| 1 | 1 | M & L for serviceing solar Flat Plate collector by removing the flange plates, cleaning the collectors internally by using descaling solution, removing the blockages in the collectors complete and refixing the flange plates, testing for satisfactory function all as specified and directed. | | 45 | Each Job |
|---|
| 2 | 2 | M & L for seviceing solar manifold and tank by removing all the tubes in the monifold, cleaning the tubes internally, removing the blockages in the tubes and cleaning the tank and removing all the impurities, assembling and testing for satisfactory funtion all as specified and directed. | | 8 | Each Job |
|---|
| 3 | 3 | S & F heating element 25mm to 32mm dia, ISI marked for solar water heating plant of capacity 32 KW all as specified and directed by Engr in charge. | | 25 | Each |
|---|
| 4 | 4 | S & F Flat Plate collector Tank 100 LPD comprising of 2.5 mm GI/0.5 mm SS304 with rockwool insulation of 50 mm including aluminium cladding and removal of old unserviceable tank complete all as specified and directed. | | 2 | Each |
|---|
| 5 | 5 | S & F flange plates of size 25 mm dia suitable for flat plate collectors including taking down old unseviceable flange plate all specified and directed. | | 25 | Each |
|---|
| 6 | 6 | S & F Flat Plate collector Tank 200 LPD comprising of 2.5 mm GI/0.5 mm SS304 with rockwool insulation of 50 mm including aluminium cladding and removal of old unserviceable tank complete all as specified and directed. | | 1 | Each |
|---|
| 7 | 7 | S & F thermostat for solar water heating plant suitable size and ratings etc complete. | | 25 | Each |
|---|
| 8 | 8 | S & F flexible heat resistance rubber pipe (from inter connect plate collector to hot water tank) of size 25 mm to 32 mm dia etc with fixing clamp etc complete all as specified. | | 10 | Each |
|---|
| 9 | 9 | Taking down the collector from its position, removing the top glass of collector and carry out welding/brazing work to the collector and arresting the leakages in the collector, refixing top glass back, testing for satisfactory function all as specified and directed. | | 15 | Each Job |
|---|
| 10 | 10 | Taking down the old unserviceable solar flat plate collector by disconecting flange plates and rubber hose pipes and replacing with new flat plate collector of same size and model, connecting flange plates and rubber hose complete, testing for proper functioning all as specified and directed. | | 2 | Each Job |
|---|
| 11 | 11 | M & L for submain wiring with two runs of 6 sq mm single core multi stranded FR PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volts and including electrical grade PVC casing caping of desired colour not less than 1.2 mm and 25 mm wide & 4 sq mm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed including taking down old wiring.\nNote :- Two run of 6 Sqmm, and one run of 4 Sqmm and one run of casing caping shall be measured as one length | | 200 | RM |
|---|
| 12 | 12 | Steam Bath : Checking of electrical wire connection , level sensors, Heaters coil, earthing leakage, electronic circuits & control panel & safety arrangements of the water level & units. Cleaning the sensors, deposition of hard water tank & electrical, pneumatic valve. Proper insulation for the boilers including replacement of defective spares and fixing the same with new including testing one etc complete.\nNote - \n(a) Contractor has to visit the plant once in a month and carry out comprehensive maintenance as directed by Engr-in-Charge.\n(b) During emergency contractor has to visit the plant to rectify the fault without any extra cost to the Govt.\n(c) Any spares required during comprehensive maintenance and during emergency repairs shall be measured under respective item as \" Supply only) | | 11 | Each |
|---|
| 13 | 13 | Sauna Bath :- Checking of the heater coil, electronic temp control, calibrating temp, Accuracy, safety cut off the heater & cleaning the sensors of the electronic devices / equipments etc including replacement of defective spares and fixing the same with new including testing etc complete. \nNote -\n(a) Contractor has to visit the plant once in a month and carry out comprehensive maintenance as directed by Engr-in-Charge.\n(b) During emergency contractor has to visit the plant to rectify the fault without any extra cost to the Govt.\n(c) Any spares required during comprehensive maintenance and during emergency repairs shall be measured under respective item as \" Supply only) | | 11 | Each Job |
|---|
| 14 | 14 | Supply only 15 psi safety valve (Pressure relief valve)\n | | 2 | Each |
|---|
| 15 | 15 | Supply only 240 V 5 amps glass fuse | | 2 | Each |
|---|
| 16 | 16 | Supply only auto drain solonied valve 12 volts 6 watts for steam bath. | | 2 | Each |
|---|
| 17 | 17 | Supply only water inlet solonied valve 12 volt 6 watts for steam bath | | 2 | Each |
|---|
| 18 | 18 | Supply only Boiler insulation glass wool 25mm thick 40 Kg density with aluminium foil for one steam bath approx 3 Kg\n | | 2 | Job |
|---|
| 19 | 19 | Supply only steam water level circuit board & main relay board for steam bath. | | 2 | Each |
|---|
| 20 | 20 | Supply only steam generator power heating element 3000 watts for steam bath | | 3 | Each |
|---|
| 21 | 21 | Supply only sauna bath heating element 3 KW for sauna bath | | 3 | Each |
|---|
| 22 | 22 | Supply only mild steel powder coated exterior body including provision of analog ammeter, voltmeter LED indicators complete all as speciied and directed for steam bath. | | 1 | Each |
|---|
| 23 | 23 | Supply only high limit temperature (i.e 105 degree) switch thermostat for steam bath/sauna bath | | 2 | Each |
|---|
| 24 | 24 | Supply only stainless steel boiler tank as per existing make | | 2 | Each |
|---|
| 25 | 25 | Supply only water level sensor with Teflon collar & S/S No. Electrodes. | | 1 | Each |
|---|
| 26 | 26 | Supply only Temperature sensor including extension wire of length 6 metre for steam bath | | 2 | Each |
|---|
| 27 | 27 | Supply only Digital Control steam processor circuit board Model F-65/F-95 for steam/Sauna bath. \n | | 4 | Each |
|---|
| 28 | 28 | Supply only Digital Control panel ABS plastic cover for stam bath/sona bath.\n | | 1 | Each |
|---|
| 29 | 29 | Supply only Digital Control Key pad ovelay cover THD85E for steam bath.\n | | 1 | Each |
|---|
| 30 | 30 | Supply only step down Transformer with dual output primary 230 V and secondary 35 Volt 5 Amps for steam bath. | | 2 | Each |
|---|
| 31 | 31 | Supply only Mains power Terminal 4 way connector 63 amps\n | | 2 | Each |
|---|
| 32 | 32 | Supply only steam contactor 230 V coil 63 amps 3 phase 440 volt for steam plant. | | 3 | Each |
|---|
| 33 | 33 | Supply only silicon heater washer | | 2 | Each |
|---|
| 34 | 34 | Supply only power contactor 40 Amps 440 volts, 50 Hz | | 3 | Each |
|---|
| 35 | 35 | Supply only temperature thermostat range 30 to 110 degrees. | | 2 | Each |
|---|
| 36 | 36 | Supply only 4 way channel terminal strip connector 32 Amps. | | 2 | Each |
|---|
| 37 | 37 | Supply only high limit upto 95o c temprature switch 40 Amps rating for steam bath. | | 2 | Each |
|---|
| 38 | 38 | Supply only Sauna wooden R11 grade insulation 40 Kg density with aluminium foil.\nMake Yellow Cedar | | 4 | Sq ft |
|---|
| 39 | 39 | Supply only in repairs electronic sauna room temperature controller. | | 2 | Each |
|---|
| 40 | 40 | Supply only low density industrial Sauna heating element S/S, 316 Grade, 2000 watt. | | 2 | Each |
|---|
| 41 | 41 | Supply only flame proof wires 6 Sqmm for Sauna heater/steam bath. | | 20 | RM |
|---|
| 42 | 42 | Supply only Sauna room light switch 5 Amps. | | 3 | Each |
|---|
| 43 | 43 | Supply only Sauna room light switch dimmer | | 2 | Each |
|---|
| 44 | 44 | Supply only water softener KENT 300 ltr for re-generation of same model and make of exising complete all as directed. | | 3 | Each |
|---|
| 45 | 45 | Comprehensive maintenance of storage type electric water heater (geyser) of capacity 25 to 50 litres comprising of the following tasks at different locations including taking down, transportation to work shop ,opening the geyser, replacement of defective spares and reinstalling the same including testing as directed by Engineer-in-charge. \nMake : Bajaj, Ditz, Primer, Galco, Racold or any other make. | | 120 | Each Job |
|---|
| 46 | 45.1 | (a) Inspection of geysers includes taking down, transporting to works shop for repair, (dismantling) opening descaling, brushing cleaning of storage tank\n(b) Check and correct earth continuity of electrical items\n(c) Replacement of neon lamp / indicator lamp if defective.\n(d) Inspect over flow/vent pipes and remove blockage/ obstructions if any. \n(e) Examine water tightness tank after cleaning and necessary measures to make the same water tight if not. \n(f) Check thermostat for its proper functioning | | | |
|---|
| 47 | 45.2 | (g) Visual examination of fusible plug to ensure its intactness.\n(h) Checking of dead weight type high pressure release valve ( PRV ) by removing dead weight protection cleaning the seat and ensuring that the vent hole is not blocked / chocked\nj) Descalling of the immersion type heating element and cleaning with diluted hydrochloric acid and refixing.\nk) Checking and adjustments of pressure reducing valves, carrying out operation of all stop cocks & ensure free movement of all working parts.\nl) Replacement of the rubber / PVC gasket to ensure water tightness\nm) Testing of Geysers after repairs\nn) Replacement of defective components such as thermostat safety valves fusible plug, Heating elements, storage tank apparatus plate etc.\nNote:- Spare components will be measured and paid separately as supply only under relevent item of Sch 'A'. These parts shall be of the same make of which the geyser is in repair. | | | |
|---|
| 48 | 46 | Repair/checking to storage type water heater geyser of any capacity including replacement of required spares such as heating element thermostat, indicator, fusible plug dead weight,hot/cold water hose pipes incl any other etc repairs work at different locations at CME all as specified and directed by Engr in charge for the Make: Bajaj, Ditz, primer, galco, recold or any other make). Note : Spare components will be mesaured and paid seperately. | | 650 | Each Job |
|---|
| 49 | 47 | Supply only thermostat complete with temperture setting manually extra long (11 inches) ISI marked suitable for geysers 25 liters to 50 liters capacity | | 260 | Each |
|---|
| 50 | 48 | Supply only thermostat cut-out with knob complete at tripping 90 degree (+5%) Temperature of length (7 inches) ISI marked suitable for geysers 25 litres to 50 litres capacity. | | 260 | Each |
|---|
| 51 | 49 | Supply only air release valve / dead weight valve ISI marked suitable for 25 to 50 litres capacity geysers. | | 140 | Each |
|---|
| 52 | 50 | Supply only fusible plug ISI marked suitable for 25 to 50 litres capacity Geysers. | | 150 | Each |
|---|
| 53 | 51 | Supply only safety valve (tobe fixed on outlet connection) ISI marked suitable for 25, and 50 litres capacity geysers. | | 175 | Each |
|---|
| 54 | 52 | Supply only aparatus plate for geyser 25 Ltrs capacity | | 40 | Each |
|---|
| 55 | 53 | Supply only aparatus plate for geyser 50 Ltrs capacity | | 4 | Each |
|---|
| 56 | 54 | Supply only heating element upto 2 KW as required at site including rubber washers (ISI Marked) with round head coil | | 175 | Each |
|---|
| 57 | 55 | Supply only heating element upto 2 KW as required at site including rubber washers (ISI Marked) with small trangle head coil | | 200 | Each |
|---|
| 58 | 56 | Supply only heating element upto 2 KW as required at site including rubber washers (ISI Marked) with extra large trangular head coil | | 200 | Each |
|---|
| 59 | 57 | Supply only non return valve(NRV) brass of 15mm bore, after dismantling old unserviceable NRV of any size all as specified and directed. | | 45 | Each |
|---|
| 60 | 58 | S & F Hot/Cold water flexible hose pipe (ALLOY FLEXIBLE HOSE PIPE 1/2\") 12mm dia and 450/600mm long heavy duty covered with metal wires heat resistence with both ends PVC hexagonal check nut with washer to fixed on 15mm dia GI pipe all as specified and directed. | | 525 | Each |
|---|
| 61 | 59 | Supply only insulation material ( Glass Wool ) for geysers | | 10 | Kg |
|---|
| 62 | 60 | M & L for preparation of steel surface of geysers , apply putty to make the surface smooth/ even and applying one coat of synthetic enamel paint white including writing of MES Nos with black paint complete all as directed & for any size or capacity of geysers . | | 50 | Each |
|---|
| 63 | 61 | Taking down loose geysers of any capacity from wall & shifting to new place within 1 to 1.5m distance (available in same location) , refixing the geysers complete with grouting of bolts & all necessary pipe connections and making good the disturbed wall surfaces all as directed.\nNote :- GI tubing if required shall be measured and paid separately. | | 50 | Each |
|---|
| 64 | 62 | M & L to repair the leakge of copper inner tank of geysers of any capacity by gas welding/brazing for water tightness complete and test under pressure. | | 25 | Each |
|---|
| 65 | 63 | S & F single pole and neutral encloser with two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 volts. | | 50 | Each |
|---|
| 66 | 64 | S & F GI tubing (Medium grade) with all fitting and fixed to complete on wall and ceiling or laid in trenches of size 15mm bore incl taking down old unserviceable one all as specified and directed. | | 100 | RM |
|---|
| 67 | 65 | M & L for stop valve, cast copper alloy, screw down high pressure, crutch handle screwed both end for iron pipe, fancy type, chromium plated for 15mm bore pipe incl taking down old unserviceable one . | | 64 | Each |
|---|
| 68 | 66 | M & L for Bib tap,fancy type, chromium plated for 15mm bore pipe | | 62 | Each |
|---|
| 69 | 67 | S & F mild steel bottom/top covers for 25-50 litre capacity geysers. | | 20 | Each |
|---|
| 70 | 68 | S & F gasket rubber ring for heater plate of any size geyser. | | 30 | Each |
|---|
| 71 | 69 | S & F indicator lamp of geyser 25-50 litres capacity of RED/GREEN colour. | | 300 | Each |
|---|
| 72 | 70 | S & L PVC copper conductor cable 3 core 2.5 sq mm flexible multistranded 1100 V grade unsheathed cable. | | 250 | RM |
|---|
| 73 | 71 | M & L for switch socket combination 2 in one 3 pin 16 Amps 240 volts flush type complete all as speciied and directed. | | 60 | Each |
|---|
| 74 | 72 | M & L for socket outlet 3 pin incl PVC enclosure 240 volts controlled by one MCB SP 25 Amps, Make Havells or equivalent complete all as specified and directed. | | 100 | Each |
|---|
| 75 | 73 | M & L for Metal clad industrial pug top of cap 16 Amps | | 100 | Each |
|---|
| 76 | 74 | M & L for plug top porcelein 3 pin 15/16A 230 V AC supply | | 80 | Each |
|---|
| 77 | 75 | Supply & fix in repairs Gun metal, global or gate valves of size 15mm dia bore with iron wheel head, ISI marked screwed both ends for iron pipe and fixed complete all as specified | | 45 | Each |
|---|