raod To Tube Well Sadak Tak Part-B Construntion Of H. Submission Date for this Tender is 24-06-2021. Tube Well Tenders in VIRPUR Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

28224692
Corrigendum : Part-A Reo Raod To Tube Well Sadak Tak Part-B Construction Of H Part-A Reo Raod To Tube Well Sadak Tak Part-B Construntion Of H
Open Tender
Indian
Bihar
VIRPUR
24-06-2021

Tender Details

Part-A Reo Raod To Tube Well Sadak Tak Part-B Construction Of H Part-A Reo Raod To Tube Well Sadak Tak Part-B Construntion Of H

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Jun-2021 Sudhi Other 24-06-2021

Key Value

Document Fees
INR 10000 /-
EMD
INR 1926935.0 /-
Tender Value
INR 9.63 Crore /-

BOQ Items

Name of Work: Part-A REO Raod To Tube Well Sadak Tak Part-B CONSTRUNTION OF HL BRIDGE 4X16.5m span With Approach Road=100 m AT
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Part-A\nREO Raod To Tube Well Sadak Tak
2 2 Providing & Fixing of Working benchmark/Refrence Pillars 01 nos. per km & 04 Nos. of reference pillars required for 1 Km. as per drawings given and direction of E/I
3 3 Benchmark Pillars 01 nos. per km 5 No
4 4 Refrence Pillars 04 nos. per km 19 No
5 5 Clearing and Grubbing Road Land\nClearing and Grubbing Road Land ( By manual means) including uprooting wild vegetation , grass ,bushes ,shrubs , saplings and trees of girth upto 300mm , removals of stumps of such trees cut earlier & disposal of unserviceable materials & stacking of serviceable materials to be used or auctioned upto a lead of 1000 m including removal and disposal of top organic soil not exeeding 150mm in thickness as per technical specification - clause 201.1 and direction of E/I ( By Manual Means) In area of non-thorny jungle 3.37 Hect.
6 6 Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 100 m as per Technical Specification Clause 301.5 3606.76 Cum
7 7 Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 1024.95 Cum
8 8 Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m & 100 m as per Technical Specification Clause 303.1. (Including Royality & Labour Cess). 12713.6 Cum
9 9 Granular Sub-base with Well Graded Material (Table 400.1) :- Construction of granular sub-base by providing well graded material, spreading in uniform layers with tractor mounted grader arrangement on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (For Grading I Material) 3758.78 Cum
10 10 WBM Grading 3 :-Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. 1382.17 Cum
11 11 Prime Coat (Low Porosity) :- Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0kg/sqm using mechanical means as per Technical Specification Clause 502 16516.3 Sqm
12 12 Tack Coat:- Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25-0.30kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. 16516.3 Sqm
13 13 Mix Seal Surfacing Type B Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 16516.3 Sqm
14 14 Cement Concrete Pavement M30\nConstruction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501. 306 Cum
15 15 Hard Shouldering :- Laying brick soling layer on prepared sub-grade with brick on end edging according to lines, graded and cross-section shown on the drawing filling joints with sand and earth, spreading 25 mm thick layer of earth over brick soling, watering and rolliing the same with three wheel road roller 80-100 kN as per Technical Specification Clause 412 500 sqm
16 16 Kilometre Stone
17 17 Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
18 18 Ordinary Kilometer Stone (Precast) 6 Each
19 19 200 m stone (precast) 19 Each
20 20 (I)Providing and Fixing 'Logo' of MMGSY Project :-Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 6 Each
21 21 Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 264 Per Cm Height Per Letter
22 22 Boundry Pillar/ Guard Post Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704 72 No
23 23 Retro-reflectorised Traffic Signs :- Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
24 24 600 mm equilateral & triangle 12 Each
25 25 800 mm x 600 mm rectangular 6 Each
26 26 600 mm x 450 mm rectangular 8 Each
27 27 900 mm side octagon, OR 4 Each
28 28 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface :- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. 863.6 Sqm
29 29 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Conctete Surface :- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. 100 Sqm
30 30 Planting of tree by the road side (Avenue Tree) in 0.6 m dia holes, 1 m deep dug in the Ground, Mixing the soil with decayed farm yard/ slug manure, planting the saplings back filling the trench, watering, fixing the tree guard & maintain the Plant for One Year. 431.8 No.
31 31 Cross Drainage
32 32 H.P 1 x 1000 MM
33 33 Earth work in excavation for foundation of structures upto 3.0 m depth as per drawing and technical specification clause 1104 89.4 Cum
34 34 Providing M15 (PCC 1:2.5:5) as levelling course in foundation :-- Providing PCC M 15 (1:2.5:5) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 13.8 Cum
35 35 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 ( M20 ) 101.22 Cum
36 36 Providing and laying RCC pipe NP-3 for culverts on first class bedding of PCC M10 material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works,backfilling concrete and masonary works in head walls and parapets as per clause 1106 22.5 MT
37 37 Painting on Parapet Wall (Black & White Strips) Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 61.92 Sqm
38 38 RCC BOX CULVERT (2.0 X 2.0 )
39 39 Earth work in excavation for foundation of structures upto 3.0 m depth as per drawing and technical specification clause 1104 345.36 Cum
40 40 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 PCC M-15 Grade 24.9 Cum
41 41 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 PCC M-20 Grade 100.2 Cum
42 42 Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 0.47 MT
43 43 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 PCC M-20 Grade 48.75 Cum
44 44 Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 108 Nos
45 45 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 RCC M-25 Grade 37.59 Cum
46 46 Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 3.69 MT
47 47 Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (With Sandy Materials ) 98.94 Cum
48 48 Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 68.64 Cum
49 49 Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 RCC M-30 Grade 13.05 Cum
50 50 Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 1.11 MT
51 51 Parapet Construction Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 ( M20 ) 3.6 Cum
52 52 Painting on Parapet Wall Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 26.88 Sqm
53 53 Drainage spouts complete as per drawing and technical specifications Clause 1209 12 Nos
54 54 300MM Irrigation Pipe
55 55 Providing and laying of a reinforced cement concrete pipe duct,300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills,constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:981997,bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe\nsubject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings.\n 105 RM
56 56 Estimate For Dismantling
57 57 Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.
58 58 Cement Concrete 16.56 Cum
59 59 Reinforced Cement Concrete 33.39 Cum
60 60 Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
61 61 Cement mortar 67.82 Cum
62 62 Removing all types of Hume pipes and stacking including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202.
63 63 Above 600 mm to 900 mm dia Hume pipe 5 RM
64 64 GST @ 12% :- 1 RS
65 65 L.C @ 1% :- 1 RS
66 66 Seigniorage Fee @ 10% :- 1 RS
67 67 1st Year Maintenance Cost 1 Year
68 68 2nd Year Maintenance Cost 1 Year
69 69 3rd Year Maintenance Cost 1 Year
70 70 4th Year Maintenance Cost 1 Year
71 71 5th Year Maintenance Cost 1 Year
72 72 GST @ 12% :- 1 RS
73 73 L.C @ 1% :- 1 RS
74 74 Seigniorage Fee @ 10% :- 1 RS
75 75 Part-B \nCONSTRUNTION OF HL BRIDGE 4X16.5m span With Approach Road=100 m AT CH-1+450
76 76 FOUNDATION
77 77 Excavation for Structures
78 78 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
79 79 I. Ordinary Soil
80 80 i) Upto 3m depth 701.41 Cum
81 81 Providing and laying of PCC M15 levelling course 100mm thick below the pile cap.
82 82 II. PCC Grade M-15 (Levelling Course for Pile Cap) 35 Cum
83 83 R.C.C. grade M 30 in Pile Foundation complete as per Dwg & Tech Specification.
84 84 Pile Cap in RCC M-30 385.55 Cum
85 85 Bored cast-in-situ M35 grade R.C.C. Pile excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m.
86 86 II. 1200 mm Dia 648 m
87 87 Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 98.26 MT
88 88 Providing and Constructing Temporary Earth Island (Assuming depth of water 1.0 m and height of island to be 1.25 m including Royality for earth @ Rs. 5526.00 for each Island.) 3 No.
89 89 Providing and constructing one span service road to reach island location from one pier location to another pier location including Royality for earth @ Rs. 225.00 per m for service Road. 49.5 Rm
90 90 SUBSTRUCTURE
91 91 R.C.C. grade M-30 in Substructure complete as per Dwg & Tech Specification
92 92 RCC M-30
93 93 i) Upto 5m height (Using Concrete Mixer) 231.7 Cum
94 94 ii) From 5m upto 10m height (Using Concrete Mixer) 5.18 Cum
95 95 R.C.C. grade M-35 in Substructure complete as per Dwg & Tech Specification
96 96 RCC M-35
97 97 ii) From 5m upto 10m height (Using Concrete Mixer) 17.07 Cum
98 98 Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 35.45 MT
99 99 Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete asper drawing and approved technical specifications. 24 Nos
100 100 Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications. 262950 cc
101 101 Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 120 Nos
102 102 Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
103 103 I) Sandy Material 164.78 Cum
104 104 Providing and laying filter media with granular crushed aggregates (Jhama Metal) as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 82.34 Cum
105 105 SUPERSTRUCTURE
106 106 Providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
107 107 II. RCC M-30 282.54 Cum
108 108 Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in superstructrue complete as per drawings and technical specification Clauses 1002, 1010 & 1202 41.49 MT
109 109 Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 45.02 Cum
110 110 Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 160.08 m
111 111 Drainage Spouts complete as per drawing and technical specifications Clause 1209 32 No
112 112 P.C.C. M-15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specificatios Clauses 800 & 1211. 8.87 cum
113 113 Reinforced Cement Concrete M-30 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 20.53 cum
114 114 Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.) 42.25 m
115 115 Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 42.25 m
116 116 Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications. 42.25 m
117 117 PROTECTION WORK
118 118 Excavation for Structures
119 119 Providing and laying boulder pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 225.78 cum
120 120 Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302 106.17 cum
121 121 E. APPROCH ROAD
122 122 Clearing and Grubbing Road Land ( By manual means) including uprooting wild vegetation , grass ,bushes ,shrubs , saplings and trees of girth upto 300mm , removals of stumps of such trees cut earlier & disposal of unserviceable materials & stacking of serviceable materials to be used or auctioned upto a lead of 1000 m including removal and disposal of top organic soil not exeeding 150mm in thickness as per technical specification - clause 201.1 and direction of E/I 0.1 Ha
123 123 Construction of Embankment with material obtained from borrow pits with a lift upto 1.5 m , transporting to the site spreading , grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 . 2105 Cum
124 124 Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. 79.13 Cum
125 125 Construction of granular sub-base by providing well graded material, spreading in uniform layers with tractor mounted grader arrangement on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. 82.62 Cum
126 126 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. 28.69 Cum
127 127 Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. 382.5 Sqm
128 128 Providing and applying tack coat with bitumen emulsion (RS ) using emulsion distributor @ 0.2 to 0.25 kg per sq m on the prepared bituminous surface cleaned with hydraulic broom as per technical specification clause 503. 382.5 Sqm
129 129 Providing , laying and rolling of open graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm agreegates either using penetration grade bitumin or emulsion to reqired line grade , and level to serve as wearing course on a previously prepared base , including mixing in a suitable plant , laying and rolling with a three wheel 80-100 KN static roller capacity , ifnished to required level and grades to be followed by seal coat of either Type A or Type B or Type as per Technical Specification clause 508 382.5 Sqm
130 130 Providing and Fixing 'Logo' of Project informayory sign board with Logo as per MORD specifications and drawing. Three MS plates of 1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5 m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 Nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600 mm,600 mm,600 below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12SWG steel plate tube. All M.S will be stove enameled on both sides. Lettering and printing arrows, border etc, will be painted with ready mixed synthetic enamer paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 abd Annexure 1700.1. 3 NO
131 131 Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. 20 Sqm
132 132 Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704 135 No
133 133 12% GST 1 RS
134 134 1% LABOUR CESS 1 RS
135 135 SEIGNOIRAGE FEE 10% 1 RS
136 136 Total Cost for 1st Year Maintenance Work 1 Year
137 137 Total Cost for 2nd Year Maintenance Works 1 Year
138 138 Total Cost for 3rd Year Maintenance Works 1 Year
139 139 Total Cost for 4th Year Maintenance Works 1 Year
140 140 Total Cost for 5th Year Maintenance Works 1 Year
141 141 12% GST 1 RS
142 142 1% LABOUR CESS 1 RS
143 143 SEIGNOIRAGE FEE 10% 1 RS
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy