| 1 | 1 | Shunt Closing coil with Plunger assembly [Aux volt: 110V DC] | item1 | 1 | Nos |
|---|
| 2 | 2 | Series & Shunt Trip coils with plunger assembly & mounting bracket [4 coils = 1 set) | item2 | 1 | Nos |
|---|
| 3 | 3 | Shunt Trip coil with plunger assembly [Aux voltage: 110 V DC] | item3 | 1 | Nos |
|---|
| 4 | 4 | Fuse HRC link 10 A | item4 | 1 | Nos |
|---|
| 5 | 5 | HRC Fuse Base 32 A | item5 | 1 | Nos |
|---|
| 6 | 6 | Spur Gear Big | item6 | 1 | Nos |
|---|
| 7 | 7 | Spur gear Small | item7 | 1 | Nos |
|---|
| 8 | 8 | Pole Assambly (Barrier, Vacuum Interrupter & Upper-Lower Bus bar) | item8 | 1 | Nos |
|---|
| 9 | 9 | Epoxy Barrier | item9 | 1 | Nos |
|---|
| 10 | 10 | Vacuum Interrupter | item10 | 1 | Nos |
|---|
| 11 | 11 | Roof Bushing | item11 | 1 | Nos |
|---|
| 12 | 12 | Roof Bushing with copper stem & Assembly | item12 | 1 | Nos |
|---|
| 13 | 13 | Wiring of Trolley | item13 | 1 | Nos |
|---|
| 14 | 14 | Operating Mechanism, (spring charged store energy) | item14 | 1 | Nos |
|---|
| 15 | 15 | Spring charging motor mechanism, | item15 | 1 | Nos |
|---|
| 16 | 16 | Ammeter Selector switch | item16 | 1 | Nos |
|---|
| 17 | 17 | Breaker Auxiliary switch [Contact: 6 NO+ 6 NC] , | item17 | 1 | Nos |
|---|
| 18 | 18 | Breaker Auxiliary switch [Contact: 8 NO+ 8 NC] , | item18 | 1 | Nos |
|---|
| 19 | 19 | Voltmeter [Type: Analog, Size: 96x96 Sq.mm] (Range: 0-15 KV) | item19 | 1 | Nos |
|---|
| 20 | 20 | Ammeter (96x96 Sq.mm) Range: 0-100-200-400/5A | item20 | 1 | Nos |
|---|
| 21 | 21 | Test Terminal Block Rear Connection | item21 | 1 | Nos |
|---|
| 22 | 22 | Relay Test Terminal Block | item22 | 1 | Nos |
|---|
| 23 | 23 | Breaker Control Switch | item23 | 1 | Nos |
|---|
| 24 | 24 | Trivector Meter (TVM), AC HT Static meter suitable for 3 ph 4 wire unbalanced load [CT Ratio: 100-200-400/5A PTR: 11 KV/110 Volt] | item24 | 1 | Nos |
|---|
| 25 | 25 | Numerical Relay 3 O/C & 1 E/F, Make _____ | item25 | 1 | Nos |
|---|
| 26 | 26 | Current Transformer [Ratio: 400-200-100/5-5A, STC: 16 KA Protection core:5P/15 VA, Metering core: 0.5S/15 VA] | item26 | 1 | Nos |
|---|
| 27 | 27 | Indoor single phase resin cast Potential Transformer, Ratio: 11 KV/110 Volt, Burden: 100 VA, | item27 | 1 | Nos |
|---|
| 28 | 28 | PT Primary Fuse [ Rating: 11KV, 3.15 Amp, | item28 | 1 | Nos |
|---|
| 29 | 29 | Jaw Contact / Disconnecting contact [ Ratio: 630 Amp & above] | item29 | 1 | Nos |
|---|
| 30 | 30 | Charging Link With Assembly for BB1-3 | item30 | 1 | Nos |
|---|
| 31 | 31 | Epoxy Post Insulator | item31 | 1 | Nos |
|---|
| 32 | 32 | Wiring of Trolley , Type:RB1-3 | item32 | 1 | Nos |
|---|
| 33 | 33 | Power Factor meter | item33 | 1 | Nos |
|---|
| 34 | 34 | Shunt Trip coil with plunger assembly, Aux voltage: 110 VDC | item34 | 1 | Nos |
|---|
| 35 | 35 | Bridge Rectifier | item35 | 1 | Nos |
|---|
| 36 | 36 | Power Pack 100Watt ,110VDC | item36 | 1 | Nos |
|---|
| 37 | 37 | Upper terminal-L type | item37 | 1 | Nos |
|---|
| 38 | 38 | Middle terminal-L type | item38 | 1 | Nos |
|---|
| 39 | 39 | Earthing bus bar L TYPE [50x6 mm Copper] | item39 | 1 | Nos |
|---|
| 40 | 40 | Copper flexible bus bar | item40 | 1 | Nos |
|---|
| 41 | 41 | PT Jumper | item41 | 1 | Nos |
|---|
| 42 | 42 | Middle terminal-pad | item42 | 1 | Nos |
|---|
| 43 | 43 | Top Terminal Pad | item43 | 1 | Nos |
|---|
| 44 | 44 | Limit Switch/Micro Switch | item44 | 1 | Nos |
|---|
| 45 | 45 | Toggle Switch | item45 | 1 | Nos |
|---|
| 46 | 46 | Door Switch | item46 | 1 | Nos |
|---|
| 47 | 47 | 32 pin Plug Socket | item47 | 1 | Nos |
|---|
| 48 | 48 | Push Button-Black Shroud | item48 | 1 | Nos |
|---|
| 49 | 49 | Local-Remote Switch | item49 | 1 | Nos |
|---|
| 50 | 50 | Terminal Connector | item50 | 1 | Nos |
|---|
| 51 | 51 | Indication Lamp | item51 | 1 | Nos |
|---|
| 52 | 52 | Antipumping Relay | item52 | 1 | Nos |
|---|
| 53 | 53 | Heater | item53 | 1 | Nos |
|---|
| 54 | 54 | Thermostate | item54 | 1 | Nos |
|---|
| 55 | 55 | Labour Charges per breaker for inspection & fixing of required spare parts to put defective breaker in operating condition will be payable once for next twelve months from the date of repair | item55 | 1 | Nos |
|---|