Providing And Installing Of One Nos New Pvc Tubewell For New Water Supply Scheme Village Maure , Block Chogawan Including Rising Main 10Kgcm2 Sluice Valve And Sluice Valve Chamber Complete In All Respect, Amritsar-Punjab

Water Supply And Sanitation Department-WSSD has published Providing And Installing Of One Nos New Pvc Tubewell For New Water Supply Scheme Village Maure , Block Chogawan Including Rising Main 10Kgcm2 Sluice Valve And Sluice Valve Chamber Complete In All Respect. Submission Date for this Tender is 21-06-2021. Tube Well Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

28107399
Corrigendum : Providing And Installing Of One Nos New Pvc Tubewell For New Water Supply Scheme Village Maure , Block Chogawan Including Rising Main 10Kgcm2 Sluice Valve And Sluice Valve Chamber Complete In All Respect
Open Tender
Indian
Punjab
Amritsar
21-06-2021

Tender Details

Providing And Installing Of One Nos New Pvc Tubewell For New Water Supply Scheme Village Maure , Block Chogawan Including Rising Main 10Kgcm2 Sluice Valve And Sluice Valve Chamber Complete In All Respect

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Jun-2021 Corrigendum No. 3132 Dated 17-06-2021 Date 21-06-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 11600.0 /-
Tender Value
INR 5.80 Lakhs /-

BOQ Items

Name of Work:- Providing & Installing of One Nos New PVC Tubwell for New Water Supply Scheme, Rising Main 10kg/cm2, Sluice Valve, Sluice Valve Chamber Complete in all Respect at Village Maure Block Chogawan Distt Amritsar (Under 4215)"..
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Boring with casing pipe for tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as required such as hand boring machine and its accessory,transportation to site and vice versa etc. complete in all respect. 0 to 140 m iteam1 140 Mtr.
2 2 Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – in-charge.\n200 mm nominal size dia. iteam2 130 Mtr.
3 3 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.\n200 mm nominal size dia. (5mm thick slot size 0.20mm) iteam3 10 Mtr.
4 4 Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in\nall respect iteam4 1 No.
5 5 Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. iteam5 1 Each
6 6 Supplying & Fixing of PVC End Cap complete in all respect. iteam6 1 Each
7 7 Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect \n(C) 200 mm internal diameter iteam7 1 Each
8 8 Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) iteam8 3 No
9 9 Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.\nCapacity of Air compressor 300 cfm at 250 PSI iteam9 10 P.Hrs
10 10 Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. iteam10 4 P.Hrs
11 11 Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) iteam11 1 No
12 12 Provision for Sanitary Clay Seal (as per BIS Code IS 2800: 2019) including Sterlization of Tubewell iteam12 1 No
13 13 Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 223 LPM against a head of 54 mtr along with electric panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. including G.I. Column Pipe of suitable size 65 mm =31 mtr (in 3 mtr lengths each with flanges , screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable (reputed make) complete in all respects as per standard Specifications. iteam13
14 13.01 Cost of pumping set iteam14 1 No
15 13.02 Cost of lowering (with length)Column pipe 65mm dia iteam15 31 mtr
16 13.03 Cost of submersible Cable (with Length) 2.50mm size iteam16 35 mtr
17 13.04 Cost of Panel Board iteam17 1 Job
18 14 Supplying, Laying, Jointing, Cutting and Testing of 110 mm O/d PVC Pipes and Specials for 10 kg per cm2 including cost of excavation complete in all respects as per DWSS standard analysis. Rising Main to connect new tubewell with existing rising main. (Make Finolex, Supreme, Kissan Moulding or Equivalent (Mechnically). \n110mm o/d pipe of 10 Kg/cm2 iteam18 30 Mtr.
19 15 Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) 100 mm o/d iteam19 1 No
20 16 Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department. (1 no. each of size 0.6m x 0.6m) iteam20 1 No
21 17 Providing and installing 100 mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects as Annexure A12 – 1 & Drawings D-12 & D-17. iteam21 1 each
22 18 CONDITIONS :- iteam22
23 18.01 Item for which no rate or price has been entered in will not be paid for the Employer when execut6ed and shall be deemed covered by the other rates and prices in the Bill of Quantities. iteam23
24 18.02 Unit rates and prices shall be quated by the bidder in indian ruppees. iteam24
25 18.03 Where there is a discrepancy between the rate in figures and words, the rates in words will govern. iteam25
26 18.04 Where there is a discrepancy between the rate and the line total resulting from muluplying the unit rate by quantity the unit rate quoted shall govern. iteam26
27 18.05 Any item of work not included in the above contract schedule of rates and got done at the site of work; the same will be paid according to CSR-2010 subject to the premium or discount tendered by the contractor. In the case of non-schedule items, the decision of the Engineer-in-charge will be final and binding upon the contractor. In case any item which is a part of lump-sum rate is be deducted @CSR rates + Ceiling premium prevailing on the date of tender iteam27
28 18.06 The work will be carried out in accordance with PWD Book of specifications - 1963 edition with upto date amendments. iteam28
29 18.07 Approximate quantities are given in the contract schedule of rates and these can vary at the time of execution of the work. The payment will be made according to the actual work done by the contractor. iteam29
30 18.08 All amendments issued on the common schedule of rates 2010. up to the date of opening of tenders will be applicable on the contract schedule of rates. iteam30
31 18.09 Contractor should clearly quote his rates in figures & words. Conditional tender will be rejected. iteam31
32 18.1 All items and rates provided in the DNIT are subject to the footnotes give in CSR-2010 iteam32
33 18.11 The Engineer-in-charge will have full powers to change the layout of the work covered in this contract if considered necessary. iteam33
34 18.12 No claim will be entertained form the contractor in case, any mistake in description rates or unit occurs in any item taken in this schedule while preparing this DNIT or on account of typing or comparison or over writing. The same will be rectified at any time as per common schedule of rates 2010 along with upto date amendments. iteam34
35 18.13 The arrangements of bricks at site of work would be done by the contractor at his own level from his own source. iteam35
36 18.14 For any other non-schedule items, the contractor will submit through Engineer-in-charge, the analysis of rates in triplicate based on purchased vouchers. A margin of 10% shall be allowed for material components and 21.5% on labour components and contractor shall produce photo stat copies of the purchase vouchers in support of his claim. The decision of the Engineer-in-charge/Competent authority in the matter shall be final and binding on the contractor. iteam36
37 18.15 All the extra items will be got approved from the competent authority and no premium will be allowed on non schedule item iteam37
38 18.16 Pavement for the carriage of material shall be paid as per the rates quoted by the tenderer. iteam38
39 18.17 Time period allowed for completion of work in 2 months. iteam39
40 18.18 If contractor allowed for completion of work within 7 days from the date of allotment, DWSS reserve the right to impose penalty or withdraw the work and propose action for debarring in future tendering or both; decision of Chief Engineer (North) shall be binding. iteam40