Providing , Fixing And Repairing Of Electrical Components Of Panchana Dam Karauli Year 2021-22, Panchana Dam karauli-Rajasthan

Water Resources Department-WRD has published Providing , Fixing And Repairing Of Electrical Components Of Panchana Dam Karauli Year 2021-22. Submission Date for this Tender is 24-06-2021. Cutting Crimping and Punching Tools Tenders in Panchana Dam karauli Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

28223799
Providing , Fixing And Repairing Of Electrical Components Of Panchana Dam Karauli Year 2021-22
Open Tender
Indian
Rajasthan
Panchana Dam karauli
24-06-2021

Tender Details

Providing , Fixing And Repairing Of Electrical Components Of Panchana Dam Karauli Year 2021-22-1 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be nsubmitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work 2 Armoured Cable.E110138A 70.0 Sq. mm 3.5 core 3 Unarmoured Cable E110113C 10.0 Sq. mm 4 core 4 Providing & Fixing of ISO certified company made UL listed , IP 65110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as nrequired. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work Red/yellow/Green colour 5 Supplying and making end termination with heavy aluminium lugs Pin / ring type (as per IS 8309 -1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc of following size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work 6 2.5 Sq.mm 7 10.0 Sq.mm 8 50.0 Sq.mm 9 70.0 Sq.mm 10 Providing & Fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , Luminous type Red , Yellow, Green, Amber 11 Providing & Fixing of IP 51 ( upto 500) V range Volt meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Meter shall give true RMS measurments, acc. CI 1.0 or better , with field programmable primary & sec. values PT(VT) primary upto 2000 KV. Field-programmable high and low threshold values, meter shall compliance of IS 13875 & IEC 61236. as required. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &All as per pre approved by Engineer in charge. For additional technical parameters of products/ work Digital type 12 Providing & Fixing of IP 51 CT operated direct reading type flush mounting Ampere meter of Moving Iron type of class 1.5 accuracy on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work Above 500A 13 Supplying and making one end termination with heavyduty single compression brass gland (as per IS 12943-1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS8337- 1976) duly crimped with crimping tool, PVC tape asper PWD specification for electrical Works etc forfollowing size ofArmoured PVC insulated &PVCsheathed/XLPEaluminium/copperconductorcableof1100voltgradeas required of size. All as per preapproved by Engineer in charge. For additional technicalparameters of products/ work 14 3 x 10.0 sq.mm 15 3.5 x 70.0 sq.mm 16 Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , 14 to 23 Amp 17 Laying and fixing of PVC /XLPE power Cable of 1.1 KV grade of following size on wall/ cable tray with saddles/MS flat clamp etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , 18 upto 35 sqmm 19 above 35 Sqmm and upto 95 sqmm 20 SITC of IP 40 3 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , With Thermal Magnetic release 200 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 21 Contactor block ML-2,32 ampere, AC-3, 415 volts, 50 HZ, ISI- 3947, EC60947-4-1 for gallery 22 Providing and installig magnet brake coil for radial gates 440 volts 40 Amp 23 Providing and installing limit switch 220 volts siemens or equivalent make 24 Providing and installing main switch 100 ampere 440 volts

Key Value

Document Fees
INR 500 /-
EMD
Refer document
Tender Value
Refer document
Disclaimer :