Repairs To Floorings Certain Rcc Works Plasterings Leakage Of Seepage Joinerys Replacement Of Ac Sheet And False Ceiling Aluminium Works Plumbing Guniting And External Periodical Services And Internal Wiring To Certain Married Accommodation At, GE (AF) Gurgaon-Haryana

Military Engineer Services-MES has published Repairs To Floorings Certain Rcc Works Plasterings Leakage Of Seepage Joinerys Replacement Of Ac Sheet And False Ceiling Aluminium Works Plumbing Guniting And External Periodical Services And Internal Wiring To Certain Married Accommodation At. Submission Date for this Tender is 10-07-2021. Electrification Work Tenders in GE (AF) Gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

28174552
Corrigendum : Repairs To Floorings Certain Rcc Works Plasterings Leakage Of Seepage Joinerys Replacement Of Ac Sheet And False Ceiling Aluminium Works Plumbing Guniting And External Periodical Services And Internal Wiring To Certain Married Accommodation At
Open Tender
Indian
Haryana
GE (AF) Gurgaon
10-07-2021

Tender Details

Repairs To Floorings Certain Rcc Works Plasterings Leakage Of Seepage Joinerys Replacement Of Ac Sheet And False Ceiling Aluminium Works Plumbing Guniting And External Periodical Services And Internal Wiring To Certain Married Accommodation At

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Jun-2021 Amendment1 BOQ 03-07-2021
2 03-Jul-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-07-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work :REPAIRS TO FLOORINGS, CERTAIN RCC WORKS, PLASTERINGS LEAKAGE OF SEEPAGE, JOINERYS, REPLACEMENT OF AC SHEET AND FALSE CEILING, ALUMINIUM WORKS, PLUMBING, GUNITING AND EXTERNAL PERIODICAL SERVICES AND INTERNAL WIRING TO CERTAIN MARRIED ACCOMMODATION AT AF STN ARJANGARH UNDER AGE (AF) AYANAGAR OF GE (AF) GURGAON
Sl. No. Item Description Item Code / Make Quantity Units
1 1 B/R WORKS\nDemolition of stone slabs and tiles of any description or thickness in floors/walls, aprons etc laid bedded and pointed in any mortar. 5 X Sqm
2 2 Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness ( below or above ground level) complete all as specified and as directed. 34.5 Cum
3 3 Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land, complete all as specified. 600 Sqm
4 4 M&L Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished even and fair complete all as specified. 300 Sqm
5 5 M&L Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified. 200 Sqm
6 6 M&L Rendering 10 mm thick in cement mortar (1:3), as on concrete surfaces (such as top & sides of chajjas, beams, balcony ceiling etc.) finished even and smooth without using extra cement, complete all as specified and directed. 100 Sqm
7 7 Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing)removing serviceable tiles to store and rubbish off the permises complete all as specified and as directed 450 Sqm
8 8 M&L First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sq.m but not exceeding 0.16 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles and leveling the floor with PCC 1:2:4 type B0 of required thickness if required to maintain slope etc. , complete all as specified. 80 Sqm
9 9 M&L First quality, Non skid ceramic coloured joint free tiles, 7 to 8 mm thick (square or rectangular) area of each tile exe 0.18 Sqm but n.exe 0.38 Sqm, laid in floors set and jointed with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles, and leveling the floor with PCC 1:2:4 type B0 of required thickness if required to maintain slope etc. complete all as specified. 200 Sqm
10 10 All as per item No 09 above but on vertical surfaces such as skirting fixed on and including 10mm thick rendering in cement mortar 1:4 as backing coat complete all as directed by Engr-in-charge. 20 Sqm
11 11 M & L first quality coloured glazed ceramic tiles, fixed in pattern of different colour including border of size 300x 450 x 7mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid on and including 10 mm thick rendering in cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles, complete all as specified and directed. Note :- Pattern of the tiles will be decided by GE at the time of execution. 150 Sqm
12 12 Supply and fixing, drapery rod of mild steel 25mm dia, ribbed/fancy type, PVC powder coated, any shade, including set of fixing brackets, for span not exceeding 2m, fixed to wall in repairs, with PVC finols/finnels, connected accessaries, rubber packing, required screws and PVC rawal plugs as required complete all as specified and as directed. 100 RM
13 13 Preparation of newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed. 300 Sqm
14 14 M & L preparation of newly plastered surface of ceiling and applying three coats of white wash up to 4 mtr height. complete all as specified and as directed. 100 Sqm
15 15 Material and labour preparation of new plastered surfaces and apply two coat of oil bound distmper over a coat of primer, complete all as specified and directed. 200 Sqm
16 16 Supply and fixing in repairs, stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to steel frames with tinned tacks, or galvanized wire staples, or fixed to wooden frames with first class hard wood bead, complete all as specified and directed. 15 Sqm
17 17 Supply and fixing, stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to steel frames with tinned tacks, or galvanized wire staples, or fixed to wooden frames with first class hard wood bead, complete all as specified and directed. 20 Sqm
18 18 M&L complete removal of existing treatment by scraping down completely on brick wall/concrete surfaces thoroughly, washing, rubbing down with water cleaning the surface upto the entire satisfaction of Engineer-in-Charge and including opening of existing cracks , filling up of "V" cracks with epoxy expandable putty to required depth, making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4 incl necessary filling and applying of Birla white putty on entire surfaces to obtain/achieve smooth even surfaces with using sand paper and applying two coat of exterior emulsion paint 100% acrylic of approved colour and shade by accepting officers over and including a coat of primer as per manufacturers instrctions complete all as specified and directed by Engineer-in-Charge. including necessary scafolding upto 4th floor. 4000 Sqm
19 19 All as per srl item No 18 above but without complete removal and applying one coat of exterior emulsion paint 100% acrylic of make given in item No 18 above on old decorated surface including opening of existing cracks , filling up of "V" cracks with epoxy expandable putty to required depth , making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4, including necessary form work upto 4th floor. complete all as pecified and as directed. 500 Sqm
20 20 M&L complete removal of existing treatment by scraping down completely on brick wall/concrete/plastered surfaces thoroughly, washing, rubbing down with water cleaning the surface upto the entire satisfaction of Engineer-in-Chargeand a primer coat of " cemprover of M/S Snocem on entire surfaces and filling the craks/depression/holes etc by putty as directed and making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4 than applying two coat of cement base paint coating of approved colour and shade by accepting officers on walls upto 4th floor complete complete all as specified and directed by Engineer-in-Charge. including necessary form work upto 4th floor. 1000 Sqm
21 21 M&L complete removal of existing treatment by scraping down washing rubbing down with water and cleaning the surface up to the entire satisfaction of Engineer-in-Charge and including opening of existing cracks , filling up of "V" cracks with epoxy expandable putty to required depth, making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4 applying two coat of oil emulsion over 2 to 3 mm thick birla putty punning complete all as specified or as directed by Engineer-in -Charge. 2500 Sqm
22 22 Preparation of old surfaces of ceiling including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. and applying one coat of white wash up to 4 mtr height , complete all as specified and directed. 250 Sqm
23 23 M&L for Preparation of old painted surfaces of wood based surfaces of any description over 10 cms width or girth by applying sand paper etc.for proper preparation and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks all as specified and directed.(Note-Payment shall be made for one coat only ) complete all as specified and directed. 50 Sqm
24 24 Preparing old painted surfaces of steel and iron surfaces over 10 cm width or girthby cleaning, sand papering, brushing with wire brushes, scrapping by steel scrappers etc , filling in crevices and cracks etc with approved filler and applying One coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. 50 Sqm
25 25 Taking down steel tubing 15mm bore and connections including cleaning for refixing or removing to stores complete all as specified and directed by Engineer - in – Charge. 100 RM
26 26 All as per Srl Item No 25 here in before but 20mm bore all as specified and directed by Engineer - in - Charge. 100 Rm
27 27 S & F 15mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and directed. Note : Cutting chases as required shall be measured and paid seperately. 100 RM
28 28 S & F 20 mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and directed. Note : Cutting chases as required shall be measured and paid seperately. 100 RM
29 29 Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth, including removal of rubbish outside MoD land complete all as specified. 50 RM
30 30 S & F in repairs Ist quality vitreous china wash basin, white, flat back, size 550x400mm, PVC connections suitable for hot and cold water,bottle trap (with internal partition) 32 mm size with 300mm &190mm long wall connection pipes & wall flange, and fixing withbrackets/bolts including cutting and pinning in etc complete all as specified and directed by Engineer - in – Charge . 5 Each
31 31 Ditto all as above in item No 30 but fixing only 3 Each
32 32 Supply and fix in repairs Cast iron floor trap with dia of outlet 100 mm, with CP grating hinge type in kitchen and other situation including PCC 1:2:4 type B1 for setting the trap and jointing to waste pipe including taking out old floor trap , complete all as specified and directed. 5 Each
33 33 Supply and fix in repairs Cast iron floor trap with dia of outlet75 mm, with CP grating with hinge in kitchen and bath etc situation including PCC 1:2:4 type B1 for setting the trap and jointing to waste pipe including taking out old floor trap , complete all as specified and directed. 5 Each
34 34 Dismantling of cast iron or reiforced concrete drain pipes jointed in cement mortar and taking out from trenches 100 / 75 mm bore (sand cast) all as specified and directed 40 RM
35 35 Material and labour, 100mm dia cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, including cement jointing, laid in trenches or in floors including necessary excavation and earth work, complete all as specified and directed. 10 RM
36 36 Material and labour, 100mm dia cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, including cement jointing, fixed to wall with and including mild steel clamps and bolts with washers, complete all as specified and directed. 10 RM
37 37 Material and labour, 75mm dia cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, including cement jointing, laid in trenches or in floors including necessary excavation and earth work, complete all as specified and directed. 10 RM
38 38 Material and labour, 75mm dia cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, including cement jointing, fixed to wall with and including mild steel clamps and bolts with washers, complete all as specified and directed. 10 Rm
39 39 S & F 100mm bore bends, diminishing pieces or tapers all as specified and directed 4 Each
40 40 S & F 75mm bore bends, diminishing pieces or tapers all as specified and directed 4 Each
41 41 Supply and fix Vitreous China wash down water closet'constellation premium white colour complete set incl cistern with lid cover fixed in repairs, including connection to wate pipe, flushing pipe, anti-syphonage pipe etc. and making good to floor complete all as specified and directed 2 Each
42 42 Dismantling Asbestos cement sheets (corrugated ,semi corrugated etc) in roof coverings incl rigdes etc complete. 80 Sqm
43 43 M&L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed. 80 sqm
44 44 M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete , sub base all as specified and directed 22.5 Cum
45 45 M & L 40 mm thick Cement Conrete1:2:4 type B–1 using 20mm graded stone aggregates in flooring laid in alternate panel of sizes as directed and finished even and smooth using extra cement all as specified and directed 300 Sqm
46 46 Supply only liquid water proofing compound 10 Litre
47 47 Dismantling/removing old damaged worn out APP of any thickness incl screed bed or plastering of any thickness and removing the rubish materials outside MOD land at a dumping place earmarked marked by any state govt/municipalities etc any distance complete. 800 Sqm
48 48 Material and labour, 15 mm thick cement plaster in CM (1:4) mixed with WPC as per manufacturer’s instructions @ 3% by weight of cement on concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately. 750 Sqm
49 49 Cutting groove in brick wall 75 mm wide and 65 mm deep for inserting APP polymer membrane and shaping horizontal face of groove with cement mortar 1:3, including removal of rubbish outside MoD land, complete all as specified. 45 RM
50 50 Material and labour, water proofing treatment of roof consisting as under:- (a) Applying a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of primer @ 0.30 litre/ sq.m including preparation of roof surfaces (b) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with flame (by torch application) all as per manufacturer’s instructions complete all as specified and directed. 750 Sqm
51 51 All as per Srl item No. 50 here-in-before but on vertical surfaces, using hot blown bitumen having penetration value 30/40 applied 1.20 Kg/ Sq.m over primer @ 0.30 litre/ Sq.m, complete all as specified and directed 50 Sqm
52 52 S&F in repairs vitreous china squating pan, 'Orissa' pattern, size 580x440mm white, with integral foot rests, including 100mm cast iron 'P' or 'S' trap and 100mm cast iron sanitary connection socket to fit WC outlet including connection to trap, to flushing pipe, anti-syphonage pipe etc. complete including making good to floor complete all as specified and directed. 5 Each
53 53 Supply and fix Vitreous China wash down water closet (pedestal pattern), white (excluding fixing bolts flushing cistern and flush pipe), fixed in repairs, including connection to wate pipe, flushing pipe, anti-syphonage pipe etc. and making good to floor complete all as specified and directed. 3 Each
54 54 S&F Rotational moulded polyethylene water storage tank 500 litres capacity, ISI marked triple layer construction (cylindrical vertical closed top), hoisted & fixed in position including S&F Ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 20mm bore GI pipe of having weight not less than 210gms including all fittings and gate valves with iron wheel head 20mm size, including taking down existing tank complete all as specified and as directed. 3 Each
55 55 S&F Rotational moulded polyethylene water storage tank 1000 litres capacity, ISI marked triple layer construction (cylindrical vertical closed top), hoisted & fixed in position including S&F Ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 20mm bore GI pipe of having weight not less than 210gms, including all fittings and 20mm size gate valves with iron wheel head including taking down existing tank complete all as specified and as directed. 3 Each
56 56 S & F in repairs 10 litres capacity, PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete all as specified and directed. 8 Each
57 57 S & F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified. 30 RM
58 58 S & F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified. 30 RM
59 59 S & F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified. 5 Each
60 60 S & F in repairs 75 mm bore PVC (SWR) bends any radius complete all as specified. 5 Each
61 61 S&F in repairs 15mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as directed 10 Each
62 62 S&F in repairs 20mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as directed by Engr in Charge. 10 Each
63 63 S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. 10 Each
64 64 S&F in repairs PVC Grating 100 mm dia with or without waste hole of brass chromium plated fixed on floor/ nahani trap with cement mortar, fixed in repairs, complete all as specified and directed. 10 Each
65 65 S & f in repairs bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified. 30 Each
66 66 S & F in repairs Pillar taps (Single Touch type), cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for 15mm bore iron pipe and pillar tab to be prior approval from Engr in Charge complete all as specified. 10 Each
67 67 S & F in repairs angle cock/stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 15 mm bore iron pipe or for brass ferrule complete all as specified. 10 Each
68 68 S & F in repairs stop valves, cast copper alloy, chromium plated, fancy type, with long shank and cup (concealed type), screwed down, high pressure, with crutch or butter fly handle, screwed both ends for 15mm bore iron pipe or for unions complete all as specified. 5 Each
69 69 Demolition of brick masonry built in cement mortar as in drain etc., complete all as specified. 4 Cum
70 70 M&L Brick masonry with sub class B bricks straight or curved on plan exceeding 6m mean radius, built in Cement Mortar (1:4) all as specified and directed. 4 Cum
71 71 S&F false ceiling with exposed GI system using “SILHOUETTE XL 15 mm (Nominal) designer Grid "Armstrong" white or Global white with black reveal and 600 x 600 x 15 mm thick prime fine fissured micro look white/coloured tiles (superfine 15mm/silhouette). Making necessary framework for AC ducting, if any and necessary cutouts for diffusers and light fittings, taping and finishing to proper line & level and incl dismantling old undervicable false ceilling complete all as per manufacturer’s instructions and as directed. 80 Sqm
72 72 M&L for averaging 3 mm thick putty and applying one coat of primer complete all as specified and directed 100 Sqm
73 73 Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each all as specified and directed 20 Each
74 74 Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each and all as specified and directed 20 Each
75 75 Taking down shutters of any description not exceeding 1.00 Sqm each all as specified and directed 12 Per leaf
76 76 Taking down shutters of any description exceeding 1.00 Sqm and not exceeding 2.0 Sqm all as specified and directed 10 Pear Leaf
77 77 S & F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part –I, Section 8, clause 8.20 (a) ; supplied and fitted to chowkats all as specified and directed 30.004 Sqm
78 78 S & F flush shutter 35mm thick solid core construction with block board core and plywood face panels commercial type on both sides with lipping / frame to match all as specified and directed 30.004 Sqm
79 79 M&L for Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded coloured PVC ’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single side prelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of single side prelaminated PVC sheet to be fitted in the MS frame welded/ sealed into the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying and fixing in the frame at site as per specification complete all as specified and as directed 25.998 Sqm
80 80 S&F Factory made PVC solid door frame of size 50 mm x 47 mm with wall thickness of 5 mm made out of 5 mm thick plain colour PVC sheet cut at corner and jointed with 02 Nos., 150 mm long brackets of size 15 mm x 15 mm mild steel square tubes 19 gauge including vertical door profiles reinforced with 19 mm x 19 mm steel square tube of 19 gauge (EPDM) rubber gasket weather seal provided throughout the frame and fixed to wall with 65/100 mm long mild steel screws through the frame by using PVC fasteners (minimum of 04 Nos. of screws to be provided for each vertical member & minimum 02 Nos. for horizontal member), complete all as specified. 97 RM
81 81 S & F mild steel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm long all as specified and directed 124 Each
82 82 S & F mild steel sliding door, bolts, plate type, stove enamelled black with bright bolt not less than 12mm bore, length of bolt 250mm all as specified and directed 36 Each
83 83 S & F mild steel, 300mm, ordinary rat rail rod pattern spring including roller and roller plate complete all as specified and directed 20 Each
84 84 S & F mild steel pressed handles oval type, stove enamelled black 125mm size all as specified and directed 124 Each
85 85 S & F SS butt hinges, medium weight 100mm size all as specified and directed 186 Each
86 86 S & F pressed steel door frames with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified size of frame 125 x 60mm all as specified and directed 30 RM
87 87 M&L Cement concrete 1:3:6 type C–1 filling of pressed steel frame and hold fast blocks etc all as specified and directed 0.5 Cum
88 88 Cutting hole in brick wall built in cement mortar exceeding half brick but not exceeding one brick and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, type B – 1 all as specified and directed 80 Each
89 89 S & F mild steel work for hold fasts,wall ties, ,bands, straps clamps, handles for manhole covers etc confirming to Fe- Fe 290grade- E165 all as specified and directed 50 Kg
90 90 Taking down old steel /wooden windows & M&L for factory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified. 20 Sqm
91 91 Taking down old steel /wooden windows & M&L for factory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and without glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified. 20 Sqm
92 92 S & F mild steel as in framed work as in doors or gates of angles or other section etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive for steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing incl MS hinges ,handles ms sheets 0.63 mm thick complete Fe 410-0 all as specified and directed 100 Kg
93 93 Material and labour, Gunniting to existing RCC Chajja, facia, parapet, beams, landings and similar RCC members after removing all loose concrete & preparations of surface, application of derusting chemical such as Dr Fixit Rust Remover or equivalent, welding additional bars/welded steel wire fabric if found necessary, priming reinforcement bars with a coat of zinc primer of coating not less than 40 micron, provision of bonding agent with bonding material like Dr Fixit bonding agent and repair to external RCC structure with slurry light and steel/ply form work and shortcrete concrete of mixed 1:3:1 (one part of cement, three part of coarse sand and one part of 10mm and down aggregate) of minimum 50mm thick incl plastering 5 mm thick in CM mortar 1:3 all as specified in IS 9012-1978 (all priming and bonding epoxy based paint shall be of Dr Fixit epoxy zinc primer or equivalent) etc complete all as specified and directed, as below:- Note(s) : 1. The rates include for necessary formwork and scafolding etc. 2. Reinforcement and welded steel wire fabric will be measured and paid separately. 300 Sqm
94 94 Supply only TMT steel bars for reinforcement in required length and dia, complete all as specified and directed. 100 Kg
95 95 Supply only welded steel wire fabric, weight not exc 4kg/sqm, complete all as specified and directed. 750 Kg
96 96 S&F powder coated aluminium frame work for doors, windows,partition s etc incl grill for windows for windows etc with one or more rebated section incl jointing cleats for fixing etc complete complete. 50 Kg
97 97 S&F powder coated anodised aluminium door shutters, partition wall, aluminium section weighting 0.55 Kg/Rm incl necessary joining cleats glazing clips rubber neoprene packing, handles two Nos in each door, hinges anodised aluminium snap beading screws etc complete all as specified and as directed. 15 Sqm
98 98 S&F powder coated anodised aluminium window and ventilator shutters , side hung type without sash bars aluminium section weighting 0.55 Kg/Rm incl necessary joining cleats glazing clips rubber packing, aluminium anodised snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1Nos0, hinges type B-21 100 mm long(2Nos) suitable handles (1Nos)complete all as specified and as directed. 15 Sqm
99 99 S&F 12 mm thick prelaminated board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to aluminium frame work complete.all as specified and directed 10 Sqm
100 100 S&F 5.5 mm thick selected quality tinted sheet glass and glazing clip in square fixed with PVC/neoprene gasket in aluminium frame work compelte. all as specified and directed 10 Sqm
101 101 S&F double action floor spring hydraulic regulated made up of min 1.25 mm thick aluminium sheet foundation box, main body with stainless steel cover, govering pivets made of brass, other part made up of mild steel heavy duty complete. all as specified and directed 3 Each
102 102 S&F brass six lever dead lock suitable for aluminium doors manufactured by Harrison Locks or Godrej as approved 3 Each
103 103 Taking down aluminium door shutter of any size upto 4 Sqm each and replacement of defecting pivot with new pivot & refixing in position complete all as specified and directed 5 Each
104 104 Taking down aluminium door shutters of any size upto 4 Sqm each replacement of defecting floor spring with new floor spring make : Amar/Sandhu. 5 Each
105 105 S&F in repair dead lock 6 lever brass for aluminium door shutter complete all as specified and directed 5 Each
106 106 Taking down old broken glass from aluminium door, window or partition panel by removing glass clips and S&F glass ordinary 5.0mm thick in any size and refixing the glass clips in position after replacing rubber gasket complete all as specified and directed 5 Each
107 107 S&F in repair Hydraulic door closer for aluminium door shutter complete all as specified and directed 5 Each
108 108 Material and labour, 18-20 mm thick machine cut kota stone slab as in flooring, steps of stair(treads), set with neat grey cement slurry @ 3Kg/Sqm, laid over and including 20mm thick cement and sand mortar (1:6) screed bed/bedding layer, jointed with grey cement slurry mixed with pigment to match the sahde of the slab including rubbing and polishingincl dismantl ing damaged stone slab of any description complete all as specified 50 Sqm
109 109 Material and labour, machine cut kota stone slab 18-20mm thick as in skirting/dado, riser of steps, laid over and including 10mm thick backing coat in CM (1:4), set in neat grey cement slurry @ 3Kg/Sqm, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed. 5 Sqm
110 110 Hacking out old broken glass (any thickness size, quality or description) from wooden/ steel frames, glazed with putty or fixed with wooden beads/ metal pins complete all as specified and as directed. 30 Sqm
111 111 S & F 3mm thick Sheet glass ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane, complete all as specified. 25 Sqm
112 112 S & F 3mm thick figured glass, pin headed type and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane, complete all as specified. 5 Sqm
113 113 Taking down old steel windows & S&F ECO-4000 Series windows/ventilators (Double rebate) fabricated from roll framed sections made of galvanized steel colour coated/powder coated ( Base steel as per IS 513"D" quality galvanized as per IS 277 with Zinc of 120gms/Sqr.mtr) with total coated thickness of 0.6mm and section of frame should be of 72mm x 55mm ,section for mullion should be of 72mm x 50mm, section for shutter frame should be of 47mm x 20mm, section for fixed glass bead should be of 12mm x 12mm and section for fly mesh should be of 40mm x 20mm, coated section should be with primer coat of Epoxy primer of 5-7 microns thick,finish painted with polyester paint of 12-16 microns thick or powder coated with pure polyester upto to 50-60 microns thick including 5mm thick plain glass, stainless steel 32 gauge fly mesh of 304 grades with 144 holes per square inch and Grill made of 10mm Sq MS bars welded to at 150mm centre to centre, 6mm x 12mm MS flat (total grill unit should be powder coated and fixed to window frame with screws). (a) FIXING DETAILS :- Section for frame Glazed shutters and Mesh shutters should be cut to length and miter joined with polypropylene corner brackets,mullion section should be joined with Frame/Mullion using Mullion Cap ethyl propylene damein monomer (EPDM) gasket should be used all around glass in shutter and fixed glass,rubber Gasket should be used around glass in shutter and fixed glass.Rubber gasket should be used around fly mesh to fix mesh in mesh shutter. (b) ACCESSORIES :- Each glazed shutter and mesh shutter should be provided with SS pivot hinges - 1 set, seccolor handle & seccolor stay. Window frame should be fixed to brick/concrete masonry by using Nylon self expanding caps and driving MS electroplated 80mm long screws into the caps through frame. Make :- NCL alltek and seccolor Ltd, Ashish Industries and Eqivalent. 15 Sqm
114 114 Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition), complete all as specified. 1 Cum
115 115 M&L for providing precast reinforcement cement concrete (1:2:4) type B-1 using 20mm graded aggregate in man holes covers slabs/ Shelves as in slabs supported on walls, beams and columns, in floors, roofs, landings, deck slabs and in shelves and like including necessary form work, complete all as specified and directed 1 Cum
116 116 Preparation of new wooden surfaces & applying two coats of synthetic enamel paint over a coat of pink primer to wood surfaces over 10 cm in width or girth not otherwise described, complete all as specified. 50 Sqm
117 117 Preparation of new steel surfaces & apply 2 coat of synthetic enamel paint over a coat of red oxide over 10cm in width or girth not otherwise described, complete all as specified. 30 Sqm
118 118 Applying two coats of exterior acrylic emulsion (weather proof treatment ), over a coat of primer in , over new plastered surfaces , including preparation new surfaces , complete all as specified and directed 300 Sqm
119 119 S&F in repairs mild steel framed work such as grills, gratings, cooler stand, brackets for sunshed etc with end bars of shouldered and or riveted or gorged into spikes, framed guard bars, barred iron doors, ladders frmamed balusters, walkways, rialings and similar work confirming to Fe-290 Gde E-165 complete. 150 Kg
120 120 E/M WORKS\nTaking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed. 648 Each
121 121 M & L for replacement of concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :-
122 121.01 One light / fan point controlled by one way switch 200 Per Point
123 121.02 One 5 Amp socket outlet on independent board. 30 Per Point
124 121.03 One 5 Amp socket outlet on same board. 10 Per Point
125 121.04 One bell/buzzer point controlled by one bell push 1 Per Point
126 121.05 One light point controlled by two 2-way switch 2 Per Point
127 122 All as per above item No 121 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed. 30 Per Point
128 123 M&L for replacement of point wiring in casing caping on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including PVC conduit , with mild steel terminal boxes (not less than 1.6 mm thick ) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :-\n
129 123.01 One light / fan point controlled by one way switch 150 Per point
130 123.02 One 5 Amp socket outlet on independent board. 20 Per point
131 123.03 One 5 Amp socket outlet on same board. 10 Per point
132 123.04 One bell/buzzer point controlled by one bell push 1 Per point
133 123.05 One light point controlled by two 2-way switch 2 Per point
134 124 All as per above Item No 123 here in befor but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed. 20 Per point
135 125 M & L for replacement of point wiring in existing conduit (PVC/Steel) surface / concealed including existing MS Terminal boxes with 1.5 sqmm FRLS PVC insulated multi stranded copper conductor cable single core 1100 volts grade and one run of 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire and laminated sheet cover 3 mm thick on terminal box duly fixed including taking out old u/s wire of any type and size complete all as specified and as directed for the followings :-
136 125.01 One light / fan point controlled by one way switch 100 Per point
137 125.02 One 5 Amp socket outlet on independent board. 50 Per point
138 125.03 One bell/buzzer point controlled by one bell push 2 Per point
139 126 Ditto all as per above item no 125 but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant ( FRLS ) cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed. 20 Each
140 127 S&F in replacement switch piano type 5 amp one way ISI Marked complete all as specified and directed 540 Each
141 128 S&F in replacement switch piano type15 Amps one way ISI Marked complete all as specified and directed 50 Each
142 129 S&F in replacement socket outlet 3 pin 5 Amps flush type complete all as specified and directed 100 Each
143 130 S&F in replacement socket outlet 2-in-1, 3 pin 5 amp and 15 amps all as specified and directed. 50 Each
144 131 S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed. Make : 1.Carb tree,2. Roma, 3.Havells 20 Each
145 132 S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed.Make : Make : 1.Carb tree,2. Roma, 3.Havells 20 Each
146 133 S&F in replacement switch 6 amps modular type one one way complete all as directed.Make :Make : 1.Carb tree,2. Roma, 3.Havells 30 Each
147 134 S&F in replacement switch 16 amps modular type one one way complete all as directed.Make :Make : 1.Carb tree,2. Roma, 3.Havells 20 Each
148 135 S&F in replacement electronic fan regulator Step type complete all as specified and directed.Make-1.Carb tree,2. Hager, 3.Havells 20 Each
149 136 S&F in replacement bell push flush type 5 amp one way ISI Marked complete all as specified and directed. 2 Each
150 137 S&F in replacement modular type bell push 6 amp one module ISI Marked complete all as specified and directed. 2 Each
151 138 S&F in replacement Bell, DING DONG AC 230 Volts single pole type complete all as specified and as directed. \n 5 Each
152 139 S & F in replacement of Lamp holder bakalite type with back plate suitable for batten fittings complete all as specified as directed 10 Each
153 140 S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed. 150 Each
154 141 S&F in replacement of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser including all accessaries all as specified and directed. Make:- 1. Havells Cat No LUMILINEPLUSBS20WLED865SPCSS , 2.Halonix cat no HLB-03-20-CW or equivalent in Crompton. 150 Each
155 142 S&F in replacement of enviroment friendly indoor decorative 10 Watt LED mirror light polycarbonate Batten with opal diffuser including all accessaries all as specified and directed. Make:- 1. Havells Cat No LUMILINEPLUSBS10WLED865SPCSS or equivalent in Halonix and Crompton. 20 Each
156 143 S & F in replacement of sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn into existing / new conduit of any size and type / casing-caping with and including one run of 2.5 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.\nNote: (i) New conduit/ casing- caping and accessories shall be measured separately. \n(ii) Two runs of 4.0 sqmm cable and one run of 2.5 sqmm cable of earth continuity conductor shall be a unit length. 50 RM
157 144 S & F in replacement of sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn into existing / new conduit of any size and type / casing-caping with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.\nNote: (i) New conduit/ casing- caping and accessories shall be measured separately. \n(ii) Two runs of 6.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor shall be a unit length. 50 RM
158 145 S & F in replacement of Regid non-metallic PVC conduit 25 mm (external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and as directed. 30 RM
159 146 S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V complete all as specified and as directed . 5 Each
160 147 S&F in replacement of sheet metal enclosure double door suitable for SPN distribution boards when MCBs to be used having 200Amp rated bus bar 8 ways 240 V complete all as specified and as directed. 10 Each
161 148 S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V complete all as specified and as directed . 5 Each
162 149 S&F in replacement of single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB 25Amp complete all as specified and as directed. 40 Each
163 150 S&F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified. 130 Each
164 151 S&F in replacement MCB SPN 5 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified. 17 Each
165 152 S&F in replacement MCB SPN 50 to 63 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified. 3 Each
166 153 S&F in replacement of 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm GI suspension wire one twin core cable flat or circular of size 10 Sq mm to be connected to existing MCB box / Main switches complete all as specified as dircted. 100 RM
167 154 S & F In replacement of modular switch 2 way, 6 Amp,1 module ISI Marked complete all as specified and as directed. 2 Each
168 155 S & F in replacement of modular Fan Regulator fan step regulator,120W-2 module ISI Marked complete all as specified as as directed. 10 Each
169 156 S & F In replacement of Piano type switch 2 way, 5 Amp,1 module ISI Marked complete all as specified and as directed. 4 Each
170 157 S&F in replacement of modular blanking plate, 1 module ISI Marked complete all as specified and as directed. 10 Each
171 158 S&F in replacement metal flush box 1 module all as specified and directed. 3 Each
172 159 S&F in replacement metal flush box 3 module all as specified and directed. 5 Each
173 160 S&F in replacement metal flush box 6 module all as specified and directed. 5 Each
174 161 S&F in replacement metal flush box 8 module all as specified and directed. 3 Each
175 162 S&F in replacement metal flush box 12 module all as specified and directed. 2 Each
176 163 S&F in replacement for white cover plate with frame, 1 module all as specified and directed. 3 Each
177 164 S&F in replacement for white cover plate with frame, 3 module all as specified and directed. 5 Each
178 165 S&F in replacement for white cover plate with frame, 6 module all as specified and directed. 5 Each
179 166 S&F in replacement for white cover plate with frame, 8 module all as specified and directed. 3 Each
180 167 S&F in replacement for white cover plate with frame, 12 module all as specified and directed. 2 Each
181 168 S&F in replacement of Hylem sheet 12"x15" complete all as specified and as directed. 5 Each
182 169 S&F in replacement of Hylem sheet 8"x5" complete all as specified and as directed. 15 Each
183 170 S&F in replacement of Hylem sheet 5"x5" complete all as specified and as directed. 5 Each
184 171 S&F in replacement of MS Box 10"x12"x3" complete all as specified and as directed. 5 Each
185 172 S&F in replacement of MS Box 7"x4"x3" complete all as specified and as directed. 10 Each
186 173 Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed. 2 Each
187 174 Supply and fix in replacement double door TPN DBs four way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site required complete all as specified and directed . 5 Each
188 175 S & F in replacement with MCB TPN 32 amps 10 KA ,B-series including connection with suitable size aluminium / copper lugs complete all as specified and directed . 2 Each
189 176 S & F in replacement with MCB TPN 50 to 63 amps 10 KA ,B-series including connection with suitable size aluminium / copper lugs complete all as specified and directed . 2 Each
190 177 S & F in replacement with MCB TPN 100 amps 10 KA ,B-series including connection with suitable size aluminium / copper lugs complete all as specified and directed. 1 Each
191 178 Supply laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 35 Sqmm nominal cross section 3.5 core complete all as specified and directed 100 RM
192 179 S & F in replacement enviroment friendly recess/pendent mounting LED flat panel 2'x2' fabricated CRCA sheet steel housing cool white with high efficient LEDs & glare free opal diffuser (34 W) PF>0.95 driver life >25000 Hours, operating range 140v to 280 V including all accessaries all as specified and directed. Make-:1.Havells cat part No - PLUTONE2X2PLR34WLED840S, equivalent in philips , Halonix 5 Each
193 180 Taking down electric energy meter of any size and type and deposite to MES store yard complete all as specified and directed. 24 Each
194 181 Supply and fixing in replacement microprocessor based three phase electronic tamper proof energy meter of rating 10 to 40 Amps, AC 415 Volts, 50 Hz covered with toughened glass cover with optical comunication port confirming to IS 13779 complete all as specified and directed 8 Each
195 182 Supply and fixing in replacement microprocessor based single phase electronic tamper proof energy meter of rating 10 to 60 Amps, AC 240 Volts, 50 Hz covered with toughened glass cover with optical comunication port confirming to IS 13779 complete all as specified and directed 8 Each
196 183 Supply and fixing in replacement microprocessor based single phase electronic tamper proof energy meter of rating 10 to 40 Amps, AC 240 Volts, 50 Hz covered with toughened glass cover with optical comunication port confirming to IS 13779 complete all as specified and directed 8 Each
197 184 Taking down old metallic energy meter box of any size and type complete all as specified and directed. 10 Each job
198 185 S&F in replacement of Energy meter Box Flame retardent polycarbonate body including all fixing arrangement like DIN rails mounting plate connection boxes fastning screw protection plate extra suitable to accomodate 3 Phase energy meter. the meter box shall be of SIze 450x300x214mm with locking arragement complete all as specified and directed. 5 Each
199 186 -Ditto- all as per Item No 185 Above But to acoomodate single phase energy meter of Size 300x300x170mm complete all as specified and directed. 5 Each
200 187 S&F sheet metal enclosure VTPN DBs 4 way Double door 415 volt concealed suitable for distribution boards when MCB to be used having 200 Amp rated bus bar complete including MCCB 100 Amp ,25 KA ,4 pole , with fixed thermal and magnetic release as incomer and MCB 6-32 Amp,10 KA -12 Nos as outgoing all as specified and as directed . 2 Each
201 188 Excavating of soft / disintegrated soil in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for under ground cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out of disintegrated rock complete all as specified and directed . 16.2 cum
202 189 Excavating of hard and dense soil in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for under ground cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting in any type of soil complete all as specified and directed . 5.4 cum
203 190 Returning, filling of hard and dense soil in including spreading , leveling , watering and well ramming in layers n. exc. 25 cm complete all as specified and directed . 12.14 cum
204 191 Removing excavated soft / disintegrated soil to a distance n.exc 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed . 9.46 cum
205 192 M & L sand cushioning to underground cables in layer ( 8 cm thick before laying of cables and 15cm thick after laying and stretching of cable ) in trenches for cable protection or under floor or in foundation complete all as specifed and directed . 6.48 cum
206 193 M & L for old size sub class 'B' bricks locally available best quality to be laid in trenches as protection of cable complete all as specified and directed . 695 Each
207 194 S & F Wall fan of single phase 230/240 V of size 400 mm sweep and grouting with nut , bolts & Fastenar on the wall and make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed by Engr-In - Charge. Make:Havells or equivalent Make of CG / Bajaj. 5 Each
208 195 Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated complete all as specified and directed. Make- Havells/halonix/usha 5 Each
209 196 Supply & fix exhaust fans heavy duty 300 mm dia 1400 RPM, 50 Hz 230 volt for domestic use,dynamically balance blade , epoxy powder coated confirm to IS 2312-1967 with ISI marking IP-55 with class B insulation motor including suitable size louver and all fixing accessories such as fastners nut bolts and electric connection with 3 core cable complete all as specified and directed. Make -Havells/crompton/ bajaj. 5 Each
210 197 S&F in replacement enviroment friendly,ultra modern,energy saving surface mounted decorative 10 Watt LED bulkhead fitting with pressure die cast aluminium housing ,high efficient LEDs with opal diffuser and IP65 protection all as specified and directed. Make-: 1. Havells cat no- RUGBYNEONFT10WLED860SSYMTOPCOR 2.Halonix cat no HLBH-02-10-CW,Equivalent in Philips, 5 Each