}

Improvement Of Sports Facility At Gauhati University ( Multipurpose Indoor Hall ) ( A ) Providing Electrification And Sports Lighting Works Including Providing Insulation Panels Under The Existing Roof ( B ) Supply And Installation Of Bucket Chairs., Gauhati University-Assam

University Gauhati University-UGU has published Improvement Of Sports Facility At Gauhati University ( Multipurpose Indoor Hall ) ( A ) Providing Electrification And Sports Lighting Works Including Providing Insulation Panels Under The Existing Roof ( B ) Supply And Installation Of Bucket Chairs.. Submission Date for this Tender is 26-07-2021. Electrification Work Tenders in Gauhati University Assam. Bidders can get complete Tender details and download the document.




Tender Notice

28172232
Corrigendum : Improvement Of Sports Facility At Gauhati University ( Multipurpose Indoor Hall ) ( A ) Providing Electrification And Sports Lighting Works Including Providing Insulation Panels Under The Existing Roof ( B ) Supply And Installation Of Bucket Chairs.
Open Tender
Indian
Assam
Gauhati University
26-07-2021

Tender Details

Improvement Of Sports Facility At Gauhati University ( Multipurpose Indoor Hall ) ( A ) Providing Electrification And Sports Lighting Works Including Providing Insulation Panels Under The Existing Roof ( B ) Supply And Installation Of Bucket Chairs.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Jul-2021 Extension Notice Date 19-07-2021
2 19-Jul-2021 Extension notice Date 26-07-2021

Key Value

Document Fees
INR 2000 /-
EMD
INR 156969.0 /-
Tender Value
INR 78.48 Lakhs /-

BOQ Items

Name of Work:Improvement of Sports Facility (Multipurpose indoor hall) at Gauhati University (a) Providing Electrification and Sports Lighting Works including providing Insulation panels under the existing roof. (b) Supply and Installation of Bucket Chairs
Sl. No. Item Description
1ROOF TRUSS Providing, fitting, hoisting and fixing of roof trusses fabricated out ofcombination of anytwo or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
2PAINTING ON STEEL AND OTHER METAL SURFACE Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
3Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. b). High gloss(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
4Supplying and fixing of underdeck insulation with 12 mm thick Insulation sheet made of Class-O Nitrile rubber of density 40-60 kg/cum having one side pasted with aluminium foil with all the ancilliary material using low VOC adhesive complete as directed . The works to include removing and refixing of of roofing sheet witl all labour and materials complete as directed Make: Supreme INSUshield or equivalent
5POINT WIRING Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing "n" capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose(Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. Short point up to 3.00 metre. length.
6Medium point up to 6.00 metre. length.
7Long point up to 10.00 metre. Length.
8Wiring for twin control light point with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19 mm ISI marked casing "n" capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system, with 2 way 5/ 6 amp F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) . Long point up to 10.00 metre. Length.
9Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing "n" capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm.cable in flat 19 mm ISI marked casing "n" capping system.
10Wiring for drawing sub-main line with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surfaceflat 19 mm ISI marked casing "n" capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system, including connectionas required completeas directed and specified by the Deptt. With 3 x 1.5 sq. mm. cablein flat 19 mm ISI marked casing "n" capping system
11Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing "n" capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm.in flat 19 mm ISI marked casing "n" capping system.
12With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm.cablein flat 25mm ISI marked casing "n" capping system.
13With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in flat 25mm ISI marked casing "n" capping system.
14Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing "n" capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in flat 32 mm ISI marked casing "n" capping system.
15With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in flat 32 mm ISI marked casing "n" capping system.
16Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV GSolid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988 armoured U.G. cableU.G. cable laid in ground/partially in air (as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 3 & 1/2 Core A2XFY 25.00 Sq.mm.3 & 1/2 Core armoured U.G. cable
1770.00 Sq.mm.3 & 1/2 Core armoured U.G. cable
18300.00 Sq.mm.3 & 1/2 Core armoured U.G. cable
19SUPPLYING FITTING AND FIXING OF (DOWELLS/ COMETmake) DOUBLE compression BRASS GLANDS WITH NICKEL - PLATED FLAMEPROOF (CBF) Size: 23.5 - 26, 1- 1/4 "
20WEATHERPROOF (CBW) Size: 26.5 - 30, 1- 1/2 "
21WEATHERPROOF (CBW)Size: 30.5 - 33, 1- 1/2 "
22Supply and fixing 32 mm dia 2.00mm average wall thicknessheavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed systemincluding cutting the wall and making good the same as required:
23Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessedsystem complete as per direction of department. 1-2 module type Metal
243 module type Metal
254-5 module type Metal
266-8 module type Metal
2710 module type Metal
2812-16 module type Metal
29Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department. 1 module
30Supplying with fitting and fixing of Foot lamp with Box and lamp holder in 3 module recessed system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. Without lamp.
31Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE complete as per direction of department.
32Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
33Supplying including installation of socket outlet 6 Amps 3 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
34Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
35Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
36Supplying including fitting and fixing of TV SOCKET, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO)including making necessary connection as per direction of department.
37Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 100 watt electronic modular 4 step speed control2 - module type
38Wiring for Co - axial Jelly Flooded (Unarmoured) (FINOLEX /RR KABEL /NICCO / ANCHOR make) cable in existing surface conduit wiring system including connection etc as required. Co - axial Jelly Flooded (Unarmoured) RG 6 (Copper)
39ITEM OF MAIN DISTRIBUTION BOARD AND MAIN LT PANEL WORK CARRIED OVER TO SUMMERY OF ELECTRICAL WORKS Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hagermake) 6 to 32A
40Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series(ABB, Schneider MG, legrand, Hagermake) 40A
41Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hagermake) 40A
42Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hagermake) 40A
43Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DPRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity DP RCCB (Schneider neo break, C&S, Havells, Indo Asian, HPL, V-Guard or equivalent make as approved by the Deptt.) 40A
44MCCB with Thermal & Magnetic Release Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian make) 63A
45Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake) 8 way SPN double door
4612 way SPN double door
47Supplying with fitting and fixing sheet steel, phosphatised, powder painteddust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake) 4 way TPN (4+12)double door
488 way TPN (4+24)double door
49Supplying with fitting and fixing MCCB income and MCB outgoing sheet steel, phosphatised, powder painted double door IP-43 surface mounting vertical TPN MCB DB incorporated with bas-bar up to 250A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake) 4 way TPN (4+12)double door
508way TPN (4+18)double door
51Supplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt. 20A Capacity. (C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make)
52MAIN LT PANEL-[ MULTIPURPOSE HALL ] Supplying and installation of metal enclosed wall/floor mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). Panel should be made of sheet steel and thickness not less than 2mm and structural steel having light section. The panel shall be completely dust tight and vermin proof and shall be painted with anti corrosive and anti condensation type two coats of primer and two coats of paint. All wiring shall be PVC insulated and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of out going feeders from the bottom of the panel. The panel shall be incorporated with double busbar system. The bus bar shall be of high quality copper of uniform cross section. The panel shall consist of the following items (viz. Voltmeter, Ammeter, CT, indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel. (Contd....)
53a) 320 A ,4P, MCCB, 36 KA - 1 No. b) 160 A ,4P, MCCB, 25 KA - 1 No. c) 400 A, 4P, on-load Changeover switch - 1 No. d) Digital Ammeter - 2 Nos. e) Digital Voltmeter -2 Nos. f) CT 320/5-1 Sets. g) CT 160/5-1 Sets. h) Switch Fuse Unit - 6 Nos i) Selector Switch - 4 Nos j) LED Indicating Lamp 2 Sets k) Bus-Bars: 600 A TPN electrolytic "AL" Bus Bar of uniform cross-section (50mmx10mm) – 1 set l) 100 A 4P MCCB 25 KA – 3 Nos. m) 63 A 4P MCCB 25 KA – 3 Nos. n) 63 A TP MCB– 2 Nos. o) 40 A TP MCB– 6 Nos. P) 40 A DP MCB– 3 Nos.
54LIGHT FIXTURES ITEMS APPROVED BY THE CHIEF ENGINEER P.W.D. (Bldg.), ASSAM, CHANDMARI, GUWAHATI-3ON DATED 09-09-2019 Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department. b) BN021C LED 20 PSU CW GR S2 [TL]
55Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department. (C ) LGLZ0 1 X 010XC / LGLZ0 1 X 010XCN /LGLZ0 1 X 010XCW( 10 W) [FL]
56Supplying, installation, testing and Commission of the following indoor Decorative Recess mountedLEDdown lighter luminaries of model no-DN 393 B LED 12 S-6500 PSU WH / D01257R000 / D01240R000 /D01230R000/ CRDL11R017HP57 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Jaquar/ LT / Wipro make). [CL]
57Supplying, installation, testing and Commission of the following indoor Decorative Recess mountedLEDdown lighter luminaries of model no-DN 394B LED 16 S -6500 PSU WH / MV1857RLOO / MV1840RLOO /MV1830RLOO / MV1830RLOO /MV1857R500 / MV1857R500 /MV1840RLOO / CRDL11R023HP57complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / LT / Wipro make). [CLT]
58Supplying, installation, testing and Commission of the following indoor Integral flood light with driver inside a PDC housing suitable for Sports Arrena,it is highlyefficient,reliable and sturdy, mounted on frame at the ceiling luminaries of make:- PHILIPS model no.-Philips BVP483 P LED235 CW SMB PSU P4144complete with all accessoriesetc. In theceilingmounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / LT / Wipro make). [FDL]
59Supplying including fitting fixing of followingstar rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable,as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make) Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
60Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1400 mm Sweep. (ORIENT PSPO make) /Premium model 1400 mm Sweep SS-390 Deco. Havells make)
61Supplying including fitting fixing of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Ventil Air DB 300 mm sweep (Havells make)
62Supplying including fitting fixing of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Heavy Duty 450 mm sweep 900 RPM Single phase (ORIENTmake)
63Supplying, installation of GI PERFORATED cable tray on wall or from ceiling including necessary channel, nuts and bolts, washer etc. as required as directed and specified by the department. (LEGRAND/ AKG/STRUTFASTmake). Size of Tray 152
64Size of Tray 228
65Size of Tray 304
66Inter/Exter Bend 152
67Inter/Exter Bend 228
68Inter/Exter Bend 304
692 KVA On-Line UPS System (Orion or equivalent make as approved by the Deptt.) with PWM-IGBT technology230V AC Input (160V – 280V A 1 Ph input- 1 Ph outputWith Isolation Transformer1.6KW output with 0.8 output PF30 min backup using SMF battery
70EARTHING AND LIGHTING CONDUCTOR Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipewith necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mmhinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
71Extra for using salt (5 Kand Charcoal (64 Kin pipeEarth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
72Supply, installation & testing of G.I. Plate earth station with600 mmx600 mmx6 mm heavy duty G.I. earth plate withnecessary 40 mm dia. G.I. watering pipewith G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mmhinged cover C.I. cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
73Extra for using salt (5 Kand Charcoal (96 Kin G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
74Supplying & laying of25X5mmsize G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
75Supplying & laying of 6 SWG G.I.. earth drawn through 15 mm dia. Medium quality G.I. pipe from Earth Electrode (below G.L.)to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
76Supply, fitting & fixingof Lighting Finial Arrestor made of 25 mm dia 300 mm long solid G.I. tube having 85 mm dia. single prong at top and 3 mm base plate at bottom complete with fitting & fixing with G.I. nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt.
77Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt.
78BUCKET CHAIRS Supplying and installation of standard size bucket chairs of colour and specification as per annexure
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail