| 1 | 1 | Based on Electric BSR 2013 | | 0.0001 | Each |
|---|
| 2 | 2 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, round tiles,Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch,Modular plate with grid plate, screws, making connections, testing etc. as required.Gp-AI | | 0.0001 | Each |
|---|
| 3 | 3 | Short point (up to 3 mtr.) | | 33 | P. point |
|---|
| 4 | 4 | Medium point (up to 6 mtr.) | | 82 | P. point |
|---|
| 5 | 5 | Long point (up to 10 mtr..) | | 98 | P. point |
|---|
| 6 | 6 | Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal, 6 A modular switch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required.Gp-AI | | 0.0001 | Each |
|---|
| 7 | 7 | On board | | 104 | P. point |
|---|
| 8 | 8 | Long point (up to 10 mtr..) | | 28 | P. point |
|---|
| 9 | 9 | S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required.Gp-I | | 0.0001 | Each |
|---|
| 10 | 10 | 20 mm | | 400 | R. mtr. |
|---|
| 11 | 11 | 25 mm | | 2500 | R. mtr. |
|---|
| 12 | 12 | 32 mm | | 175 | R. mtr. |
|---|
| 13 | 13 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.Gp-AI | | 0.0001 | Each |
|---|
| 14 | 14 | 2 x 2.5 sq. mm. + 1x1.5sqmm | | 2250 | Mtr. |
|---|
| 15 | 15 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. | | 2000 | Mtr. |
|---|
| 16 | 16 | 4 x 6.0 sq.mm | | 200 | Mtr. |
|---|
| 17 | 17 | 1 x 4.0 sq.mm | | 200 | Mtr. |
|---|
| 18 | 18 | 4 x 10.0 sq.mm | | 200 | Mtr. |
|---|
| 19 | 19 | 1 x 6.0 sq.mm | | 200 | Mtr. |
|---|
| 20 | 20 | Supplying and fixing of power plug point Modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost of modular 16 amp. Switch and socket outlet , making connection , testing , etc. as required.Gp-I | | 44 | Each |
|---|
| 21 | 21 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.Gp-AI | | 0.0001 | Each |
|---|
| 22 | 22 | Single pole MCB | | 0.0001 | Each |
|---|
| 23 | 23 | 6 A to 32 A rating | | 108 | Each |
|---|
| 24 | 24 | Triple pole MCB | | 0.0001 | Each |
|---|
| 25 | 25 | 6 A to 32 A rating | | 6 | Each |
|---|
| 26 | 26 | Four pole MCB | | 0.0001 | Each |
|---|
| 27 | 27 | 6 A to 32 A rating | | 3 | Each |
|---|
| 28 | 28 | 40 A 63 A rating | | 3 | Each |
|---|
| 29 | 29 | P&F 240/415 V Residual current circuit breaker conforming to IS:12640:1988/ IEC 61008 on existing board/sheet including making connections, testing etc. as required.Gp-AI | | 0.0001 | Each |
|---|
| 30 | 30 | Two pole 100/300mA sensitivity | | 0.0001 | Each |
|---|
| 31 | 31 | 25 A rating | | 8 | Each |
|---|
| 32 | 32 | 40 A rating | | 6 | Each |
|---|
| 33 | 33 | P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required.Gp-AI | | 0.0001 | Each |
|---|
| 34 | 34 | Double door (Three phase) Per phase isolation | | 0.0001 | Each |
|---|
| 35 | 35 | 2+8 Way | | 4 | Each |
|---|
| 36 | 36 | Double door (single phase) | | 0.0001 | Each |
|---|
| 37 | 37 | 8 Way | | 2 | Each |
|---|
| 38 | 38 | P&F recessed/ surface mounting heavy duty Vertical type 16 SWG sheet steel Distribution board with provision of incomer suitable for MCCB and SP / TP MCB as outgoing , phophatised ,powder painted complete with insulated suitable rating copper bus bar , neutral link, earth link and din bar, masking sheet & conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. | | 0.0001 | Each |
|---|
| 39 | 39 | Double door with Provision of Incomer MCCB 100 / 125 A Rating | | 0.0001 | Each |
|---|
| 40 | 40 | 6 Way | | 1 | Each |
|---|
| 41 | 41 | SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs & spreaders, etc. as required. | | 0.0001 | Each |
|---|
| 42 | 42 | With Thermal Magnetic release | | 0.0001 | Each |
|---|
| 43 | 43 | 160 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu | | 1 | Each |
|---|
| 44 | 44 | P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required.Gp-I | | 0.0001 | Each |
|---|
| 45 | 45 | 5 step fan regulator 2 Module | | 50 | Each |
|---|
| 46 | 46 | 6 A one way switch | | 25 | Each |
|---|
| 47 | 47 | 6 A 3 pin shuttered socket | | 25 | Each |
|---|
| 48 | 48 | RJ-11 telephone jack single two line | | 27 | Each |
|---|
| 49 | 49 | 32 Amp. 2 Module switch With Indicator | | 17 | Each |
|---|
| 50 | 50 | 25 Amp. 2 Module Socket | | 17 | Each |
|---|
| 51 | 51 | Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured/ armoured telephone cable with 0.5 mm dia. Tinned / annealed copper conductor taped &confirming to ITD specification S/WS -113C of approved make in existing surface or recessed conduit/casing capping.Gp-I | | 0.0001 | Each |
|---|
| 52 | 52 | Unarmoured Telephone cable in existing surface or recessed conduit/casing capping. | | 0.0001 | Each |
|---|
| 53 | 53 | 5 pair | | 375 | Mtr. |
|---|
| 54 | 54 | 10 pair | | 125 | Mtr. |
|---|
| 55 | 55 | Jelly filled armoured (PIJF) Armoured telephone cable including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. | | 0.0001 | Each |
|---|
| 56 | 56 | 50 pair | | 50 | Mtr. |
|---|
| 57 | 57 | P & F Krone module with base frame in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted.,including dressing, ferruling and punching of telephone cable with krone tool etc. as required. | | 0.0001 | Each |
|---|
| 58 | 58 | 10 Pairs | | 1 | Each |
|---|
| 59 | 59 | 50 Pairs | | 1 | Each |
|---|
| 60 | 60 | P & F following size mounting grid plates with cover plates.Gp-I | | 0.0001 | Each |
|---|
| 61 | 61 | 1/2 Module | | 50 | Each |
|---|
| 62 | 62 | 8 Module | | 27 | Each |
|---|
| 63 | 63 | P & F following size hot dip galvanized M.S. box of 20 SWG with earthing terminal in recess/ surface suitable for modular accessories as required. | | 0.0001 | Each |
|---|
| 64 | 64 | 1-2 Module | | 50 | Each |
|---|
| 65 | 65 | 8 Module | | 27 | Each |
|---|
| 66 | 66 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. | | 2 | Set |
|---|
| 67 | 67 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. | | 0.0001 | Each |
|---|
| 68 | 68 | 8 SWG G.I. ( Hot Dipped ) Wire | | 50 | Mtr. |
|---|
| 69 | 69 | P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . | | 50 | Each |
|---|
| 70 | 70 | P & F of ventilating fans, Capacitor start, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required.Gp-I | | 0.0001 | Each |
|---|
| 71 | 71 | 250 mm sweep | | 2 | Each |
|---|
| 72 | 72 | P&F of Heavy duty capacitor start, Double ball bearing 900/1400 RPM single phase ISI marked Exhaust fan,IS:2312 marked in existing opening including making connections testing etc. as required.Gp-I | | 0.0001 | Each |
|---|
| 73 | 73 | 300 mm sweep(900/1400 RPM) | | 8 | Each |
|---|
| 74 | 74 | P & F extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as reqd. | | 25 | Mtr. |
|---|
| 75 | 75 | P & F of IP20 surface/recess mounted LED downlight made of pressure diecast aluminium housing, with heat sink and good quality reflector, high efficiency external driver, power consumption 14/15 watt, system lumen efficiency >80 lumen/watt, CCT 6000K (minimum) K, CRI>80, PF>0.9 life time 50,000 burning hours. | | 84 | Each |
|---|
| 76 | 76 | P&F of 36 Watt IP 20 LED 2'x2' fixture, Recessed / surface type, having efficacy of not less than 100 lumen / watt, made out from CRCA housing and with high purity / transmisvity duffuser for uniform light distribution high efficiency driver electronics and in compliance to IEC standard (integral with light fisture), life time of more than 50000 burning hours, CCT 6000K (minimum), CRI>80 driver maintaining PF>0.9. | | 8 | Each |
|---|
| 77 | 77 | Making hole in stone masonary/ RCC with core cutter for accomodating refrigerant pipe/ drain pipe for split/ cassattee/ ductable AC | | 0.0001 | Each |
|---|
| 78 | 78 | 50mm to 150mm | | 5 | Each |
|---|
| 79 | 79 | Supply & Fixing ISI marked ( IS : 15683 ) Portable Fire Exitnguisher, ABC type,finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of following capacity. | | 0.0001 | Each |
|---|
| 80 | 80 | 4 kg | | 4 | Each |
|---|
| 81 | 81 | Supply & Fixing ISI marked ( IS : 15683 ) Portable fire Extinguisher, Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia. min. 600 mm long & complete in all respects including initial fill with C02 gas confirming to IS:307-1966 filled to a filling ratio of not more than 0.667and wall suspension bracket. Capacity 4.5 Kg. | | 4 | Each |
|---|
| 82 | 82 | S & Laying following size' B ' class G.I. Pipe confirming to IS : 1239 P - 1 ( 1990 ) with accessories for laying earth conductor/strip / cable in ground/surface/recess as required | | 0.0001 | Each |
|---|
| 83 | 83 | 100 mm dia. | | 25 | Mtr. |
|---|
| 84 | 84 | Supply , Installation, Testing and Comissioning of Wall mounted Communication rack with glass doors, handles ,lock , Top and Bottom Cable entries, Supports for mounting rack on wall , Cable managers, one Fan, Equipment mounting hardware, power supply box for supplying power to switches, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable Gp-I | | 0.0001 | Each |
|---|
| 85 | 85 | 9 U(44 mm ) wall mounted | | 1 | Each |
|---|
| 86 | 86 | 12 U(44 mm ) wall mounted | | 2 | Each |
|---|
| 87 | 87 | Supply , Installation, Testing and Comissioning of Rack mounted 19\", Cat 6 UTP,1.5-1.6 MM CRS chasis , powder coated Modular Patch Panels with collapsible shutters on jacks to support latest ammendments of TIA / EIA Cat 6 Specifications in Existing Communication Rack along with necessary connections of Cat 6 UTP Cables, With Rear Cable management trays and clamps.Gp-I | | 0.0001 | Each |
|---|
| 88 | 88 | 12 Ports | | 1 | Each |
|---|
| 89 | 89 | 24 Ports | | 2 | Each |
|---|
| 90 | 90 | Supply , Drawing and Testing of 4 pair, 24 AWG UTP Cat 6 Cable as per latest ammendments of TIA /EIA 568 B.2-1 Specifications in existing MS/PVC Conduits including making connections to Information outlets and Patch Panels with ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing required Gp-I | | 1750 | Mtr. |
|---|
| 91 | 91 | Supply and Installation of Information outlets made of high impact plastic body ABS FR Grade with spring loaded collapsible shutters in jack Recess, suitable for Cat 6 application complying to latest ammendments EIA/ TIA 568 B.2-1 Specifications in existing modular /MS Boxes along with necessory connections as required.Gp-I | | 35 | Each |
|---|
| 92 | 92 | Supply & fixing of Faceplate for Flush / Surface Mount Information Outlets Single Aperture with screw hole covers & Icon Tree Size 86mmX86mm Gp-I | | 0.0001 | Each |
|---|
| 93 | 93 | Single Aperture | | 35 | Each |
|---|
| 94 | 94 | Supply , Installation and Testing of 4 pair , 100 Ohm, 24 AWG , Cat 6 UTP, flexible , Double ended Patch Cords along with 2 No of RJ 45 connectors with strain relief transparent boots as per TIA /EIA 568 B.2-1 Specifications.Gp-I | | 0.0001 | Each |
|---|
| 95 | 95 | 1 Mtr/3 ft | | 35 | Each |
|---|
| 96 | 96 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. | | 0.0001 | Each |
|---|
| 97 | 97 | 70.0 Sq,mm | | 0.0001 | Each |
|---|
| 98 | 98 | 3.5 core | | 210 | Mtr. |
|---|
| 99 | 99 | 6.0 Sq.mm | | 0.0001 | Each |
|---|
| 100 | 100 | 4 core | | 200 | Mtr. |
|---|
| 101 | 101 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. | | 0.0001 | Each |
|---|
| 102 | 102 | 3.5 x 70.0 sq.mm | | 2 | Set |
|---|
| 103 | 103 | SITC of Interconnecting refrigerant copper pipe work between each set of indoor & outdoor units of different sizes as per required specifications including chase cutting, supports etc. as required. | | 33 | Kg |
|---|
| 104 | 104 | Supply & fixing of external thermal closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specificationsnitrile including cost of adhesive complete as per specification and as required. | | 0.0001 | Each |
|---|
| 105 | 105 | 9mm thick insulation | | 0.0001 | Each |
|---|
| 106 | 106 | 9mm thick insulation and 10 mm internal Dia | | 43 | Mtr. |
|---|
| 107 | 107 | 9mm thick insulation and 16 mm internal Dia | | 43 | Mtr. |
|---|
| 108 | 108 | S & F of FR PVC insulated & sheathed 3 core flexible copper conductor ISI marked (IS:694) of 1.1 kV grade of following rating: | | 0.0001 | Each |
|---|
| 109 | 109 | 2.5 Sq.mm | | 43 | Mtr. |
|---|
| 110 | 110 | S & F of rigid CPVC (25mm) drain piping of 6 kg/ cm2 with 6mm thick nitrile rubber insulation. | | 43 | Mtr. |
|---|
| 111 | 111 | Providing and making wall openings in existing Bricks masonary wall complete with all requited T & P ,Scafolding and providing lintel of required size and strength, repairing ,plastering and cleaning the site debrises as required. | | 55 | Cuf |
|---|
| 112 | 112 | SITC of Air Cooled split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 4 Mtr (IDU to ODU), R-22/R-410 Refrigerant, Remote, suitable for 400/230V +10% of 50 Hz ,1 /3 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / reciprocating / rotary compressor as specified. | | 0.0001 | Each |
|---|
| 113 | 113 | Hi Wall/Ceiling Wall Split | | 0.0001 | Each |
|---|
| 114 | 114 | 2.0 TR with 3 star rating of BEE | | 17 | Each |
|---|
| 115 | 115 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. | | 17 | Each |
|---|
| 116 | 116 | P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required of Gemini or IS:14930 marked make. Outer Dia. / Inner dia. | | 0.0001 | Each |
|---|
| 117 | 117 | 110 / 95 mm | | 200 | Mtr. |
|---|
| 118 | 118 | P & F of IP 65 protected LED Street Light fixture 70-75 watt (with surge protection device 10KA) applicable for area lighting with extruded pressure diecast aluminium housing, system lumens efficancy of 100 Im/watt minimum, toughened glass with diffuser, suitable lenses on LED, 240V, 50 Hz of High Power LED lamps supplied with pre-wired cable of 1 mtr. Integrated Driver shall be high efficiency having efficiency>85% and in compliance to IEC standards system life of 50,000 Burning Hours, CRI>80, PF>0.90 at full load, CCT 5700-6500 K (as per direction of Engineer incharge). Fixtures shall be CE compliance. | | 8 | Each |
|---|
| 119 | 119 | S & F of Street light bracket made out from following size of ' B ' class GI pipe with heavy duty pole clamp, Saddles suitable fastners etc. as required. | | 0.0001 | Each |
|---|
| 120 | 120 | 32 mm Dia. | | 8 | Mtr. |
|---|
| 121 | 121 | Providing and fixing of IP 65 protectd Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, complete with The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect. | | 0.0001 | Each |
|---|
| 122 | 122 | 125 mm X 200 mm X 122 mm | | 8 | Each |
|---|
| 123 | 123 | Supplying and making end termination with heavy Copper lugs ( Pin / ring type ) duly crimped with crimping tool, PVC tape etc of following size. | | 0.0001 | Each |
|---|
| 124 | 124 | 1.5 Sq.mm | | 24 | Each |
|---|
| 125 | 125 | 2.5 Sq.mm | | 64 | Each |
|---|
| 126 | 126 | 4.0 Sq.mm | | 37 | Each |
|---|
| 127 | 127 | 6.0 Sq.mm | | 20 | Each |
|---|
| 128 | 128 | 10.0 Sq.mm | | 16 | Each |
|---|
| 129 | 129 | SITC of self contained drinking water coolar with energy efficient hermetic sealed type compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz ac supply,Full stainless steel (S304)body and tank , stainless steel water tray,minimum two nos faucets and suitable drainage system complete in all respect with 300mm height MS fabricated and painted plateform. complete in all respect of the following capacity | | 0.0001 | Each |
|---|
| 130 | 130 | cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs | | 2 | Each |
|---|
| 131 | 131 | NON BSR | | 0.0001 | Each |
|---|
| 132 | 132 | P & F of IP20 Box type LED tube light fixture made from extruded aluminium housing suitable for moutning LED tube system non replaceable driver, with a minimum system lumen output of 2400 lumens and a minimum system efficiency of 110 lm/W. Power Consumption of 22W , life time of 25,000 burning hours with 70% initial lumen maintained. CCT 4000°K & 6500°K. Contractor should submit LM79 & LM 80 Report of fixture & LED Lamp for conforming above specification at the time of approval of fixture. (Make PHILIPS, Havells, Crompton , Wipro , Bajaj, Polycab, Jaquar) | | 33 | Each |
|---|
| 133 | 133 | P & F of 1200 mm sweep double ball bearing capacitor start, aluminium body & blade ceiling fan with down rod from 30 cm to 100 cm as required rated speed 390(+/- 10% ) RPM, Air delivery at 230 V should be 230 m³/min, Temp. rise 75 Degree Centigrade Maximum, Insulation Resistance 2 mega ohm Minimum, wiring with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. of Havell's SS390 or Equivalent in Usha / Orient / Crompton Make. | | 50 | Each |
|---|
| 134 | 134 | Supplying, installation, testing & commissioning of 9-10 watt 3000K mirror light all accessories i/c connections with 3 x 1.5 sq.mm PVC insulated FR copper conductor cable etc. as reqd. (Make:- Wipro/ Philips/ bajaj/havells) | | 6 | Each |
|---|
| 135 | 135 | P & F of wall Cowl made out from 24 SWG GI sheet & GI welded wire mesh of 10/12 swg for Bird Screen Suitable for Outside Wall of Exhaust Fan Opening of following size and as per instructions of Engineer in charge including fixing with suitable fasteners etc. as required. | | 0.0001 | Each |
|---|
| 136 | 136 | Suitable for 300 mm sweep Exhaust Fan | | 8 | Each |
|---|
| 137 | 137 | P & F of Surface mounting LED bulk head fitting, efficacy >=110 lumens /watt total Lumen output not less than 1000, CRI>80 and CCT=4000/6500 K(as reqd.), with inbuilt LED Driver and IP-65 & IK08 and better rated with pressure die cast aluminum housing & diffused polycarbonate diffuser complete as required.Make PHILIPS, Havells, Crompton , Wipro , Bajaj, Polycab, Jaquar | | 4 | Each |
|---|
| 138 | 138 | P & F Double ball bearing and with sturdy mesh guard metal body ,3 numbers metal blales oscillating tye wall mounting Fan, including fixing with anchor bolts, adjustable upward and downward tilt mechanism, noise level should <=75 db, power consumption <=120 watts, motor protection through thermal overload protection device, 3 speed regulator making connection testing etc. as required. Make:- Havell 450mm V3 or equivalent make | | 0.0001 | Each |
|---|
| 139 | 139 | 450 mm sweep With three speed regulator | | 5 | Each |
|---|