Rate Contract For Maintenance Of Engine Alternator At Various Te Bldgs / Bts Sites Under Bsnl Electrical Sub Division Nasik Under Nasik Ssa. ( 2 Nd Call )

Tender Notice

28184858
Corrigendum : Rate Contract For Maintenance Of Engine Alternator At Various Te Bldgs / Bts Sites Under Bsnl Electrical Sub Division Nasik Under Nasik Ssa. ( 2 Nd Call )
Indian
Maharashtra
15-06-2021
06-07-2021
07-07-2021

Tender Details

Rate Contract For Maintenance Of Engine Alternator At Various Te Bldgs / Bts Sites Under Bsnl Electrical Sub Division Nasik Under Nasik Ssa. ( 2 Nd Call )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jun-2021 Corrigendum 1 Other 06-07-2021

Key Value

Document Fees
INR 590 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Rate Contract for maintenance of Engine Alternator at various TE Bldgs/ BTS sites under BSNL Electrical Sub Division Nasik under Nasik SSA.
Sl. No. Item Description
1Attending and rectification of EA 7.5 KVA to 62.5 KVA set faults including providing minor spares if reqd such as connecting copper wires, removing air from fuel pump, control fuse, ferrules, lugs i/c minor works etc etc alongwith testing & commissioning etc. in URBAN site complete as required ( within vicinity of 25 Kms.) (Item will be measured on submission of visit report duly signed by BSNL authority and allowed atonce per site per fault) (Note:- For subsequent visit to attend the DG set to provide the items hereunder will not be paid separately. It is assumed that all items as below shall be carried out by firm in first visit only)
2Attending and rectification of EA 7.5 KVA to 62.5 KVA set faults including providing minor spares if reqd such asconnecting copper wires, removing air from fuel pump, control fuse, ferrules, lugs i/c minor works etc etcalongwith testing & commissioning etc. in RURAL site complete as required beyond25 Kms. (Item will be measured on submission of visit report duly signed by BSNL authority and allowed atonce per site per fault) (Note:- For subsequent visit to attend the DG set to provide the items hereunder will not be paid separately. It is assumed that all items as below shall be carried out by firm in first visit only)
3Carrying out "B" Check servicing of following capacity E/A sets located at various T.E. Bldg / BTSunder BSNL Electrical Sub-Division, Dombivali including replacement of old engine oil, fuel filter, lubricating oil filter etc. by new as per manufactures recommendation including arranging vehicle, transportation, manpower, tools and tackles, testing etc. as required. (Oil, filters shall be manufacturerrecommonded specs) (Note: This item includes visit charges, nothing extra on this account shall be paid)
47.5 KVA /10 KVA ( KOEL)
515/20 KVA (KOEL/M&M)
632.5 KVA ( KOEL/GREAVES )
745/50 KVA (KOEL/CUMMINS )
862.5 KVA ( KOEL/GREAVES/CUMMINS)
9Supplying & filling of coolent in radiator of water cooled EA set etc as required.
10Supplying & fixing following spare parts alongwith removing of old items etc.complete as required.( Make- Recommended by manufacture/BSNL makes only. ) (Note :- The agency shall be consideredsuitable creditfor recovered spareswhile quoting rates )
11Above 7.5 KVA TO 32.5 KVA
12Repairs of self starteri/c replacement of spares / winding etc as required
13Repairs of charging alternator i/c replacement of spares / winding etc as required
14Fuel pipe steel braded with banjo bolt( feed pump to fuel filter )
15Fuel pipesteel braded with banjo bolt ( Pre filterto tank unit)
16Fuel pipesteel braded with banjo bolt ( Fuel filter to FIP )
17Automatic voltage regulator (AVR)
18Pump caliberation only from authorised dealer with test report
19V belt ( A46)
20V belt ( A56)
21Above 32.5 KVA TO 62.5 KVA
22Repairs of self starteri/c replacement of spares / winding etc as required
23Repairs of charging alternator i/c replacement of spares / winding etc as required
24Fuel pipe steel braded with banjo bolt( feed pump to fuel filter )
25Fuel pipesteel braded with banjo bolt ( Pre filterto tank unit)
26Fuel pipesteel braded with banjo bolt ( Fuel filter to FIP )
27Automatic voltage regulator (AVR)
28RepairingofEngine Alternator setsby supplying & fixing following spare parts alongwith removing of old units etc.complete as required.( Make- Recommended by manufacture/BSNL makes only.)
29SMPS 12 volt, 10 Amp Battery Charger
3088 Ah, 12 volt Battery
31130 Ah, 12 volt Battery
3215 W 40 Lubricating oil for topping up in EA set( Only recommeded make )
33Set of end socket with copper lugs for DG starting battery
34S/F of 2 nos 35 sqmm copper flexible lead (approx.1.0 Mtr) for DG starting battery
35ON/OFF push button
36Starting switch with key
37Radiator Hose kit
38Mains/DG contactor
39Stop solenoid
4063 amps. ratings , TPN MCB, “C” curve,10 KA breaking capacity
41Overhauling & Reconditioning of radiator of up to 32.5KVA DGset which includes Dismantling the complete radiator fanassembly from the engine, dismantling radiator assembly, transporting to workshop, pressure testing, tracing the leakage in the tube, attending & repairingof leakages, brazing, welding damaged sections, cleaning of all fins with air pressure, cleaning of rusted portion of radiator, Servcing & cleaning of whole radiator, providing anti rust coating, hydraulic pressure testing,and refixing of radiator assembly , tesing & trial run of DG set etc. complete asrequired.
42Overhauling & Reconditioning of radiator of above 32.5 KVA to62.5 KVA DGset which includes Dismantling the complete radiator fanassembly from the engine, dismantling radiator assembly, transporting to workshop, pressure testing, tracing the leakage in the tube, attending & repairingof leakages, brazing, welding damaged sections, cleaning of all fins with air pressure, cleaning of rusted portion of radiator, Servcing & cleaning of whole radiator, providing anti rust coating, hydraulic pressure testing,and refixing of radiator assembly , tesing & trial run of DG set etc. complete asrequired.
43SHII ( Credit for dismantailed material)
44Suitable credit to the old dismantled battery of following capacity
45Above 88 AH to 130 AH