Housing Urban and Rular Development Government Departments Closing in 0 days TDR #28186920

Construction Of Subsidiary Correctional Home At Chanchal- ( Part-2 ) - Balance Work . ( 1St Call )

Issued by Government Departments · Chanchal, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Jul 2021
0 days left
EMD
23.38 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chanchal → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Subsidiary Correctional Home At Chanchal- ( Part-2 ) - Balance Work . ( 1St Call )

BOQ

Name of Work: Construction Of Subsidiary Correctional Home At Chanchal- (Part-2) - Balance Work.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Civil worksBI01010001010000000000000515BI0100001112
22Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. Depth of excavation not execeeding 1,500 mmBI01010001010000000000000515BI01000011136000CU.M
33Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.BI01010001010000000000000515BI01000011142200CU.M
44Earth work in filling in foundation trenches or plinth with good earth, in layer not exceeding 150mm including watering and ramming etc. layer by layer complete a) With earth obtained from excavation of foundation.BI01010001010000000000000515BI01000011157900CU.M
55(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)BI01010001010000000000000515BI01000011166500CU.M
66Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete.\n(Payment will be made on profile measurement before and after the work)\nWith carried earth arranged by the contractor\nwithin a radius exceeding 3 km. but not exceeding 5\nkm. including the cost of carried earth.BI01010001010000000000000515BI010000111712400Cum
77Removal of rubbish,earth etc. from the working\nsite and disposal of the same beyond the\ncompound, in conformity with the Municipal /\nCorporation Rules for such disposal, loading into\ntruck and cleaning the site in all respect as per\ndirection of Engineer in chargBI01010001010000000000000515BI01000011181000Cum
88Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level, and filling joints with powered or local sand.BI01010001010000000000000515BI01000011194132.5SQ.M
99(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering)\nIn ground floor (B)With PAKUR Variety 1:3:6BI01010001010000000000000515BI0100001120358CU.M
1010Controlled Cement concrete with well graded stone chips (20 mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.\n[using concrete mixture] \n(b) M 25 Grade \n(i) Pakur VarietyGROUND FLOORBI01010001010000000000000515BI01000011211500CU.M
1111Controlled Cement concrete with well graded stone chips (20 mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.\n[using concrete mixture] \n(b) M 25 Grade \n(i) Pakur Variety1ST FLOORBI01010001010000000000000515BI0100001122400CU.M
1212Controlled Cement concrete with well graded stone chips (20 mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.\n[using concrete mixture] \n(b) M 25 Grade \n(i) Pakur VarietySECOND FLOORBI01010001010000000000000515BI010000112350CU.M
1313Controlled Cement concrete with well graded stone chips (20 mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.\n[using concrete mixture] \n(b) M 25 Grade THIRD FLOORBI01010001010000000000000515BI01000011245CU.M
1414Controlled Cement concrete with well graded stone chips (20 mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.\n[using concrete mixture] \n(b) M 20 Grade \n(i) Pakur VarietyBI01010001010000000000000515BI0100001125300CU.M
1515Dismantling R.C. floor, roof, beams etc. including\ncutting rods and removing rubbish as directed\nwithin a lead of 75 m. including stacking of steel\nbars.\n(a) In ground floor including roof.BI01010001010000000000000515BI010000112610CU.M
1616Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a)9 to 12 mm thick approved quality ply board shuttering in any concrete work GROUND FLOORBI01010001010000000000000515BI01000011277000SQ.M
1717Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a)9 to 12 mm thick approved quality ply board shuttering in any concrete work 1ST FLOORBI01010001010000000000000515BI01000011283500SQ.M
1818Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a)9 to 12 mm thick approved quality ply board shuttering in any concrete work 2nd FLOORBI01010001010000000000000515BI0100001129350SQ.M
1919Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a)9 to 12 mm thick approved quality ply board shuttering in any concrete work 3rd floorBI01010001010000000000000515BI010000113050SQ.M
2020Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.For work in foundation,basement and and upto roof of Ground Floor. (i) Tor Steel/Mild Steel.SAIL/TATA/RINLBI01010001010000000000000515BI0100001131200M.T
2121Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.(i) Tor Steel/Mild Steel.SAIL/TATA/RINL1ST FLOORBI01010001010000000000000515BI010000113250M.T
2222Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.(i) Tor Steel/Mild Steel.SAIL/TATA/RINLSECOND FLOORBI01010001010000000000000515BI01000011335M.T
2323Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.(i) Tor Steel/Mild Steel.SAIL/TATA/RINL3rd floorBI01010001010000000000000515BI01000011340.5M.T
2424Brick work with 1st class bricks in cement mortar (1:6) in (a) In foundation and plinthBI01010001010000000000000515BI0100001135772CU.M
2525Brick work with 1st class bricks in cement mortar (1:6) in Super Structure ,Ground FloorBI01010001010000000000000515BI0100001136350CU.M
2626Brick work with 1st class bricks in cement mortar (1:6) in 1ST FLOORBI01010001010000000000000515BI0100001137250CU.M
2727Brick work with 1st class bricks in cement mortar (1:6) in 2nd floorBI01010001010000000000000515BI010000113830CU.M
2828Brick work with 1st class bricks in cement mortar (1:6) in 3rd floorBI01010001010000000000000515BI010000113921CU.M
2929125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in Ground Floor. Extra for using approved H.B. netting in every 3rd layer.Ground Floor.BI01010001010000000000000515BI0100001140920sqm
3030125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in Ground Floor. Extra for using approved H.B. netting in every 3rd layer1ST FLOORBI01010001010000000000000515BI0100001141480sqm
3131125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in Ground Floor. Extra for using approved H.B. netting in every 3rd layer2nd floorBI01010001010000000000000515BI0100001142235sqm
3232125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in Ground Floor. Extra for using approved H.B. netting in every 3rd layer3rd floorBI01010001010000000000000515BI010000114330sqm
333325mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item NO 60, polymer based paint as per item 59 (a) of Section (C).BI01010001010000000000000515BI0100001144200SQ.M
3434Labour for Chipping of concrete surface before taking up Plastering work.BI01010001010000000000000515BI010000114510000SQ.M
3535Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : MalayasianAt Ground FloorBI01010001010000000000000515BI01000011466CU.M
3636Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malayasian1ST FLOORBI01010001010000000000000515BI01000011475CU.M
3737Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malayasian 2nd floorBI01010001010000000000000515BI01000011482CU.M
3838Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.\nIn ground floor.(In case of non-supply of single plank, penal rate of reduction of 20% will be made)\n(iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.\n(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.GROUND FLOORBI01010001010000000000000515BI0100001149250SQ.M
3939Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.\nIn ground floor.(In case of non-supply of single plank, penal rate of reduction of 20% will be made)\n(iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.\n(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.1ST FLOORBI01010001010000000000000515BI0100001150200SQ.M
4040Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.\nIn ground floor.(In case of non-supply of single plank, penal rate of reduction of 20% will be made)\n(iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.\n(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.2nd floorBI01010001010000000000000515BI010000115160SQ.M
4141Shutters of 2/3rd panel and 1/3rd glazed of doors and windows as per design\n(each panel consisting of a single plank without joint and with ordinary glass of\n7.4kg. Per sq.m./3mm thick) fitted with putty bed and teak wood beads and nails\nincluding fitting and fixing shutters in position but excluding the cost of glass,\nputty, teak bead, nails, hinges etc. and other fittings, in ground floor. 35mm thick shutters with 19mm thick panel Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak. GROUND FLOORBI01010001010000000000000515BI010000115262SQ.M
4242Shutters of 2/3rd panel and 1/3rd glazed of doors and windows as per design\n(each panel consisting of a single plank without joint and with ordinary glass of\n7.4kg. Per sq.m./3mm thick) fitted with putty bed and teak wood beads and nails\nincluding fitting and fixing shutters in position but excluding the cost of glass,\nputty, teak bead, nails, hinges etc. and other fittings, in ground floor. 35mm thick shutters with 19mm thick panel Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak. 1ST FLOORBI01010001010000000000000515BI010000115344SQ.M
4343Supplying solid flush type doors of commercial quality, the timber frame\nconsisting of top and bottom rails and side styles of well seasoned timber 65mm\nwide each and the entire frame fitted with 37.5mm wide battens places both ways\nin order to make the door of solid core and internal lipping with Garjan or\nsimilar wood veneers using phenol formaldehyde as glue etc. complete, including\nfitting, fixing shutters in position but excluding the cost of hinges and other\nfittings in ground floor.: 35mm thick shutters (single leaf)GROUND FLOORBI01010001010000000000000515BI01000011545SQ.M
4444Supplying solid flush type doors of commercial quality, the timber frame\nconsisting of top and bottom rails and side styles of well seasoned timber 65mm\nwide each and the entire frame fitted with 37.5mm wide battens places both ways\nin order to make the door of solid core and internal lipping with Garjan or\nsimilar wood veneers using phenol formaldehyde as glue etc. complete, including\nfitting, fixing shutters in position but excluding the cost of hinges and other\nfittings in ground floor.: 35mm thick shutters (single leaf)1ST FLOORBI01010001010000000000000515BI01000011555SQ.M
4545Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]. (ii) c/ With 1:4 cement mortar ,b) 10 mm thick plaster. Ceiling Plaster. GROUND FLOORBI01010001010000000000000515BI01000011563000SQ.M
4646Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]. (ii) c/ With 1:4 cement mortar ,b) 10 mm thick plaster. Ceiling Plaster.1ST FLOORBI01010001010000000000000515BI01000011572400SQ.M
4747Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]. (ii) c/ With 1:4 cement mortar ,b) 10 mm thick plaster. Ceiling Plaster.2nd floorBI01010001010000000000000515BI0100001158300SQ.M
4848Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]. (ii) c/ With 1:4 cement mortar ,b) 10 mm thick plaster. Ceiling Plaster.3rd floorBI01010001010000000000000515BI010000115930SQ.M
4949Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:4 cement mortar a) 20mm thick plaster OUTSIDE. GROUND FLOORBI01010001010000000000000515BI01000011609957.5SQ.M
5050Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:4 cement mortar a) 20mm thick plaster1ST FLOORBI01010001010000000000000515BI01000011612700SQ.M
5151Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:4 cement mortar a) 20mm thick plaster2nd floorBI01010001010000000000000515BI0100001162800SQ.M
5252Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:4 cement mortar a) 20mm thick plaster3rd floorBI01010001010000000000000515BI0100001163300SQ.M
5353Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:4 cement mortar b) 15mm thick plaster INSIDEGROUND FLOORBI01010001010000000000000515BI01000011644300SQ.M
5454Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:4 cement mortar b) 15mm thick plaster INSIDE1ST FLOORBI01010001010000000000000515BI01000011653400SQ.M
5555Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:4 cement mortar b) 15mm thick plaster INSIDE2nd floorBI01010001010000000000000515BI01000011661000SQ.M
5656Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:4 cement mortar b) 15mm thick plaster INSIDE3rd floorBI01010001010000000000000515BI010000116750SQ.M
5757Extra for fluted, corrugated or ribbed plaster (over rate of corresponding rate of plaster). (Cement 0.135 Cu.m/100Sq.m)BI01010001010000000000000515BI0100001168150SQ.M
5858Making V-groove line ( 6 mm. wide, 6 mm. deep) in plastered surface.BI01010001010000000000000515BI0100001169300Mtr
5959Making V-groove line ( 12 mm wide,12 mm deep) in plastered surface.BI01010001010000000000000515BI0100001170300Mtr
6060Neat Cement Punning above 1.5mm thick in Wall dado,Window Sill Floor and Drain etc Note Cement 0.152 cum 100 SqmtsBI01010001010000000000000515BI01000011717507.5SQ.M
6161Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) All floors InsideBI01010001010000000000000515BI01000011724000SQ.M
6262Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coat Water based interior grade Acrylic Primer All Floors InsideBI01010001010000000000000515BI01000011734000SQ.M
6363Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.\nTwo Coats All Floors Inside\"\nBI01010001010000000000000515BI01000011744000SQ.M
6464White washing including cleaning and smoothening surface thoroughly.(b) Three coats (to be done on specificinstruction). InsideGROUND FLOORBI01010001010000000000000515BI010000117510145SQ.M
6565Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (Two Coat)GROUND FLOORBI01010001010000000000000515BI01000011765000SQ.M
6666Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (Two Coat)1ST FLOORBI01010001010000000000000515BI01000011773000SQ.M
6767Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (Two Coat)2nd floorBI01010001010000000000000515BI0100001178650SQ.M
6868Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (Two Coat)3rd flooorBI01010001010000000000000515BI0100001179300SQ.M
6969Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (Two Coat)GROUND FLOOR\nNormal Acrylic EmulsionBI01010001010000000000000515BI01000011805000SQ.M
7070Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (Two Coat)1ST FLOOR\nNormal Acrylic EmulsionBI01010001010000000000000515BI01000011813000SQ.M
7171Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (Two Coat)2nd floor \nNormal Acrylic EmulsionBI01010001010000000000000515BI0100001182650SQ.M
7272Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (Two Coat)3rd floor \nNormal Acrylic EmulsionBI01010001010000000000000515BI0100001183300SQ.M
7373Primming One coat on Timber or Plaster surface with Synthetic Oil bound Primer of approved Quality inclusing smooting surface by sand Papering etcBI01010001010000000000000515BI01000011841900SQ.M
7474(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)BI01010001010000000000000515BI01000011851900SQ.M
7575(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.BI01010001010000000000000515BI01000011863000SQ.M
7676Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessaryb) iv) On Steel and other Metal Surface Two coat with any shade except whiteBI01010001010000000000000515BI01000011873000SQ.M
7777Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) \n= 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water\nand polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all\nother incidental charges complete as per direction of Engineerin-Charge. (Note: This work should not be executed without\nspecific permission of Superintending Engineer)ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5\nmm thick) GROUND FLOORBI01010001010000000000000515BI0100001188240SQ.M
7878Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) \n= 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water\nand polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all\nother incidental charges complete as per direction of Engineerin-Charge. (Note: This work should not be executed without\nspecific permission of Superintending Engineer)ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5\nmm thick)1ST FLOORBI01010001010000000000000515BI0100001189320SQ.M
7979Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick\nwith uniform texture & without decorative veins in columns,\nwall, facia etc. with 15 mm thick [avg] cement mortar (1:2)\nincluding making suitable arrangements to hold the stones\nproperly by brass / copper hooks including pointing in cement\nmortar (1:2) (1 white cement : 2 marble dust) with admixture\nof pigment matching the stone shades all complete as per\ndirection of the Engineer-in-charge including cost of all\nmaterials, labours, scaffolding, staging ,curing and\nroughening of concrete surface complete. Area of each\nGranite slab > 0.6 upto 1.0 square metre.\n[Using cement slurry at back side of granite @ 4.4 kg/sq.m &\nwhite cement slurry for joint filling @ 1.8 kg/sq.m]GROUND FLOORBI01010001010000000000000515BI010000119065SQ.M
8080Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick\nwith uniform texture & without decorative veins in columns,\nwall, facia etc. with 15 mm thick [avg] cement mortar (1:2)\nincluding making suitable arrangements to hold the stones\nproperly by brass / copper hooks including pointing in cement\nmortar (1:2) (1 white cement : 2 marble dust) with admixture\nof pigment matching the stone shades all complete as per\ndirection of the Engineer-in-charge including cost of all\nmaterials, labours, scaffolding, staging ,curing and\nroughening of concrete surface complete. Area of each\nGranite slab > 0.6 upto 1.0 square metre.\n[Using cement slurry at back side of granite @ 4.4 kg/sq.m &\nwhite cement slurry for joint filling @ 1.8 kg/sq.m]1ST FLOORBI01010001010000000000000515BI0100001191110SQ.M
8181Providing and fixing of false ceiling with powder coated exposed G.I. grid\nsuspension system (E-Grid U-1520 or equivalent load carrying capacity with mid\nspan deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c )\nconsisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and\nWall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the\nperimeter of the wall by steel screws with distance 300mm c/c. The Main Runners\nto be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut\nslots of Main Runner at a regular interval of 600 mm to form a modular grid of\n1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed\nperpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X\n600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia\nG.I. wire from purlins / soffit. 15mm thick OW Acoustic Board (Mineral Fiber\nAcoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRC\nvalue > 0.65 should be placed in the Grid module to form a False Ceiling. All\ncomplete as per the drawing & directions of Engineer-in-charge.\nIn ground floor.\na) Acoustic False Ceiling (with 15mm thick OW Acoustic Board and E-Grid U1520)BI01010001010000000000000515BI0100001192185SQ.M
828218 mm. to 22 mm. thick, kota stone slab setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m] Extra cost of labour for prefinished and premoulded Nosing to treads of steps,GROUND FLOORBI01010001010000000000000515BI01000011932200SQ.M
838318 mm. to 22 mm. thick, kota stone slab setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m] Extra cost of labour for prefinished and premoulded Nosing to treads of steps,1ST FLOORBI01010001010000000000000515BI01000011941700SQ.M
848418 mm. to 22 mm. thick, kota stone slab setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m] Extra cost of labour for prefinished and premoulded Nosing to treads of steps,2nd floorBI01010001010000000000000515BI0100001195500SQ.M
858518 mm. to 22 mm. thick, kota stone slab setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m] Extra cost of labour for prefinished and premoulded Nosing to treads of steps,3rd floorBI01010001010000000000000515BI010000119612SQ.M
8686Extra cost of labour for prefinished & premoulded nosing to trades of steps,railing,window sill etc of kota stoneBI01010001010000000000000515BI01000011972600Mtr
8787Extra cost of labour for grinding kota stone floor in trades & riser of stepsBI01010001010000000000000515BI0100001198400SQ.M
8888Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture of pigments matching the stone shadeincluding grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]GROUND FLOORBI01010001010000000000000515BI0100001199300SQ.M
8989Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture of pigments matching the stone shadeincluding grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]1ST FLOORBI01010001010000000000000515BI0100001200220SQ.M
9090Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture of pigments matching the stone shadeincluding grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]2nd floorBI01010001010000000000000515BI010000120165SQ.M
9191Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture of pigments matching the stone shadeincluding grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]3rd floorBI01010001010000000000000515BI01000012022SQ.M
9292Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative FLOORGROUND FLOORBI01010001010000000000000515BI0100001203250SQ.M
9393Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative FLOOR1ST FLOORBI01010001010000000000000515BI0100001204150SQ.M
9494Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative FLOOR2nd floorBI01010001010000000000000515BI010000120525SQ.M
9595Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:3) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative WALLGROUND FLOORBI01010001010000000000000515BI01000012061000SQ.M
9696Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:3) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative WALL1ST FLOORBI01010001010000000000000515BI0100001207500SQ.M
9797Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:3) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative WALL2nd floorBI01010001010000000000000515BI010000120850SQ.M
9898Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of each tile above 0.09 Sq.m (i) Coloured decorative FLOORGROUND FLOORBI01010001010000000000000515BI010000120925SQ.M
9999Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of each tile above 0.09 Sq.m (i) Coloured decorative FLOOR1ST FLOORBI01010001010000000000000515BI010000121030SQ.M
100100Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:3) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of each tile above 0.09 Sq.m (i) Coloured decorative WALLGROUND FLOORBI01010001010000000000000515BI010000121180SQ.M
101101Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:3) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of each tile above 0.09 Sq.m (i) Coloured decorative WALL1ST FLOORBI01010001010000000000000515BI010000121250SQ.M
102102Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 35 mm. thickGROUND FLOORBI01010001010000000000000515BI0100001213100SQ.M
103103Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 35 mm. thick1ST FLOORBI01010001010000000000000515BI010000121450SQ.M
104104Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 35 mm. thick2nd floorBI01010001010000000000000515BI010000121550SQ.M
105105Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 35 mm. thick3rd floorBI01010001010000000000000515BI010000121650SQ.M
106106Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor.Slab Thickness above 25 mm and upto 37.5 mmGROUND FLOORBI01010001010000000000000515BI010000121720SQ.M
107107Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. (ii) 66mm x 90mmBI01010001010000000000000515BI0100001218350Mtr
108108Supplying fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of department of science and technology (DST) to satisfy IS:4020 door testing performance criteria 32 mm thkBI01010001010000000000000515BI0100001219105Sqmt
109109Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc,including hoisting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. In Ground floor Flash butt welded windows and ventilators (No shop priming will be allowed to facilitate.\nOpenable steel windows as per IS sizes with side hung shutters and horizotal glazing bars with/without fixed type ventilators.[The extra rate admissible for the openable portion only]. GROUND FLOORBI01010001010000000000000515BI0100001220270SQ.M
110110Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc,including hoisting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. In Ground floor Flash butt welded windows and ventilators (No shop priming will be allowed to facilitate.Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars with/without fixed type ventilators.[The extra rate admissible for the openable portion only].1ST FLOORBI01010001010000000000000515BI0100001221115SQ.M
111111Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc,including hoisting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. In Ground floor Flash butt welded windows and ventilators (No shop priming will be allowed to facilitate.Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars with/without fixed type ventilators.[The extra rate admissible for the openable portion only].2nd floorBI01010001010000000000000515BI010000122235SQ.M
112112Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc,including hoisting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. In Ground floor Flash butt welded windows and ventilators (No shop priming will be allowed to facilitate.Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars with/without fixed type ventilators.[The extra rate admissible for the openable portion only].3rd floorBI01010001010000000000000515BI01000012232SQ.M
113113Fixed type steel windows as per IS Sizes with horizontal glazing barsGROUND FLOORBI01010001010000000000000515BI010000122425SQ.M
114114Fixed type steel windows as per IS Sizes with horizontal glazing bars1st FLOORBI01010001010000000000000515BI010000122510SQ.M
115115Fixed type steel windows as per IS Sizes with horizontal glazing bars2nd FLOORBI01010001010000000000000515BI01000012262SQ.M
116116Fixed type steel windows as per IS Sizes with horizontal glazing bars3rd FlOORBI01010001010000000000000515BI01000012272SQ.M
117117Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-incharge.\n\nWeight of Strainless Steel railing per metre 6.5 Kg (approx)BI01010001010000000000000515BI010000122860SQ.M
118118Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately).\n(a) 40mm X 6mm, 250mm LengthBI01010001010000000000000515BI01000012292000Each
119119Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) ii) 4 mm thickBI01010001010000000000000515BI0100001230500SQ.M
120120Extra for fixing glass panes in steel windowBI01010001010000000000000515BI0100001231500SQ.M
121121Supplying bubble free float glass of approved make and brand\nconforming to IS: 2835-1987; \n(A) clear, toughened glass conforming to IS: 2553-1992 (part-II) 10mm thickBI01010001010000000000000515BI010000123210SQ.M
122122Two point nose aluminium handle including fitting and fixing.BI01010001010000000000000515BI0100001233350Each
123123steel peg stay 300 mm long including fitting and fixing.BI01010001010000000000000515BI01000012341000Each
124124Supplying anodised aluminium catch hook with eye fitted and fixed to shutter and\nchowkat complete of best quality:\n(i) 225mm long.BI01010001010000000000000515BI01000012351000Each
125125(a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.BI01010001010000000000000515BI01000012365SQ.M
126126a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq. mtr.GROUND FLOORBI01010001010000000000000515BI0100001237300Qntl
127127a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq. mtr.1ST FLOORBI01010001010000000000000515BI0100001238200Qntl
128128a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq. mtr.2nd floorBI01010001010000000000000515BI010000123960Qntl
129129Square or hexagonal mesh netting made with 18 B.W.G. galvanised wire, fitted\nand fixed complete as per design (excluding the supporting framework but\nincluding local sal wood battens of size 37.5mmx25mm).\n (c) 37.5mm meshBI01010001010000000000000515BI0100001240200SQ.M
130130M.S. works in framed gratings of window etc.made of round or\nsquare bars and frame work or M.S. flats (with the bars securely\nfixed to the flat bar frame) with or without intermediate flat bar\nstiffener and fixed with necessary screws etc. complete, as directed.BI01010001010000000000000515BI010000124110Qntl
131131Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. IN GROUND FLOORBI01010001010000000000000515BI010000124281SQ.M
132132Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark 100mm X 50mm X 1.25mmBI01010001010000000000000515BI01000012432050Each
133133i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.250mm longBI01010001010000000000000515BI0100001244200Each
134134Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with\n16mm dia rod with centre bolt and round fitting..250mm longBI01010001010000000000000515BI010000124520Each
135135(ii) Anodised aluminium floor door stopperBI01010001010000000000000515BI0100001246200Each
136136Godrej Hydraulic door closer fitted and fixed complete.Medium TypeBI01010001010000000000000515BI0100001247150Each
137137Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including\nfitting & fixing complete.BI01010001010000000000000515BI010000124820Each
138138Iron door ring of approved quality fitted and fixed with nut and washer\ncomplete. 50mm dia.BI01010001010000000000000515BI01000012491000Each
139139Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. 300 mm long X 12mm dia bolt.BI01010001010000000000000515BI01000012501050Each
140140Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal / Round rod) (v) 125 mm grip x 12 mm dia rod.BI01010001010000000000000515BI01000012511050Each
141141Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having\nadhesive & waterproofing properties by mixing in proportion (1 liquid: 4\ncementitious material) or as per manufacturer's specification for water\nproofing layer in water tank etc. (No Departmental Cement is required)BI01010001010000000000000515BI01000012522200SQ.M
142142Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (10 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.\nPakur VarietyGround FloorBI01010001010000000000000515BI010000125315Cum
143143Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (10 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.\nPakur VarietyFirst FloorBI01010001010000000000000515BI010000125440Cum
144144Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (10 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.\nPakur VarietySecond FloorBI01010001010000000000000515BI010000125545Cum
145145Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (10 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.\nPakur VarietyThird FloorBI01010001010000000000000515BI01000012562Cum
146146Supplying dividing strip fitted and fixed with cement mortar\n(1:3) in mosaic or patent stone floor, dado etc. complete as per direction of the Engineer-in-charge. (i) Glass - 3mm. Thick 25 mm. wide stripBI01010001010000000000000515BI01000012571000mtr
147147Supplying, fitting and fixing cast iron heavy type spiral staircase of approved design with 50 mm.dia. Stem and C.I. Steps 150 mm as per design 900 mm. high C.I, railing including necessary M.S. tie of suitable section embedded to wall with cement concrete (1:2:4) including cost of intermediate C.I. platform secured with necessary tie to stem and wall with cement concrete (1:2:4) including fixing the stem in ground with cement concrete (1:3:6) complete in all respect with all labour and materials. (Payment to be made on vertical height in between 1st step and top platform.) (b) With 1200 mm.dia. wellBI01010001010000000000000515BI01000012587mtr
148148M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.GROUND FLOORBI01010001010000000000000515BI010000125950Qntl
149149M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.1ST FLOORBI01010001010000000000000515BI010000126040Qntl
150150M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.2nd floorBI01010001010000000000000515BI010000126115Qntl
151151Locking arrangement for Jail type doors including supplying fitting and fixing in position complete as per approved design.GROUND FLOORBI01010001010000000000000515BI0100001262310Kg
152152M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length,fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make andbrand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.I) For structural members of specified sections weighing less than 22.5 Kg./mBI01010001010000000000000515BI01000012630.5MT
153153Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.BI01010001010000000000000515BI0100001264350SQ.M
154154Welding in M.S. structural work with gas or electric: continuous weldBI01010001010000000000000515BI010000126550cm run
155155Supplying, fitting, fixing in position rails on any surface.BI01010001010000000000000515BI010000126625Kg
156156M.S. structural works in roof trusses with tubular sections\nconforming to IS: 806-1957 & IS: 1161- 1958 connected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc.\nPayment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work.Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.\nFor trusses spanning up to 12.00 m\nAt roof truss In ground floorBI01010001010000000000000515BI01000012670.5Kg
157157Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). With 0.5 mm thick sheetBI01010001010000000000000515BI010000126850SQ.M
158158Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifable concentrates (1% concentration) with water by weight at the rate of 5 litres /sqm.of the surface before sand bed or subgrade is laid. Holes upto 50 mm to 75 mm deep at 150 mm centre to centre both ways shall be made with 12 mm diameter mild steel rod on the surface to facilitate saturation of the soil with chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. (Mode of measurement will be per sq.m. of plan area of plinth treated.BI01010001010000000000000515BI01000012692200Sqmt
159159Supplying and fixing grasses tiles of grass Maxican Carpet/Selection No. 1 Healthy & fresh grasses (size 1'x1' or bigger) including watering and maintenance of the lawn for\n30 days or more till the grass forms a thick lawn free from wees and fit for mowing including supplying good earth as required by Engineer-in-charge. (Rate includes supply of labour, tools & plants including materials)BI01010001010000000000000515BI01000012701600Sqmt
160160Planting of trees ( Avenue plants) in 0.60m dia holea, 1m\ndeep dug in the ground, mixing the soil with decayed farm\nyard/sludge manure. This includes supply of labour, tools &\nplants including materials but excluding cost of tree.BI01010001010000000000000515BI01000012711000Each
161161Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary. (a) Depth up to 150mm.BI01010001010000000000000515BI01000012721200Sqmt
162162(b) For each additional Depth of 150mm and part \nthereof.BI01010001010000000000000515BI01000012731200Sqmt
163163Granular Sub-base with Graded Material, (Table:- 400-1):- Mix in place Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MORT&H (5th Revision). Grading - G.S.B.BI01010001010000000000000515BI0100001274300CUM
164164Wet Mix Macadam Base Course\nProviding, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including screening of aggregates and \ngranular materials, premixing the material with water at OMC in Wet Mix Plant, carriage of mixed material \nby tipper to site, laying in uniform layers with Paver in Sub- base / Base course on well prepared surface and compacting with Vibratory Roller to achieve the desired density, including supply of all materials, machinery, fuel and lubricants, including incidental \ncosts for lighting, guarding, barricading, making earthen bundh to protect the edges including cost of quality control complete as per Clause 406 of \nSpecifications for Road & Bridge Works of MoRT&H \n(5th Revision).BI01010001010000000000000515BI0100001275180CUM
165165Providing and filling joint sealing compound as per drawing and technical specifications with coarse sand and 6% bitumen by weightBI01010001010000000000000515BI0100001276500RM
166166Providing and applying primer coat with Cationic Bitumen Emulsion of approved grade conforming to IS: 8887-1978 and requisite quantity on prepared surface of granular base including cleaning of road surface and spraying primer using Mechanical means including cost and carriage of bitumen emulsion and all other incidental costs of work complete as per Clause 502 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).\n(i) For WBM / WMM Surface:\n(with primer @ 0.85 kg/sqm)BI01010001010000000000000515BI01000012771200Sqmt
167167Providing, laying and rolling of Open - graded premix surfacing of 20 mm thickness composed of 13.2 mm (@ 0.018 m³ per m²) and 11.2 mm (@ 0.009 m³ per m²) size stone aggregates, including thoroughly cleaning of the surface, screening, cleaning and pre-heating stone chips and fully pre-coating the same either using viscosity grade paving bitumen or cut-back or emulsion, carrying the mixture by any suitable arrangements, laying the mixture uniformly over the surface, including line, grade and level to serve as wearing course on a previously prepared base, including mixing in Mobile Hot Mix Plant (Light Duty) and thoroughly rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades including the cost and carriage of stone chips and matrix, heating the matrix, preheating the aggregates to required temperature and including the hire charges of Mobile Hot Mix Plant (Light Duty) and other machinery, pay of operators, cost of fuel and lubricants etc. complete to be followed by seal coat of either Type A or Type B as per Technical Specification Clause 508 for Rural Roads of MORDBI01010001010000000000000515BI01000012781200Sqmt
168168Seal Coat (Type-B) :- Providing and laying Premixed Seal Coat (Type B) with approved quality sand/grit @ 0.6 m3/ 100 m2 and bitumen binder on thoroughly cleaned black top surface coated with tack coat, including heating and mixing cleaned sand/grit (100 % passing through 2.36 mm sieve and retained on 180 micron sieve) uniformly with bitumen binder, laying and spreading the mix at an uniform rate using suitable means, brushing the surface, if necessary, to ensure uniformity, followed by rolling with power roller including the cost and carriage of binder and aggregates, cost of heating the binder and aggregates and all other incidental charges, cost of fuel and lubricants, including hire charges of machineries, tools & plants required for construction and quality control complete as per Clause 511 of Specifications for Road & Bridge Works of MORT&H (5th Revision). \nBy Mechanical Means. With Hot Bitumen Binder (@ 6.80 kg / 10 sqm.) On freshly laid premixed carpet with out tack coat.BI01010001010000000000000515BI01000012791200Sqmt
169169Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\n(A) (i) Single Socketed 3 Meter Length110 mmBI01010001010000000000000515BI0100001280500Mtr
170170Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\n(A) (i) Single Socketed 3 Meter Length160 mmBI01010001010000000000000515BI0100001281500Mtr
171171Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\n(A) (i) Double Socketed 3 Meter Length110 mmBI01010001010000000000000515BI0100001282500Mtr
172172Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992\n(A) (i) Double Socketed 3 Meter Length160 mmBI01010001010000000000000515BI0100001283500Mtr
173173Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)\n50 mm(Main Riser)BI01010001010000000000000515BI0100001284400Mtr
174174Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)40 mm(Main Riser)BI01010001010000000000000515BI0100001285250Mtr
175175Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)32mmBI01010001010000000000000515BI0100001286250Mtr
176176Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)20 mmBI01010001010000000000000515BI0100001287600Mtr
177177Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)25 mmBI01010001010000000000000515BI0100001288450Mtr
178178Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Concealed work 20 mmBI01010001010000000000000515BI0100001289350Mtr
179179Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Concealed work15 mmBI01010001010000000000000515BI0100001290600Mtr
180180Supplying & laying Double Wall Corrugated (with external annular\ncorrugation and smooth internal walls) High Density Polyethelene Pipes\nconforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with\nRing Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR\nvalue not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application. 150mm internal dia.BI01010001010000000000000515BI0100001291300Mtr
181181Supplying & laying Double Wall Corrugated (with external annular\ncorrugation and smooth internal walls) High Density Polyethelene Pipes\nconforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with\nRing Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR\nvalue not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application. 300mm internal dia.BI01010001010000000000000515BI0100001292200Mtr
182182Supplying & laying Double Wall Corrugated (with external annular\ncorrugation and smooth internal walls) High Density Polyethelene Pipes\nconforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with\nRing Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR\nvalue not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application. 400mm internal diaBI01010001010000000000000515BI0100001293150Mtr
183183Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).50mmBI01010001010000000000000515BI010000129430Each
184184Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).40mmBI01010001010000000000000515BI010000129530Each
185185Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).32mmBI01010001010000000000000515BI010000129630Each
186186Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).25 mmBI01010001010000000000000515BI010000129730Each
187187Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).20 mmBI01010001010000000000000515BI010000129830Each
188188Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes \n& fittings conforming to IS-15778: 2007 Ball Valve50mmBI01010001010000000000000515BI010000129930Each
189189Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes \n& fittings conforming to IS-15778: 2007 Ball Valve40mmBI01010001010000000000000515BI010000130030Each
190190Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes \n& fittings conforming to IS-15778: 2007 Ball Valve32mmBI01010001010000000000000515BI010000130130Each
191191Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes \n& fittings conforming to IS-15778: 2007 Ball Valve25 mmBI01010001010000000000000515BI010000130230Each
192192Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes \n& fittings conforming to IS-15778: 2007 Ball Valve20 mmBI01010001010000000000000515BI010000130330Each
193193Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. Hindware/Parryware/Cera, made (a) With 'P' trap (With Vent)BI01010001010000000000000515BI010000130430Each
194194Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing). (i) 580 mm X 440 mmBI01010001010000000000000515BI010000130570Each
195195Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(a) With 'P' trapBI01010001010000000000000515BI010000130620Each
196196Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete.\n(b) Anglo Indian (ii) Plastic (hallow type) whiteBI01010001010000000000000515BI010000130750Each
197197Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.BI01010001010000000000000515BI0100001308120Each
198198Supplying, fitting and fixing Squating plate with integral flushing in white\nvitreous chinaware of approved make in cement concrete (6:3:1) with\njhama chips complete. (Payment of concrete will be paid seperately).\n(i) 450 mm X 350 mmBI01010001010000000000000515BI0100001309120Each
199199Supplying, fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with coupling at one end fitted with necessary clamps. 1050 mm longBI01010001010000000000000515BI0100001310150Each
200200Supplying, fitting and fixing vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 32 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm sizeBI01010001010000000000000515BI010000131150Each
201201Supplying, fitting and fixing pedestal of approved make for wash basin (white)BI01010001010000000000000515BI010000131250Each
202202Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass 25 mm dia. and 600 mm longBI01010001010000000000000515BI0100001313120Each
203203Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mmBI01010001010000000000000515BI010000131480Each
204204Supplying, fitting and fixing glass shelf with aluminium guard rails.\n(a) Ordinary type with 5.5 mm sheet glass (ii) 600 mm X 125 mmBI01010001010000000000000515BI010000131580Each
205205Supplying ,fitting and fixing bib cock or stop cock.(e) PTMT (Polytetra methylene terephthalate)StopCock (Prayag or Equivalent) 15 mmBI01010001010000000000000515BI0100001316100Each
206206PTMT Pillar Cock - 15 mm. (Prayag or equivalent)BI01010001010000000000000515BI0100001317100Each
207207(a) (i) Chromium plated Bib Cock long body with wall flange with aerator\n(Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of\nESSCO or similar brand)BI01010001010000000000000515BI010000131830Each
208208(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar).BI01010001010000000000000515BI010000131930Each
209209CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model -\nTropical / Sumthing Special of ESSCO or similar brand).BI01010001010000000000000515BI010000132030Each
210210(ii) Chromium plated Concealed Stop Cock (Equivalent to Code No. 514(A) & Model - Tropical / Sumthing Special of ESSCO or similar\nbrand).BI01010001010000000000000515BI010000132130Each
211211CP 2-way bib Cock - 15 mm, supplied, fitted and fixed. (Code\nNo.5041 & Model - FLORENTINE of JAQUAR or similar brand)BI01010001010000000000000515BI010000132230Each
212212g) CP Sink Cock with Regular Swinging Spout (Table Mounted Model)\n(Equivalent to Code No. 5357 of JAQUAR or similar brand).BI01010001010000000000000515BI010000132310Each
213213Supplying, fitting and fixing shower of approved brand and make.(a) (i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand).BI01010001010000000000000515BI010000132420Each
214214Chromium plated shower arm 240 mm long (Equivalent to Code No.\n536(A) & Model - Tropical / Sumthing Special of ESSCO or similar\nbrand).BI01010001010000000000000515BI010000132520Each
215215Chromium plated Hand shower 70mm dia Round Shape Single flow\nwith Flexible Tube & fittings(Equivalent to Code No. ESH-5512 & Model -\nTropical / Sumthing Special of ESSCO or similar).BI01010001010000000000000515BI010000132620Each
216216Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall\nHook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or\nsimilar).BI01010001010000000000000515BI010000132720Each
217217Supplying, fitting and fixing shower of approved brand and make\nc) PTMT overhead shower (Prayag or equivalent)\n(i) 150 mm roundBI01010001010000000000000515BI010000132850Each
218218Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(i) Door Tee (110 mm)BI01010001010000000000000515BI0100001329100Each
219219Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(i)Plain Tee (110 mm)BI01010001010000000000000515BI0100001330100Each
220220Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(i)Plain Tee (160 mm)BI01010001010000000000000515BI0100001331100Each
221221Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(ii)Bend 87.5 dig.(110 MM)BI01010001010000000000000515BI0100001332100Each
222222Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(ii)Bend 87.5 dig.(160 MM)BI01010001010000000000000515BI0100001333100Each
223223Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(iii) Door Bend (T.S)110 mmBI01010001010000000000000515BI0100001334100Each
224224Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(iii) Door Bend (T.S)160 mmBI01010001010000000000000515BI0100001335100Each
225225Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(iv) Vent Cowl 110 mmBI01010001010000000000000515BI0100001336150Each
226226Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) FittingsPipe Clip 110 mmBI01010001010000000000000515BI01000013371000Each
227227Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) FittingsPipe Clip 160 mmBI01010001010000000000000515BI0100001338500Each
228228Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) FittingsDouble Y (110 mm)BI01010001010000000000000515BI010000133950Each
229229Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) FittingsPlain Y(110 mm)BI01010001010000000000000515BI010000134050Each
230230Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) FittingsPlain Y(160 mm)BI01010001010000000000000515BI010000134150Each
231231Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(i)Door Tee (160 mm)BI01010001010000000000000515BI0100001342100Each
232232Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(ii)Bend 45 dig.(110 MM)BI01010001010000000000000515BI0100001343100Each
233233Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(ii)Bend 45 dig.(160 MM)BI01010001010000000000000515BI0100001344100Each
234234Labour for fitting and fixing U.P.V.C pipes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials) (A) Above ground (i) 110 mmBI01010001010000000000000515BI0100001345200Mtr
235235Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials) (A) Above ground(i) 160 mmBI01010001010000000000000515BI0100001346200Mtr
236236Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials) (A) Under ground (i) 110 mmBI01010001010000000000000515BI0100001347300Mtr
237237Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials) (A) Under ground(i) 160 mmBI01010001010000000000000515BI0100001348300Mtr
238238Supplying, fitting and fixing C.I. round grating.(ii) 100 mmBI01010001010000000000000515BI0100001349100Each
239239Supplying, fitting and fixing C.I. round grating.(ii) 150 mmBI01010001010000000000000515BI0100001350100Each
240240Supplying, fitting and fixing C.I. square jalli.(ii) 100 mmBI01010001010000000000000515BI0100001351100Each
241241Supplying, fitting and fixing C.I. square jalli.(ii) 150 mmBI01010001010000000000000515BI0100001352100Each
242242Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (c) 2000 litre capacityBI01010001010000000000000515BI010000135320Each
243243Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity.\n(a) Upto 1st story from G.L.BI01010001010000000000000515BI010000135410Each
244244Labour for hoisting plastic water storage tank. (ii) Above 1500 litre upto 5000 litre capacity.\n(a) Upto 2nd story from G.L.BI01010001010000000000000515BI010000135510Each
245245Labour for punching hole in plastic water storage tank upto 50 mm dia.BI01010001010000000000000515BI0100001356100Each
246246Supplying fitting fixing PTMT smart shelf of approved make of size 300 mmBI01010001010000000000000515BI0100001357100Each
247247Suppling fitting fixing soap holder a)PTMT (Prayag or Equivelent)BI01010001010000000000000515BI0100001358100Each
248248Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets.(i) 530 mm X 430 mm x 180 mmBI01010001010000000000000515BI01000013595Each
249249Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.(i) 590 mm X 390 mm X 380 mmBI01010001010000000000000515BI010000136010Each
250250Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.\ni) With Pakur variety. (SAIL/TATA/RINL)BI01010001010000000000000515BI010000136160Each
2512515 MT load bearing capacity gully pit cover with frame and hinge arrangement for opening of size Cover: 470 mm X 420 mm X 80 mm Frame: 590 mm X 550 mm X 170 mm opening: 380mm x 305mm\nWeight: 100 kg (approx)BI01010001010000000000000515BI010000136260Each
252252Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. \nPakur varity. (SAIL/TATA/RINL) For 10 usersBI01010001010000000000000515BI01000013635Each
253253Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. \nPakur varity. (SAIL/TATA/RINL) For 20 usersBI01010001010000000000000515BI01000013645Each
254254Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. \nPakur varity. (SAIL/TATA/RINL) For 30 usersBI01010001010000000000000515BI01000013655Each
255255Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. \nPakur varity. (SAIL/TATA/RINL) For 50 usersBI01010001010000000000000515BI01000013665Each
256256Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. \nPakur varity. (SAIL/TATA/RINL) For 100 usersBI01010001010000000000000515BI01000013672Each
257257Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. \nPakur varity. (SAIL/TATA/RINL) For 200 usersBI01010001010000000000000515BI01000013681Each
258258Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (6:1) and 1.00m inside dia. (SAIL/TATA/RINL)BI01010001010000000000000515BI010000136920Each
259259Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. 900 mm longBI01010001010000000000000515BI0100001370120Each
260260Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by Rig boring system (either by reverse circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete.\n(a) For depth upto 250 metre for 100 mm dia. tube well with top enlargement of 200 mm dia.\n(i) First 50 mtr (For 4nos Boring)\nBI01010001010000000000000515BI0100001371200Mtr
261261Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by Rig boring system (either by reverse circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete.\n(a) For depth upto 250 metre for 100 mm dia. tube well with top enlargement of 200 mm dia.ii) Next 50 mtr (For 4nos Boring)\nBI01010001010000000000000515BI0100001372200Mtr
262262Supplying, fitting and fixing PVC pipes for underground work of approved make (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo,nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specialsa) PVC Pipes. 200 mm dia. \n(a) For Exposed Work\nPVC Pipes\nBI01010001010000000000000515BI0100001373140mtr
263263Supplying, fitting and fixing PVC pipes for underground work of approved make (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo,nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specialsa) PVC Pipes.b) 100 mm dia. \n(a) For Exposed Work\nPVC Pipes\nBI01010001010000000000000515BI0100001374180mtr
264264Supplying high density polythene strainer of approved make with adapter confirming to I.S. specification.\n(iv) 100 mm dia\n \n\nBI01010001010000000000000515BI010000137560mtr
265265Surging of existing tube well with chemical treatment and bucket wash (prior to use of compressor machine) and developing the tube well with compressor machine at least 3 (three) days at 8 (eight) hours per day till the yield is obtained at least by 75% of the total specified yield of the tube well (measured by 'V' notch tank) and draw down is within the permissible limit of 10% variation and water so obtained after such washing and developing will be free from sand and bacteria for which test report from the Public Analyst is to be obtained. (The rate is inclusive of all labour and materials including hire charges of tools and plants and cost of materials.)(b) For tube well of size bigger than 100mm dia. with top enlargement to have yield of 6000 gallons per hourBI01010001010000000000000515BI01000013764Each
266266Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.BI01010001010000000000000515BI01000013774L.S
267267Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.BI01010001010000000000000515BI01000013784L.S
268268Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-in-charge including cost of all materials labour and equipment complete.\nNote: Initial 6 m. of Annular space between the housing pipe and the bore should not be shrouded with Pea size gravel to avoid contamination with surface water.\nBI01010001010000000000000515BI010000137910Cum
269269Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete.\nBI01010001010000000000000515BI010000138010Cum
270270Supplying, fitting and fixing PVC pipes of approved make of Schedule 80\n(medium duty) conforming to ASTMD - 1785 and threaded to match with\nGI Pipes as per IS : 1239 (Part - I). with all necessary accessories,\nspecials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,\nreducing socket, reducing tee, short piece etc. fitted with holder bats\nclamps, including cutting pipes, making threads,fitting, fixing etc.\ncomplete in all respect including cost of all necessary fittings as\nrequired,jointing materials and two coats of painting with approved paint\nin any position above ground. (Payment will be made on the centre line\nmeasurements of total pipe line including all specials. No separate\npayment will be made for accesories, specials. Payment for painting will\nbe made seperately)\n(a) For Exposed Work\nPVC Pipes 80 mmBI01010001010000000000000515BI0100001381500Mtr
271271Supplying, fitting and fixing PVC pipes of approved make of Schedule 80\n(medium duty) conforming to ASTMD - 1785 and threaded to match with\nGI Pipes as per IS : 1239 (Part - I). with all necessary accessories,\nspecials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,\nreducing socket, reducing tee, short piece etc. fitted with holder bats\nclamps, including cutting pipes, making threads,fitting, fixing etc.\ncomplete in all respect including cost of all necessary fittings as\nrequired,jointing materials and two coats of painting with approved paint\nin any position above ground. (Payment will be made on the centre line\nmeasurements of total pipe line including all specials. No separate\npayment will be made for accesories, specials. Payment for painting will\nbe made seperately)\n(a) For Exposed Work\nPVC Pipes 50mm dia.BI01010001010000000000000515BI0100001382500Mtr
272272Supplying, fitting and fixing Peet's valve fullway gunmetal standard\npattern best quality of approved brand bearing I.S.I. marking with\nfittings (tested to 21 kg per sq. cm.). 50 mm diaBI01010001010000000000000515BI010000138320each
273273Supply & fixing 80 mm dia G.I. Union\nBI01010001010000000000000515BI010000138420each
274274Supply & fixing 80 mm dia G.I. Flange\n(A) PVC Pipes\nBI01010001010000000000000515BI010000138520pair
275275a) 75 mm x 150 mm M.S. heavy type belmouth reducing socket.BI01010001010000000000000515BI010000138620Each
276276Supply & fixing 65 mm x 50 mm dia G.I. Reducing Tee (For header)BI01010001010000000000000515BI010000138720each
277277Supply & fixing 100mm dia G.I. nipple short piece 150mm long\n(A) PVC PipesBI01010001010000000000000515BI010000138820each
278278Supply & fixing 80mm dia G.I. plugBI01010001010000000000000515BI010000138920each
279279Supply & fixing 65 mm x 50 mm dia Reducing socket (For delivery Line from header) \n(A) PVC PipesBI01010001010000000000000515BI010000139020each
280280Supplying, fitting and fixing heavy type bell mouth reducing socket.a) 100 mm x 200 mmBI01010001010000000000000515BI010000139120Each
281281Supply of PVC pipes & fittings (medium duty) conforming to ASTMD-1785 and threded to match with GI pipes as per IS:1239(Part-I) \nThreded End Cap\n200 mmBI01010001010000000000000515BI010000139220Each
282282\nc) 100 mm dia end plug\n \nBI01010001010000000000000515BI010000139320Each
283283d) Supplying, fitting and fixing 300 mm M.S. housing clamp of approved qualityBI01010001010000000000000515BI010000139420Per Set
284284Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report.BI01010001010000000000000515BI01000013954Each Test
285285Elbow 80mmBI01010001010000000000000515BI010000139660each
286286Elbow 50mmBI01010001010000000000000515BI010000139760each
287287C.I. sluice valve with flanged ends drilled to as per I.S. 1358/62 and\nhaving all cast iron components as per I.S. 780/71 solid forged bronze\ninside screw spindle having ultimate tensile strength not less than 4.72 MT\nper sq. cm. Spindle nut valve and seat faces of hard wear resisting,\nmanufactured from best quality gunmetal conforming to I.S. 780/71,\npainted black all over with asphalt base paint tested to 21 kg (hydraulic\npressure) per sq. cm., valve opening to anticlockwise direction, fitted and\nfixed complete. 50 mmBI01010001010000000000000515BI01000013984each
288288Providing 200 mm centre guide.\ni) With ClampBI01010001010000000000000515BI010000139920per set
289289ELECTRICAL WORKS(Schedule Items) :\nSupply & fixing 415V 315A capacity MS (16SWG) Busbar Chamber having dimension of (500x150 mm) to be fixed on iron frame on wall consisting of 4 nos Cu bars of size (4x40x5mm). The same BBC should have a separate cubicle at one end consisting 3 nos 315A capacity porcelain cut out fuse unit & one nutral bar to receive the service cable including connecting the cut out fuse units with the BBC by S/F PVC insulated copper wire duly socketed at both ends incl. earthing attachment & painting\n(Pwd page-D13 Item no. 19(b))BI01010001010000000000000515BI01000014006mtr
290290Supply & fixing 415V 200A capacity MS (16SWG) Busbar Chamber having dimension of (500x150 mm) to be fixed on iron frame on wall consisting of 4 nos Cu bars of size (4x20x5mm). The same BBC should have a separate cubicle at one end consisting 3 nos 250A capacity porcelain cut out fuse unit & one nutral bar to receive the service cable including connecting the cut out fuse units with the BBC by S/F4 PVC insulated copper wire duly socketed at both ends incl. earthing attachment & painting\n(Pwd page-D13 Item no. 19(b))BI01010001010000000000000515BI01000014012mtr
291291Supply & fixing 415V 125A capacity MS (16SWG) Busbar Chamber having dimension of (500x150 mm) to be fixed on iron frame on wall consisting of 4 nos Cu bars of size (4x15x3mm). The same BBC should have a separate cubicle at one end consisting 3 nos 125A capacity porcelain cut out fuse unit & one nutral bar to receive the service cable including connecting the cut out fuse units with the BBC by S/F4 x 35 sqmm PVC insulated copper wire duly socketed at both ends incl. earthing attachment & painting\n(Pwd page-D13 Item no. 19(b))BI01010001010000000000000515BI01000014024mtr
292292Supply & Fixing 415V 160A TPN switch (Make L&T/Siemens) in suitable SS enclosure with HRC fuses on LS & NL on angle iron frame on wall with Nuts and Bolts etc.incl. S&F 3 Nos DIN type HRC Fuse & earthing attachment.\n[PWD SOR :-Page No-D-3,(Item No-4(a)]BI01010001010000000000000515BI01000014033Nos
293293Supply & Fixing 415V 125A TPN switch (Make L&T/Siemens) in suitable SS enclosure with HRC fuses on LS & NL on angle iron frame on wall with Nuts and Bolts etc.incl. S&F 3 Nos DIN type HRC Fuse & earthing attachment.\n[PWD SOR :-Page No-D-3,(Item No-4(a)]BI01010001010000000000000515BI01000014042Nos
294294Supply & Fixing 415V 100A TPN switch (Make L&T/Siemens) in suitable SS enclosure with HRC fuses on LS & NL on angle iron frame on wall with Nuts and Bolts etc.incl. S&F 3 Nos DIN type HRC Fuse & earthing attachment.\n[PWD SOR :-Page No-D-3,(Item No-4(a)]BI01010001010000000000000515BI01000014052Nos
295295Supply & Fixing 415V 63A TPN switch (Make L&T/Siemens) in suitable SS enclosure with HRC fuses on LS & NL on angle iron frame on wall incl. earthing attachment. \n[PWD SOR :-Page No-D-3,(Item No-4(a)]BI01010001010000000000000515BI01000014062Nos
296296Supply & Fixing 415V 160 A Four pole on load change over switch in suitable SS enclosure (Make L&T) on angle iron frame on wall incl. earthing attachment. [PWD SOR :-Page No-D-2,(Item No-3(a)]BI01010001010000000000000515BI01000014075Nos
297297Supply & Fixing 415V 125A Four pole on load change over switch in suitable SS enclosure (Make L&T) on angle iron frame on wall incl. earthing attachment.\n[PWD SOR :-Page No-D-2,(Item No-3(a)]BI01010001010000000000000515BI01000014085Nos
298298Supply & Fixing 415V 63A Four pole on load change over switch in suitable SS enclosure (Make HPL/Standard/Havells) on angle iron frame on wall incl. earthing attachment.\n[PWD SOR :-Page No-D-2,(Item No-3(a)]BI01010001010000000000000515BI01000014093Nos
299299Supply & Fixing 240V 32 A DP MCB enclouser with 1 No 32A DP MCB C series concealed in wall incl. earthing attachment &\npainting . (Legrand)\nPWD SOR :-Page No-D-6,(Item No-7)Page No-D-9(Item No-11)BI01010001010000000000000515BI010000141020Nos
300300Supply & fixing double door 4 way Vertical TPNMCBDB (Legrand) with IP 42/43 protection SS enclosure on angle iron frame on wall & mending good the damages to original finish incl. Interconnection with suitable size of copper wire & nuetral link & provision of earthing attachment comprising of the following accessories (All make Legrand):\na) 125 A four pole MCCB of breaking capacity 25KA/ 35KA \n with adjustable thermal & fixed magnetic setting --- 1 no\nb) 63 A TP MCB ---1 n\nc) 32A SP MCB -- 9 nos\n\nPWD SOR :-Page No-D-8(Item No-10)Page No-D-6,(Item No-7)Page No-D-11(Item No-15)BI01010001010000000000000515BI01000014111set
301301Supply & fixing double door 4 way Vertical TPNMCBDB (Legrand) with IP 42/43 protection SS enclosure on angle iron frame on wall & mending good the damages to original finish incl. Interconnection with suitable size of copper wire & nuetral link & provision of earthing attachment comprising of the following accessories (All make Legrand):\na) 200 A four pole MCCB of breaking capacity 25KA/ 35KA \n with adjustable thermal & fixed magnetic setting --- 1 no\nb) 63 A TP MCB ---1 n\nc) 32A SP MCB -- 9 nos\nPWD SOR :-Page No-D-8(Item No-10)Page No-D-6,(Item No-7)Page No-D-11(Item No-15)BI01010001010000000000000515BI01000014121set
302302Supply & fixing 4 way double door Horizontal TPNMCBDB (legrand) concealed in wall incl inter connection with suitable copper wire, neutral link & earthing attachment comprising of the followings (All Legrand/Siermens)\na) 63A four pole MCB isolater --- 1 no\nb) 32A SP MCB --- 12 nos\nPWD SOR :-Page No-D-5(Item No-6)Page No-D-6,(Item No-7)Page No-D-10(Item No-14)\nBI01010001010000000000000515BI010000141316set
303303Supply & Fixing (2+12) way SPN MCBDB (Legrand/Seimens) with IP-42/43 protection Concealed in wall & mending good the damages to original finish incl. Interconnection with suitable copper wire & nuetral link incl. earthing attachment comprising with the following:\na) 32A DP MCB isolator --- 1 no\nb) 6 to 32A SP MCB -- 12 nos\nPWD SOR :-Page No-D-5(Item No-6)Page No-D-6,(Item No-7)Page No-D-9(Item No-13)BI01010001010000000000000515BI01000014146set
304304Supply & Fixing (2+8) way SPN MCBDB (Legrand/Seimens) with IP-42/43 protection Concealed in wall & mending good the damages to original finish incl. Interconnection with suitable copper wire & nuetral link incl. earthing attachment comprising with the following:\na) 32A DP MCB isolator --- 1 no\nb) 6 to 16A SP MCB -- 8 nos\nPWD SOR :-Page No-D-5(Item No-6)Page No-D-6,(Item No-7)Page No-D-9(Item No-13)BI01010001010000000000000515BI010000141513set
305305Supply & Fixing (2+6) way SPN MCBDB (Legrand/Havells) with IP-42/43 protection Concealed in wall & mending good the damages to original finish incl. Interconnection with suitable copper wire & nuetral link incl. earthing attachment comprising with the following:\na) 40A DP MCB isolator --- 1 no\nb) 6 to 16A SP MCB -- 6 nos\nPWD SOR :-Page No-D-6(Item No-6)Page No-D-6,(Item No-7)Page No-D-10(Item No-13)BI01010001010000000000000515BI01000014166set
306306Supply & Fixing (2+4) way SPN MCBDB (Legrand/Seimens) with IP-42/43 protection Concealed in wall & mending good the damages to original finish incl. Interconnection with suitable copper wire & nuetral link incl. earthing attachment comprising with the following:\na) 32A DP MCB isolator --- 1 no\nb) 6 to 16A SP MCB -- 4nos\nPWD SOR :-Page No-D-5(Item No-6)Page No-D-6,(Item No-7)Page No-D-9(Item No-13)BI01010001010000000000000515BI01000014172set
307307Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed\nPWD SOR :-Page No-F-2(Item No-1(a)&1(b)\na) 3.5 x 95 sq mmBI01010001010000000000000515BI0100001418395mtr
308308Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed\nPWD SOR :-Page No-F-2(Item No-1(a)&1(b)\nb) 3.5 x 70 sq mmBI01010001010000000000000515BI0100001419375mtr
309309Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed\nPWD SOR :-Page No-F-2(Item No-1(a)&1(b)\nc)3.5 x 50 sq mmBI01010001010000000000000515BI0100001420125mtr
310310Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed\nPWD SOR :-Page No-F-2(Item No-1(a)&1(b)\nd) 3.5 x 35 sq mmBI01010001010000000000000515BI0100001421625mtr
311311Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed\nPWD SOR :-Page No-F-2(Item No-1(a)&1(b)\ne) 3.5 x 25 sq mmBI01010001010000000000000515BI0100001422345mtr
312312Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed\nPWD SOR :-Page No-F-2(Item No-1(a)&1(b)\nf) 4 x 16 sq mmBI01010001010000000000000515BI0100001423475mtr
313313Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed\nPWD SOR :-Page No-F-2(Item No-1(a)&1(b)\ng) 2 x 10 sq mmBI01010001010000000000000515BI0100001424100mtr
314314Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed\nPWD SOR :-Page No-F-2(Item No-1(a)&1(b)\nh) 2 x 6 sq mmBI01010001010000000000000515BI0100001425700mtr
315315Laying of cable above 3½ core 90 sqmm and upto 3½ core 150\nsqmm on wall/surface including S & F MS clams with earthing\nattachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as\nnecy., mending good damages and painting\nPWD SOR :-Page No-F-1(Item No-2(e)BI01010001010000000000000515BI010000142645mtr
316316Laying of cable above 3½ core 50 sqmm and upto 3½ core 90\nsqmm on wall/surface including S & F MS clams with earthing\nattachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as\nnecy., mending good damages and painting\nPWD SOR :-Page No-F-1(Item No-2(d)BI01010001010000000000000515BI010000142725mtr
317317Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on\nwall/surface incl. S & F MS saddles with earthing attachment in 2\nx 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending\ngood damages and painting\nPWD SOR :-Page No-F-1(Item No-2(c)BI01010001010000000000000515BI010000142850mtr
318318Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F\nMS saddles with earthing attachment in 10 SWG GI (Hot Dip)\nWire, making holes etc. as necy. mending good damages and\npainting\nPWD SOR :-Page No-F-1(Item No-2(b)BI01010001010000000000000515BI010000142970mtr
319319Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F\nMS saddles with earthing attachment in 10 SWG GI (Hot Dip)\nWire, making holes etc. as necy. mending good damages and\npainting\nPWD SOR :-Page No-F-1(Item No-2(a)BI01010001010000000000000515BI0100001430170mtr
320320Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable &Finishing the end of following XLPE/PVC armoured cables by\ncrimping method incl. supplying and fixing solderless socket\n(Dowels make), tapes, anticorrosive paste & jointing materials:\nPWD SOR :-Page No-F-4&F-5(Item No-7&8(b)\nd) 3.5 x 95 sq mmBI01010001010000000000000515BI01000014318set
321321Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable &Finishing the end of following XLPE/PVC armoured cables by\ncrimping method incl. supplying and fixing solderless socket\n(Dowels make), tapes, anticorrosive paste & jointing materials:\nPWD SOR :-Page No-F-4&F-5(Item No-7&8(b)\nd) 3.5 x 70 sq mmBI01010001010000000000000515BI01000014324set
322322Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable &Finishing the end of following XLPE/PVC armoured cables by\ncrimping method incl. supplying and fixing solderless socket\n(Dowels make), tapes, anticorrosive paste & jointing materials:\nPWD SOR :-Page No-F-4&F-5(Item No-7&8(b)\ne)3.5 x 50 sq mmBI01010001010000000000000515BI01000014336set
323323Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable &Finishing the end of following XLPE/PVC armoured cables by\ncrimping method incl. supplying and fixing solderless socket\n(Dowels make), tapes, anticorrosive paste & jointing materials:\nPWD SOR :-Page No-F-4&F-5(Item No-7&8(b)\nf) 3.5 x 35 sq mmBI01010001010000000000000515BI01000014348set
324324Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable &Finishing the end of following XLPE/PVC armoured cables by\ncrimping method incl. supplying and fixing solderless socket\n(Dowels make), tapes, anticorrosive paste & jointing materials:\nPWD SOR :-Page No-F-4&F-5(Item No-7&8(b)\ng) 3.5 x 25 sq mmBI01010001010000000000000515BI010000143516set
325325Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable &Finishing the end of following XLPE/PVC armoured cables by\ncrimping method incl. supplying and fixing solderless socket\n(Dowels make), tapes, anticorrosive paste & jointing materials:\nPWD SOR :-Page No-F-4&F-5(Item No-7&8(b)\nh) 4 x 16 sq mmBI01010001010000000000000515BI010000143610set
326326Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable &Finishing the end of following XLPE/PVC armoured cables by\ncrimping method incl. supplying and fixing solderless socket\n(Dowels make), tapes, anticorrosive paste & jointing materials:\nPWD SOR :-Page No-F-4&F-5(Item No-7&8(b)\nh) 2 x 10 sq mmBI01010001010000000000000515BI01000014376set
327327Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable &Finishing the end of following XLPE/PVC armoured cables by\ncrimping method incl. supplying and fixing solderless socket\n(Dowels make), tapes, anticorrosive paste & jointing materials:\nPWD SOR :-Page No-F-4&F-5(Item No-7&8(b)\nk) 2 x 6 sq mmBI01010001010000000000000515BI010000143830set
328328Supply & laying medium gauge G.I. Pipe (ISI-Medium) for cable protection with pole clamp.\nPWD SOR :-Page No-F-6(Item No-11(a,c,d & f,g)\na) 100 mm diaBI01010001010000000000000515BI01000014395mtr
329329Supply & laying medium gauge G.I. Pipe (ISI-Medium) for cable protection with pole clamp.\nPWD SOR :-Page No-F-6(Item No-11(a,c,d & f,g)\nb) 80 mm diaBI01010001010000000000000515BI010000144011mtr
330330Supply & laying medium gauge G.I. Pipe (ISI-Medium) for cable protection with pole clamp.\nPWD SOR :-Page No-F-6(Item No-11(a,c,d & f,g)\nc) 50 mm diaBI01010001010000000000000515BI010000144112mtr
331331Supply & laying medium gauge G.I. Pipe (ISI-Medium) for cable protection with pole clamp.\nPWD SOR :-Page No-F-6(Item No-11(a,c,d & f,g)\nd) 40 mm diaBI01010001010000000000000515BI010000144220mtr
332332Supply & laying medium gauge G.I. Pipe (ISI-Medium) for cable protection with pole clamp.\nPWD SOR :-Page No-F-6(Item No-11(a,c,d & f,g)\ne)25mm diaBI01010001010000000000000515BI0100001443120mtr
333333Supplying and fixing polythene pipe complete with fittings as\nnecy. under ceiling/beam, bound with 22 SWG GI binding wire\nincl. supplying and drawing 1x18 SWG GI Wire as fish wire\ninside the pipes and fittings and providing 50 mm dia disc of\nMS sheet (20 SWG) having colour paint at one face fastened\nat the load point end of the polythene pipe with fish wire\n(synchronizing with roof/beam casting work of building\nconstruction)\n19mm dia 3mm thick Polythene Pipe\nPWD SOR :-Page No-E-2(Item No-1(b)BI01010001010000000000000515BI0100001444800RM
334334Cutting Channel of size (40 mm x 40 mm) on masonry wall by\nElectric operated cutting machine incl. supplying & fixing\nheavy gauge 19 mm, 3 mm thick Polythene pipe by means of\nanchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG\nincl. supplying and drawing 18 SWG GI wire as Fish wire and\nmending good damages to original finish by using own tools\nand tackles\n19 mm dia 3 mm thick polythene pipe without earth\ncontinuity wire\nPWD SOR :-Page No-E-3(Item No-6(a)BI01010001010000000000000515BI01000014456150RM
335335Cutting Channel of size (43 mm x 43 mm) on masonry wall by\nElectric operated cutting machine incl. supplying & fixing\nheavy gauge 25 mm, 3 mm thick Polythene pipe by means of\nanchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG\nincl. supplying and drawing 18 SWG GI wire as Fish wire and\nmending good damages to original finish by using own tools\nand tackles\n25 mm dia 3 mm thick polythene pipe without earth\ncontinuity wire\nPWD SOR :-Page No-E-3(Item No-7(a)BI01010001010000000000000515BI01000014461195RM
336336Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Phinolex/Havells/ Kei/ Mescab) of the following sizes through suitable alkathene pipe recessed in wall \nPWD SOR :-Page No E-9(Item No-1)\na) 4 x 16 sqmm + 2 x 10 sq mm (VTPN DB to TPNDB all floors)BI01010001010000000000000515BI0100001447120mtr
337337Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Phinolex/Havells/ Kei/ Mescab) of the following sizes through suitable alkathene pipe recessed in wall \nPWD SOR :-Page No E-9(Item No-1)\nb) 4 x 10 sqmm + 2 x 6 sq mmBI01010001010000000000000515BI010000144870mtr
338338Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Phinolex/Havells/ Kei/ Mescab) of the following sizes through suitable alkathene pipe recessed in wall \nPWD SOR :-Page No E-9(Item No-1)\nb) 4 x 6 sqmm + 2 x 4sq mmBI01010001010000000000000515BI010000144970mtr
339339Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Phinolex/Havells/ Kei/ Mescab) of the following sizes through suitable alkathene pipe recessed in wall \nPWD SOR :-Page No E-9(Item No-1)\nb) 4 x 2.5sqmm + 2 x 1.5 sq mmBI01010001010000000000000515BI0100001450180mtr
340340Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Phinolex/Havells/ Kei/ Mescab) of the following sizes through suitable alkathene pipe recessed in wall \nPWD SOR :-Page No E-9(Item No-1)\nc) 2 x 6 + 1 x 4 sq mmBI01010001010000000000000515BI0100001451600mtr
341341Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Phinolex/Havells/ Kei/ Mescab) of the following sizes through suitable alkathene pipe recessed in wall \nPWD SOR :-Page No E-9(Item No-1)\nd) 2 x 4 + 1 x 2.5 sq mmBI01010001010000000000000515BI01000014521200mtr
342342Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Phinolex/Havells/ Kei/ Mescab) of the following sizes through suitable alkathene pipe recessed in wall \nPWD SOR :-Page No E-9(Item No-1)\ne) 2 x 2.5 + 1 x 1.5 sq mmBI01010001010000000000000515BI01000014532500mtr
343343Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Phinolex/Havells/ Kei/ Mescab) of the following sizes through suitable alkathene pipe recessed in wall \nPWD SOR :-Page No E-9(Item No-1)\nf)4x16 sq.mm + 2x10 sq.mm (panel to TPNDB)BI01010001010000000000000515BI010000145435mtr
344344Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Phinolex/Havells/ Kei/ Mescab) of the following sizes through suitable alkathene pipe recessed in wall \nPWD SOR :-Page No E-9(Item No-1)\ng) 3 x 1.5 sq mmBI01010001010000000000000515BI01000014553370mtr
345345Distn. wiring in 3 x 1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Finolex/ Gloster/ Havells /Mescab/KEI) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Legrand/ Crabtree/ North west/Philips) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending gooddamages\nAvg Run 7 Mtr\nPWD SOR :-Page No-E-20(Item No-1(ii)BI01010001010000000000000515BI0100001456250pts
346346Distn. wiring in 3 x 1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Finolex/ Gloster/ Havells /Mescab/KEI) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Legrand/ Crabtree/ North west/Philips) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending gooddamages\nAvg Run 8 Mtr\nPWD SOR :-Page No-E-20(Item No-1(iii)BI01010001010000000000000515BI0100001457650pts
347347Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Gloster /Havells/ Mescab/KEI) in 19mm bore, 3mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pin Modular type plug socket & modular type switch (Crabtree) incl. S&F earth continuity wire fixed on 4 module GI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. \na) on board \nPWD SOR :-Page No-E-20(Item No-3(i)BI01010001010000000000000515BI0100001458125pts
348348Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Gloster /Havells/ Mescab/KEI) in 19mm bore, 3mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pin Modular type plug socket & modular type switch (Crabtree) incl. S&F earth continuity wire fixed on 4 module GI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. \n \n\nb) Average run 4.5 mtr\nPWD SOR :-Page No-E-20(Item No-3(iv)BI01010001010000000000000515BI010000145940pts
349349Supply & fixing of Modular type computer plug board of 8 module GI box with cover plate recessed in wall comprising of the following(All cabtree):\na) 6/16A socket & 16A switch ---1 set \nb) 6A socket - 2 nos & 16A switch - 1 no --- 1 set\nPWD SOR :-Page No-E-17(Item No-1(c),3(b),4(a)&4(b)BI01010001010000000000000515BI010000146060sets
350350Supply & Fixing 240 V, 16 A, 3 pin Modular type Power plug socket (Crabtree/Legrand) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover \nplate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu and earth continuity wire\nPWD SOR :-Page No-E-18 Item No-9(b)BI01010001010000000000000515BI010000146125each
351351Supply & fixing of 16A Modular type Switch of 2 module GI box with cover plate recessed in wall \nPWD SOR :-Page No-E-17 Item No-2(a)&3(b)BI01010001010000000000000515BI010000146212each
352352Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall & making necy. connections with PVC Cu wire and earth wire (AC)PWD SOR :-Page No-E-17 Item No-5(a)BI01010001010000000000000515BI010000146328each
353353Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Cabtree) & necy. Connections. (AC)\nPWD SOR :-Page No-E-17 Item No-5(b)BI01010001010000000000000515BI010000146428each
354354Distn. wiring in 3x1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Gloater/ Fionolex/ havells /KEI/Mescab) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/ perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.\nAvg Run 9 Mtr\nPWD SOR :-Page No-E-9 Item No-2(a-iv)\nBI01010001010000000000000515BI0100001465432Pt
355355Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Gloater/Fionolex/havells /KEI/Mescab) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch boardwith bakelite/perspex (wall matching colour) top cover (3 mm thick)flushed in wall incl. mending good damages to original finish\na) on board \nPWD SOR :-Page No-E-10 Item No-4(a-i)BI01010001010000000000000515BI010000146681pts
356356Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Gloater/Fionolex/havells /KEI/Mescab) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch boardwith bakelite/perspex (wall matching colour) top cover (3 mm thick)flushed in wall incl. mending good damages to original finish\n b) Ave run 4.5 mtr \nPWD SOR :-Page No-E-10 Item No-4(a-iv)BI01010001010000000000000515BI010000146760pts
357357Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Anchor) on sheet metal switch board embedded in wall incl. S/F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necy connections (Computer)\nPWD SOR :-Page No-E-7 Item No-25BI01010001010000000000000515BI010000146820each
358358Supply & Fixing 240 V, 20A, Power plug socket with separate 20 A Piano key type switch (Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board & bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required\nPWD SOR :-Page No-E-6 Item No-22BI01010001010000000000000515BI010000146928each
359359Supply & Fixing 240 V, 20 A Piano key type Control switch (Anchor) on sheet metal switch board incl. S & F 100x100x65mm MS\n(16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required\nPWD SOR :-Page No-E-6 Item No-17(b)BI01010001010000000000000515BI010000147015each
360360Fixing only single/twin LED Tube light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG supports fixed with “L” type MS clamp whose one side fixed onceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length\nPWD SOR :-Page No-C-2 Item No-15BI01010001010000000000000515BI0100001471660each
361361Fixing only Single/Twin LED Tube light fitting complete with all accessories directly on wall/ceiling by HW round block & suitable size of MS fastener\nPWD SOR :-Page No-C-2 Item No-14(b)BI01010001010000000000000515BI010000147260each
362362Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with PVC sheet, placed in order to prevent concrete from entering the box.\nPWD SOR :-Page No-D-14 Item No-31BI01010001010000000000000515BI0100001473300each
363363Supplying & Fixing 240 V AC/DC superior type Multitune (min 10 nos. tune) Call Bell (Anchor) with selector switch for single/Multi Tunes mode, Battery operated on HW board incl. S&F HW board\nPWD SOR :-Page No-D-13 Item No-20(c)BI01010001010000000000000515BI010000147440each
364364Fixing only ceiling fan complete with blades, canopy, fork, rubber\nbush etc. incl. S&F connecting wire for down rod upto 30 cm incl.\npainting the rod with approved paint and making necessary\nconnection as required by 2x1.5 sqmm flexible copper wire.\nPWD SOR :-Page No-C-3 Item No-21(a)BI01010001010000000000000515BI0100001475300each
365365Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts &\nwashers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20\nPVC insulated flexible copper wire 0.5 mt. length\nPWD SOR :-Page No-C-4 Item No-29BI01010001010000000000000515BI01000014762each
366366Supply & Fixing electronics step type, Moduler Socket (2 module), Fan regulator (Legrand/Cabtree)\nPWD SOR :-Page No-E-18 Item No-10BI01010001010000000000000515BI0100001477180each
367367Supply & Fixing electronics step & Socket type Fan regulator (Anchor)\nPWD SOR :-Page No-E-6 Item No-18(b)BI01010001010000000000000515BI0100001478150each
368368Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust & supply GI louvre shutter after cutting hole on wall & mending good the damages of following diameter : 300mm (12\") sweep\n [PWD Page No-C-4, Item No:28(b) & D-14 Item No: 32(b)]BI01010001010000000000000515BI010000147980each
369369Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust & supply GI louvre shutter after cutting hole on wall & mending good the damages of following diameter :375mm (15\") sweep\n [PWD Page No-C-4, Item No:28(c) & D-14 Item No: 32(b)]BI01010001010000000000000515BI01000014806each
370370Supplying and Fixing GI water proof looping cable box ( 200 x 150 x 100mm ) having hinged GI Top Cover having 4 mm thick with rubber gasketlining, ,embeded on wall earthing terminal with lug etc. of the following sizes as indicated below,Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc.\n (PWD Page I-2 )[Item No: 16]BI01010001010000000000000515BI0100001481147each
371371Fixing only outdoor/street light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/ providing clamping arrangement & necy. GI reducer as required S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.\n(PWD Page C-3 )[Item No: 19]BI01010001010000000000000515BI0100001482147each
372372Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.\nlong and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground\nlevel as below( By ISI-Medium GI pipe) \n(PWD Page G-1)[Item No: 2(a)]BI01010001010000000000000515BI010000148336set
373373Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of No. 4 SWG on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. asrequired and mending good damages \n(PWD Page G-2)[Item No: 5(a){i}]BI01010001010000000000000515BI010000148490mtr
374374Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required\n (PWD Page G-2)[Item No: 4(a)]BI01010001010000000000000515BI010000148519mtr
375375Erection of 9.00 m ST bend pole with sole plate in CC foundation (600x600x150mm) thick CC (4:2:1) base block below sole plate with hard jhama metal incl CC (6:3:1) muffing 0.30 m dia 03.0 m above ground level incl making drilled hole on pole for earth bolt & carriage upto 1.6 Km from store to work site in cluding filling up the the exacavated earth pit with shifted soil .\n (PWD Page H-1)[Item No: 1(a)]BI01010001010000000000000515BI010000148645set
376376Painting the 9.00 m ST pole with two coats of aluminium paint of approved make over one coat of R.O primer incl preparation of surface by sand paper/emery incl cleaning etc.\n (PWD Page H-2)[Item No: 4(a) i&ii]BI01010001010000000000000515BI010000148745item
377377Earthing the the Installation by 50 mm dia G.I. Pipe (ISI -M) 3.64 mtr long & 1x4 SWG G.I.(Hot dip) wire (4 mtr long) with suitable nuts, bolts & washer etc. Incl S/F 15 mm dia GI protection pipe (1 mtr long) to be filled with bitumen partly under ground level & partly under ground level driven to an depth of 3.65 mtr below G.L. \n(PWD Page G-1)[Item No: 2(a)]BI01010001010000000000000515BI010000148845each
378378Fixing only Floodlight Fitting with suitable tie clamps and MS plate\nfor mounting on Pole/Tower or similar structure.Street fitting on ST bend pole & making necessary connection.\n(PWD Page C-3)[Item No: 20(a)]BI01010001010000000000000515BI010000148945each
379379Non Schedule Item Of Works(Electrical) :\nSupply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable (Make Gloster/Polycab/Havells/Mescab) \na) 3.5 x 95 sq mmBI01010001010000000000000515BI0100001490440mtr
380380Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable (Make Gloster/Polycab/Havells/Mescab) \nb) 3.5 x 70 sq mmBI01010001010000000000000515BI0100001491400mtr
381381Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable (Make Gloster/Polycab/Havells/Mescab) \nc) 3.5 x 50 sq mmBI01010001010000000000000515BI0100001492150mtr
382382Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable (Make Gloster/Polycab/Havells/Mescab) \nd) 3.5 x 35 sq mmBI01010001010000000000000515BI0100001493650mtr
383383Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable (Make Gloster/Polycab/Havells/Mescab) \ne) 3.5 x 25 sq mmBI01010001010000000000000515BI0100001494390mtr
384384Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable (Make Gloster/Polycab/Havells/Mescab) \nf) 4 x 16 sq mmBI01010001010000000000000515BI0100001495500mtr
385385Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable (Make Gloster/Polycab/Havells/Mescab) \ng)2 x 10 sqmmBI01010001010000000000000515BI0100001496120mtr
386386Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable (Make Gloster/Polycab/Havells/Mescab) \nh) 2 x 6 sq mmBI01010001010000000000000515BI0100001497850mtr
387387Supply of 601 mm12 W single Aluminium extruded LED batten light in square shape with high efficient polycarbonate diffuser for uniform lighting,complete with all acessaries (Make Legaro Lita RBJ 100 0012 /Crompton, cat no - LT8-865-2-525/Philips )BI01010001010000000000000515BI010000149890set
388388Supply of 1176 mm 24 W single Aluminium extruded LED batten light in square shape with high efficient polycarbonate diffuser for uniform lighting, complete with all acessaries(Make Legaro Lita RBJ 100 0024 /Crompton, cat no - LT8-865-2-525/Philips )BI01010001010000000000000515BI0100001499459set
389389Supply The stripo LED batten in square shape with aluminium housing & PC end cap. The luminaire and its\ncomponents are designed for Indoor application. Inbuilt high efficient LEDs used with milky white diffuser\nfor glare free high luminious output. of 1196 mm 40 W single Aluminium extruded LED batten light in square shape with high efficient polycarbonate diffuser for uniform lighting, complete with all acessaries (Make Legaro Stripo LST 1240 /Crompton/Philips )BI01010001010000000000000515BI0100001500180set
390390Supply and Delivery LED42 Watt Recessed grid - ceiling luminaire, suitable for 600 x 600 module and is enclosed with high efficient flat\nPMMA low glare diffuser complete with all acessaries(Make Legaro Modena LER 2642 /Crompton/Philips )BI01010001010000000000000515BI010000150128set
391391Supply & fixing LED Skirting lightdesigner step light with integrated high efficient LED designed for safety & style for stairways, patios,\ndecks, balcony,Foot Lamp(Night Lamp) Purpose areas & walkways complete with all acessaries \n (Make Lagraro,Locus1 cat no - LOD 3006 /Crompton/Philips)BI01010001010000000000000515BI010000150216each
392392Supply 18 Watt (Dimension 322x114x52) IP 66 LED street light with high pressure aluminium die cast body and lens toughened glass. Powered with high watt LED chips to give the best output. Cleo comes with light efficacy of 110 lm/w. Wider spread\nangle of lens with toughened glass provide extra coverage of light on road complete with all acessaries (Make Legaro Cleo, Cat no -LCL 0018 /Crompton/Philips/Havells)BI01010001010000000000000515BI010000150325each
393393Supply 36 Watt (Dimension 385x155x62) IP 66 LED street light with high pressure aluminium die cast body and lens toughened glass. Powered with high watt LED chips to give the best output. Cleo comes with light efficacy of 110 lm/w. Wider spread\nangle of lens with toughened glass provide extra coverage of light on road complete with all acessaries (Make Legaro Cleo, Cat no -LCL 0036 /Crompton/Philips/Havells)BI01010001010000000000000515BI010000150435each
394394Supply 72 Watt (Dimension 395x195x70) Unique designed Street light with High Power LED and Back driver opening comes with all the options\nsuitable for lighting outdoor application. Wider spread angle of lens with toughened glass provide extra\ncoverage of light on roads. Aluminium Die cast Housing with unique heat sink fins structure provides\nthermal management to natural convection. This IP 66 product comes with fixture efficacy of 110 lm/w.\n(Make Legaro Cleo, Cat no -LCL 0072 /Crompton/Philips/Havells)BI01010001010000000000000515BI010000150542each
395395Supply 110 Watt (Dimension 445x215x65) Unique designed Street light with High Power LED and Back driver opening comes with all the options\nsuitable for lighting outdoor application. Wider spread angle of lens with toughened glass provide extra\ncoverage of light on roads. Aluminium Die cast Housing with unique heat sink fins structure provides\nthermal management to natural convection. This IP 66 product comes with fixture efficacy of 110 lm/w.\n(Make Legaro Cleo, Cat no -LCL 00110 /Crompton/Philips/Havells)BI01010001010000000000000515BI010000150645set
396396Supply and fixing 9W LED light (Make Philips Ace Saver ,825 lm,10K life hours HSN CODE 85395000/ Crompton/Havells)tBI01010001010000000000000515BI010000150750each
397397Supply & fixing 12 W LED bulk head light fittings on wall/ ceiling complete set .(Legaro Sia Cat no-LBH 0012/Crompton/Philips/Havells)BI01010001010000000000000515BI010000150846each
398398Supply of 1200 mm sweep Ceiling Fan (Orient- New Breeze / Usha- Striker Plus : White or equivaent as approved by EIC) complete with all accessories including S & F necessary copper flexible wire.BI01010001010000000000000515BI0100001509300set
399399Supply & Fixing osilating type wall bracket Fan complete with all accessories to fixed on wall with ms fastener.(Orient Wall-45 )BI01010001010000000000000515BI01000015104set
400400Supply & delivery of the following split type AC machines (3 Star rated) (Make Carrier/ Hitachi/ Mitsubishi) complete with indoor outdoor unit & coper refrigerant pipes upto 5 mtr length with synthetic insulation, drain pipe etc.\na) 1 TR Split type (3 Star rated)BI01010001010000000000000515BI01000015112set
401401Supply & delivery of the following split type AC machines (3 Star rated) (Make Carrier/ Hitachi/ Mitsubishi) complete with indoor outdoor unit & coper refrigerant pipes upto 5 mtr length with synthetic insulation, drain pipe etc.\nb) 1.5 TR Split type(3 Star rated)BI01010001010000000000000515BI01000015127SET
402402Supply & delivery of the following split type AC machines (3 Star rated) (Make Carrier/ Hitachi/ Mitsubishi) complete with indoor outdoor unit & coper refrigerant pipes upto 5 mtr length with synthetic insulation, drain pipe etc.\nC) 2 TR Split type(3 Star rated)BI01010001010000000000000515BI01000015135set
403403Installation, testing & commissioning of the 1/1.5/2.0 ton capacity split Air Conditioners indoor and outdoor unit after cutting hole in wall as required and supply & installation of MS angle iron frame made by 40x40x5 mm thick & intermediate support by 25x6 mm MS flat for providing condensing unit after cutting in wall as required & mending good damages and finishing by sand, cement, 14 size stone chip as per direction of EICBI01010001010000000000000515BI010000151414set
404404Supply & fixing drawing copper pipe, Power cable, Drainage pipe with necessary insulation etc. complexBI01010001010000000000000515BI010000151556mtr
405405Supply & Fixing 240 V, 25 A, Modular type AC m/c starter (Eletron OLP - 3) 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire .(For AC m/c)BI01010001010000000000000515BI010000151628each
406406OUT DOOR FEEDER PILLAR no -1\nSupply & delivery at site, floor mounted, Double Door Type Feeder Pillar (IP-65/66), fabricated with 10 SWG MS sheet (External) & fixed on MS Angle Iron, totally enclosed, dust and vermin proof, with sloped foof and 4 Nos. Pedestals by 40 mm x 40 mm x 6 mm MS Angle Iron, each having length of 400 mm along with 6 mm thick MS foundation plate, welded at the bottom with holes on each etc. The Legs fitted with supporting Angle Iron Base Frame, are separable.\nThe Feeder Pillar will be powder coated painting. All sorts of inter connections by PVC insulated and unsheathed Copper conductor 'FR' having end finishing with socketing. Main Bus Bar by 4 x (32 mm x 9 mm) pure electrolytic graded Copper Flat on DMC Insulators & the Sub Main Bus Bars are 4 x ( 25 mm x 5 mm), for both 125A MCCBs & the MCBs of rating 80A & 63A would be inter connected by 25 Sq mm & 16 Sqmm PVC insulated and unsheathed 'FR' copper conductor wires etc. complete. The Inner Door behind the first door is of 16 SWG CRCA Sheet Metal. Inside of the Feeder Pillar, the cubicle / compartment type arrangement would be done, having Bus Bar Chamber &Cable Alley and will be incorporated with the following electrical accessories. There will be arrangement of entry/exit of cables through detachable gland plate at the bottom. The over all size of the Feeder Pillars are to be suitable to accomodate the following switching / measuring /indicating / bussing accessories and over all dimension of 1500 mm (W)x1500 mm (H)x 400 mm (D) (Excluding the Leg supports of height of 400 mm). Inscription level plates and should be of anodised /engraved to indicate the capacity /starting /destination of the feeders etc. The F. Pillar, base channels will be painted by powder coating system. There will be continuous 1x(38 mm x 6 mm) GI earth bus at the bottom rear end & would be projected at both sides of the Feeder Pillar. The F. Pillar would have the arrangement of cubicle illumination during open period of the door The GA drawing, SLD, wiring diagram and BOM should be approved by the EIC before fabrication of the Feeder Pillar. \nINCOMING SIDE :\na) 160A Four Pole MCCB of breaking capacity 25/35KA with thermal magnetic setting (L&T) --- 1 no\nb) 200A capacity Bus bar of 4 nos Alu bars on porcelain chairs--- 1 set \n OUTGOING SIDE :\n c) 125A Four Pole MCB (L&T) --- 1 no \nd) 63A Four Pole MCB (L&T) --- 2 nos\ne) 32A Four Pole MCB (L&T) --- 3 nos\nf) Danger board ---- 1 no\ni)DIGITAL AMMETER 96X96 SQ MM FLUSH MOUNTING; 3-Ph. Cl.1.0 (Make: L & T, Model Sl. No. WL131010)\nii)AMMETER SELECTOR SWITCH [OFF-R-Y-B Selection] (Make: KAYCEE or SALZER)\niii)CT 400/5A, CL-1 , VA- 15 TAPE WOUND TYPE (Make : KAPPA)\niv)LED INDICATION LAMP (R/Y/B); 240V AC CUT OUT 22.5 mm (3 Nos. in a Set) (Make: Siemens / L & T, Model GEN NEXT)\nv)6A SP MCB 'C' Curve Br Cap. 10 kA [3 Nos. in a Set] (Make: L & T, Model Sl. No. BB 10060C)\nvi)TIME SWITCH 24HRS. DAILY ANALOG TYPE 3-MODE (Make : Hager / L&T Model : AUTS03ANA00)\nvii)65A 4P CONTACTOR AC - 3 Duty 230V AC Coil + (1NO + 1NC) ADD-ON Aux. CONTACT (Make : LEGRAND Model : 4164 46 & 4168 58)\nviii)Vaishno make 6A 240V Door Limit Switch 1 NC Contact & 1 X 7 watt 240V AC Philips make LED BC Lamp with BC Holder ( all in a set)BI01010001010000000000000515BI01000015171set
407407.OUT DOOR FEEDER PILLAR NO- 2 \nSupply & delivery at site, floor mounted, Double Door Type Feeder Pillar (IP-65/66), fabricated with 10 SWG MS sheet (External) & fixed on MS Angle Iron, totally enclosed, dust and vermin proof, with sloped foof and 4 Nos. Pedestals by 40 mm x 40 mm x 6 mm MS Angle Iron, each having length of 400 mm along with 6 mm thick MS foundation plate, welded at the bottom with holes on each etc. The Legs fitted with supporting Angle Iron Base Frame, are separable.\nThe Feeder Pillar will be powder coated painting. All sorts of inter connections by PVC insulated and unsheathed Copper conductor 'FR' having end finishing with socketing. Main Bus Bar by 4 x (32 mm x 9 mm) pure electrolytic graded Copper Flat on DMC Insulators & the Sub Main Bus Bars are 4 x ( 25 mm x 5 mm), for both 125A MCCBs & the MCBs of rating 80A & 63A would be inter connected by 25 Sq mm & 16 Sqmm PVC insulated and unsheathed 'FR' copper conductor wires etc. complete. The Inner Door behind the first door is of 16 SWG CRCA Sheet Metal. Inside of the Feeder Pillar, the cubicle / compartment type arrangement would be done, having Bus Bar Chamber &Cable Alley and will be incorporated with the following electrical accessories. There will be arrangement of entry/exit of cables through detachable gland plate at the bottom. The over all size of the Feeder Pillars are to be suitable to accomodate the following switching / measuring /indicating / bussing accessories and over all dimension of 1500 mm (W)x1500 mm (H)x 400 mm (D) (Excluding the Leg supports of height of 400 mm). Inscription level plates and should be of anodised /engraved to indicate the capacity /starting /destination of the feeders etc. The F. Pillar, base channels will be painted by powder coating system. There will be continuous 1x(38 mm x 6 mm) GI earth bus at the bottom rear end & would be projected at both sides of the Feeder Pillar. The F. Pillar would have the arrangement of cubicle illumination during open period of the door The GA drawing, SLD, wiring diagram and BOM should be approved by the EIC before fabrication of the Feeder Pillar. \nINCOMING SIDE :\na) 250A Four Pole MCCB of breaking capacity 25/35KA with \n thermal magnetic setting (L&T) --- 1 no\nb) 315A capacity Bus bar of 4 nos Alu bars on porcelain chairs-- 1 set \n OUTGOING SIDE :c) 160A Four Pole MCCB of breaking capacity 25/35KA with \n thermal magnetic setting (L&T) --- 2 nos \nd) 63A Four Pole MCB (L&T) --- 1 no\ne) 32A Four Pole MCB (L&T) --- 1 no \n f) Danger board ---- 1 no)\nDIGITAL AMMETER 96X96 SQ MM FLUSH MOUNTING; 3-Ph. Cl.1.0 (Make: L & T, Model Sl. No. WL131010)\nii)AMMETER SELECTOR SWITCH [OFF-R-Y-B Selection] (Make: KAYCEE or SALZER)\niii)CT 400/5A, CL-1 , VA- 15 TAPE WOUND TYPE (Make : KAPPA)\niv)LED INDICATION LAMP (R/Y/B); 240V AC CUT OUT 22.5 mm (3 Nos. in a Set) (Make: Siemens / L & T, Model GEN NEXT)\nv)6A SP MCB 'C' Curve Br Cap. 10 kA [3 Nos. in a Set] (Make: L & T, Model Sl. No. BB 10060C)\nvi)TIME SWITCH 24HRS. DAILY ANALOG TYPE 3-MODE (Make : Hager / L&T Model : AUTS03ANA00)\nvii)65A 4P CONTACTOR AC - 3 Duty 230V AC Coil + (1NO + 1NC) ADD-ON Aux. CONTACT (Make : LEGRAND Model : 4164 46 & 4168 58)\nviii)Vaishno make 6A 240V Door Limit Switch 1 NC Contact & 1 X 7 watt 240V AC Philips make LED BC Lamp with BC Holder ( all in a set)BI01010001010000000000000515BI01000015181item
408408OUT DOOR FEEDER PILLAR NO- 3\nSupply & delivery at site, floor mounted, Double Door Type Feeder Pillar (IP-65/66), fabricated with 10 SWG MS sheet (External) & fixed on MS Angle Iron, totally enclosed, dust and vermin proof, with sloped foof and 4 Nos. Pedestals by 40 mm x 40 mm x 6 mm MS Angle Iron, each having length of 400 mm along with 6 mm thick MS foundation plate, welded at the bottom with holes on each etc. The Legs fitted with supporting Angle Iron Base Frame, are separable.The Feeder Pillar will be powder coated painting. All sorts of inter connections by PVC insulated and unsheathed Copper conductor 'FR' having end finishing with socketing. Main Bus Bar by 4 x (32 mm x 9 mm) pure electrolytic graded Copper Flat on DMC Insulators & the Sub Main Bus Bars are 4 x ( 25 mm x 5 mm), for both 125A MCCBs & the MCBs of rating 80A & 63A would be inter connected by 25 Sq mm & 16 Sqmm PVC insulated and unsheathed 'FR' copper conductor wires etc. complete. The Inner Door behind the first door is of 16 SWG CRCA Sheet Metal. Inside of the Feeder Pillar, the cubicle / compartment type arrangement would be done, having Bus Bar Chamber &Cable Alley and will be incorporated with the following electrical accessories. There will be arrangement of entry/exit of cables through detachable gland plate at the bottom. The over all size of the Feeder Pillars are to be suitable to accomodate the following switching / measuring /indicating / bussing accessories and over all dimension of 1500 mm (W)x1500 mm (H)x 400 mm (D) (Excluding the Leg supports of height of 400 mm). Inscription level plates and should be of anodised /engraved to indicate the capacity /starting /destination of the feeders etc. The F. Pillar, base channels will be painted by powder coating system. There will be continuous 1x(38 mm x 6 mm) GI earth bus at the bottom rear end & would be projected at both sides of the Feeder Pillar. The F. Pillar would have the arrangement of cubicle illumination during open period of the door The GA drawing, SLD, wiring diagram and BOM should be approved by the EIC before fabrication of the Feeder Pillar. \nINCOMING SIDE :: \na) 315A Four Pole MCCB of breaking capacity 25/35KA with \n thermal magnetic setting (Legrand/Siemens) ---1 no \nb) 400A capacity Bus bar of 4 nos Alu bars on porcelain chairs- 1 set \n OUTGOING SIDE :\nc) 200A Four Pole MCCB of breaking capacity 25/35KA with \n thermal magnetic setting (Legrand/Siemens) --- 1 no \nd) 160A Four Pole MCCB of breaking capacity 25/35KA with \n thermal magnetic setting (Legrand/Siemens) --- 1 no\ne) 63A Four Pole MCB (Legrand/Siemens) --- 1 no\nf) 32A Four Pole MCB (Legrand/Siemens) --- 3 nos\ng) Danger board v --- 1 no\ni)DIGITAL AMMETER 96X96 SQ MM FLUSH MOUNTING; 3-Ph. Cl.1.0 (Make: L & T, Model Sl. No. WL131010)\nii)AMMETER SELECTOR SWITCH [OFF-R-Y-B Selection] (Make: KAYCEE or SALZER)\niii)CT 400/5A, CL-1 , VA- 15 TAPE WOUND TYPE (Make : KAPPA)\niv)LED INDICATION LAMP (R/Y/B); 240V AC CUT OUT 22.5 mm (3 Nos. in a Set) (Make: Siemens / L & T, Model GEN NEXT)\nv)6A SP MCB 'C' Curve Br Cap. 10 kA [3 Nos. in a Set] (Make: L & T, Model Sl. No. BB 10060C)\nvi)TIME SWITCH 24HRS. DAILY ANALOG TYPE 3-MODE (Make : Hager / L&T Model : AUTS03ANA00)\nvii)65A 4P CONTACTOR AC - 3 Duty 230V AC Coil + (1NO + 1NC) ADD-ON Aux. CONTACT (Make : LEGRAND Model : 4164 46 & 4168 58)\nviii)Vaishno make 6A 240V Door Limit Switch 1 NC Contact & 1 X 7 watt 240V AC Philips make LED BC Lamp with BC Holder ( all in a set)BI01010001010000000000000515BI01000015191item
409409OUT DOOR FEEDER NO -4\nSupply & delivery at site, floor mounted, Double Door Type Feeder Pillar (IP-65/66), fabricated with 10 SWG MS sheet (External) & fixed on MS Angle Iron, totally enclosed, dust and vermin proof, with sloped foof and 4 Nos. Pedestals by 40 mm x 40 mm x 6 mm MS Angle Iron, each having length of 400 mm along with 6 mm thick MS foundation plate, welded at the bottom with holes on each etc. The Legs fitted with supporting Angle Iron Base Frame, are separable.\nThe Feeder Pillar will be powder coated painting. All sorts of inter connections by PVC insulated and unsheathed Copper conductor 'FR' having end finishing with socketing. Main Bus Bar by 4 x (32 mm x 9 mm) pure electrolytic graded Copper Flat on DMC Insulators & the Sub Main Bus Bars are 4 x ( 25 mm x 5 mm), for both 125A MCCBs & the MCBs of rating 80A & 63A would be inter connected by 25 Sq mm & 16 Sqmm PVC insulated and unsheathed 'FR' copper conductor wires etc. complete. The Inner Door behind the first door is of 16 SWG CRCA Sheet Metal. Inside of the Feeder Pillar, the cubicle / compartment type arrangement would be done, having Bus Bar Chamber &Cable Alley and will be incorporated with the following electrical accessories. There will be arrangement of entry/exit of cables through detachable gland plate at the bottom. The over all size of the Feeder Pillars are to be suitable to accomodate the following switching / measuring /indicating / bussing accessories and over all dimension of 1500 mm (W)x1500 mm (H)x 400 mm (D) (Excluding the Leg supports of height of 400 mm). Inscription level plates and should be of anodised /engraved to indicate the capacity /starting /destination of the feeders etc. The F. Pillar, base channels will be painted by powder coating system. There will be continuous 1x(38 mm x 6 mm) GI earth bus at the bottom rear end & would be projected at both sides of the Feeder Pillar. The F. Pillar would have the arrangement of cubicle illumination during open period of the door The GA drawing, SLD, wiring diagram and BOM should be approved by the EIC before fabrication of the Feeder Pillar. \nINCOMING SIDE :\na) 250A Four Pole MCCB of breaking capacity 25/35KA with \n thermal magnetic setting (L&T) --- 1 no\nb) 315A capacity Bus bar of 4 nos Alu bars on porcelain chairs-- 1 set \n OUTGOING SIDE :c) 160A Four Pole MCCB of breaking capacity 25/35KA with \n thermal magnetic setting (L&T) --- 2 nos \nd) 63A Four Pole MCB (L&T) --- 3 no\ne) 32A Four Pole MCB (L&T) --- 1 no \n f) Danger board ---- 1 no)\nDIGITAL AMMETER 96X96 SQ MM FLUSH MOUNTING; 3-Ph. Cl.1.0 (Make: L & T, Model Sl. No. WL131010)\nii)AMMETER SELECTOR SWITCH [OFF-R-Y-B Selection] (Make: KAYCEE or SALZER)\niii)CT 400/5A, CL-1 , VA- 15 TAPE WOUND TYPE (Make : KAPPA)\niv)LED INDICATION LAMP (R/Y/B); 240V AC CUT OUT 22.5 mm (3 Nos. in a Set) (Make: Siemens / L & T, Model GEN NEXT)\nv)6A SP MCB 'C' Curve Br Cap. 10 kA [3 Nos. in a Set] (Make: L & T, Model Sl. No. BB 10060C)\nvi)TIME SWITCH 24HRS. DAILY ANALOG TYPE 3-MODE (Make : Hager / L&T Model : AUTS03ANA00)\nvii)65A 4P CONTACTOR AC - 3 Duty 230V AC Coil + (1NO + 1NC) ADD-ON Aux. CONTACT (Make : LEGRAND Model : 4164 46 & 4168 58)\nviii)Vaishno make 6A 240V Door Limit Switch 1 NC Contact & 1 X 7 watt 240V AC Philips make LED BC Lamp with BC Holder ( all in a set)BI01010001010000000000000515BI01000015201item
410410Street Light FEEDER NO -1,2,3\n Supply & delivery at site, floor mounted, Double Door Type Feeder Pillar (IP-65/66), fabricated with 10 SWG MS sheet (External) & fixed on MS Angle Iron, totally enclosed, dust and vermin proof, with sloped foof and 4 Nos. Pedestals by 40 mm x 40 mm x 6 mm MS Angle Iron, each having length of 400 mm along with 6 mm thick MS foundation plate, welded at the bottom with holes on each etc. The Legs fitted with supporting Angle Iron Base Frame, are separable.The Feeder Pillar will be powder coated painting. All sorts of inter connections by PVC insulated and unsheathed Copper conductor 'FR' having end finishing with socketing. Main Bus Bar by 4 x (32 mm x 9 mm) pure electrolytic graded Copper Flat on DMC Insulators & the Sub Main Bus Bars are 4 x ( 25 mm x 5 mm), for both 125A MCCBs & the MCBs of rating 80A & 63A would be inter connected by 25 Sq mm & 16 Sqmm PVC insulated and unsheathed 'FR' copper conductor wires etc. complete. The Inner Door behind the first door is of 16 SWG CRCA Sheet Metal. Inside of the Feeder Pillar, the cubicle / compartment type arrangement would be done, having Bus Bar Chamber &Cable Alley and will be incorporated with the following electrical accessories. There will be arrangement of entry/exit of cables through detachable gland plate at the bottom. The over all size of the Feeder Pillars are to be suitable to accomodate the following switching / measuring /indicating / bussing accessories and over all dimension of 1500 mm (W)x1500 mm (H)x 400 mm (D) (Excluding the Leg supports of height of 400 mm). Inscription level plates and should be of anodised /engraved to indicate the capacity /starting /destination of the feeders etc. The F. Pillar, base channels will be painted by powder coating system. There will be continuous 1x(38 mm x 6 mm) GI earth bus at the bottom rear end & would be projected at both sides of the Feeder Pillar. The F. Pillar would have the arrangement of cubicle illumination during open period of the door The GA drawing, SLD, wiring diagram and BOM should be approved by the EIC before fabrication of the Feeder Pillar. Supply & installation of 4 mm thick M.S. out door type Feeder Pillar Box having both side ventilation louvers with inclined roof of size (1050 x 900 x 400 mm) having hinged door & mechanical locking arrangement suitably grouted on 250mm masonary platform 450 below G.L. & 600mm above G.L. plastering & neatly cemented finish. The Feeder pillar box should comprise double door type cubicle panel inside it, fabricated by 3mm thick M.S. sheet with necessary slot for incomming outing MCCB/MCBs bus bar & necessary interconnection with suitable capacity PVC insulated copper wire duly socketed at both end comprising of the following control device.\na) 100A Four Pole MCB (Legrand/Siemens) --- 1 no\nb)125A capacity Bus bar of 4 nos Alu bars on porcelain chairs--- 1 set \n c) 32A Four Pole MCB (Legrand/Siemens) --- 6 nos \nd Electronic time switch (daily)(make Legrand/L&T) with \n 32A four pole power contractor with 240V magnet coil &\n by-pass switching arrangement (Make L&T/Siemens) ---- 3 sets\ne) Danger board ---- 1 no\nDIGITAL AMMETER 96X96 SQ MM FLUSH MOUNTING; 3-Ph. Cl.1.0 (Make: L & T, Model Sl. No. WL131010)\nii)AMMETER SELECTOR SWITCH [OFF-R-Y-B Selection] (Make: KAYCEE or SALZER)\niii)CT 400/5A, CL-1 , VA- 15 TAPE WOUND TYPE (Make : KAPPA)\niv)LED INDICATION LAMP (R/Y/B); 240V AC CUT OUT 22.5 mm (3 Nos. in a Set) (Make: Siemens / L & T, Model GEN NEXT)\nv)6A SP MCB 'C' Curve Br Cap. 10 kA [3 Nos. in a Set] (Make: L & T, Model Sl. No. BB 10060C)\nvi)TIME SWITCH 24HRS. DAILY ANALOG TYPE 3-MODE (Make : Hager / L&T Model : AUTS03ANA00)\nvii)65A 4P CONTACTOR AC - 3 Duty 230V AC Coil + (1NO + 1NC) ADD-ON Aux. CONTACT (Make : LEGRAND Model : 4164 46 & 4168 58)\nviii)Vaishno make 6A 240V Door Limit Switch 1 NC Contact & 1 X 7 watt 240V AC Philips make LED BC Lamp with BC Holder ( all in a set)\nThe above Pillar box to be installed on brick cement rectangulr plat form 600mm below the GL & 600mm Above GL duly plastered & neatly cemnted finishBI01010001010000000000000515BI01000015213item
411411Supply & delivery of 150mm borewell 3ph. 440V 15 H.P(11KW) 9 stage . Sub-Mersible Pump-Motor set of approved make of 80mm dia outlet(Make - Kirloskar cat no. KS6F-1509R, D12761007153/KSB)BI01010001010000000000000515BI01000015222Set
412412Supply & delivery of 150mm borewell 3ph. 440V 10 H.P(7.5KW) 10 stage . Sub-Mersible Pump-Motor set of approved make of 80mm dia outlet(Make - Kirloskar cat no. KS6EA-1010R, D12761505153/KSB)BI01010001010000000000000515BI01000015232set
413413Supply & Fixing of control panel suitable for 3-Phase 10 HP(7.5 KW) Submersible Pump motor set comprising of FASD starter,Relay Range(6 - 10) to be fixed on wall incl making connection & necy. earthing attachment.\n (Make L&T Type MU-G15 FASD [HSN Code 8536]] Cat no. CS94091SOVO/Crompton/KSB)BI01010001010000000000000515BI01000015242set
414414Supply & Fixing of control panel suitable for 3-Phase 15 HP(11 KW) Submersible Pump motor set comprising of FASD starter,Relay Range(9 - 14),&Coil Voltage of 415 V to be fixed on wall incl making connection & necy. earthing attachment.\n (Make L&T Type MU-G20 FASD (With Wideband Coil) [HSN Code 8536] Cat no. SS95984DOAO/Crompton/KSB)BI01010001010000000000000515BI01000015252set
415415Supply & Laying 3 core 4 sqmm flat submersible cable (Mescab/Finolex/Havells)BI01010001010000000000000515BI0100001526240mtr
416416Supply & Laying 3 core 2.5 sqmm flat submersible cable (Mescab/Finolex/Havells)BI01010001010000000000000515BI0100001527240mtr
417417Labour charge for Testing & Lowering the submersible Pump motor set with submersible cable along with the column pipes into the tube well after socketing the column pipes step by step including arrangement of tripod, chain pully & tools & Tackles & providing suitable manpower to satisfactory operation.\nBI01010001010000000000000515BI01000015286set.
418418Supply & installation of 80 mm dia G.I. pipe (Make TATA-M) having heavy duty G.I. socket/elbow (TATA) incl cutting & threading as required a) Make TATA Medium (For Vertical column pipe & upto header).(Including 12% GST)\n Sanitary Plumbing Schedule (A)-(II) G.I. pipe & fittings item no -1(f) (ii)\nBI01010001010000000000000515BI0100001529200mtr
419419Supplying, fitting and fixing gunmetal 80 mm dia wheel valve of approved brand and make tested to 21 kg per sq. cm. (for Header only).(Including 12% GST)\nSanitary Plumbing Schedule(A)-(II) G.I. PIPE WORKS AND FITTINGS\nBI01010001010000000000000515BI010000153012each
420420Supplying, fitting and fixing check valve G.M. tested to 21 kg per\nsq. cm.Cast Steel Non Return Valve 3 Inch DIA\n(GeM Price List)BI01010001010000000000000515BI01000015316each
421421Supply Of MS 9M,113 KG weight of Designation 410-SP-28 Sweged and Welded Steel tubular Poles as per IS-2713-1980 With Single Arm Bracket made of 40 mm Dia 1.5 Mtr Long Including MS cap (Calcutta Poles &Tubes Co/Utkarsh/Banshal)\nBI01010001010000000000000515BI010000153245each
422422Supply delivery at site on foundation, commissioning of 100 KVA 415V, 50HZ, 3ph silent new DG Set, comprising of Engine, alternator, Manual Control Panel, Base frame, Fuel tank, Battery, CPCB - II approved Engine & Acoustic Enclosure. Make ( Jakson/ Kirloskar/Ashok layland Koel Green) as approved EIC.BI01010001010000000000000515BI01000015332set
423423Installation, testing & commissioning with full fuel tank of the above D.G. set to satisfactory operation.BI01010001010000000000000515BI01000015342job

AI Tender Summary

OUR REF NO 28186920
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 07-07-2021
Authority
Authority Name West Bengal State Police Housing Corporation Limited
Work Description Construction Of Subsidiary Correctional Home At Chanchal- ( Part-2 ) - Balance Work . ( 1St Call )
Basic Detail
Tender No WBPHIDCL/Asst.CE/NIT- 24(e)/2021-2022
Bidding Type Tender
Location
City Chanchal
State West Bengal
Key Dates
Publish Date 14 Jun 2021
Submission Date 07 Jul 2021
Open Date 09 Jul 2021
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 23.38 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
EE505319-63BA-4B38-B6DF-33A56CF840DF.html
BOQ_634019.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 14, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 07, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 09, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

html

EE505319-63BA-4B38-B6DF-33A56CF840DF.html

xls

BOQ_634019.xls

Disclaimer