Military Engineer Services-MES has published Repair/Maint Of Summer Appliances Of Hq Delhi Area , 285Fd Wksp , 147Fd Wksp , 5Mli , 202Bd Coy , Eetsu , 1Wec , Station Wksp Eme , 5Sig Gp , Dcn Sub Gp Palam , 150 Ta Punjab , 500 ( I ) Sig Coy , Rrc , Mes Ib , 224 Transit Camp , 1Ciu , 60. Submission Date for this Tender is 10-07-2021. Air Conditioner Tenders in DELHI CANTT Delhi. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 03-Jul-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 10-07-2021 |
Name of Work: REPAIR/MAINT OF SUMMER APPLIANCES OF HQ DELHI AREA, 285 FD WKSP, 147 FD WKSP, 5 MLI, 202 BD COY, EETSU, 1 WEC, STATION WKSP EME, 5 SIG GP, DCN SUB GP PALAM, 150 TA PUNJAB, 500 (I) SIG COY, RRRC, MES IB, 224 TANSIT CAMP, 1 CIU, 60 INF BDE, 20 MANDIR MARG, COMD HUTS, 48 MVH, ADHOC TANSIT CAMP AND DELHI AREA OFFRS MESS ETC UNDER GE(U) P&M, DELHI CANTT -10. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. | 250 | Each job | |
2 | 2 | Taking down for servicing of Window type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.\nNotes for Ser Item No 1 & 2 :- \n(i) Replacement of defective spares for making the AC units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate. \n(ii) Penalty will be charged for not attending complaint from 12 Hours to 24 hours Rs. 500/- each complaint. Further if complaint not attended and rectified within 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues. | 80 | Each job | |
3 | 3 | Supply only Running capacitor 36+6 MFD. (Make:- Epcos/ Usha/ Keltron.) | 60 | Each | |
4 | 4 | Supply only Running capacitor 45+5 MFD. (Make:- Epcos/ Usha/ Keltron.) | 60 | Each | |
5 | 5 | Supply only Running capacitor 50+6 MFD. (Make:- Epcos/ Usha/ Keltron.) | 60 | Each | |
6 | 6 | Supply only Starting capacitor 80-100 MFD. (Make:- Epcos/ Usha/ Keltron.) | 10 | Each | |
7 | 7 | Supply only Starting capacitor 100-120 MFD. (Make:- Epcos/ Usha/ Keltron.) | 10 | Each | |
8 | 8 | Supply only Starting Relay 1622. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.) | 30 | Each | |
9 | 9 | Supply only Starting Relay 2000. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.) | 25 | Each | |
10 | 10 | Supply only Overload Relay. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.) | 20 | Each | |
11 | 11 | Supply only Thermostat switch 2059/2064/2054. ( Make :- Indfos/ Renutrol). | 20 | Each | |
12 | 12 | Supply only Condenser fan blade for Window type A.C of Capacity 1.5/2 TR made of Plastic. | 10 | Each | |
13 | 13 | Supply only Condenser fan blade for spilt Type A.C of Capacity 1.5/2 TR made of Plastic. | 10 | Each | |
14 | 14 | Supply only Wiring kit for Window/split type AC of Capacity 1.5/2 TR | 8 | Each | |
15 | 15 | Supply only remote control including battery for split AC Cap 1.5/2 TR of make as per site requirement and replace of old one complete all as directed by Engr-in-Charge. (Make- As per sample approved by GE) | 15 | Each | |
16 | 16 | Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for split/Tower AC of capacity 1.5/2/4 TR as directed by Engr-in-Charge. | 25 | Each | |
17 | 17 | Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for window AC of capacity 1.5/2 TR as directed by Engr-in-Charge.\nNote for item No 3 to 17:- \nMaterials of item Nos 3 to 17 to be incorporated in item Nos 1 & 2 here-in-before. \n | 15 | Each | |
18 | 18 | Supply & fixing in repairs plastic louvers (Front panel) for Window AC 1.5/2 TR complete all as directed by Engr-in-Charge. | 5 | Each | |
19 | 19 | Supply & fixing in repairs of suction and discharge valve set of size 15mm (5/8''), 6mm (1/4'') and 12mm (1/2'') for Split AC 1.5/2 TR capacity complete all as directed by Engr-in-Charge. (Make:- LG/ Voltas/ Blue Star/ Hitachi). {Note:- (i) 15mm (5/8'') or 6mm (1/4'') and 12mm (1/2'') made one set\n(ii) Supply & filling of refrigerant gas shall be measured and paid under relevent item.} | 40 | Each | |
20 | 20 | Supply & fixing in repairs of capillary tube for Split/ Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. (Make:- As per Sample) | 80 | Each | |
21 | 21 | Supply & fixing in repairs of capillary filter for Split/ Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. (Make:- As per Sample) | 80 | Each | |
22 | 22 | Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC of capacity 1.5/ 2/ 4TR and refixing after necessary repair for satisfactory functioning of the AC unit complete all as specified and directed by Engineer-in-charge. | 70 | Each | |
23 | 23 | Taking down unserviceable reversible valve for split/ window type AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required copper pipe complete all as specified and directed by Engr-in-charge. (Make:- As per sample approved by GE) (Note:- Supply & filling of refrigerant gas shall be measured and paid under relevent item.) | 25 | Each Job | |
24 | 24 | -ditto- all as per item No. 23 above but spilt/window type Air Conditioner of capacity 2 TR. | 20 | Each Job | |
25 | 25 | Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the window type Air Conditioner of Cap 2 Ton, of any make any type from any location and Supply , Installing and testing of new sealed unit compressor alongwith test certificate from manufacturer including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc & Charging of Gas R-22/R-410a/R-32 and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ LG)\nNote :- Transportation Charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above. | 2 | Each job | |
26 | 26 | -ditto- all as per item No. 25 above but window type Air Conditioner of Capacity1.5 TR. (Make:- Emerson /Tecumseh/ LG) | 30 | Each job | |
27 | 27 | -ditto- all as per item No. 25 above but spilt type Air Conditioner of Capacity 2 TR. (Make:- Emerson /Tecumseh/ LG) | 35 | Each job | |
28 | 28 | -ditto- all as per item No. 25 above but spilt type Air Conditioner of Capacity 1.5 TR. (Make:- Emerson /Tecumseh/ LG) | 36 | Each job | |
29 | 29 | Supply & fixing in repairs of Window A/C air blower motor copper wounded for 1.5 TR & 2 TR capacity AC complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.) | 25 | Each job | |
30 | 30 | Supply & fixing in repairs of Indoor Air blower motor for Split 1.5 TR & 2 TR capacity complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.) | 35 | Each job | |
31 | 31 | Supply & fixing in repairs of copper wounded condenser fan motor for Split type AC of 1.5 TR & 2 TR capacity outdoor units complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.) | 40 | Each job | |
32 | 32 | Disconnecting the mains and taking out the unserviceable condenser coil of window type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make:- Voltas/Carrier/LG) | 12 | Each job | |
33 | 33 | -ditto- all as per item No. 32 above but spilt type Air Conditioner Capacity 1.5/ 2 TR. (Make:- Voltas/Carrier/LG) | 20 | Each job | |
34 | 34 | Supply & fixing in repairs of evaporator/cooling coil for window type Air Conditioner of capacity 1.5/ 2TR of existing make and size complete all as specified & as directed by Engr-in-Charge. (Make:- As per Sample) | 11 | Each job | |
35 | 35 | -ditto- all as per item No. 34 above but spilt type Air Conditioner Capacity 1.5/ 2 TR. (Make:- As per Sample) | 10 | Each job | |
36 | 36 | Supply and fixing in repairs of 1.5TR capacity split type Air Conditioner outdoor kit including condenser coil, blower motor, chasis, base plate complete set except compressor complete all as specified & as directed by Engr-in-Charge. (Make:- Nepoleon/ Commander/ Camipro/ Skoda.) | 8 | Each job | |
37 | 37 | -ditto- all as per item No. 36 above but spilt type Air Conditioner of capacity 2 TR. (Make:- Nepoleon/ Commander/ Camipro/ Skoda.) | 8 | Each job | |
38 | 38 | Taking down unserviceable indoor unit of split type AC of any make and supply & fixing new indoor unit complete set suitable for 1.5 TR capacity complete all as directed by Engr-in-Charge. (Make:- LG/Carrier/Voltas.) | 10 | Each job | |
39 | 39 | -ditto- all as per item No. 38 above but spilt type Air Conditioner of capacity 2 TR. (Make:- LG/Carrier/Voltas.) | 10 | Each job | |
40 | 40 | Supply & fixing heavy duty copper pipe 6mm (1/4") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- Malaysia/Cemipro or equivalent) | 80 | RM | |
41 | 41 | -ditto- all as per item No. 40 above but copper pipe 10mm (3/8") dia/ bore. | 80 | RM | |
42 | 42 | -ditto- all as per item No. 40 above but copper pipe 12mm (1/2") dia/ bore. | 70 | RM | |
43 | 43 | -ditto- all as per item No. 40 above but copper pipe 15mm (5/8") dia/ bore. | 70 | RM | |
44 | 44 | Taking down unserviceable insulation for copper pipe, supply and fixing new insulation for copper pipes suitabale for Split AC of capacity from 1.5 to 4.0 TR all as specified and directed by Engineer-in-charge. | 80 | RM | |
45 | 45 | Taking down unserviceable PVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia for Split/window AC all as specified and directed by Engineer-in-charge. (Make:- Prayag/ Supreme/ Prince.) | 20 | RM | |
46 | 46 | Supply and filling refrigerant gas R-22/R-410A in window type /Split Type AC unit of capacity 1.5/2/3/4 TR including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition. (Make : Mefron/ Floron/ Refron.) | 450 | Kg | |
47 | 47 | Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for Split AC 1.5 to 4.0 TR all as specified as directed by Engineer in-charge. (Make:- L & T/ Siemens/ ABB/ Legrand) | 20 | Each | |
48 | 48 | Dismantling and removing defective burnt blower unit motor of any capacity and make of 1.5/2 TR capacity window type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing the same in existing position and testing complete all as specified and as directed. | 5 | Each Job | |
49 | 49 | Dismantling and removing defective burnt blower unit motor of any capacity and make of indoor units of split/tower type AC of capacity 1.5/2/4 TR capacity rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing the same in existing position and testing complete all as specified and as directed. | 18 | Each Job | |
50 | 50 | Dismantling and removing defective burnt outdoor unit motor of any capacity and make of indoor units of split/tower type AC of capacity 1.5/2/4 TR capacity rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing the same in existing position and testing complete all as specified and as directed. | 25 | Each Job | |
51 | 51 | Dismantling the existing broken blower fan blade of the indoor units of the split type AC of Capacity 1.5/2 TR and supply and fixing in repairs new blower fan blade complete all as specified and directed. | 12 | Each Job | |
52 | 52 | Supply and fixing in repairs of 1.5 TR capacity window type AC kit including condenser coil, cooling coil, front grill blower motor, chasis, base plate complete set except compressor. (Make:- Nepoleon/ Commander/ Speed.) | 6 | Each | |
53 | 53 | Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing capping (heavy grade) of suitable size with all fittings and casing caping accessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed. | 150 | RM | |
54 | 54 | Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing capping (heavy grade) of suitable size with all fittings and casing caping accessories of surface type including one run 4 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed. (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD and make of Casing caping:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)} {Notes for item No.53 & 54 :-(i) Two runs of cable with one runs earth wire and PVC casing capping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} | 150 | RM | |
55 | 55 | Supply and fixing in repairs of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps iincluding taking down old unservisible metal clad socket complete all as specified and as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T) | 15 | Each | |
56 | 56 | Supply and fixing in repairs of MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T) | 20 | Each | |
57 | 57 | Supply & fixing in repair metal clad socket of 20 Amps complete all as specified & as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T) | 10 | Each | |
58 | 58 | Supply & fixing in repairs metal clad plug with two pin of capacity 20 Amps complete all as specified & as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T) | 10 | Each | |
59 | 59 | Collecting of unserviceable voltage stabilizer of capacity 4 & 5 KVA from the MES store yard of AGE AC(OTBH) or dismantling the same from site and transporting to contractors workshop for locating the fault including checking the serviceability of electrical/electronic circuits relays and replacement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to MES store yard complete all as specified and directed by Engr-in-charge\nNote :- 1. Replacement of defective spares and rewinding of transformer of voltage stabilizer will be measured & paid separately under relevant items and Labour charges for taking out old spares & fixing of new spares shall deemed to be included in unit rate quoted. | 50 | Each Job | |
60 | 60 | Supply only following new spare parts of Voltage stabilizer of capacity 4 & 5 KVA :- | |||
61 | 61 | Voltmeter (Analog) 0 to 300 volts any type shape single phase 50 Hz AC supply. \n(Make:- AE/ MIECO/ Rishabh) | 5 | Each | |
62 | 62 | Digital type Voltmeter 0 to 300 volts any type shape single phase 50 Hz AC supply, (Make:- AE/ MECO/ Rishabh) | 15 | Each | |
63 | 63 | Printer circuit control card suitable for 4 to 5 KVA. | 15 | Each | |
64 | 64 | Input/output switch (Make:- AE/Rishabh/Meco) | 15 | Each | |
65 | 65 | Push on switch (Make:- AE/Rishabh/Meco) | 15 | Each | |
66 | 66 | Indicator with neon bulbs (Make:- AE/L & T/ C & S) | 15 | Each | |
67 | 67 | Trigger Transformer for 4 & 5 KVA. | 15 | Each | |
68 | 68 | Time relay and High/low voltage cut off circuit with relay suitable for 4 KVA & 5 KVA (Make Renutorl/Technomac) \n(Note for item Nos 61 to 68 :- Materials of item Nos 61 to 68 to be incorporated in item No 59 here-in-before ) | 15 | Each | |
69 | 69 | Taking out the burnt winding of transformer of voltage stabilizer and preparing core after cleaning by suitable cleaning agent and rewinding the transformer of voltage stabilizer with super enameld copper wire of existing gauge including varnishing, heating and refiting of capacity 3 KVA voltage stabilizer, complete all as specifies & directed by Engr-in-Charge. | 15 | Each | |
70 | 70 | -ditto- all as per item No. 69 here-in-before but 4 KVA. | 15 | Each | |
71 | 71 | -ditto- all as per item No. 69 here-in-before but 5 KVA. | 15 | Each | |
72 | 72 | Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed by Engineer-in-Charge.\nNote :- 1. Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items and Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above. | 150 | Each | |
73 | 73 | Supply only over load protector relay suitable for 40/80 Ltrs capacity water coolers. (Make : Renutrol/Sri Ram/Microtech) | 15 | Each | |
74 | 74 | Supply only thermostat suitable for 40/80/120/150 Ltr capacity water coolers. (Make : Indfas/Renutrol) | 28 | Each | |
75 | 75 | Supply only condenser motor fan blade suitable for 40/80/120/150 Ltr capacity water coolers. | 10 | Each | |
76 | 76 | PVC flexible drain Hose Pipe 40 mm. | 15 | RM | |
77 | 77 | Waste water tray complete suitable for 40/80, 60/120, 150/150 Ltr capacity water coolers all as directed. ( Suitable for Voltas/Sidwal/Blue Star make water coolers). | 2 | Each | |
78 | 78 | Supply only chromium plated push taps suitable for 40/80/120/150 Ltr capacity water coolers all as directed.\nMake : Usha/Prayag/Cera/Essco. | 30 | Each | |
79 | 79 | Supply only PVC float valve of size 15mm dia complete suitable for 40/80/120/150 Ltr capacity water coolers including GI socket of same size all as directed. | 10 | Each | |
80 | 80 | Supply only Starting Capacitor 25 MFD. (Make :- Usha/Epcos/Keltron) | 20 | Each | |
81 | 81 | Supply only running Capacitor 10 MFD.(Make :- Usha/Epcos/Keltron) | 20 | Each | |
82 | 82 | Supply only Starting relay suitable for 40/80, 60/120, 150/150 Ltr. Make : Renutrol/Sri Ram/Microtech.\nNote for item Nos 73 to 82:- \nMaterials of item Nos 73 to 82 to be incorporated in item No 72 here-in-before. \n | 15 | Each | |
83 | 83 | Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/16 HP from water cooler cap.60/120, 150/150 Ltr and supply and replace with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as directed by Engr-in-Charge. (Make : AUE, Crompton Greaves / Cool Master) | 20 | Each Job | |
84 | 84 | All as per item No.83 above but 1/32 HP Water cooler of Capacity 40/80 Ltrs. | 20 | Each Job | |
85 | 85 | Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing Water Coolers of 40/80 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.) | 20 | Each | |
86 | 86 | Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing Water Coolers of 60/120 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.) | 20 | Each | |
87 | 87 | Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing Water Coolers of 150/150 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.) | 10 | Each | |
88 | 88 | Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water Coolers of capacity 60/120, 150/150 Ltrs complete all as specified & as directed. | 12 | Each job | |
89 | 89 | Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80 Ltrs complete all as specified & as directed. | 12 | Each job | |
90 | 90 | Dismantling the evaporator/cooling coil of water cooler capacity 150/150, 60/120 & 40/80 Ltrs, checking the leakages of gas and rectify the leakages by brazing or any other manner complete all as specified & as directed by Engr-in-Charge. | 8 | Each Job | |
91 | 91 | Supplying and fixing in repairs stop valve 15mm bore dia, fancy type chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unions complete all as specified and as directed. Make:-ESCCO/ CERA/ PARRYWARE/ HINDWARE) | 50 | Each | |
92 | 92 | Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. (Make:- Prayag/ Polytuff) | 30 | Each Job | |
93 | 93 | Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing refrigerators of 165 to 210 Ltrs capacity complete all as specified and directed. \n(Make :- Emerson /Tecumseh/LG.) | 18 | Each | |
94 | 94 | Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing refrigerators of 280 to 310 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.)\nNote :- (i) The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor's repair workshop and back. | 12 | Each | |
95 | 95 | Dismantling of existing repairable Refrigerators of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop for carrying out repairs and renewal/replacement of parts, reassembling and transporting back to the site including installation of the same on the same location and making electric connection etc, all as specified and directed by Engineer-in-Charge. (Note :- Parts renewed shall be measured and paid separately under appropriate items.) | 25 | Each Job | |
96 | 96 | Supply and fix in repairs capillary tube of existing size including necessary brazing suitable for 165/ 300 Ltrs capacity refrigerator, including dismantling the old unserviceable one all as specified and directed. (Make:- As per sample) | 35 | Each Job | |
97 | 97 | Supply and fix in repairs over load protector relay suitable for 165/300/310 Ltrs capacity refrigerator all as directed. (Make : Renutrol/Sri Ram/Microtech) | 8 | Each | |
98 | 98 | Supply and fix in repairs thermostat suitable for 165/300/310 Ltrs capacity refrigerators all as directed. (Make: Indfoss/Renutrol/Godrej.) | 9 | Each | |
99 | 99 | Supply and fix in repairs freezer door with spring of refregierators of any capacity complete all as specified and directed by Engr-in-charge. | 10 | Each | |
100 | 100 | Supply and fixing in repairs vegetable basket with glass suitable for 165/300/310 Ltrs capacity refrigerators complete all as specified and directed by Engr-in-charge. | 10 | Each | |
101 | 101 | Supply and fixing in repairs PVC defrost tray as per sample suitable of 165/300/310 Ltrs capacity refrigerators. (Make : Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator). | 5 | Each | |
102 | 102 | Supply and fixing in repairs door gasket for refrigerators of capacity upto 250 Ltrs complete all as specified and directed. | 5 | Each | |
103 | 103 | Supply and fixing in repairs door gasket for refrigerators of capacity more than 250 Ltrs but upto 310 Ltrs complete all as specified and directed. | 3 | Each | |
104 | 104 | Dismantling of existing repairable deep freezers of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop for carrying out repairs and renewal/replacement of parts, reassembling and transporting back to the site including installation of the same on the same location and making electric connection etc, all as specified and directed by Engineer-in-Charge. Note:-(i) Replacement of defective spares for making the deep freezer units in satisfactory working condition will be measured & paid separately under relevant items as 'Supply only' and Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate. ) | 25 | Each Job | |
105 | 105 | Supply only starting relay 1/6 HP open with OLP all as specified and directed. \n(Make :- Renutrol/Sri Ram/Microtech) | 10 | Each | |
106 | 106 | Supply only starting relay for 1/8 HP open type with OLP all as specified and directed. \n(Make : Renutrol/Sri Ram/Microtech) | 10 | Each | |
107 | 107 | Supply only over load protector suitable for upto 500 Ltrs capacity deep freezer all as specified and directed. (Make : Renutrol/Sri Ram/Microtech) | 10 | Each | |
108 | 108 | Supply only running capacitor for upto 500 Ltrs capacity deep freezer all as specified. (Make : Epcos/Usha/ Keltron) | 10 | Each | |
109 | 109 | Supply only thermostat suitable for upto 500 Ltrs capacity deep freezer all as specified and directed. ( Make :- Indfos/ Renutrol). | 10 | Each | |
110 | 110 | Supply only starting capacitor for upto 500 Ltrs capacity deep freezer all as specified and directed. (Make : Epcos/Usha/ Keltron)\nNote for item Nos 105 to 110:- \nMaterials of item Nos 105 to 110 to be incorporated in item No 104 here-in-before. \n | 10 | Each | |
111 | 111 | Supply & fixing in repairs Axial Fan for deep freezers complete all as specified and directed. | 10 | Each | |
112 | 112 | Taking down defective compressor of deep freezer of capacity Upto 300 Ltrs and any make and supplying and fixing new sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capilary and supply & charging of refrigerant gas Non CFC based or equivalent to Non CFC gas in required qty and testing complete all as specified and directed by Engineer-in-Charge. (Make :- Emerson /Tecumseh/LG.) | 12 | Each | |
113 | 113 | All as per item No 112 above but of capacity above 300 Ltrs but upto 500 Litres deep freezer compressors. (Make :- Emerson /Tecumseh/LG.) | 12 | Each | |
114 | 114 | M&L for taking down desert cooler of any type/size/model from any height / floor for servicing like changing of wood wool pads, kit motor, submersible pump, fan blade, front grill, wiring, capacitor, cleaning or any other repair work as specified and re-fixing to existing place after repair work/overhauling complete all as specified and directed.\nNote :- (i) The rates quoted by the contractor shall deemed to include the cost of T&P.\n(ii) The items required to be replaced shall be measured and paid separately under relevant items.\n | 400 | Each Job | |
115 | 115 | Supply only wood wool pad of suitable size for 24” sweep desert cooler complete all as specified and directed 01 Set comprising of 3 Nos of pads approximate weight 800-900 Gms (Make:- As per sample.)\n | 200 | Set of three | |
116 | 116 | All as per item No 115 above but 20” sweep approximate weight 700 -800 Gms. (Make:- As per sample.) | 200 | Set of three | |
117 | 117 | S & F in repairs submersible pump motor 230 Volts, single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed. (Make- Bajaj/ Crompton Greaves/ Khaitan.) | 250 | Each | |
118 | 118 | Supply and fixing in repairs of desert cooler kit fan motor, single speed, 230 V, 50 Hz of capacity 90 Watt 1450 RPM, copper wounded including nuts bolts for fixing complete all as specified and directed. (Make : Crompton Greaves/Usha/Khaitan) | 250 | Each | |
119 | 119 | Supply and fixing Desert cooler exhaust fan motor, single speed, 230 V, 50 Hz of capacity 150 Watt 1400 RPM, copper wounded including nuts bolts for fixing complete all as specified and directed. (Make : Havells/Crompton Greaves/Almonard) | 50 | Each | |
120 | 120 | Supply & fixing in repairs front grill for desert cooler of approved make suitable for fixing 5 Amp switch, three speed regulator and indicating lamp all as specified and directed. | 10 | Each | |
121 | 121 | Supply & fixing in repairs running capacitor of 4 MFD capacity for water cooler complete all as directed. \n(Make- USHA/EPCOS/KELTRON) | 200 | Each | |
122 | 122 | Supply & fixing in repairs running capacitor of 6 MFD capacity for water cooler complete all as directed. \n(Make- USHA/EPCOS/KELTRON) | 100 | Each | |
123 | 123 | Supply & fixing in repairs wire mesh for desert cooler pad (Set of Three) including taking down old one. | 300 | Each Set | |
124 | 124 | Supply & fixing in repairs PVC pipe for connecting pump and water distributor of size 15 mm dia. (Make:- Prayag/ Supreme/ Prince). | 250 | RM | |
125 | 125 | Supply & fixing in repairs PVC elbow for desert cooler of suitable size complete all as specified & as directed.\n\n | 250 | Each | |
126 | 126 | Supply & fixing in repairs PVC 4 Way distribution cross for desert cooler complete all as specified & as directed.\n\n | 250 | Each | |
127 | 127 | S&F in repairs flexible copper conductor cable, 3 core PVC insulated & PVC sheathed of size 1.5sqmm complete all as specified and directed. ( Make -Polycab/Kalinga Premium/Plaza). | 350 | RM | |
128 | 128 | S&F in replacement desert coolers fan blade of 18" (inch) sweep made out of Aluminium complete all as specified. | 200 | Each | |
129 | 129 | S&F in replacement desert coolers fan blade of 20" (inch) sweep made out of Aluminium complete all as specified. | 100 | Each | |
130 | 130 | Supply and fixing in repairs side panel of desert cooler of 20" (inch) sweep made out of 20 SWG, GI sheet suitable for fixing with the existing desert coolers, duly painted with synthetic enameled paint over a coat of red oxide primer complete all as specified and directed. | 20 | Each Set | |
131 | 131 | S&F in repairs switch piano flush type single pole one way 5Amp 230 V for desert cooler all as directed. (Make-Anchor/Kinjal/Havells) | 100 | Each | |
132 | 132 | S&F in repairs 3 pin plug top 15 Amp for desert cooler complete all as specified and directed. (Make-Anchor/Kinjal/Havells) | 25 | Each | |
133 | 133 | All as per item No. 132 above but 5 Amps. (Make-Anchor/Kinjal/Havells) | 200 | Each | |
134 | 134 | Supply and fixing in repairs cooler fan motor bracket sets made up as existing including painting complete all as specified and directed. | 140 | Each Set of four | |
135 | 135 | Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface. Repainting the complete desert coolers ie side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE(U) P&M (MES)” letter size of 50mm height at stencil in black/white including servicing and greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as per site requirement. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.) | 20 | Each Job | |
136 | 136 | S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE (U) P&M (MES)" letter size of 50mm height in stencil in black/ white all as specified and directed by Engr-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.) | 100 | Each | |
137 | 137 | Collecting Defective refrigerator with inverter type compressors and PCB from AGEAC (OTBH) storeyard carrying out the inspection from the authorised repair centre of LG to find out the defects in compressor, PCB, and carrying out the required repair work including initial charging of refrigerant gas & oil in compressor cleaning with vacuum cleaner or cleaning solution to make the refrigerator in satisfactory working condition complete all as specified and directed.\nNote:- (i) Spare parts shall be measured and paid seperately under relevant items.\n (ii) The rates quoted by the contractor shall deemed to include the transportation cost from AGEAC (OTBH) store to contractor's repair workshop and back. | 5 | Each job | |
138 | 138 | Supply only inverter type compressor for refrigerators of capacity 280/308/310 ltrs. Make:Emerson/ Tecumseh/LG | 6 | Each | |
139 | 139 | Supply only PCB compatible suitable for inverter type refrigerators of capacity 280/308/310 ltrs. (Note for item no 138 & 139:- Material of item No 138 &139 to be incorporated in item No 137 above.) | 5 | Each |