Special Repair/Replacement Of Existing Perimeter Security Light And Conventional Lights Into Led Lights And Connected Items , Spl Repair/Replacement Of Lt Overhead Line Into Ab Cable , Spl Repair/Replacement Of Old Unsv Water Under Ge South Akhnoor, GE SOUTH AKHNOOR-Jammu And Kashmir

Military Engineer Services-MES has published Special Repair/Replacement Of Existing Perimeter Security Light And Conventional Lights Into Led Lights And Connected Items , Spl Repair/Replacement Of Lt Overhead Line Into Ab Cable , Spl Repair/Replacement Of Old Unsv Water Under Ge South Akhnoor. Submission Date for this Tender is 08-07-2021. LED Light Tenders in GE SOUTH AKHNOOR Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

28140964
Corrigendum : Special Repair/Replacement Of Existing Perimeter Security Light And Conventional Lights Into Led Lights And Connected Items , Spl Repair/Replacement Of Lt Overhead Line Into Ab Cable , Spl Repair/Replacement Of Old Unsv Water Under Ge South Akhnoor
Open Tender
Indian
Jammu And Kashmir
GE SOUTH AKHNOOR
08-07-2021

Tender Details

special Repair/Replacement Of Existing Perimeter Security Light And Conventional Lights Into Led Lights And Connected Items , Spl Repair/Replacement Of Lt Overhead Line Into Ab Cable , Spl Repair/Replacement Of Old Unsv Water Under Ge South Akhnoor

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Jun-2021 BOQCORRIGENDUM01 BOQ 28-06-2021
2 28-Jun-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-07-2021
3 02-Jul-2021 CORRIGENDUM012122 Financial Bid 05-07-2021
4 06-Jul-2021 DATECORRIGENDUM012122 Date 08-07-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 85000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Spl repair/replacement of existing perimeter security light and conventional lights into LED lights and connected items, spl repair/replacement of LT overhead line into AB cable, spl repair/replacement of old unsv water supply pipe line, spl repair/replacement of electric panel/main panel and connected items, spl rep of re-wiring in bldg No P-10 & P-12 cook House and dining hall, provn of LED security lights, provn of 25 Desert coolers and other sanctioned works in the AOR of AGE E/M under GE (S) Akhnoor.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge. 47 Per Point
2 2 Point wiring (concealed to surfaces) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. 35 Per Point
3 3 Description all as serial item No- 2.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board. 6 Per Point
4 4 Description all as per serial item No- 2.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board. 31 Per Point
5 5 Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. 6 Per Point
6 6 Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge. 47 Each
7 7 Switch piano, flush type, single pole, one way, 15 Amps, complete all as specified and as directed by Engineer-In-Charge. 6 Each
8 8 Socket outlet, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge. 12 Each
9 9 Socket outlet, 2-in-1, 3-pin, 5 and 15 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge. 6 Each
10 10 Switch socket combination 2-in-1, 3-pin, 5 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge. 25 Each
11 11 Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge. 35 Each
12 12 Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge. 14 Each
13 13 T bulb curve, 12 Watt LED base B22 cool day light, complete all as specified and as directed by Engineer-In-Charge. 14 Each
14 14 Stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge. 2 Each
15 15 Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 12-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed. 2 Each
16 16 MCB, Single Pole and Neutral, 40-63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge. 4 Each
17 17 MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge. 8 Each
18 18 S&F in replacement of LED security/ street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection, including LED lamps of 30 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified.\nMake: Havells cat part No- Endura Citylite Platinum Plus SL30WLED757SASYBOPC/ Bajaj ordering code No- 169907 (Product Code- BRLEP 30W LED WH)/ Philips ordering code No- 910925452299 (Product Code- 871869632003700). 4 Each
19 19 Sub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge. 124 Per Running Metre
20 20 Description all as serial item No- 19.00 here-in-before but for sub main wiring (in new conduits concealed to surfaces) alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts. 110 Per Running Metre
21 21 S&F in replacement of Ceiling fan, mettalic, sweep 1200mm, superior rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers and connectig wire of suitable size and length, complete all as specified and as directed.\nMake: Havells cat part No- FHCES5SWHT48/ Crompton Greaves Entrust 50/ Usha Ergo/ Bajaj Electra 50/ Orient Electric energy star\n 2 Each
22 22 Exhaust fan, mettalic, sweep 250/ 230mm, superior rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers, complete all as specified.\nMake: Havells cat part No- FHVDBMTGRY09 (Ventilair DB Neo)/ Crompton Greaves/ Usha/ Bajaj/ Orient. 1 Each
23 23 Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 2.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge. 65 Per Running Metre
24 24 Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, for laying pipe line etc, complete all as specified and as directed by Engineer-In-Charge.\nNote :-The quoted rate shall be deemed to have included necessary "trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete complete including necessary all tools, tackles etc. 40 Cum
25 25 Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, for foundations/ laying of cables/pipes, complete all as specified and as directed by Engineer-In-Charge. 48 Cum
26 26 Excavation in trenches, not exceeding 1.50 mtr wide and exceeding 1.50mtr but not exceeding 3.0mtrs in depth, not exceeding 10 Sqm on plan and not exceeding 3.0 mtr in depth and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge. 0.6 Cum
27 27 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge. 48.6 Cum
28 28 Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge. 40 Cum
29 29 Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge.\nNote: Punned thickness shall be measured. 8.4 Cum
30 30 Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified. 0.95 Per 1000 Nos
31 31 S& F in replacement of Factory made LT electrical panel board in repair indoor type AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, cubical indoor type, fabricated with 3.40 mm thick made mild steel sheet /CRCA (1200mmx1500mmx450mm), powder coated , CPRI Approved , bottom with detachable plates, front and rear with hinged type double door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars 4 Nos, 300 amps capacity insulated with colored PVC sleeves mounted on frame of mild steel angle iron 25x25x5mm, 30Cm above from the ground level duly supported with mild steel angle iron 40x40x5mm, embedded in Plain Cement Concrete M-10 (1:3:6), type C-1 (using 20mm graded crushed stone aggregates) 300mm below the ground level and required masonry in brick work in cement mortar 1:6 incl suitable insulators and separators, holes drilled for connections, complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete all as specified and comprising of the followings:-\nOUTGOING :-\n(a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 25 KA - 02 No. \n(b) MCB 2 Pole, 415 V, 20 Amp rating with sensitivity of 30 MA - 02 No. \n(c) Change over switch on load 415 volts TPN in sheet metal enclosure of capacity 100 Amps -01 No\n(d) Astronomical timer switch including panel, contactor rating 32 Amps, Triple Pole-01 No \nINCOMING :-\n(e) MCCB 4 Pole, 415 V, Thermal Magnetic type, 125 Amps with breaking capacity 25 KA - 01 No\n(f) AC Three phase static energy meter of accuracy class 1.0 ,3 X 240 V ,50 Hz with Backlit LCD display of rating 10 - 60 A (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical \ncommunication port display in absence of power with transparent hinge type box-01 Nos \n(g) Phase indication lamps - 3 Nos. 2 Each Job
32 32 S& F in replacement of Factory made LT electrical panel board in repair outdoor type AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, cubical indoor type, fabricated with 3.40 mm thick made mild steel sheet /CRCA (1200mmx1500mmx450mm), powder coated , CPRI Approved , bottom with detachable plates, front and rear with hinged type double door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars 4 Nos, 400 amps capacity insulated with colored PVC sleeves mounted on frame of mild steel angle iron 25x25x5mm, 30Cm above from the ground level duly supported with mild steel angle iron 40x40x5mm, embedded in Plain Cement Concrete M-10 (1:3:6), type C-1 (using 20mm graded crushed stone aggregates) 300mm below the ground level and required masonry in brick work in cement mortar 1:6 incl suitable insulators and separators, holes drilled for connections, complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete all as specified and comprising of the followings:-\nOUTGOING :-\n(a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 25 KA - 04 No. \n(b) MCB 2 Pole, 415 V, 20 Amp rating with sensitivity of 30 MA - 02 No. \n(c) Change over switch on load 415 volts TPN in sheet metal enclosure of capacity 100 Amps -01 No \nINCOMING :-\n(d) MCCB 4 Pole, 415 V, Thermal Magnetic type, 160 Amps with breaking capacity 25 KA - 01 No\n(e) AC Three phase static energy meter of accuracy class 1.0 ,3 X 240 V ,50 Hz with Backlit LCD display of rating 10 - 60 A (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical \ncommunication port display in absence of power with transparent hinge type box-01 Nos \n(f) Phase indication lamps - 3 Nos.\n(g) Capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 20 KVAR capacity -01 No 2 Each Job
33 33 S&F in replacement of earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 32x6 mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. \nNOTE :- (i) Item of earthing includes cost of 7.5 m long GI strip of size 32x6mm with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by 25%.\n(ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.\n 4 Each Job
34 34 S&F in replacement of earthing complete as per electrical plate No 5 of MES SSR Part-I with galavanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 M below normal ground level connected to and including galvanised earth lead wire 4.0mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing lead shall be protected by galvanised iron or steel pipe 20mm bore light grade and connected to continuous earth wire on pole/test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcol, salt, funnel PCC pit and RCC cover complete all as specified & tested complete all as specified.\nNote : 1. Following items deemed to bed included in quoted rate\n(a) Earth electrode \n(b) Main earth lead from earth electrode to test point and further to equipment to be earthed upto 7.5 Mtr \n(c) M&L for connecting earth electrode and earth lead as specified \n(d) Adequate qty of charcol, dust and common salt as per direction. \n(e) All labour involved incl testing of earth network \n(f) Excavation and earth work or drilling hole for electrode \n(g) PCC pit and CI cover \n(h) Funnel with wtering pipe, wiremesh and copper lugs etc as specified \n(j) GI protection pipe of size as specified for protection of earth lead from mechanical injury or tempring.\n2. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. 12 Each set
35 35 S&F in replacement of SMC FRP junction Box, sliding door fixed to base by means of ssliding, pole monunting arrangeemnt, maint free, fire retardent, pilferage proof for entry the cable from side and bottom of size 340x160x90mm with aluminium bus bar for street lighting of 3 phasse/ 4 core complete all as specified and directed. Make: sintex GS-JB-3416 or equivelent in Havells/L&T. 130 Each
36 36 Factory made SMC junction box/ cut-out box, made with 3.15mm thick CRCA mild steel sheet, vermin proof, dust proof, for outdoor use, having internal dimensions 400x300x190, painted externally and internally, suitable for road/ street lighting for 3-phase/ 4-core high wattage LED based lighting system for industrial applications, suitable for pole mounting, having one No MCB of 15 Amps, Single Pole and Neutral, including aluminium bus bars of 200 Amps rating duly drilled holes for connections, cable glands, clamps etc for making necessary connections, including mild steel iron flat size 25x4mm having holes, nuts, bolts, washers, for fixing on poles, complete all as specified and directed by Engineer-In-Charge.\nMake: Sintex cat part No GS-JB-4030 or equivelent in Havells/L&T. 6 Each
37 37 S&F in replacement of Arial bunched cable, 1.10 KV, nominal cross sectional area 35.0 Sqmm, consisting five single core (Four Phase and one neutral), sizes 4x35Sqmm+16Sqmm, each core screened by an extruded, semi-conducting cable, XLPE insulated and screened again by semi-conducting layer and aluminium tape and XLPE insulation, phase identification tape, twisted around one bared ACSR conductor as messenger made out of aluminium and mild steel alloy and over all PVC or polythene sheathed, stretching the cable on existing poles with mild steel clamps, nuts, bolts and washers, cable ends/ straight through joints, tee junctions as required at site, complete all as specified and as directed by Engineer-In-Charge.\nMake: Havells/ Poycab/ Finolex/ Paragon/ Cable corporation of India. 1200 Per Running Metre
38 38 S&F Arial bunched cable, 1.10 KV, nominal cross sectional area 150.0 Sqmm, consisting five single core (Four Phase and one neutral), sizes 4x150Sqmm+95Sqmm, each core screened by an extruded, semi-conducting cable, XLPE insulated and screened again by semi-conducting layer and aluminium tape and XLPE insulation, phase identification tape, twisted around one bared ACSR conductor as messenger made out of aluminium and mild steel alloy and over all PVC or polythene sheathed, stretching the cable on existing poles with mild steel clamps, nuts, bolts and washers, cable ends/ straight through joints, tee junctions as required at site on existing poles, complete all as specified and as directed by Engineer-In-Charge.\nMake: Havells/ Poycab/ Finolex/ Paragon/ Cable corporation of India. 625 Per Running Metre
39 39 S&F in replacement of Arial bunched cable, 1.10 KV, nominal cross sectional area 25.0 Sqmm, consisting five single core (Four Phase and one neutral), sizes 4x25Sqmm+16Sqmm, each core screened by an extruded, semi-conducting cable, XLPE insulated and screened again by semi-conducting layer and aluminium tape and XLPE insulation, phase identification tape, twisted around one bared ACSR conductor as messenger made out of aluminium and mild steel alloy and over all PVC or polythene sheathed, stretching the cable on existing poles with mild steel clamps, nuts, bolts and washers, cable ends/ straight through joints, tee junctions as required at site, complete all as specified and as directed by Engineer-In-Charge.\nMake: Havells/ Poycab/ Finolex/ Paragon/ Cable corporation of India. 3705 Per Running Metre
40 40 S&F Inverter Based street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection, including LED lamps of 45 Watt including taking down old conventional secuirty lights of any type amd description and connecting up with twin core twisted flexible copper conductor cable of suitable size, including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified.\nMake: Make: Hellonix Cat Part No HLSLD-ML-04-45-CWL-INV-RTC-R or Equivalent makes in Bajaj/Philips/Havells/Crompton 130 Each
41 41 S&F in replacement of old cracked/ damaged, concrete poles with new pre-stressed concrete pole, 9.0 metres long, cross section 102mmx172mm at top and 102mmx279mm at bottom, class 10, including painting strips in black and white colour, 300mm thick, upto 1.50mtr height, from top of PCC coping with synthetic enamel paint after preparing the surface, complete all as specified and as directed by Engineer-In-Charge. \nNote: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ. 7 Each
42 42 S&F concrete poles with new pre-stressed concrete pole, 9.0 metres long, cross section 102mmx172mm at top and 102mmx279mm at bottom, class 10, including painting strips in black and white colour, 300mm thick, upto 1.50mtr height, from top of PCC coping with synthetic enamel paint after preparing the surface, complete all as specified and as directed by Engineer-In-Charge. \nNote: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ. 6 Each
43 43 LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection, including LED lamps of 45 Watt and connecting up with twisted flexible copper conductor cable of 2.50 sqmm 2 core size from jucntion box to street light including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified, complete all as specified.\nMake: Havells cat part No- Endura Pearl Neo SL45WLED757SASYTOPC/ Philips ordering code No- 910925866055 (Product Code- 871869634894900)/ Bajaj ordering code No- 169799 (Product Code- BRTFG 45W LED I). 6 Each
44 44 Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 50.0 Sqmm, 3.50-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge. 83 Per Running Metre
45 45 GI pipes/ Tubes, 'light grade', galvanised, 40mm bore, ISI marked, laid in trenches or fixed to walls/ poles with mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed by Engineer-In-Charge. 4.5 Per Running Metre
46 46 LED retrofit lamp, capacity 9 Watt, B-22 holder base with ploycarbonate body and aluminium heat sink, warm/ white light, including taking down old conventional lights of any descritpion and of any type, complete all as specified and as directed by Engineer-In-Charge.\n 930 Each
47 47 LED tube light fitting, 18 watt, indoor decorative aluminium extruded T5 LED battens, including LED lamp 18 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, including taking down old conventional lights of any descritpion and of any type, complete all as specified and as directed by Engineer-In-Charge.\n\nMake: Havells cat part No- E-Lite LED Pride Plus Neo LHEXBTP7IN1W018/ Crompton cat part LCTL-18-CDL/ Bajaj product code-12410, luminaire type- BCLSB 18 NW. 744 Each
48 48 Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge. 5.9 Cum
49 49 Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of poles including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge. 0.6 Cum
50 50 Astronomical timer switch including panel, contactor rating 63 Amps, Triple Pole, MCB 63 Amps, Single Pole and Neutral, complete all as specified and as directed by Engineer-In-Charge.\nduly mounted on poles, walls with metMake: Havells cat part No- IHXSS03120 or equivalent in Legrand/ ABB/ Merlin Gerin/ Siemens. 1 Each
51 51 Air conditioner, split type, single phase, capacity 1.50 Ton, 230 Volts, rated cooling capacity 5000, five star rating in power savings, with refrigerant R-22, noise level below 54 db, complete all as specified and as directed by Engineer-In-Charge.\nMake: Voltas/ Carrier/ Blue Star/ Daiken/ Hitachi. 2 Each
52 52 Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for and including incorporating MCBs SPN-30 Amp-01 No, IP-43, 2-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed. 2 Each
53 53 Taking up unserviceable cast iron/ galvanised iron/ ductile iron water mains (including all fittings) of 100mm bore, with spigot and socket/ flanged ends and lead joints including burning out joints and recovering lead, complete all as specified and directed by Engineer-In-Charge. 150 Per Running Metre
54 54 Taking up unserviceable cast iron/ galvanised iron/ ductile iron water mains (including all fittings) of 80mm bore, with spigot and socket/ flanged ends and lead joints including burning out joints and recovering lead, complete all as specified and directed by Engineer-In-Charge. 100 Per Running Metre
55 55 Taking up unserviceable cast iron/ galvanised iron/ ductile iron water mains (including all fittings) of 40mm bore, with spigot and socket/ flanged ends and lead joints including burning out joints and recovering lead, complete all as specified and directed by Engineer-In-Charge. 120 Per Running Metre
56 56 Taking up unserviceable cast iron/ galvanised iron/ ductile iron water mains (including all fittings) of 20mm bore, with spigot and socket/ flanged ends and lead joints including burning out joints and recovering lead, complete all as specified and directed by Engineer-In-Charge. 40 Per Running Metre
57 57 Tubes, 'medium grade' galvanised, 100mm bore, ISI marked including all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches or fixed on walls, complete all as specified and as directed by Engineer-In-Charge. 150 Per Running Metre
58 58 Tubes, 'medium grade' galvanised, 80mm bore, ISI marked including all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches or fixed on walls, complete all as specified and as directed by Engineer-In-Charge. 100 Per Running Metre
59 59 Tubes, 'medium grade' galvanised, 40mm bore, ISI marked including all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches or fixed on walls, complete all as specified and as directed by Engineer-In-Charge. 120 Per Running Metre
60 60 Tubes, 'medium grade' galvanised, 20mm bore, ISI marked including all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches or fixed on walls, complete all as specified and as directed by Engineer-In-Charge. 40 Per Running Metre
61 61 Tubes, 'medium grade' galvanised, 15mm bore, ISI marked including all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches or fixed on walls, complete all as specified and as directed by Engineer-In-Charge. 100 Per Running Metre
62 62 Replacement old un-serviceable Sluice Valve with new Sluice Valve, cast iron, Class PN 1.6, size 150mm bore pipe, flanged type, conforming to IS: 14846-2000, ISI marked with stainless steel spindle, brass nuts and iron wheel head including jointing material such as rubber fibre board packing ring and nuts, bolts and washers of suitable size for vertical or horizintal fittings, complete all as specified and as directed by Engineer-In-Charge. 1 Each
63 63 Replacement old un-serviceable Sluice Valve with new Sluice Valve, cast iron, Class PN 1.6, size 80mm bore pipe, flanged type, conforming to IS: 14846-2000, ISI marked with stainless steel spindle, brass nuts and iron wheel head including jointing material such as rubber fibre board packing ring and nuts, bolts and washers of suitable size for vertical or horizintal fittings, complete all as specified and as directed by Engineer-In-Charge. 1 Each
64 64 Construction of brick masonry valve pit of size 900x900x900mm (internal dimensions of chamber) including plain cement concrete, M-7.5 (1:4:8), type-D2 (using 40mm graded crushed stone aggregates) 100mm thick, as in sub base and PCC M-15 (1:2:4), type-B2 (using 40mm graded crushed stone aggregates) 100mm thick, as in flooring, brick work masonry, 23cm thick in cement mortar 1:4, rendering 15mm thick in cement mortar 1:4 on internal and external surfaces with two coat of lime wash, mild steel framed work as in valve pit covers with angle iron frame 50x50x6mm and including mild steel sheet cover 3.15mm thick complete, drilling/ welding for fixing of steel sheeting with mild steel hinges, handles and suitable locking arrangements, fastening arrangements for fixing, nuts, bolts and washers including painting with two coats of synthetic enamel paint over a coat of red oxide primer, including excavation in any type of soil, returning filling in external areas and removal the surplus soil to a distance of not exceeding 50mtrs, complete all as specified and as directed by Engineer-In-Charge. 1 Each Job
65 65 Replacement old un-serviceable gate valve with new gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 40mm bore pipe line, complete all as specified and as directed by Engineer-In-Charge. 1 Each
66 66 Replacement old un-serviceable gate valve with new gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20mm bore pipe line, complete all as specified and as directed by Engineer-In-Charge. 1 Each
67 67 Gate valve with new gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 15mm bore pipe line, complete all as specified and as directed by Engineer-In-Charge. 25 Each
68 68 Desert cooler, electric driven copper wounded motor, single phase, 450mm metallic sweep cooler fan, 1400 rpm, 230 Volt, 50 Hz, air delivery capacity 4500 Cum/Hr, three speed regulator (high/medium/low) with metallic blade and mild steel body, duly painted with synthetic anti-corrosive oven cured paint, submersible pump 40 Watt (approx.), 230 Volts, 50 Hz and including wood wool pad of proper thickness and 2.50Sqmm three core copper wire with connecting top plug including steel work using Angle iron and flat members of appropriate height in stand and making necessary arrangements for fixing of stand in wall by making holes and PCC/mortar work for grouting and making good disturbed surfaces and apply same finishes as exsiting, complete all as specified and as directed by Engineer-In-Charge.\nMake of motor: Khaitan/ Usha Lexus/ Orient/ Crompton.\nNote : Cost of steel and framed work shall deem to be included in the quoted rates. 25 Each
69 69 Dismantling of ACSR or AAC conductors, complete all as specified and as directed by Engineer-In-Charge. 3 Per Quintal
70 70 Dismantling of insulators of any type and any description, complete all as specified and as directed by Engineer-In-Charge. 50 Each
71 71 Replacement of old unserviceable/ damaged Mild steel in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint, complete all as specified and as directed by Engineer-In-Charge. 1 Per Quintal
72 72 Replacement of old unserviceable/ damaged stay assembly with new stay assembly, galvanised iron, complete with accessories as shown in electrical plate No-1, diameter of stay rod 20mm dia, including galvanised iron stay plate 300x300x6mm, galvanised iron thimble, 14mm dia 400mm long stay bow and galvanised iron nuts bolts, washers including loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 65x90mm, clearance of hole 16.0mm, including stay wire, galvanised iron, stay wire 7/4mm stranded, complete all as specified and as directed by Engineer-In-Charge.\nNote: Excavation, earth work and PCC shall be measured and paid separately under relevant item of Schedule ‘A’/ BOQ. 4 Each Set
73 73 Amount of Schedule of credit of for Rs 2,36,688.00 shall be deducted from quoted amount.