Housing Urban and Rular Development Government Departments Closing in 0 days TDR #28211064

Construction Of Road From Madhukumar To Tablajoy Including 2 Lsb Pmgsy Road Works

Issued by Government Departments · Chawmanu, Tripura
Tender Value
5.44 Crore
Estimated cost
Bid Submission
06 Jul 2021
0 days left
EMD
10.90 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chawmanu → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Road From Madhukumar To Tablajoy Including 2 Lsb Pmgsy Road Works

BOQ

Name of Work: Construction of road from Madhukumar to Tasblajoy (Package No:- TR-04-213 ) (Length :-2.919 km) (Link Route No:- L022 under Chawmanu Block)including 2(two) Long span Bridges (13th call)
Sl. No. Item Description
11.Madhukumar to Tasblajoy (Package No:- TR-04-213 )
2Bill No. I : Site Clearance & Setting out
3Clearing and grubbing Road land
4Clearing and grubbing Road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300m.m removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned, upto a lead of 1000m including removal and disposal of top organic soil not exceeding 150mm in thickness as per technical specification clause 201.
5(A) By manual means
6(i) In area of non thorny Jungle
7Setting Out (As per drawing enclosed) with Reference Pillars on both sides of the formation width Burjes @50m interval using PCC with jhama brick aggregate for all class of soil including marking of centre line, setting out curves and recording of levels etc.
8Bill No. II : Earth work Erosion control & Drainage
9Compacting Original ground
10(i)Compacting original ground supporting embankment
11Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1
12(ii) Compacting original ground supporting sub grade
13Loosening of the ground upto a level of 300mm below the sub grade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for sub grade construction as per technical specification clause 303.5.2
14For all classes of soil
15Construction of Embankment with approved materials deposited at site from Roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of tables 300.1 and 300.2 as per technical specification clause 301.5
16(A) For spreading beyond 100m.
17(B) For spreading within 100m.
18Excavation in cutting in soil by manual means with lead upto 50.0m.
19Excavation in road way cutting in soil by using manual means for carrying of cut earth to Embankment site with a lift upto 1.5m and lead upto 50.0m as per technical specification clause 302.3
20Excavation in Soil with Dozer with lead upto 100 m.
21Excavation for roadway in soil by mechanical means with Dozer including cutting and pushing the earth to site of embankment upto a distance of 100 m. including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3
22Excavation in soil using hydraulic Excavator and Tippers with disposal upto 1000m
23Excavation for road work in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections and transporting to the embankment location with a lift upto 1.5m and lead upto 1000m as per technical specification clause 302.3
24Construction of sub grade and earthen shoulder
25Construction of sub grade and earthen shoulder with approved materials obtained from borrow pits/cuts with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table 300.2 with lead 1000 m as per Technical specification Clause 303.1
26Protection Works
27Surface Drains
28Construction of unlined surface drains of average cross-sectional area 0.4 sqm. in ordinary soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3 m and lead of 50 m (average lead 25 m ) as per Technical Specification Clause 307I) Surface Drains in Ordinary Soil(A) Manual Means
29(i) Earth work in excavation for Toe wall as per drawing and technical specifications clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50m. Dressing of sides and bottom and back filling in trenches with excavated suitable material.
30(ii)Brick masonry work in cement mortar (in substructure) complete excepting pointing & plastering, as per drawing & technical specification clauses 602, 603, 604, 1202 and 1204.
31(iii) Plastering with cement mortar (1:4) 15mm thick on brickwork (in substructure) as per Technical specification clauses 613.4 & 1204.
32(iv)Providing weepholes in brick masonry toe wall with 100 mm dia AC pipe or PVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7
33(v)Providing concrete for plain concrete M-15 (using jhama brick aggregate) in open foundations complete as per drawings & technical specifications clauses 802, 803, 1202 and 1203.
34(i) In foundation below GL
35(ii) In Copings
36BILL NO. III : Sub-base & Base Courses
37Granular Sub-base
38(A) By Mix in Place Method
39Construction of granular sub-base by providing well graded material ( Jhama Brick Aggregate , as per Table 400.1 ), spreading in uniform layers with tractor with attachments on prepared surface, mixing by mix in place method with rotavator at OMC, applying and brooming sand to fill up the interstices of coarse aggregate, watering and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
40(ii) For Grading - II Material ( Jhama brick aggregate )
41WBM Grading - 3- 75mm compacted thickness
42Providing, laying spreading and compacting 53m.m to 12.5m.m jhama Brick aggregates to water Bound Macadam specification including spreading in uniform thickness, hand packing rolling with three wheel vibratory roller 80 - 100 K.N static weight in stages to proper grade and camber, applying and brooming, filler materials to fill up the interstices of course aggregate, watering and compacting fill up the interstices as per technical specification clause 405.
43BILL NO. IV : Surface courses (Bituminous)
44Prime coat.
45Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate 0.7 - 0.1 kg/sqm using mechanical means as per Technical Specification Clause 502
46(i) Low Porosity
47Providing and applying tack coat with Bitumen Emulsion (RS - 1) using emulsion distributor at the rate of 0.25 to 0.30 kg. Per sqm on the prepared dry and hungry bituminous surface cleaned with hydraulic broom as per technical specification Clause 503.
4820mm. Thick open - graded premix carpet using Bituminous (by cold mix technology ) Binder.
49Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2mm to 5.6mm aggregates using cold mix technology on to required line, grade and level to serve as wearing course on a previously prepared bases including mixing in a suitable plant, laying and rolling with a three wheel 80 - 100 KN Static roller capacity finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.
50By Mechanical Means with Bitumen (by cold mix technology)
51Providing and laying seal coat sealing the voids inbituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical SpecificationClause 510
52i) By Manual Means with Bitumen (S-65) Type D
53BILL NO. V : Road Logo other Road furniture
54Providing and fixing of retro-reflectiorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminum sheeting, 1.5 mm thick supported on a mild steel angle Iron post 75mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 Grade cement concrete 450mm x 450mm x 600mm, 600m.m below ground level as per drawing and technical specification clause 801.
55600mm equilateral triangle aluminum sheeting
56600mm Dia circular aluminum sheeting
57800 x 600 mm rectangular aluminum sheeting
58Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc. as per drawing and Technical Specification Clause 1703
59(II)Ordinary Kilometer Stone (precast)
60(III) 200 m stone (Precast)
61Construction of RCC guide posts of 250mm dia and total 600mm long, (300mm below G.L) M15 grade ( with jhama brick aggregate) case in situ with 20mm nominal size aggregate, true to line and grade, tolerance of vertical RCC Posts not to exceed 1 in 500 as per drawing and technical specification clause 1401.6.
62(a) In ordinary soil
63Boundary pillar (with PCC M15 grade using jhama Brick aggregate and reinforcement)
64Plain cement concrete M15 grade (Using jhama brick aggregate and reinforcement) boundary pillar / local stone of standard design as per IRC : 25 fixed in position including finishing and lattering but excluding painting as per drawing and technical specification clause 1704.
65Providing and Fixing \"Logo\" of PMGSY Project
66Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25 mm x 5 mm size on back on edges. The lower plate will be welded with MS angle iron frame of 25 mm x 25 mm x 5 mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75 mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450 mm x 450 mm x 600 mm , 600 mm below ground level. The top most diamond plate will be welded to middle plate by 47 mm x 47 mmof 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
67Providing and Fixing \"Citizens\" Information Board\" of PMGSY / Bharat Nirman Project
68Providing and fixing of typical Citizens\" Information board with Logo as per MORD specifications and drawing. Two MS Plates of 2.0 mm thick, duly welded with MS flat iron 50 mm x 5 mm size on back on edges. The flat iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 76.1 mm OD (horizontal) and 2 Nos. 76.1 mm OD (Vertical) steel tube posts { as per IS : 1161 - 1979, Medium Class } duly embedded in cement concrete M-15 grade blocks of 600 mm x 600 mm x 750 mm , 750 mm below ground level.All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube and flats will be painted with primer and two coats of epoxy paint as per drawing and specification Clause 1701 and Annexure 1700.1
69Providing and Fixing \"Maintenance Board\" of PMGSY / Bharat Nirman Project
70Providing and fixing of typical Maintenance board as per MORD specifications and drawing. Two MS Plates of 2.0 mm thick, duly welded with MS flat iron 50 mm x 5 mm size on back on edges. The flat iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 76.1 mm OD (horizontal) and 2 Nos. 76.1 mm OD (Vertical) steel tube posts { as per IS : 1161 - 1979, Medium Class } duly embedded in cement concrete M-15 grade blocks of 600 mm x 600 mm x 750 mm , 750 mm below ground level.All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube and flats will be painted with primer and two coats of epoxy paint as per drawing and specification Clause 1701 and Annexure 1700.1
71Cross Drainage Structure
72BILL NO.VI : CD Works
73Box cell Culvert
74Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.
75(A) Ordinary Soil(I) Upto 3 m depth
76Construction of Wing Walls, Return Wall etc.
77Providing M-15 concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & technical specifications Clauses 802, 803, 900, 1202 and 1203.
78Brick masonry work in 1:4 cement mortar in wing wall, Return wall etc. complete excepting pointing & plastering as per drawing & technical specification clause 602,603,604,1202 and 1204.
79Plastering with cement mortar (1:4) 15 mm thick on brickwork in wing wall, Return wall etc. in substructure as per technical specification clause 613.4 & 1204
80Plain / reinforced cement concrete in substructure complete as per drawing & technical specification Clause 802,804,805,806,807,1202 & 1204.
81(i) PCC grade M-15 below base slab
82(i) RCC grade M-15 in Pillars for inscribing Structure Number
83(i) RCC grade M-25
84Plain cement concrete grade M20 in substructure complete as per drawing & technical specification Clause 802,804,805,806,807,1202 & 1204.
85Supplying, fitting & placing HYSD bar
86Supporting fitting and placing HYSD bar reinforcement (Fe500) in substructure completed as per drawing and technical specification Clauses 1002, 1005, 1010 and 1202.
87(I) In RCC Box
88(II) In Pillar for inscribing Structure Number
89Providing and laying reinforced cement concrete (using fine sand) in superstructure as per drawing and technical specification clause 800,1205.4 & 1205.5
90(I) In RCC grade M25
91Supplying, fitting & placing HYSD bar
92Supporting fitting and placing HYSD bar reinforcementin superstructure completed as per drawing and technical specification Clauses 1002, 1005, 1010 and 1202.
93Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or PVC pipe ( 110 mm OD of 6.0 Kg/cm2pressure ) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7
94Drainage spout
95Providing and fixing in position Drainage spouts complete as per drawing & technical specifications Clause 1209
96Providing and laying of cement concrete block pitching
97Providing and laying of cement concrete blocks of size as per Table 1300 1 cast - in - situ and made with nominal mix of M-15 grade cement concrete (Using jhama Brick aggregate) as per drawing and technical specification clauses 1301 ((rate includes preparation of floor)
98Painting two coats on new concrete surface
99Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surface as per drawing and Technical Specification on Pillars for inscribing Structure Number
100Printing new letters and figures of any shade
101Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 in English or RomanHyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 160 mm height, i.e., 1.6 m
102RCC Bridge ( CH:1767 m)
103Excavation for structure
104Without dewatering.Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.Ordinary SoilUpto 3 m depth
105Filling in foundation
106Filling in foundation trenches as per drawing & technical specification Clause 305.3.9Earth filling (For marshy soil)
107Bored Cast-in-Situ piles 1200 mm dia , M-25 grade RCC pile excluding reinforcement complete as per drawing and technical specification and removal of excavated earth with all lifts and lead upto 1000 m.
108Reinforcement for Pile
109Supplying, fitting & placing HYSD bar reinforcement in foundation complete as per drawings & technical specifications Clauses 1000 & 1202
110Providing concrete for plain / reinforced concrete in open foundation complete as per drawing & technical specification clause 802,803,1202 and 1203Nomonal mix (1:2.5:5)(Hand mix)
111RCC M-25 in Pile cap
112Providing concrete for plain / reinforced concrete in open foundation complete as per drawing & technical specification clause 802,803,1202 and 1203RCC grade M-25
113Reinforcement for Pile cap
114Supplying, fitting & placing HYSD bar reinforcement in foundation complete as per drawings & technical specifications Clauses 1000 & 1202
115RCC M-25 in Abutment /Pier
116Plain / reinforced cement concrete in substructure complete as per drawing & technical specification Clause 802,804,805,806,807,1202 & 1204.RCC Grade M-25For height above 5 m upto 10 m
117Reinforcement for Abutment /Pier
118Supplying, fitting & placing HYSD bar reinforcement in substructure complete as per drawings & technical specifications Clauses 1002,1005,1010 & 1202
119Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or PVC pipe ( 110 mm OD of 6.0 Kg/cm2pressure ) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing.
120Backfilling
121Back filling behind abutment , wing wall & return wall complete as per drawing & technical specification clause 1204.3.8Sandy material
122Filter media
123Providing & laying filter media with granular crushed aggregate as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment , wing wall,return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8
124Elastomeric Bearting
125Supplying, fitting & fixing in position true to line & level elastomeric bearing conforming to IRC:83 (Part-II) Section IX complete including all accessories as per drawings & technical specification Clause 1207.1
126Bearing with Steel attachment
127Supplying, fitting & fixing in position true to line & level elastomeric bearing conforming to IRC:83 (Part-II) Section IX complete including all accessories as per drawings & technical specification with all lifts and lead
128Expansion Joint
129Supplying and installing strip seal type Elastomeric expansion joint of approved design and make as per drawing and technical specification of MoRTHwith all lifts and lead upto 1000 m.
130RCC Superstructure
131Providing & laying reinforced cement concrete in superstructure as per drawing & technical specification Clause 800,RCC M-25For height from 5 m to 10 m
132Reinforcement for Superstructure
133Supplying, fitting & placing HYSD bar reinforcement in superstructure complete as per drawings & technical specifications Clauses 1002,1010 & 1202
134Handralling
135Construction of RCC railing of M 30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings ( No. SD / 202 ), including all formworks required and MoRT&H Technical Specification Clause 2703, 1500, 1600, 1700. (including centering, shuttering, staging etc. and reinforcement )
136Wearing Course
137Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawings & technical specifications Clauses 800, 900 & 1206.3
138Drainage spout
139Providing and placing in position drainage Spouts complete as per drawing ( SD / 205 ) and MoRT&H Technical Specification Clause 515, 2705.
140PCC below Approach slab
141P.C.C. M 15 oridinary grade (1:2.5:5) levelling course below approach slab complete as per drawing & technical specifications Clauses 800 and 1211P.C.C grade M 15Nominal mix 1:2.5:5 (Hand mixing)
142Approach slab
143Reinforced Cement Concrete M 25 grade approach slab including reinforcement & formwork complete as per drawing & technical specifications Clauses 800 & 1211
144Routine Load test
145Routine load test including supply of all tools & tackles required for testing, supply of kentledge, making all arrangement for testing, erection of kentledge, recording data analysing the data.
146RCC Bridge ( CH:2870 m)
147Excavation for structure
148Without dewatering.Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.Ordinary SoilUpto 3 m depth
149Filling in foundation
150Filling in foundation trenches as per drawing & technical specification Clause 305.3.9Earth filling (For marshy soil)
151Bored Cast-in-Situ piles 1200 mm dia , M-25 grade RCC pile excluding reinforcement complete as per drawing and technical specification and removal of excavated earth with all lifts and lead upto 1000 m.
152Reinforcement for Pile
153Supplying, fitting & placing HYSD bar reinforcement in foundation complete as per drawings & technical specifications Clauses 1000 & 1202
154Providing concrete for plain / reinforced concrete in open foundation complete as per drawing & technical specification clause 802,803,1202 and 1203Nomonal mix (1:2.5:5)(Hand mix)
155RCC M-25 in Pile cap
156Providing concrete for plain / reinforced concrete in open foundation complete as per drawing & technical specification clause 802,803,1202 and 1203RCC grade M-25
157Reinforcement for Pile cap
158Supplying, fitting & placing HYSD bar reinforcement in foundation complete as per drawings & technical specifications Clauses 1000 & 1202
159RCC M-25 in Abutment /Pier
160Plain / reinforced cement concrete in substructure complete as per drawing & technical specification Clause 802,804,805,806,807,1202 & 1204.RCC Grade M-25For height above 5 m upto 10 m
161Reinforcement for Abutment /Pier
162Supplying, fitting & placing HYSD bar reinforcement in substructure complete as per drawings & technical specifications Clauses 1002,1005,1010 & 1202
163Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or PVC pipe ( 110 mm OD of 6.0 Kg/cm2pressure ) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing.
164Backfilling
165Back filling behind abutment , wing wall & return wall complete as per drawing & technical specification clause 1204.3.8Sandy material
166Filter media
167Providing & laying filter media with granular crushed aggregate as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment , wing wall,return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8
168Elastomeric Bearting
169Supplying, fitting & fixing in position true to line & level elastomeric bearing conforming to IRC:83 (Part-II) Section IX complete including all accessories as per drawings & technical specification Clause 1207.1
170Bearing with Steel attachment
171Supplying, fitting & fixing in position true to line & level elastomeric bearing conforming to IRC:83 (Part-II) Section IX complete including all accessories as per drawings & technical specification with all lifts and lead
172Expansion Joint
173Supplying and installing strip seal type Elastomeric expansion joint of approved design and make as per drawing and technical specification of MoRTHwith all lifts and lead upto 1000 m.
174RCC Superstructure
175Providing & laying reinforced cement concrete in superstructure as per drawing & technical specification Clause 800,RCC M-25For height from 5 m to 10 m
176Reinforcement for Superstructure
177Supplying, fitting & placing HYSD bar reinforcement in superstructure complete as per drawings & technical specifications Clauses 1002,1010 & 1202
178Handralling
179Construction of RCC railing of M 30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings ( No. SD / 202 ), including all formworks required and MoRT&H Technical Specification Clause 2703, 1500, 1600, 1700. (including centering, shuttering, staging etc. and reinforcement )
180Wearing Course
181Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawings & technical specifications Clauses 800, 900 & 1206.3
182Drainage spout
183Providing and placing in position drainage Spouts complete as per drawing ( SD / 205 ) and MoRT&H Technical Specification Clause 515, 2705.
184PCC below Approach slab
185P.C.C. M 15 oridinary grade (1:2.5:5) levelling course below approach slab complete as per drawing & technical specifications Clauses 800 and 1211P.C.C grade M 15Nominal mix 1:2.5:5 (Hand mixing)
186Approach slab
187Reinforced Cement Concrete M 25 grade approach slab including reinforcement & formwork complete as per drawing & technical specifications Clauses 800 & 1211
188Routine Load test
189Routine load test including supply of all tools & tackles required for testing, supply of kentledge, making all arrangement for testing, erection of kentledge, recording data analysing the data.
190Maintenance
191Total for 1st year maintenance (including 5% inflation)
192Total for 2nd year maintenance (including 10% inflation)
193Total for 3rd year maintenance (including 15% inflation)
194Total for 4th year maintenance (including 20% inflation)
195Total for 5th year maintenance (including 25% inflation)

AI Tender Summary

OUR REF NO 28211064
AUTHORITY Government Departments
TENDER VALUE 5.44 Crore
LAST DATE 06-07-2021
Authority
Authority Name Public Works Department
Work Description Construction Of Road From Madhukumar To Tablajoy Including 2 Lsb Pmgsy Road Works
Basic Detail
Tender No 03/EO/TRRDA/2018-19
Bidding Type Tender
Location
City Chawmanu
State Tripura
Key Dates
Publish Date 16 Jun 2021
Submission Date 06 Jul 2021
Open Date 06 Jul 2021
Finance
Tender Value 5.44 Crore
Tender Fee 10000
EMD 10.90 Lakhs
Exemption Not Available
Document List
9433331d-09d7-40b5-9790-4e0ad5b48d84.html
BOQ_908338.xls
SBDDNIT03Call13th.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 16, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 06, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 06, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

9433331d-09d7-40b5-9790-4e0ad5b48d84.html

xls

BOQ_908338.xls

pdf

SBDDNIT03Call13th.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders