Kochi Metro Rail Limited has published Supply , Fabrication And Installation Of Signages And Graphics ( Package 2 ) At Vytilla And Kakkanad For Kochi Water Metro Project. Submission Date for this Tender is 22-06-2021. Fabrication Work Tenders in Kochi Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 10-Jun-2021 | Note | Other | 22-06-2021 |
Name of Work: Supply and Installation Works (Including Fabrication) of Signage and Graphics including all transportation, loading and unloading, etc. for Two Terminal Water Metro Stations viz., Kakkanad and Vyttila of Kochi Water Metro Project. (Package -2) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Signages | |||
2 | 1.01 | Suspended sign, Illuminated, 2 sided \nSuspended\nDwg No. 1.1.1a,b,c\nwith Sign Box, Bilingual text panel - Illuminated surface, Pictogram panel - Illuminated surface, Illumination all as per\nItem Ref No. : 1.1.1a as per detailed BOQ and technical specifications\nInterior Direction Sign - Size 1500 x 300 | item1 | 1 | Nos |
3 | 1.02 | Suspended sign, Illuminated, 2 sided \nSuspended\nDwg No. 1.1.1a,b,c\nwith Sign Box, Bilingual text panel - Illuminated surface, Pictogram panel - Illuminated surface, Illumination all as per\nItem Ref No. : 1.1.1b as per detailed BOQ and technical specifications\nInterior Direction Sign - Size 600 x 300 | item2 | 2 | Nos |
4 | 1.03 | Suspended sign, Illuminated, 2 sided \nSuspended\nDwg No. 1.1.1a,b,c\nwith Sign Box, Bilingual text panel - Illuminated surface, Pictogram panel - Illuminated surface, Illumination all as per\nItem Ref No. : 1.1.1c as per detailed BOQ and technical specifications\nInterior Direction Sign - Size 1200 x 300 | item3 | 1 | Nos |
5 | 1.04 | Suspended Sign fixing : Providing and fixing suspension for the signs using MS Hollow Circular sections cut, fabricated as per drawing and All complete as per Item 1.1.1susp in detailed BOQ, technical specifications, drawings and instructions of Engineer in Charge. | item4 | 4 | Nos |
6 | 1.05 | Suspended sign, Illuminated, 2 sided, double height\nSuspended\nDwg No. 1.1.2 a,b,c\nwith Sign Box, Sign panel - 2 side Illuminated face, Illumination all as per Item 1.1.2a of the detailed BOQ and technical specifications\nSize 1500 x 600 | item5 | 1 | Nos |
7 | 1.06 | Suspended Sign fixing : Providing and fixing suspension for the signs using MS Hollow Circular sections cut, fabricated as per drawing and All complete as per Sl No. 2.02 Item 1.1.2susp in detailed BOQ, technical specifications, drawings and instructions of Engineer in Charge. | item6 | 1 | Nos |
8 | 1.07 | Post Mounted Sign, Retroreflective, 2 sided\nPost mounted\nDwg. No. 1.1.8a,b,c\nwith Sign Box, Sign panel - 2 side Non-Illuminated face all as per Item 1.1.8a of the detailed BOQ and technical specifications. \nDirection Vicinity sign(Retro Reflective) - Size 1350 x 450 | item7 | 17 | Nos |
9 | 1.08 | Post with Foundation and Pedestal\nProviding a Sign post of 80mm dia NB 5 mm thick MS hollow sections including welded Base plate in 8mm thick MS Plate and as per drawing with Concrete footing with Foundation and Pedestal all complete as per Sl No.3.02 Item 1.1.8Post in detailed BOQ, technical specifications, drawings and instructions of Engineer in Charge. | item8 | 17 | Nos |
10 | 1.09 | Post Mounted Sign, Non-Illuminated, 2 sided, (Double Height), Post mounted\nDwg No. 1.1.100a,b,c\nwith Sign Box(Double Height), Sign panel - 2 side Non-Illuminated face all as per\nItem Ref No. : 1.1.1b as per detailed BOQ and technical specifications.\nSign Size - 1200 x600 | item9 | 2 | Nos |
11 | 1.1 | Post with Foundation & Pedestal :\nProviding a Sign post of 80mm dia NB 5 mm thick MS hollow sections including welded Base plate in 8mm thick MS Plate and as per drawing with Concrete footing with Foundation and Pedestal all complete as per Sl No.4.02 Item 1.1.10Post in detailed BOQ, technical specifications, drawings and instructions of Engineer in Charge. | item10 | 2 | Nos |
12 | 1.11 | Suspended Sign, Non-Illuminated, 2sided, single Height,Suspended\nDwg No. 2.1.1a,b,c\nwith Sign Box and Sign panel - 1 side non-Illuminated face all as per Item 2.1.1a of the detailed BOQ and technical specifications\nSize 300 x 500 | item11 | 2 | Nos |
13 | 1.12 | Suspended Sign, Non-Illuminated, 2sided, single Height,Suspended\nDwg No. 2.1.1a,b,c\nwith Sign Box and Sign panel - 1 side non-Illuminated face all as per Item 2.1.1b of the detailed BOQ and technical specifications\nSize 550 x 500 | item12 | 2 | Nos |
14 | 1.13 | Suspended Sign fixing : Providing and fixing suspension for the signs using MS Hollow Circular sections cut, fabricated as per drawing and All complete as per Sl. No.5.03 Item 2.1.1susp in detailed BOQ and technical specifications, drawings andd instructions of Engineer-in-charge. | item13 | 4 | Nos |
15 | 1.14 | Suspended Sign, Non-Illuminated, 2sided, single Height,Suspended\nDwg. No. 2.1.2a,b,c\nwith Sign Box, Sign panel - 1 side non-Illuminated face all as per Item 2.1.2a of the detailed BOQ and technical specifications\nSign Size - 550 x 500 | item14 | 8 | Nos |
16 | 1.15 | Suspended Sign fixing : Providing and fixing suspension for the signs using MS Hollow Circular sections cut, fabricated as per drawing and All complete as per Sl.No.6.02 Item 2.1.2susp of detailed BOQ and technical Specifications. | item15 | 8 | Nos |
17 | 1.16 | Post mounted sign(picto), Retroreflective,2-sided, Post mounted\nDwg No. 2.1.6a,b,c\nwith Sign Box, Sign panel - 1 side non-Illuminated face all as per Item 2.1.6a of the detailed BOQ and technical specifications\n\nDrop-off point sign Size - 325 x 300 | item16 | 4 | Nos |
18 | 1.17 | Post with Foundation & Pedestal:\nProviding a Sign post of 60mm dia MS hollow sections including welded Base plate in 8mm thick MS Plate as per drawing with Concrete footing.and all comlete with Foundation and Pedestal all as per Sl.No.7.02 Item 2.1.6Post in detailed BOQ, technical specifications, drawings and instrcutions of Engineer in charge. | item17 | 4 | Nos |
19 | 1.18 | Totem Sign, Illuminated, 2 sided Post mounted\nDwg No. 4.4a,b,c\nwith Sign Structure, illumination all as per Item 4.4a of the detailed BOQ and technical specifications\n\nStation Identification sign Size- 1250 x 4000 | item18 | 2 | Nos |
20 | 1.19 | Totem Sign, Illuminated, 2 sided Post mounted\nDwg No. 4.4a,b,c\nwith Sign Structure, illumination all as per Item 4.4a of the detailed BOQ and technical specifications\nStation Identification sign Size- 1250 x 3100 | item19 | 1 | Nos |
21 | 1.2 | Post(Foundation) and Pedestal arrangement\nFixing the Entire Totem Sign on Floor, with 5mm thick MS plate into Concrete. The entire post assembly shall be painted in PU paint to match colour Grey as specified and approved by the Engineer-In-charge. All complete as per 4.4Post in detailed BOQ and technical specifications | item20 | 3 | Nos |
22 | 1.21 | Suspended Sign, Non-Illuminated, 2sided, single Height,Suspended\nDwg No. 2.1.9\nwith Sign Box and Sign panel - 1 side non-Illuminated face all as per Sl No.9 Item 2.1.9 of the detailed BOQ and technical specifications\nSign Size - 1500 x 450 | item21 | 4 | Nos |
23 | 1.22 | Suspended Sign fixing : Providing and fixing suspension for the signs using MS Hollow Circular sections cut, fabricated as per drawing and All complete as per Sl.No.9.02 Item 2.1.9susp in detailed BOQ, technical specifications, drawings and instructions of Engineer in charge. | item22 | 4 | Nos |
24 | 1.23 | Door signs, non-illuminated, 1 sided Face mounted\nDwg No. 2.5a,b,c\nwith Sign frame all as per Sl No.10 Item 2.5 of the detailed BOQ and technical specifications\nDoor names of size - 225 x 150 | item23 | 16 | Nos |
25 | 1.24 | Face mounted sign, non-illuminated\nFace Mounted \nDwg No. 3.1.1a,b,c\nwith sign frame and Graphics all as per Sl No.11 Item 3.1.1 of the detailed BOQ and technical specifications\nSign Size - 594 x 841 | item24 | 2 | Nos |
26 | 1.25 | Face mounted sign, non-illuminated\nFace Mounted \nDwg No. 3.1.1a,b,c\nwith sign frame and Graphics all as per Sl No.11 Item 3.1.1 of the detailed BOQ and technical specifications\nSign Size - 1250 x 900 | item25 | 3 | Nos |
27 | 1.26 | Face mounted sign, non-illuminated\nFace Mounted \nDwg No. 3.1.1a,b,c\nwith sign frame and Graphics all as per Sl No.11 Item 3.1.1 of the detailed BOQ and technical specifications\nSign Size - 1189 x 841 | item26 | 1 | Nos |
28 | 1.27 | Sign Mounting : Face :The sign mounting frame made up of 40x40x5mm MS Equal angles as a frame back to back provided with welded angle cleats plates in 40x40x5mm MS Equal angles along the perimeter of frame with slots to receive the rivets to fix the sign frame as per drawing . Complete mounting frame including channel supports are to be PU painted to match GreyG2 of approved make and duly approved by Engineer-in-Charge. >> All complete as per Sl No. 11.04 Item No. 3.1.1face of detailed BOQ and technical specifications, drawings and instructions of Engineer in charge. | item27 | 6 | Nos |
29 | 1.28 | Post Mounted Sign, 1 sided, Non-Illuminated, Post mounted,\nDwg No. 3.1.2a,b,c \nwith Sign Fram and Graphics all as per Sl No. 12.01 item 3.1.2 of detailed BOQ and Technical Specifications\nArea map/system map of size - (1189 x 841) + (1189 x 841) | item28 | 3 | Nos |
30 | 1.29 | Post Mounted Sign, 1 sided, Non-Illuminated, Post mounted,\nDwg No. 3.1.2a,b,c \nwith Sign Fram and Graphics all as per Sl No. 12.01 item 3.1.2 of detailed BOQ and Technical Specifications\nArea map/system map of size - (1189 x 841) | item29 | 2 | Nos |
31 | 1.3 | Post with Foundation & Pedestal\nProviding a Sign post of 80mm dia NB 5.4mm thick MS hollow sections including welded Base plate in 8mm thick MS Plate and Gussets in 6mm thick MS Plate as per drawing with holes to fix it on holding down bolts anchored in concrete footing with Foundation and Pedestal all complete as per SL No.12.03 Item 3.1.2Post of detailed BOQ and Technical Specifications, drawings and instructions of Engineeer in charge. | item30 | 5 | Nos |
32 | 1.31 | Post Mounted Sign, 1 sided, Non-Illuminated, Single post \nDwg No. 3.1.3a,b,c\nwith Sign Frame and Graphics all as per Sl. No. 13 Item 3.1.3 of detaild BOQ and Technical Specifications.\nLine Map Size - 297 x 841 | item31 | 1 | Nos |
33 | 1.32 | Post with Foundation and Pedestal:\nProviding a Sign post of 80mm dia NB 5.4mm thick MS hollow sections including welded Base plate in 8mm thick MS Plate and Gussets in 6mm thick MS Plate as per drawing with holes to fix it on holding down bolts anchored in concrete footing with Foundation and Pedestal all complete as per Sl No.13.02 Item 3.1.3Post of detailed BOQ and Technical Specifications, drawings and instructions of th Engineer in charge. | item32 | 1 | Nos |
34 | 1.33 | Suspended sign, Illuminated, 2 sided, single height\nSuspended\nDwg No. 4.1a,b,c\nwith Sign Box, Sign panel - 2 side Illuminated face, Illumination all complete as per Sl.No. 14 Item 4.1 of detailed BOQ and Technical Specifications.\nWay to ETS at platform Sign Size - 600 x 300 | item33 | 2 | Nos |
35 | 1.34 | Suspended sign, Illuminated, 2 sided, single height\nSuspended\nDwg No. 4.1a,b,c\nwith Sign Box, Sign panel - 2 side Illuminated face, Illumination all complete as per Sl.No. 14 Item 4.1 of detailed BOQ and Technical Specifications.\nWay to ETS at platform Sign Size - 1200 x 300 | item34 | 2 | Nos |
36 | 1.35 | Suspended Sign fixing : Providing and fixing suspension for the signs using MS Hollow Circular sections cut, fabricated as per drawing and provided with connectors plates for mounting with holes and entire assembly finished in PU paint and All complete as per Sl No. 14.03 Item 4.1susp of detailed BOQ, Technical Specifications, drawings and instructions of Engineer in charge.. | item35 | 4 | Nos |
37 | 1.36 | Face mounted sign, illuminated, 1 sided\nFace mounted\nDwg No. 4.2a,b,c\nwith Sign Box, Sign panel - 1 side Illuminated face & Illumination all as per Sl No.15 Item 4.2 detailed BOQ & technical specifications\nWay to emergency exit Sign Size 600 x 300 | item36 | 2 | Nos |
38 | 1.37 | Face mounted sign, illuminated, 1 sided\nFace mounted\nDwg No. 4.2a,b,c\nwith Sign Box, Sign panel - 1 side Illuminated face & Illumination all as per Sl No.15 Item 4.2 detailed BOQ & technical specifications\nWay to emergency exit Sign Size 1200 x 300 | item37 | 2 | Nos |
39 | 1.38 | Sign Mounting : Face :The sign mounting frame made up of 40x40x5mm MS Equal angles as a frame back to back provided with welded angle cleats plates in 40x40x5mm MS Equal angles along the perimeter of frame with slots to receive the rivets to fix the sign frame as per drawing . Complete mounting frame including channel supports are to be PU painted to match GreyG2 of approved make and duly approved by Engineer-in-Charge. >> all complete as per Sl No. 15.03 Item 4.2face as per detailed BOQ, technical specifications, drawings and instrcutions of Engineer in charge. | item38 | 4 | Nos |
40 | 1.39 | Face mounted frame sign, non-illuminated,\nFace mounted\nDwg No. 3.2a,b,c\nwith Sign Box complete as per Item 3.2 of detailed BOQ and technical specifications\nSign Size - 450 x 690 | item39 | 3 | Nos |
41 | 1.4 | Face mounted frame sign, non-illuminated,\nFace mounted\nDwg No. 3.2a,b,c\nwith Sign Box complete as per Item 3.2 of detailed BOQ and technical specifications\nSign Size 450 x 375 | item40 | 2 | Nos |
42 | 1.41 | Sign Mounting : Face :The sign mounting frame made up of 40x40x5mm MS Equal angles as a frame back to back provided with welded angle cleats plates in 40x40x5mm MS Equal angles along the perimeter of frame with slots to receive the rivets to fix the sign frame as per drawing . Complete mounting frame including channel supports are to be PU painted to match GreyG2 of approved make and duly approved by Engineer-in-Charge. >> all complete as per Sl No.16.03 Item 3.2face of detailed BOQ, technical specifications, drawings and instrcutions of Engineer in charge. | item41 | 5 | Nos |
43 | 1.42 | Vinyl Sign, non-illuminated,\nFace mounted\nDwg No. 7.1a,b,c\nwith Sign Face as per Item 7.1 of detailed BOQ, technical specifications, drawings and instructions of Engineer in charge.\nSign Size - (3000x300), (2800x300), (2800x300) | item42 | 2 | Nos |
44 | 1.43 | Vinyl Sign, non-illuminated,\nFace mounted\nDwg No. 7.1a,b,c\nwith Sign Face as per Item 7.1 of detailed BOQ, technical specifications, drawings and instructions of Engineer in charge\nSign Size - (3000x300) | item43 | 1 | Nos |
45 | 1.44 | Vinyl Sign, non-illuminated,\nFace mounted\nDwg No. 7.1a,b,c\nwith Sign Face as per Item 7.1 of detailed BOQ, technical specifications, drawings and instructions of Engineer in charge\nSign Size - (325x300) | item44 | 2 | Nos |
46 | 1.45 | Vinyl Sign, non-illuminated,\nFace mounted\nDwg No. 7.1a,b,c\nwith Sign Face as per Item 7.1 of detailed BOQ, technical specifications, drawings and instructions of Engineer in charge\nSign Size - (450 x 375) | item45 | 1 | Nos |
47 | 1.46 | Vinyl Sign, non-illuminated,\nFace mounted\nDwg No. 7.1a,b,c\nwith Sign Face as per Item 7.1 of detailed BOQ, technical specifications, drawings and instructions of Engineer in charge\nSign Size - (300 x 225) | item46 | 3 | Nos |
48 | 1.47 | Print on Self Adhesive Frosted Film,\nFace mounted\nDwg No. 7.2a,b,c\nwith Sign Face as per Sl.No.18 Item 7.2 of detailed BOQ, technical specifications, drawings and instructions of Engineer in charge\nSign Size -2000 x 300 | item47 | 1 | Nos |
49 | 1.48 | Print on Self Adhesive Frosted Film,\nFace mounted\nDwg No. 7.2a,b,c\nwith Sign Face all complete as per Sl.No.18 Item 7.2 of detailed BOQ, technical specifications, drawings and instructions of Engineer in charge\nSign Size -3000 x 300 | item48 | 1 | Nos |
50 | 1.49 | Print on Self Adhesive Frosted Film,\nFace mounted\nDwg No. 7.2a,b,c\nwith Sign Face all complete as per Sl.No.18 Item 7.2 of detailed BOQ, technical specifications, drawings and instructions of Engineer in charge\nSign Size -1500 x 300 | item49 | 1 | Nos |
51 | 1.5 | Print on Self Adhesive Frosted Film,\nFace mounted\nDwg No. 7.2a,b,c\nwith Sign Face all complete as per Sl.No.18 Item 7.2 of detailed BOQ, technical specifications, drawings and instructions of Engineer in charge\nSign Size -2400 x 300 | item50 | 1 | Nos |
52 | 1.51 | Print on Self Adhesive Frosted Film,\nFace mounted\nDwg No.7.3a,b,c\nwith Sign Face all complete as per Sl. No. 19 Item 7.3 of detailed BOQ, technical specifications, drawings and instructions of Engineer in charge\nFloor marking sign Size - 550 x 480 | item51 | 3 | Nos |
53 | 1.52 | Print on Self Adhesive Frosted Film,\nFace mounted\nDwg No.7.3a,b,c\nwith Sign Face all complete as per Sl. No. 19 Item 7.3 of detailed BOQ, technical specifications, drawings and instructions of Engineer in charge\nFloor marking sign Size -1000x375 | item52 | 3 | Nos |
54 | 1.53 | Print on Self Adhesive Frosted Film,\nFace mounted\nDwg No.7.3a,b,c\nwith Sign Face all complete as per Sl. No. 19 Item 7.3 of detailed BOQ, technical specifications, drawings and instructions of Engineer in charge\nFloor marking sign Size - 1600x600 | item53 | 1 | Nos |
55 | 1.54 | Supply and fixing of STATUTORY SIGNS ( Authorized persons only /hazard/Danger/Caution) Self Adhesive Vinyl with Black letters in yellow background ,Printed in Vinyl material with high glow finish of standard Size and other accessories complete as required as per the technical specification, drawings and instructions of Engineer in charge.\nStatuatory Signs Size - 250 x 200 | item54 | 10 | Nos |
56 | 1.55 | Supply and fixing of Self Adhesive Vinyl with Black (Marking/Printing) in yellow background, Printed in Vinyl material with high glow finish of standard Size and other accessories complete as required as per the technical specification drawings and instructions of Engineer in charge. | item55 | 8 | Nos |
57 | 2 | Other Items | |||
58 | 2.01 | 4 Way TPN MCB DB\nIncomer:63 A 4 Pole, 10kA, 'C' curve MCB - 1No.\nOutgoings:12 Nos 10A, SP MCBs as per DB SLD & Specification.(MCB-B curve for lighting ,C curve for power load) | item56 | 1 | Nos |
59 | 2.02 | 4 Way, SPN MCB DB\nIncomer:16A 2 Pole, 16kA, MCB - 01No.\nOutgoings:4 Nos 10A, SP MCBs as per DB SLD & Specification.(MCB "C" curve for power load) | item57 | 4 | Nos |
60 | 2.03 | Supply, laying and testing and commissioning of following sizes of XLPE /PVC Insulated, cores laid up, PVC tape/Extruded Inner sheathed,galvanised steel strip armoured, Extruded PVC Type ST2 Sheathed, Aluminium conductor 1.1 kv grade cable as per IS 7098(Part 1) 1988 on wall/ceiling/ cable tray / masonry duct/pipes with suitable MS Clamps wherever required as per specification.(Cost including Excavation & Refilling of UG cable work) ALL CABLES TO BE IDENTIFIED WITH METAL IMPRINT CABLE TAG ON BOTH ENDS complet as per detailed BOQ, technical specifications, drawings and instructions of Engineer in charge.\n4C x 4sqmm Cu Cable | item58 | 50 | Metre |
61 | 2.04 | Supply and installation of the pole box proposed within the stone pedestal of Totem sign at entrances shall have provision of one SPN M.C.B. of 6A (10 KA\nbreaking capacity ) for control / Isolation of incoming and outgoing cables / wires. The wiring within the sign from pole box shall be provided by the contractor which shall be of 2.5 sq.mm. FRLS, PVC insulated 1.1 KV grade, with multi-stranded copper conductor for phase and neutral and 1.5 sq.mm. with solid copper conductor wire\nfor earth. The incoming cable upto pole box shall not be in the scope of this tender, but its terminations shall be the responsibility. of the contractor. An earth terminal for connecting the earth wire shall be provided in the pole box.Pole box (junction box) shall be made out of polycarbonate/compressed moldedfiberglass polyester and designed to insulate and protect the controller and component in outdoor/indoor application making it water proof. It shall be Lockable with a universal lock/ quarter turn lock and UV stabilized for outdoor usage. This Junction box shall have a front openable hinged door provided with appropriate gasket And all metal components/fittings should be non corrosive made of brass to withstand moist condition all complete as per detailed BOQ, technical specification, drawings and instructions of Engineer in charge. | item59 | 10 | Nos |
62 | 2.05 | Supply and installation of the Junction Control Box proposed for Station name sign on exterior sign shall have provision of mounting 2 Nos. S.P. M.C.Bs. of\n6A (10 KA breaking capacity) for control / Isolation of incoming and outgoing cables / wires along with separate neutral link and earth link.\nThis junction box shall be of size 150x225x100 mm. Fabricated out of 16 S.W.G M.S. sheet duly painted of same shade and as per specifications specified for painting of structure . This shall have a front openable hinged door, provided with Neoprene gasket and double screwed knobs for closing. The complete junction control box shall be weatherproof and shall have Index of Protection of I.P. – 53. All complete as per detailed BOQ, technical specifications, drawings and instructions of Engineer in charge. | item60 | 10 | Nos |
63 | 2.06 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required in technical specifications, drawings and instructions of Engineer in charge.\n2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | item61 | 150 | Metre |
64 | 2.07 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required\n2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | item62 | 100 | Metre |
65 | 2.08 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required in technical specifications, drawings and instructions of Engineer in charge.\n2 X 4 sq. mm + 1 X 4 sq. mm earth wire | item63 | 100 | Metre |
66 | 2.09 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required in technical specifications, drawings and instructions of Engineer in charge.\n2 X 6 sq. mm + 1 X 6 sq. mm earth wire | item64 | 100 | Metre |
67 | 2.1 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required in technical specifications, drawings and instructions of Engineer in charge.\n20 mm | item65 | 100 | Metre |
68 | 2.11 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required in technical specifications, drawings and instructions of Engineer in charge.\n25 mm | item66 | 100 | Metre |
69 | 2.12 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required in technical specifications, drawings and instructions of Engineer in charge.\n32 mm | item67 | 100 | Metre |