| 1 | 1 | CIVIL | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1.01 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. | | 27.73 | cum |
|---|
| 3 | 1.02 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below | BI01010001010000000000000515BI0100001114 | 2.52 | Each |
|---|
| 4 | 1.03 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazingand false ceiling including disposal of unserviceable surplus material andstacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. | BI01010001010000000000000515BI0100001114 | 68.25 | sqm |
|---|
| 5 | 1.04 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | BI01010001010000000000000515BI0100001114 | 99.84 | sqm |
|---|
| 6 | 1.05 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) | BI01010001010000000000000515BI0100001114 | 14.45 | sqm |
|---|
| 7 | 1.06 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) | BI01010001010000000000000515BI0100001114 | 140 | sqm |
|---|
| 8 | 1.07 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. | BI01010001010000000000000515BI0100001114 | 453.86 | Kg |
|---|
| 9 | 1.08 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001114 | 7 | cum |
|---|
| 10 | 1.09 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | BI01010001010000000000000515BI0100001114 | 120 | sqm |
|---|
| 11 | 1.1 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. | BI01010001010000000000000515BI0100001114 | 120 | sqm |
|---|
| 12 | 1.11 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour Two coats | BI01010001010000000000000515BI0100001114 | 99.84 | sqm |
|---|
| 13 | 1.12 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work | BI01010001010000000000000515BI0100001114 | 34.13 | sqm |
|---|
| 14 | 1.13 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles. | BI01010001010000000000000515BI0100001114 | 66.56 | sqm |
|---|
| 15 | 1.14 | Providing and fixing factory made shutters of Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium 'U' type edge beading allround the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws, including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in- Charge (Cost of 'U' beading and hinges will be paid for separately). 25 mm thick | BI01010001010000000000000515BI0100001114 | 2.52 | sqm |
|---|
| 16 | 1.15 | Providing and fixing aluminum U beading of required size to Pre-laminated/flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001114 | 10.8 | Kg |
|---|
| 17 | 1.16 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | BI01010001010000000000000515BI0100001114 | 2 | Each |
|---|
| 18 | 1.17 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 75x63x4 mm | BI01010001010000000000000515BI0100001114 | 4 | Each |
|---|
| 19 | 1.18 | Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm | BI01010001010000000000000515BI0100001114 | 2 | Each |
|---|
| 20 | 1.19 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm | BI01010001010000000000000515BI0100001114 | 2 | Each |
|---|
| 21 | 1.2 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm | BI01010001010000000000000515BI0100001114 | 4 | Each |
|---|
| 22 | 1.21 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper | BI01010001010000000000000515BI0100001114 | 2 | Each |
|---|
| 23 | 1.22 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. | BI01010001010000000000000515BI0100001114 | 78.81 | sqm |
|---|
| 24 | 1.23 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase | BI01010001010000000000000515BI0100001114 | 34 | meter |
|---|
| 25 | 1.24 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers | BI01010001010000000000000515BI0100001114 | 5.95 | sqm |
|---|
| 26 | 1.25 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) | BI01010001010000000000000515BI0100001114 | 54.49 | sqm |
|---|
| 27 | 1.26 | Grading roof for water proofing treatment with Cement mortar 1:4 (1cement : 4 coarse sand) | BI01010001010000000000000515BI0100001114 | 1.71 | cum |
|---|
| 28 | 1.27 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | BI01010001010000000000000515BI0100001114 | 30 | sqm |
|---|
| 29 | 1.28 | Carefully removing existing water proofing plaster of thickness up to 25mm from cement based waterproofing treatment on the terrace including dressing and stacking the rubish within 50 mtr lead. | BI01010001010000000000000515BI0100001114 | 68.25 | sqm |
|---|
| 30 | 1.29 | Providing and laying water proofing cement plaster treatment over terrace consisting of following applications:\n\n(A) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge upto 300 mm height including cleaning the surface before treatment.\n\n(B) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel as per direction by Engineer-in-charge. | BI01010001010000000000000515BI0100001114 | 68.25 | sqm |
|---|
| 31 | 1.3 | Dismantling tile work up to 10 to 25mm thickness on wall laid in cement mortar, Polymmer modified motar including stacking material within 50 metres lead. | BI01010001010000000000000515BI0100001114 | 39.36 | sqm |
|---|
| 32 | 1.31 | Carefully making hole by removing loose/damaged bricks using chisel & cutting machine from brickwall approximately at 1000mm C/c including removal of damaged brick in between, clearing all loose material from the hole and filling with cemen concrete 1:2:3 ( 1 cement : 2 Coarse sand : 4 fine aggregate of size 10mm & down) including all labour, materials, grouting required , reinforcement etc. complete as per direction of engineer-in-charge.\nThe size of hole shall be (115 x 115 x 75)mm approximately. | BI01010001010000000000000515BI0100001114 | 139.4 | sqm |
|---|
| 33 | 2 | ELECTRICAL | | | |
|---|
| 34 | 2.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable etc. as required. Group B | BI01010001010000000000000515BI0100001114 | 9 | Point |
|---|
| 35 | 2.02 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable etc. as required. Group C | BI01010001010000000000000515BI0100001114 | 9 | Point |
|---|
| 36 | 2.03 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. Mm | BI01010001010000000000000515BI0100001114 | 26 | meter |
|---|
| 37 | 2.04 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. Mm | BI01010001010000000000000515BI0100001114 | 120 | meter |
|---|
| 38 | 2.05 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 6 sq. Mm | BI01010001010000000000000515BI0100001114 | 25.5 | meter |
|---|
| 39 | 2.06 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm | BI01010001010000000000000515BI0100001114 | 43 | meter |
|---|
| 40 | 2.07 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm | BI01010001010000000000000515BI0100001114 | 95.5 | meter |
|---|
| 41 | 2.08 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch | BI01010001010000000000000515BI0100001114 | 7 | Each |
|---|
| 42 | 2.09 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch | BI01010001010000000000000515BI0100001114 | 9 | Each |
|---|
| 43 | 2.1 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet | BI01010001010000000000000515BI0100001114 | 7 | Each |
|---|
| 44 | 2.11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet | BI01010001010000000000000515BI0100001114 | 9 | Each |
|---|
| 45 | 2.12 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 1 or 2 Module (75mmX75mm) | BI01010001010000000000000515BI0100001114 | 2 | Each |
|---|
| 46 | 2.13 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 3 Module (100mmX75mm) | BI01010001010000000000000515BI0100001114 | 2 | Each |
|---|
| 47 | 2.14 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 6 Module (200mmX75mm) | BI01010001010000000000000515BI0100001114 | 7 | Each |
|---|
| 48 | 2.15 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001114 | 3 | Each |
|---|
| 49 | 2.16 | Supplying, Installation, commissioning & testing of ceiling fan 1200 mm, BEE 5 Star rated without regulator including wiring the down rod with 1.5 sqmm PVC insulated copper wire single core cable complete as reqd. (Crompton Greaves HS Plus 48-inch 53-Watt Power Saver Ceiling Fan (White) or equivalent make Crompton Greaves, Bajaj, Havells) | BI01010001010000000000000515BI0100001114 | 6 | Each |
|---|
| 50 | 2.17 | Supplying, Installation, Testing and Commisioning of recessed Mounted ultraslim LED fixture flat panel 2' x 2' made of extruded aluminium frame with high efficient LEDs & glare free opal diffuser min 36 watt complete in false ceiling with driver (constant current and constant voltage) complete in every way as required. (Halonix CAT Ref. No. HLFPU22-02-36-WW or its equivalent) | BI01010001010000000000000515BI0100001114 | 15 | Each |
|---|
| 51 | 2.18 | Supplying and fixing of RJ 45 CAT 6 information outlet (I/O) for data, voice rack end complete with feruling and end termination as required.(Make:-(Belden/Legrand-Myrius/MK/Schnider/Crabtree) | BI01010001010000000000000515BI0100001114 | 2 | Each |
|---|
| 52 | 2.19 | Supplying and fixing one module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | BI01010001010000000000000515BI0100001114 | 6 | Each |
|---|
| 53 | 2.2 | Removing and refixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required after completion of necessary civil work.Upto 35 sq. mm (clamped with 1mm thick saddle) | BI01010001010000000000000515BI0100001114 | 75 | meter |
|---|