| Name of Work: REPAIR & SERVICING OF CEILING FANS/SUMMER COOLING APPLIANCES UNDER AGE E/M-II OF GE(S) MEERUT CANTT | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Material and labour for opening servicing of ceiling fans of 1200/1400 mm, AC 230 volts including greasing, oiling, fitting/reassembling of fan including providing minor accessories like split pin, MS check nut and condensor holder, rubber reel of suitable size, MS nut bolt 50mm long 8mm dia, PVC flexible copper wire ,other parts if required shall be measured under respective supply only items of BOQ for making fan serviceable/ running condition complete all as specified and directed | BI01010001010000000000000515BI0100001112 | 700 | Each |
| 2 | 2 | Material and labour for servicing of ceiling fans including rewinding of burnt coils of ceiling fans with super enamalled copper winding wire of existing size for 1200 mm sweep , AC 230 volts including greasing, oiling, fitting/reassembling of fan including minor accessories like split pin, MS check nut and condensor holder, rubber reel of suitable size, MS nut bolt 50mm long 8mm dia , other parts if required shall be measured under respective supply only items of BOQ for making fan serviceable/ running condition including PVC flexible copper twin core 23/0.0076 size complete all as specified and directed. Make of winding wire:- ATLAS/HTP/BIC. Note for item No 1, 2 &3:- Re-winding & repair work will be carried out in AGE E/M-II (S) store yard. | BI01010001010000000000000515BI0100001113 | 1700 | Each |
| 3 | 3 | All as per item No 2.00 above but fans1400 mm sweep. Note: For item No 1, 2 & 3 :-(i)Spare parts shall be measured for supply only and paid separately under respective item of BOQ. (ii) The cost of labour for replacement of supply only items shall be deemed to be included in this item & nothing shall extra shall be paid. | BI01010001010000000000000515BI0100001114 | 200 | Each |
| 4 | 4 | Supply only Ball bearing of Size 6201 | BI01010001010000000000000515BI0100001115 | 480 | Each |
| 5 | 5 | Supply only Ball bearing of Size 6202 | BI01010001010000000000000515BI0100001116 | 300 | Each |
| 6 | 6 | Supply only Ball bearing of Size 6203 | BI01010001010000000000000515BI0100001117 | 150 | Each |
| 7 | 7 | Supply only Ball bearing of Size 6204 | BI01010001010000000000000515BI0100001118 | 100 | Each |
| 8 | 8 | Supply only Ball bearing of Size S-8 | BI01010001010000000000000515BI0100001119 | 100 | Each |
| 9 | 9 | Supply only Oil filled capacitor 2.5 MFD 230 Volts | BI01010001010000000000000515BI0100001120 | 3800 | Each |
| 10 | 10 | Supply only Oil filled capacitor 3.15 MFD 230 Volts | BI01010001010000000000000515BI0100001121 | 300 | Each |
| 11 | 11 | Supply only PVC canopies for ceiling fans upper / bottom, white / brown coloured as required at the site complete all as specified an directed. | BI01010001010000000000000515BI0100001122 | 900 | Each |
| 12 | 12 | Supply only blade for ceiling fan made out of alluminium heavy duty as per sample suitable for 1200 mm sweep ceiling fans for the make of ceiling fan Polar/Usha/Orient/Khaitan all as specified and directed. | BI01010001010000000000000515BI0100001123 | 480 | Set of three |
| 13 | 13 | All as per item No 12.00 above but for ceiling fan 1400 mm sweep. | BI01010001010000000000000515BI0100001124 | 50 | Set of three |
| 14 | 14 | Supply and fixing of ceiling fan BEE rating not less than 2 star rated power consumption not more than 50 Watts, white colour, 1200 mm sweep, copper winding, single phase, 220 volts, 50 Hz, with blade set of 3, with down rod as per site requirement including connection three core flexible copper wire 0.75 Sqmm or above multistranded from ceiling rose to fan connector complete all as specified and directed. Make - Havells, Model - ES 50 or equivalent in Crompton/Orient/Bajaj | BI01010001010000000000000515BI0100001125 | 53 | Each |
| 15 | 15 | Supply and fixing down rod (connected from fan hook to ceiling fan), made out of MS pipe medium grade of length as per site requirement of 15mm dia threaded /suitable Nos of drilled hole suitable for hanging the ceiling fans and including two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed. | BI01010001010000000000000515BI0100001126 | 100 | RM |
| 16 | 16 | Supply and fixing down rod made out of MS pipe 15mm dia medium grade lengtth not less than 450 mm long, threaded/suitable Nos of drilled hole suitable for hanging the ceiling fans including two coats of snthetic enamelled paint over a coat of red oxide primer complete all as specified and directed. | BI01010001010000000000000515BI0100001127 | 550 | Each |
| 17 | 17 | Supply and fixing of hanging clamp with rubber reel, nut bolts of suitable size & length as per site requirement and split pin complete all as specified and directed. | BI01010001010000000000000515BI0100001128 | 400 | Each |
| 18 | 18 | Material and labour for taking down the unserviceable ceiling fan of any size from site and depositing at AGE E/M store yard for rewinding including transportation as required complete all as specified and directed. | BI01010001010000000000000515BI0100001129 | 250 | Each |
| 19 | 19 | Supply and fixing of ceiling fan with ISI marked white colur, 1400mm sweep, copper winding, single phase, 220-240 volts, 50 Hz, with blade set of 3, with down rod as per site requirement including connection three core flexible copper wire 0.75 Sqmm and over multistranded from ceiling rose to fan connector etc. complete all as specified and directed. Make- Havells Model No- Velocity ES-50 or equivalent in Crompton/Orient/Bajaj | BI01010001010000000000000515BI0100001130 | 33 | Each |
| 20 | 20 | Material and labour for fixing the serviceable ceiling fan of any size at required place/site including transportation required all as specified and directed. | BI01010001010000000000000515BI0100001131 | 250 | Each |
| 21 | 21 | Material and labour for painting of ceiling fan including blades of any description and size by appyling one coat of synthetic enamel paint by spray painting with electric spray gun complete including writing MES Nos and preparation of surfaces complete all as specified and directed . | BI01010001010000000000000515BI0100001132 | 2600 | Each |
| 22 | 22 | Material and labour for cutting/lathe work of ceiling fan in lathe machine for conversion from bush to bearing, including necessary finishing etc complete all as specified and directed. | BI01010001010000000000000515BI0100001133 | 100 | Each Job |
| 23 | 23 | Material and labour for steel stator (armature) with shaft as per existing suitable for 1200mm sweep ceiling fan complete all as specified and directed. | BI01010001010000000000000515BI0100001134 | 160 | Each |
| 24 | 24 | Supply and fixing rotor (magnetic ring) as per existing suitable for 1200 mm sweep ceiling fan made of steel complete all as specified and directed | BI01010001010000000000000515BI0100001135 | 160 | Each |
| 25 | 25 | Supply and fixing upper/lower housing caps of ceiling fan suitable for 1200 mm sweep ceiling fan made of steel complete all as specified and directed. | BI01010001010000000000000515BI0100001136 | 160 | Each |
| 26 | 26 | Supply and fixing steped fan regulator ISI mark complete all as specified and directed Make Anchor/Cona/Plaza | BI01010001010000000000000515BI0100001137 | 200 | Each |
| 27 | 27 | Supply and fixing Modular type steped fan regulator 2 module complete all as specified and directed . | BI01010001010000000000000515BI0100001138 | 120 | Each |
| 28 | 28 | EXHAUST FAN : Material and labour for servicing of exhaust fan of size 450/400/300/250/230 mm Metal /PVC, AC 230 volts including greasing, oiling, fitting /reassembling of Exhaust fan including providing minor accessories like ,MS nut ,washer and MS bolt of required size as per site requirement and making exhaust fan in serviceable running condition complete all as specified and directed | BI01010001010000000000000515BI0100001139 | 38 | Each |
| 29 | 29 | Material and labour for servicing including rewinding of Exhaust fans burnt coils with super enamalled copper winding wire of existing size for exhaust fans 230 Volts 400/450 mm sweep, including minor accessories like MS screw of suitable size, MS nut bolt, PVC flexible copper wire etc required for making serviceable in running condition complete all as specified an directed. | BI01010001010000000000000515BI0100001140 | 50 | Each |
| 30 | 30 | All as per item No 29.00 above but 300 mm sweep. | BI01010001010000000000000515BI0100001141 | 80 | Each |
| 31 | 31 | All as per item No 29.00 above but 200/230 mm sweep. Note:- Re-winding & repair work will be carried out in AGE E/M-II (S) store yard. | BI01010001010000000000000515BI0100001142 | 35 | Each |
| 32 | 32 | Supply and fixing blade heavy duty (set of four blades) made of metal suitable for exhaust fans size 450/400 mm sweep with screw etc of any make as directed. | BI01010001010000000000000515BI0100001143 | 20 | Each |
| 33 | 33 | Supply and fixing fan blade set made of sheet metal three blades suitable for Exhaust fans 300 mm sweep with screw etc for any make of exhaust fans as per site requirement complete all as specified and directed . | BI01010001010000000000000515BI0100001144 | 35 | Each |
| 34 | 34 | Supply and fixing fan blade set made of sheet metal three blades suitable for Exhaust fans 200/230 mm sweep with screw etc for any make of exhaust fans as per sire requirement complete all as specified and directed . | BI01010001010000000000000515BI0100001145 | 40 | Each |
| 35 | 35 | Supply and fixing exhaust fan metal/PVC of all as size to fix at location given from sub divison includded all accessories required to fix the exhaust fan all as specified and directed incluidng required cementing work, finishing and piant to match the disturbed surface complete all as specified and directed.\n | BI01010001010000000000000515BI0100001146 | 80 | Each Job |
| 36 | 36 | Taking down exhaust fan (metal/PVC) of all size from the site as per complaint givenfrom subdivision and deposiyed to the store all as specified and directed. | BI01010001010000000000000515BI0100001147 | 80 | Each Job |
| 37 | 37 | Supply and fixing exhaust fan motor copper wounded 230 volts ,single phase 50 Hz, RPM not less than 1300 suitable for 200 to 250 mm sweep size metallic body exhaust fan complete all as specified and directed . | BI01010001010000000000000515BI0100001148 | 20 | Each |
| 38 | 38 | Supply and fixing exhaust fan motor copper wounded 230 volts ,single phase 50 Hz, RPM not less than 1300 suitable for 300 mm sweep size metallic body exhaust fan complete all as specified and directed . | BI01010001010000000000000515BI0100001149 | 30 | Each |
| 39 | 39 | Supply and fixing exhaust fan heavy duty motor copper wounded 230 volts ,single phase 50 Hz, RPM not less than 1300 suitable for 400 /450mm sweep size metallic body exhaust fan complete all as specified and directed . Make: Khaitan/Deuronn/Indo | BI01010001010000000000000515BI0100001150 | 25 | Each |
| 40 | 40 | Supply and fixing exhaust fan frame/budy of metal suitable for 450/400mm sweep matal body exhaust fan including all accessories to fix the moto with frame complete all as specified and directed . | BI01010001010000000000000515BI0100001151 | 22 | Each |
| 41 | 41 | Supply and fixing exhaust fan MS frame/body including legs, nut and bolts of suitable size suitable for 300 mm sweep metal body exhuat fan including all accessories to fix the motor with frame complete all as specified and directed. | BI01010001010000000000000515BI0100001152 | 28 | Each |
| 42 | 42 | Supply and fixing exhaust fan MS frame/body including legs, nut and bolts of suitable size sultable for 230 to 250 mm sweep metal body exhaust fan including all accessories to fix the motor with frame complete all as specified and directed. | BI01010001010000000000000515BI0100001153 | 10 | Each |
| 43 | 43 | Supply and fixing PVC exhaust fan frame complete sultable for 230 to 250 mm sweep fresh air fan made of PVC complete all as specified and directed . | BI01010001010000000000000515BI0100001154 | 20 | Each |
| 44 | 44 | All as per item No 43.00 above but suitable for 180 to 200mm sweep fresh air fan made of PVC. | BI01010001010000000000000515BI0100001155 | 10 | Each |
| 45 | 45 | Supply and fixing motors 230/250mm sweep suitable for PVC fresh air fan 230 volts single phase 50 Hz, marked complete all as specified and directed by Engr-in-Charge. | BI01010001010000000000000515BI0100001156 | 40 | Each |
| 46 | 46 | Supply and fixing motors 180/200mm sweep suitable for PVC fresh air fan 230 volts single phase 50 Hz, marked complete all as specified and directed by Engr-in-Charge. | BI01010001010000000000000515BI0100001157 | 10 | Each |
| 47 | 47 | Supply and fixing of louver shutter for exhaust fan of size 450/400mm made of GI sheet duly painted including fixing arrangement and fixing material complete all as specified and directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001158 | 10 | Each |
| 48 | 48 | Supply and fixing of louver shutter for exhaust fan of size 300/230/220mm made of GI sheet duly painted including fixing arrangement and fixing material complete all as specified and directed . | BI01010001010000000000000515BI0100001159 | 10 | Each |
| 49 | 49 | Supply and fixing front grill of metal suitable for metal body exhaust fan of 300/250/230/200 mm sweep complete all as specified and directed. | BI01010001010000000000000515BI0100001160 | 10 | Each |
| 50 | 50 | Material and labour for painting of Exhaust fan including blades of any description by appyling one coat of synthetic enamel paint complete including writing MES Nos and preparation of surfaces all as specified and directed . | BI01010001010000000000000515BI0100001161 | 120 | Each |
| 51 | 51 | Supply and fixing Exhaust fan legs made of metal including MS nut, bolts,washers suitable for 450/400/300/230/200 mm sweep metal body exhaust fan complete all as specified and directed. | BI01010001010000000000000515BI0100001162 | 50 | Set of four |
| 52 | 52 | Material and labour servicing including rewinding of wall mounting / cabin fans burnt coils with super enamalled copper winding wire of existing size AC 230 Volts of any size / sweep, complete including greasing , oiling and minor accessories and making serviceable in running condition complete all as specified an directed. | BI01010001010000000000000515BI0100001163 | 20 | Each |
| 53 | 53 | Supply and fix wall fan 400 mm sweep copper wound with pull cord to control speed and oscillation,three blades,230 volts,50 Hz ,speed not less than 1300 RPM, air delivery not less than 70 CMM, including all accesories for fixing it on wall complete all as specified and directed . Make - Havell's/Orient/Crompton/USHA | BI01010001010000000000000515BI0100001164 | 5 | Each |
| 54 | 54 | WINDOW TYPE AC/SPLIT AC: Material and labour for Servicing of window / split type AC of any capacity and make including washing condensor, cooling unit, cleaning of air filter and refixing the same after repair including testing and commmissioning complete all as specified and directed. Note :- (i)spare /defective parts shall be measured for supply only and paid separately under respective item of BOQ. (ii) The cost of labour for replacement of supply only items shall be deemed to be included in this item & nothing shall extra shall be paid.\n | BI01010001010000000000000515BI0100001165 | 45 | Each |
| 55 | 55 | Supply only starting capacitor 100/120 MFD complete all as specified & directed . | BI01010001010000000000000515BI0100001166 | 7 | Each |
| 56 | 56 | Supply only starting capacitor 120/150 MFD complete all as specified & directed . | BI01010001010000000000000515BI0100001167 | 7 | Each |
| 57 | 57 | Supply only capacitor 36 MFD for window type AC complete all as specified & directed . | BI01010001010000000000000515BI0100001168 | 7 | Each |
| 58 | 58 | Supply only running capacitor 50-60 MFD for window type AC/split type AC complete all as specified & directed . | BI01010001010000000000000515BI0100001169 | 7 | Each |
| 59 | 59 | Supply and fixing starting relay suitable for window type AC for any capacity specified & directed by Engr-in-Charge | BI01010001010000000000000515BI0100001170 | 6 | Each |
| 60 | 60 | Supply and fixing fan blade of compressor cooling fan of split type AC indoor unit for any type complete all as specified & directed . | BI01010001010000000000000515BI0100001171 | 4 | Each |
| 61 | 61 | Supply only fan blade of blower fan of split type/window AC for any capacity complete all as specified & directed . | BI01010001010000000000000515BI0100001172 | 4 | Each |
| 62 | 62 | Supply only condensor coil for 1.5 ton/ 2 Ton window type AC/ Split Type AC complete all as specified & directed . | BI01010001010000000000000515BI0100001173 | 3 | Each |
| 63 | 63 | Supply only remote control unit of suitable capacity of split type AC/ Window Type AC complete all as specified & directed . | BI01010001010000000000000515BI0100001174 | 4 | Each |
| 64 | 64 | Supply only Air filter made of PVC/Nylon fiber suitable for 1.5 / 2 Ton split type AC complete all as specified & directed . | BI01010001010000000000000515BI0100001175 | 14 | Each |
| 65 | 65 | M&L for rewinding of blower motor single phase of any make size and type using super enamel copper wire of existing size including replacement of other accessories like gun metal bushes or ball bearing and other items for any type AC 1.5/2 Ton capacity complete all as specified & directed by Engineer-in-Charge.\n | BI01010001010000000000000515BI0100001176 | 5 | Each |
| 66 | 66 | M&L for replacement of complete wiring kit of window type AC/Split Type AC 2/1.5 Ton capacity complete all as specified & directed . | BI01010001010000000000000515BI0100001177 | 5 | Each |
| 67 | 67 | Supply and fixing indoor unit complete with cooling coil,PCB circuit, Remote sensor ,swing motor with blades, rotary motor with shaft & fins & including all accessories suitable for split type air conditioner of capacity 1.5/2 Ton minimum 3 star rated as per site requirement including all fixing accessories complete all as specified and directed. Make:- Hitachi/Daikin/Blue Star/ LG/ Carrier/ Philips | BI01010001010000000000000515BI0100001178 | 3 | Each |
| 68 | 68 | Supply and fixing compressor cooling motor copper wounded suitable size for air conditionsers 1.5 / 2 Ton capacity as per site requirement all as specified and directed . | BI01010001010000000000000515BI0100001179 | 4 | Each |
| 69 | 69 | Taking down carefully the hermetically sealed compressor unit from window /Split type Air conditioner 1.5 ton and replacing it with new compressor (reciprocating/rotory/scroll) as per Make and model of AC at site and gas charging complete in all respect and testing at required pressure after re-installing at site including replacement of mounting rubber bushes, nut bolts etc and testing after installation complete all as specified and directed . Make: Tecumsha/Emerson/Samsung\nNote : Gas charging with refrigerant R-22 of Air conditioner will be measured & paid separately under relevant item. | BI01010001010000000000000515BI0100001180 | 6 | Each Job |
| 70 | 70 | All as per item No 69.00 but for 2 Ton capacity. | BI01010001010000000000000515BI0100001181 | 2 | Each Job |
| 71 | 71 | Supply and fixing outdoor unit with copper condenser coil, fan motor with blades,brass valves for inlet & outlet, wiring circuit, filters etc and all accessories,suitable for minimum 3 star rated split type air conditioner of capacity 1.5/2 Ton for any make as per site requirement either for inverter type/ non inverter type complete all as specified and directed . Make: Hitachi/Daikin/Blue Star/LG | BI01010001010000000000000515BI0100001182 | 3 | Each |
| 72 | 72 | Supply and fixing MS bracket suitable for fixing window type AC/ Split type AC (for Out door Unit) including nut and bolts etc required as per site complete all as specified and directed. | BI01010001010000000000000515BI0100001183 | 4 | Each Set ot Two |
| 73 | 73 | Supply & fix in replacement metal plug top 20 to 32 Amps for AC complete all as specified and directed . | BI01010001010000000000000515BI0100001184 | 20 | Each |
| 74 | 74 | Supply & fix in replacement metal plug socket 20 to 32 Amps for AC complete all as specified and directed . | BI01010001010000000000000515BI0100001185 | 20 | Each |
| 75 | 75 | Material and labour for Charging of gas R-22 type in AC with required quantity after testing flushing complete system against leakage including stopping of leakage if found any complete all as specified & directed. | BI01010001010000000000000515BI0100001186 | 35 | Kg |
| 76 | 76 | Supply and fixing single phase motor starter 25 A,240 volt AC ,50 Hz suitable for air conditioner as per site requirement complete all as specified and directed . Make- Simon model-HMWAM020./ Indoasian/ Legrand | BI01010001010000000000000515BI0100001187 | 30 | Each |
| 77 | 77 | Supply and fixing PCB for Indoor unit of air conditioner of any make suitable for 1.5/2 TON AC as per site requirement complete all as specified and directed. | BI01010001010000000000000515BI0100001188 | 3 | Each |
| 78 | 78 | Supply and fixing PCB for outdoor UNIT of air conditioner of any make suitable for 1.5/2 TON AC as per site requirement complete all as specified and directed. | BI01010001010000000000000515BI0100001189 | 2 | Each |
| 79 | 79 | Supply and fixing AC remote as per site requrement comple all as specified and directed. | BI01010001010000000000000515BI0100001190 | 5 | Each |
| 80 | 80 | Supply and fixing PCB for window type air conditioner of any make suitable for 1.5/2 TON AC as per site requirement complete all as specified and directed. | BI01010001010000000000000515BI0100001191 | 2 | Each |
| 81 | 81 | WATER COOLERS : Material & labour for Repair/servicing of water cooler including cleaning water tank with washing powder and fresh water for 40/ 80 to 150/180 Ltrs capacity complete all as specified and directed.Note for item No 81.00 ,replacement of defective parts shall be measured and paid separately under respective item of BOQ. | BI01010001010000000000000515BI0100001192 | 25 | Each |
| 82 | 82 | Supply & fixing starting relay suitable for water coolers of any capacity as per site requirement complete all as specified and directed . | BI01010001010000000000000515BI0100001193 | 10 | Each |
| 83 | 83 | Supply & fixing starting capacitor 40-60 MFD suitable for water cooler complete all as specified and directed . | BI01010001010000000000000515BI0100001194 | 12 | Each |
| 84 | 84 | Supply & fixing starting capacitor 100-120 MFD suitable for water cooler complete all as directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001195 | 8 | Each |
| 85 | 85 | Supply & fixing PVC drain pipe of water coolers of size not less than 25 mm in dia, superior quality complete with GI clamps all as directed . | BI01010001010000000000000515BI0100001196 | 50 | RM |
| 86 | 86 | Supply & fixing overload relay of water cooler of any capacity 40/80 ltrs and 150/180 ltrs complete all as specified and directed . | BI01010001010000000000000515BI0100001197 | 12 | Each |
| 87 | 87 | Supply & fixing running capacitor 10 MFD for water cooler complete all as specified and directed . | BI01010001010000000000000515BI0100001198 | 10 | Each |
| 88 | 88 | Supply & fixing running capacitor 25 MFD for water cooler complete all as specified and directed . | BI01010001010000000000000515BI0100001199 | 12 | Each |
| 89 | 89 | Supply & fixing running capacitor 36 MFD for water cooler complete all as specified and directed . | BI01010001010000000000000515BI0100001200 | 8 | Each |
| 90 | 90 | Supply & fixing condensor fan motor single phase complete of suitable size for water coolers 40/80 to 150/180 ltrs capacity including all accessories for fixing of fan complete all as specified and directed. | BI01010001010000000000000515BI0100001201 | 5 | Each |
| 91 | 91 | Supply & fixing thermostat suitable for any type of water cooler complete all as specified and directed . | BI01010001010000000000000515BI0100001202 | 8 | Each |
| 92 | 92 | Supply & fixing copper ccondensor coil suitable for water cooler of capacity 40/80 ltrs complete all as specified and directed . | BI01010001010000000000000515BI0100001203 | 5 | Each |
| 93 | 93 | Supply & fixing copper condensor coil suitable for water cooler of capacity 150/180 ltrs complete all as specified and directed . | BI01010001010000000000000515BI0100001204 | 5 | Each |
| 94 | 94 | Supply & fixing PVC float valve 15 mm bore with PVC heavy duty ball and rod complete all as specified and directed . | BI01010001010000000000000515BI0100001205 | 16 | Each |
| 95 | 95 | Supply & fixing brass chromium plated push cock of 15 mm bore (as per sample) complete all as specified and directed . | BI01010001010000000000000515BI0100001206 | 25 | Each |
| 96 | 96 | Supply & fixing wiring kit for water coolers of any capacity and make complete all as directed. | BI01010001010000000000000515BI0100001207 | 15 | Each |
| 97 | 97 | Material and labour for repairing of water cooler storage tanks leakage by soldering/brazing work complete all as specified and directed . | BI01010001010000000000000515BI0100001208 | 5 | Each |
| 98 | 98 | M&L for taking out carefuly the hermetically sealed defective compressor from water cooler 40/80 ltrs and replacing with factory repaired compressor and gas charging complete in all respect and testing at required pressure incl replacement of mounting rubber, bushes nut bolts etc and testing after installation complete all as specified and directed. Make Sriram/Usha/Voltas/Blue Star. Note : Gas charging with refrigerant R-22/314A of water cooler will be measured & paid for separately. | BI01010001010000000000000515BI0100001209 | 8 | Each Job |
| 99 | 99 | All as per item No 98.00 above but water cooler of capacity of 150 to 180 Ltrs. | BI01010001010000000000000515BI0100001210 | 3 | Each Job |
| 100 | 100 | Material and labour for Charging of refrigerent gas R-22/ 314A in water cooler with required quantity after flushing out and testing the system against leakage and repair of connected works including replacement of copper capillary tube of any capacities and testing the same after re-installation complete all as specified and directed . | BI01010001010000000000000515BI0100001211 | 28 | Kg |
| 101 | 101 | Material and labour for re-winding of fan motor of water coolers of any capacity with supper enameled copper wire complete all as specified and directed . | BI01010001010000000000000515BI0100001212 | 6 | Each |
| 102 | 102 | Material and labour for preparation of surface of water cooler of 40/80 ltr capacity by rubbing with emery paper and applying spray painting with two coat of synthetic enamel paint over a coat or red oxide primer of approved make without damaging other parts / wiring of the machine and including writing of MES/SM No on the machine complete all as specified and directed. | BI01010001010000000000000515BI0100001213 | 5 | Each |
| 103 | 103 | REFRIGERATORS : Repair / servicing of refrigerators of any capacity including writing of serial No / MES No and SM No on the machine Complete all as specified and directed. Note :- Spare parts shall be measured and paid separately under respective item of BOQ here in after | BI01010001010000000000000515BI0100001214 | 35 | Each Job |
| 104 | 104 | Supply & fixing copper capillary tube for any type & capacity of refrigerator and testing the same after re-installation complete all as specified and directed . | BI01010001010000000000000515BI0100001215 | 20 | RM |
| 105 | 105 | Supply & fixing starting relay suitable for any type and capacity of refrigerators complete all as specified and directed . | BI01010001010000000000000515BI0100001216 | 14 | Each |
| 106 | 106 | Supply & fixing thermostat switch with knob suitable for any type and capacity of refreigerators complete all as specified and directed . | BI01010001010000000000000515BI0100001217 | 10 | Each |
| 107 | 107 | Supply & fixing magnetic door gasket of refrigerators of capacity 310/165/280 ltr for any make as per site requirement complete all as specified and directed. | BI01010001010000000000000515BI0100001218 | 5 | RM |
| 108 | 108 | Supply & fixing bulb screw type suitable for any type of refrigerators as per site requirement complete all as specified and directed. | BI01010001010000000000000515BI0100001219 | 10 | Each |
| 109 | 109 | Supply & fixing refrigerators tray/grill set as per sample suitable for any type & capacity of refrigerator complete all as specified and directed . | BI01010001010000000000000515BI0100001220 | 15 | Each |
| 110 | 110 | Supply & fixing overload of refrigerators of any make and capacity complete all as specified and directed. | BI01010001010000000000000515BI0100001221 | 15 | Each |
| 111 | 111 | Supply & fixing freezer assembly suitable for any capacity and make of refrigerators complete all as specified and directed . | BI01010001010000000000000515BI0100001222 | 10 | Each |
| 112 | 112 | Supply & fixing condencer coil suitable for refrigerators of any capacity complete all as specified and directed . | BI01010001010000000000000515BI0100001223 | 8 | Each |
| 113 | 113 | Supply & fixing motor suitable for refrigerators of any capacity complete all as specified and directed . | BI01010001010000000000000515BI0100001224 | 6 | Each |
| 114 | 114 | Taking out carefully hermetically sealed defective compressor for capacity 165 Ltrs to below 250 Ltrs from refrigerators and replacing with new compressor and gas charging complete in all respect and testing at required pressure incl replacement of mounting rubber, bushes nut bolts etc and testing after installation complete all as specified and directed. Note : (i) Gas charging with refrigerant R-134 of Refrigerator will be measured & paid for separately under respective item of BOQ. | BI01010001010000000000000515BI0100001225 | 4 | Each |
| 115 | 115 | All as per item No 114.00 above but of capacity 250 ltrs to 310 ltrs complete all as specified and directed. | BI01010001010000000000000515BI0100001226 | 8 | Each |
| 116 | 116 | Material and labour for charging of refrigerent gas with R-134,required quantity after flushing out and testing the system against leakage and repair of connected works of any capacity and putting the refrigerators in perfect working condition and testing the same after re-installation complete all as specified and directed . | BI01010001010000000000000515BI0100001227 | 20 | Kg |
| 117 | 117 | Supply and fixing PCB for refrigerator of grosss capacity from 165 to 250 Ltr suitable for any make and capacity as per site requirement complete all as specified and directed . | BI01010001010000000000000515BI0100001228 | 3 | Each |
| 118 | 118 | Supply and fixing PCB for refrigerator of grosss capacity from 250 to 310 Ltr suitable for any make and capacity as per site requirement complete all as specified and directed. | BI01010001010000000000000515BI0100001229 | 3 | Each |
| 119 | 119 | DESERT COOLER : Material and Labour for repair and servicing of desert cooler body of any size including spray painting externally after scrapping out the existing paint with one coat of synthetic enamel paint on outer surfaces and one coat of anticorrosive paint on inner surfaces complete all as specified and directed. Note :-Spare parts shall be measured and paid under respective item of Sch . | BI01010001010000000000000515BI0100001230 | 161 | Each |
| 120 | 120 | Servicing of desert cooler of any size including changing of grass wood pad at site irrespective floor/height with his own arrangement complete all as specified and directed. | BI01010001010000000000000515BI0100001231 | 40 | Each |
| 121 | 121 | Taking down desert cooler including disconnecting the desert cooler form water pipe and close the water flow irrespective of height /floor and deposite to E/M yard complete all as specified and directed. | BI01010001010000000000000515BI0100001232 | 25 | Each Job |
| 122 | 122 | Fixing of desert cooler including connection of water pipe and all required accessries to fix to fix desert cooler with his own arrangement irrespective of height/floor after collecting desert coller from E/M yard all as directed by Engr-in-Charge. | BI01010001010000000000000515BI0100001233 | 25 | Each Job |
| 123 | 123 | Supply & fixing desert cooler kit (comprising of desert cooler fan motor with blade set 500/450 mm sweep speed not less than 1350 RPM, 3 speed AC motor 230 volts, pump as per existing & all minor accessories required including wiring etc complete all as specified and directed . | BI01010001010000000000000515BI0100001234 | 50 | Each |
| 124 | 124 | Supply & fixing submersible mini pump AC 230 volts 50 cycle 18 watts complete all as specified and directed . | BI01010001010000000000000515BI0100001235 | 225 | Each |
| 125 | 125 | Supply only complete body of desert cooler made of GI sheet power coated with elegant finish ,sump capacity should not less than 80 Ltrs of size 840X660X 660 mm, thickness of sheet of sump tank-1.0mm, thickness of top of the body -0.80mm including one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed . | BI01010001010000000000000515BI0100001236 | 25 | Each |
| 126 | 126 | Supply only slelector switch 3 speed with knob suitable for desert cooler as per site complete all as specified and directed. | BI01010001010000000000000515BI0100001237 | 35 | Each |
| 127 | 127 | Supply only wood wool pads for any type of desert coolers complete all as specified and directed. | BI01010001010000000000000515BI0100001238 | 250 | Set of three |
| 128 | 128 | Supply only PVC pipe 15mm dia medium quality in length as per site requirement complete all as specified and directed. | BI01010001010000000000000515BI0100001239 | 120 | RM |
| 129 | 129 | Supply only front grill of Desert cooler of suitable size and gauge as per site requirement all as specified and directed . | BI01010001010000000000000515BI0100001240 | 20 | Each |
| 130 | 130 | Supply only panel made out of 24 SWG sheet suitable for Desert cooler as per sample complete all as specified and directed . | BI01010001010000000000000515BI0100001241 | 50 | Set of Three |
| 131 | 131 | Supply only condencer 4MFD suitable for desert cooler complete all as specified and directed. | BI01010001010000000000000515BI0100001242 | 200 | Each |
| 132 | 132 | Supply only PVC water distributor 3 way 15 mm dia for Desert cooler complete all as specified and directed . | BI01010001010000000000000515BI0100001243 | 40 | Each |
| 133 | 133 | Supply only PVC elbow 15 mm size suitable for Desert cooler complete all as specified and directed. | BI01010001010000000000000515BI0100001244 | 84 | Each |
| 134 | 134 | Material and labour for rewinding of fan motor of desert cooler with supper enamel copper winding wire of suitable gauge including varnishing and making connection to the desert cooler complete all as specified and directed . | BI01010001010000000000000515BI0100001245 | 84 | Each |
| 135 | 135 | DEEP FREEZER : Material & Labour for Servicing including cleaning of deep freezer of any capacity complete all as specified and directed. | BI01010001010000000000000515BI0100001246 | 25 | Each |
| 136 | 136 | Material and Labour for taking out carefuly the hermetically sealed defective compressor for capacity 300 to 320 Ltrs from Deep -Freezer and refixing after replacing with factory repaired compressors from the authorised dealer and gas charging complete in all respect and testing at required pressure and re-installing at site incl replacement of mounting rubber, bushes nut bolts etc and testing after installation complete all as specified and directed. | BI01010001010000000000000515BI0100001247 | 3 | Each |
| 137 | 137 | Material and Labour for taking out carefuly the hermetically sealed defective compressor for capacity 250 /275Ltrs from Deep -Freezer and refixing after replacing with factory repaired compressors from the authorised dealer and gas charging complete in all respect and testing at required pressure and re-installing at site incl replacement of mounting rubber, bushes nut bolts etc and testing after installation complete all as specified and directed. Note : For item No 136.00 & 137.00 Gas charging with refrigerant R-134 of Deep -Freezer will be measured & paid for separately under res item of BOQ. | BI01010001010000000000000515BI0100001248 | 3 | Each |
| 138 | 138 | Material and Labour for Charging of refrigerent gas for Deep Freezer with R-134 ,required quantity after flushing out and testing the system against leakage and repair of connected works including replacement of copper capillary tube of any capacities and putting the Deep-Freezer in perfect working condition and testing the same after re-installation complete all as specified and directed | BI01010001010000000000000515BI0100001249 | 9 | Kg |
| 139 | 139 | Supply and fixing main control board/ panel to control temperature including thermostat of deep freeezer as requirement of site complete all as specified and directed . | BI01010001010000000000000515BI0100001250 | 5 | Each |
| 140 | 140 | Supply and fixing copper condeser coil of deep freezer as per site requirement complete all as specified and directed . | BI01010001010000000000000515BI0100001251 | 4 | Each |
| 141 | 141 | Supply and fixing motor with blade to cool condenser coil as per site requirement complete all asspecified and directed . | BI01010001010000000000000515BI0100001252 | 5 | Each |
| 142 | 142 | Supply and fixing starting relay as per site requirement complete all as specified and directed | BI01010001010000000000000515BI0100001253 | 7 | Each |
| 143 | 143 | Supply and fixing overload relay as per site requirement complete all as specified and directed | BI01010001010000000000000515BI0100001254 | 6 | Each |
| 144 | 144 | Supply and fixing starting / running capacitor as per site requirement complete all as specified and directed . | BI01010001010000000000000515BI0100001255 | 8 | Each |
| 145 | 145 | VOLTAGE STABILIZER : Material and labour for rewinding of burnt transformer using super enamel copper wire of existing size as directed by EIC for the capacity of voltage stablizers of 5 KVA cap of any make. | BI01010001010000000000000515BI0100001256 | 5 | Each |
| 146 | 146 | All as per item No 145.00 but 4 KVA cap of any make. | BI01010001010000000000000515BI0100001257 | 6 | Each |
| 147 | 147 | All as per item No 145.00 but 3 KVA cap of any make. | BI01010001010000000000000515BI0100001258 | 7 | Each |
| 148 | 148 | All as per item No 145.00 but 2 KVA cap of any make. | BI01010001010000000000000515BI0100001259 | 10 | Each |
| 149 | 149 | All as per item No 145.00 but 1 KVA cap of any make. | BI01010001010000000000000515BI0100001260 | 15 | Each |
| 150 | 150 | Supply and fixing in replacement for cut off relay of the following cap of voltage stablizers 5 KVA cap of voltage stablizer. | BI01010001010000000000000515BI0100001261 | 10 | Each |
| 151 | 151 | All as per item No 150.00 but 4 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001262 | 10 | Each |
| 152 | 152 | All as per item No 150.00 but 3 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001263 | 8 | Each |
| 153 | 153 | All as per item No 150.00 but 2 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001264 | 12 | Each |
| 154 | 154 | All as per item No 150.00 but 1 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001265 | 15 | Each |
| 155 | 155 | Supply and fixing in replacement tranformer copper wounded suitable for voltage stabilizer of capacity 5 KVA with fixing accessories complete all as specifiedand directed. | BI01010001010000000000000515BI0100001266 | 3 | Each |
| 156 | 156 | Supply and fixing in replacement tranformer copper wounded suitable for voltage stabilizer of capacity 4 KVA with fixing accessories complete all as specifiedand directed . | BI01010001010000000000000515BI0100001267 | 3 | Each |
| 157 | 157 | Supply and fixing in replacement tranformer copper wounded suitable for voltage stabilizer of capacity 3 KVA with fixing accessories complete all as specifiedand directed . | BI01010001010000000000000515BI0100001268 | 2 | Each |
| 158 | 158 | Supply and fixing in replacement tranformer copper wounded suitable for voltage stabilizer of capacity 2 KVA with fixing accessories complete all as specifiedand directed . | BI01010001010000000000000515BI0100001269 | 4 | Each |
| 159 | 159 | Supply and fixing in replacement tranformer copper wounded suitable for voltage stabilizer of capacity 1 KVA with fixing accessories complete all as specifiedand directed . | BI01010001010000000000000515BI0100001270 | 3 | Each |
| 160 | 160 | Supply and fixing automatic voltage stabilizer capacity 4KVA work efficiently for input voltage variation betwwen 130 to 300 volts, digital display,complete all as specified and directed .make- microtek- model EM 4130+ or equivalent in V Guard / Volina | BI01010001010000000000000515BI0100001271 | 4 | Each |
| 161 | 161 | Supply and fixing circuit wiring kit complete of the following capacity of the voltage stabilizer complete all as specified and directed. (a) 5 KVA cap of voltage stablizer. | BI01010001010000000000000515BI0100001272 | 4 | Each |
| 162 | 162 | All as per item No 161.00 but 4 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001273 | 5 | Each |
| 163 | 163 | All as per item No 161.00 but 3 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001274 | 4 | Each |
| 164 | 164 | All as per item No 161.00 but 2 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001275 | 6 | Each |
| 165 | 165 | All as per item No 161.00 but 1 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001276 | 4 | Each |
| 166 | 166 | Supply and fixing of replacement of high/low cut off relay circuit of the 5 KVA capacity of the voltage stabilizer complete all as specified and directed. | BI01010001010000000000000515BI0100001277 | 3 | Each |
| 167 | 167 | All as per item No 166.00 but 4 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001278 | 3 | Each |
| 168 | 168 | All as per item No 166.00 but 3 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001279 | 4 | Each |
| 169 | 169 | All as per item No 166.00 but 2 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001280 | 4 | Each |
| 170 | 170 | All as per item No 166.00 but 1 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001281 | 8 | Each |
| 171 | 171 | Supply and fixing of mini transformer for the 5 KVA capacity of the voltage stablizer complete all as specified and directed. | BI01010001010000000000000515BI0100001282 | 3 | Each |
| 172 | 172 | All as per item No 171.00 but for 4 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001283 | 4 | Each |
| 173 | 173 | All as per item No 171.00 but for 3 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001284 | 4 | Each |
| 174 | 174 | All as per item No 171.00 but for 2 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001285 | 4 | Each |
| 175 | 175 | All as per item No 171.00 but for 1 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001286 | 4 | Each |
| 176 | 176 | Supply and fixing time dealy relay for the 5 KVA capacities of the voltage stablizer complete all as specified and directed. | BI01010001010000000000000515BI0100001287 | 4 | Each |
| 177 | 177 | All as per item No 176.00 but for 4 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001288 | 3 | Each |
| 178 | 178 | All as per item No 176.00 but for 3 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001289 | 6 | Each |
| 179 | 179 | All as per item No 176.00 but for 2 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001290 | 5 | Each |
| 180 | 180 | All as per item No 176.00 but for 1 KVA cap of voltage stabilizer. | BI01010001010000000000000515BI0100001291 | 5 | Each |
| 181 | 181 | Supply and fixing H T-4 complete all as per site requirement suitable for any capacity of stabilizers. | BI01010001010000000000000515BI0100001292 | 10 | Each |
| 182 | 182 | Supply and fixing volt meter AC, 230 volt of any capacity suitable for voltage stabilizer complete all as specified and directed. | BI01010001010000000000000515BI0100001293 | 15 | Each |
| 183 | 183 | Supply and fixing indicator bulb suitable for voltage stabilizers complete all as specified and directed . | BI01010001010000000000000515BI0100001294 | 20 | Each |
| 184 | 184 | Supply and fixing copper wire three core 1 Sqmm all as specified and directed. | BI01010001010000000000000515BI0100001295 | 150 | RM |
| 185 | 185 | Supply and fixing copper wire three core 1.5 Sqmm all as specified and directed. | BI01010001010000000000000515BI0100001296 | 120 | RM |
| 186 | 186 | Supply and fixing copper wire three core 2.5 Sqmm all as specified and directed. | BI01010001010000000000000515BI0100001297 | 100 | RM |
| 187 | 187 | Supply and fix three core 0.75Sqmm flexible copper wire all as specified and directed. | BI01010001010000000000000515BI0100001298 | 200 | RM |
| 188 | 188 | Supply and fixing in repair plug top 3 pin 5/6 Amp suitable at site complete all as specified and directed. | BI01010001010000000000000515BI0100001299 | 30 | Each |
| 189 | 189 | Supply and fixing in repair socket 5/15 Amp multipurpose for stabilizer complete al as specified and directed. | BI01010001010000000000000515BI0100001300 | 20 | Each |
| 190 | 190 | Supply and fixing in repair plug top 3 pin 15/16 Amp suitable at site complete all as specified and directed. | BI01010001010000000000000515BI0100001301 | 22 | Each |