Construction Of Lah Processing Unit Bundu Ranchi Jharkhand
Tender Value
1.31 Crore
Estimated cost
Bid Submission
11 Jun 2021
0 days left
EMD
2.63 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
bundu → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Lah Processing Unit Bundu Ranchi Jharkhand
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-Jun-2021 | change in terms and conditions in tender documents | Technical Bid | 11-Jun-2021 |
BOQ
| Name of Work: CONSTRUCTION OF LAH PROCCESSING UNIT AT BUNDU, RANCHI, Jharkhand. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I. | Item no.1 | 325.11 | Cum |
| 2 | 2 | Extra for earth work hard soil (vide classification of soil item-B) as per approved design building specification and direction of EI. | Item no.2 | 325.11 | Cum |
| 3 | 3 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). | Item no.3 | 511.5 | Cum |
| 4 | 4 | Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume). | Item no.4 | 245.33 | Cum |
| 5 | 5 | Providing designation 75B one BRICK FLAT SOILING joint filled with local sand including cost of watering taxes royalty all complete as per | Item no.5 | 1847.68 | Sqm |
| 6 | 6 | Providing designation 75B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening maerials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. | Item no.6 | 43.985 | Cum |
| 7 | 7 | Providing designation 75B brick work with \n in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. | Item no.7 | 168.12 | Cum |
| 8 | 8 | Providing P.C.C. M-150 with nominal mix of (1:2:4) in foundation with approved quality of stone metal grade - III (50 mm to 25mm size) clean coarse sand of F.M 2.5 to 3 including screening, shuttering,mixing cement concrete in mixer and placing in position vibrating, skirting, curing, taxes and royalty all complete all complete as per building specification and direction of Engineer-incharge. | Item no.8 | 190.99 | Cum |
| 9 | 9 | Providing R.C.C. M-200 with normal mix of (1:1.5:3) in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I | Item no.9 | 99.2 | Cum |
| 10 | 10 | Providing R.C.C. M-200 in band at plinth level with nominal mix of (1:1.5:3) of approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. | Item no.10 | 17.76 | Cum |
| 11 | 11 | Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in lintel with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. | Item no.11 | 10.68 | Cum |
| 12 | 12 | Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in roof slab with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. | Item no.12 | 9.375 | Cum |
| 13 | 13 | Providing R.C.C. M-200 with nominal mix of (1:1½:3) in Roof beam of all types with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. | Item no.13 | 17.805 | Cum |
| 14 | 14 | Providing R.C.C. M-200 with nominal mix of (1:1½:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. | Item no.14 | 21.05 | Cum |
| 15 | 15 | Providing av. 63mm thick R.C.C. M-200\n with nominal mix of (1:1.5:3) Chajja with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including making drip course in concrete, screening, centering, shuttering and mixing cement concrete in mixer and placing in position, vibrating, striking 6mm cement plaster (1:4) in ceiling and sides of chajja with sand of F.M. 1.5 curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I. | Item no.15 | 23.085 | Sqm |
| 16 | 16 | Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in staircase with approved quality of stone chips 20mm to 10mm size graded and clean coarse sand of F.M. 2.5 to 3 including centering, screening, shuttering mixing cement concrete in mixer and placing in position, vibrating, striking, curing taxes and royalty all complete as per building specification and direction of E/I | Item no.16 | 1.55 | Cum |
| 17 | 17 | Providing Toe steel reinforcement of 8mm dia\n to 10mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STeel) | Item no.17 | 18.78 | MT |
| 18 | 18 | Providing and fixing fan hook of 16mm dia M.S bar 1 mtr long bent to required size and shape placed in position and fixed in RCC slab/beam at the time of casting all complete as per building specification and direction of E/I. (Where materials is not supplied by the deptt.) | Item no.18 | 4 | Nos. |
| 19 | 19 | Steel work welded in built up M.S Grill sections/ framed work (USE SQUARE BARS), including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.\nIn stringers, treads, landings etc. of stair cases, including use ofchequered plate wherever required, all complete | Item no.19 | 1008.18 | kg. |
| 20 | 20 | Supplying, fitting and fixing collapsible gate\n of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. | Item no.20 | 36.75 | Sqm |
| 21 | 21 | Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed\nby Engineer-in-charge 'Fixing with adjustable lugs with split end tail to\neach jamb | Item no.21 | 21.15 | MTR |
| 22 | 22 | Providing Primer One coats of red lead paints \n of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. | Item no.22 | 22.82 | Sqm |
| 23 | 23 | Providing two coats of synthetic enamel \npaint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. | Item no.23 | 113.91 | Sqm |
| 24 | 24 | Supplying, fitting & fixing 35mm, thick solid\n core type decorative double leaf flush door shutters with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with aluminum fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I. | Item no.24 | 8.6 | Sqm |
| 25 | 25 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at\njunctions, i.e. at top, bottom and sides with required EPDM rubber/\nneoprene gasket etc. Aluminium sections shall be smooth, rust free,\nstraight, mitred and jointed mechanically wherever required including\ncleat angle, Aluminium snap beading for glazing / paneling, C.P.\nbrass / stainless steel screws, all complete as per architectural\ndrawings and the directions of Engineer-in-charge. (Glazing, paneling\nand dash fasteners to be paid for separately) \nPowder coated aluminium (minimum\nthickness of powder coating 50 micron) | Item no.25 | 27.92 | KG |
| 26 | 26 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .\n(Cost of aluminium snap beading shall be paid in basic item): | Item no.26 | 45.68 | Sqm |
| 27 | 27 | Galvanised wire mesh of average width of aperture 1.4 mm and nominal\ndia of wire 0.63 mm | Item no.27 | 22.84 | Sqm |
| 28 | 28 | Providing 6mm thick cement plaster\n (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. | Item no.28 | 75 | Sqm |
| 29 | 29 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. | Item no.29 | 1007.07 | Sqm |
| 30 | 30 | Providing two coats of snowcem of approved shade and make over a coat of cement primer over new surface including prepairing the plastered surface by rubbing smooth with sand paper scaffolding curing,taxes all complete as per building specification and direction of E.I | Item no.30 | 1082.07 | Sqm |
| 31 | 31 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey,\nFume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including\npointing the joints with white cement and matching pigment etc., complete. | Item no.31 | 25.56 | Sqm |
| 32 | 32 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,\nincluding pointing in white cement mixed with pigment of matching shade\ncomplete | Item no.32 | 18.585 | Sqm |
| 33 | 33 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%\nand conforming to IS: 15622, of approved make, in all colours and shades laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the\njoints with white cement and matching pigments etc., complete | Item no.33 | 81.875 | Sqm |
| 34 | 34 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. | Item no.34 | 18.36 | Sqm |
| 35 | 35 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete | Item no.35 | 28634.8 | KG |
| 36 | 36 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.\n | Item no.36 | 2913 | Sqm |
| 37 | 37 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :\nRidges plain (500 - 600mm) | Item no.37 | 66 | MTR |
| 38 | 38 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Flashing / Aprons\nGutter (600 mm over all girth) | Item no.38 | 132 | MTR |
| 39 | 39 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes\n110 mm Rain water pipe | Item no.39 | 64.8 | MTR |
| 40 | 40 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.\nCoupler - 110mm | Item no.40 | 24 | Each |
| 41 | 41 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend - 110mm | Item no.41 | 16 | Each |
| 42 | 42 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Shoe - 110 | Item no.42 | 32 | Each |
| 43 | 43 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete\n110 mm | Item no.43 | 32 | Each |
| 44 | 44 | Carriage of materials\nBricks Lead = 7.+1 km | Item no.44 | 77.46 | Thou. |
| 45 | 45 | Sand lead = 10 km | Item no.45 | 317.17 | cum |
| 46 | 46 | Stone chips lead = 10 km | Item no.46 | 154.11 | cum |
| 47 | 47 | Stone metal lead = 10km | Item no.47 | 183.35 | Cum |
| 48 | 48 | Local Sand lead = 10km | Item no.48 | 6.225 | cum |
| 49 | 49 | septic tank with soakpit\nEarthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees shurbs all complete as per approved design building specification and direction of E/I.\nAll kinds of soil | Item no.49 | 31.44 | Cum |
| 50 | 50 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) | Item no.50 | 31.44 | Cum |
| 51 | 51 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) | Item no.51 | 2.25 | Cum |
| 52 | 52 | Providing designation 75Bwork in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I. | Item no.52 | 7.4 | Cum |
| 53 | 53 | Providing P.C.C. M-100 in nominal mix of (1:3:6) in foundation with approved quality of stone chips 20mm to 6mm size graded and mixing cement sand of F.M 2.5 to 3 including screening, shuttering, vibrating, skirting, curing, taxes and royalty all complete all complete as per specification and direction of Engineer-incharge. | Item no.53 | 2.25 | Cum |
| 54 | 54 | Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in lintel with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. | Item no.54 | 0.11 | Cum |
| 55 | 55 | Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in roof slab with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. | Item no.55 | 2.06 | Cum |
| 56 | 56 | Providing TMT steel reinforcement 8mm, 10mm, 12mm,16mm to 36mm dia bars as per approved design and drawing excluding carriage of M.S. roads (Straight or in coils) to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I. | Item no.56 | 0.17 | MT |
| 57 | 57 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I | Item no.57 | 14.97 | Sqm |
| 58 | 58 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. | Item no.58 | 58 | Sqm |
| 59 | 59 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. | Item no.59 | 58 | Sqm |
| 60 | 60 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey\ncomb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long\ncomplete as per standard design.\nWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | Item no.60 | 1 | Each |
| 61 | 61 | Bricks Lead = 8 km | Item no.61 | 34.88 | Thou. |
| 62 | 62 | Sand lead = 10 km | Item no.62 | 5.51 | Cum |
| 63 | 63 | Stone chips lead =10 km | Item no.63 | 3.89 | Cum |
| 64 | 64 | Local Sand lead = 3km | Item no.64 | 2.25 | Cum |
| 65 | 65 | SANITARY\nSupplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'P' trap 15 liters C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware ware footrest to be fixed than 50 gms, 15mm PVC connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. \nWith 12.5 lit. low level PVC cistern | Item no.65 | 1 | Each |
| 66 | 66 | Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I.\n(ii) E.W.C. with 'P' trap\n(b) 12.5 lit. low level PVC Cistem | Item no.66 | 1 | Each |
| 67 | 67 | Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of Hindustan 'Parry' or any other approved I.S.S. make with 5 litres capacity C.i. automatic flusing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specification and direction of E/I.\nFlat back or standard corner (600mm x 350mm) | Item no.67 | 1 | Each |
| 68 | 68 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. | Item no.68 | 1 | Each |
| 69 | 69 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete,\nincluding painting of fittings and brackets, cutting and making good the wall wherever required\nSize 600x450x200 mm | Item no.69 | 1 | Each |
| 70 | 70 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall \n25 mm nominal outer dia .Pipes. | Item no.70 | 30 | RMT |
| 71 | 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall \n32 mm nominal outer dia. Pipes. | Item no.71 | 20 | RMT |
| 72 | 72 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall\n40 mm nominal outer dia. Pipes. | Item no.72 | 15 | RMT |
| 73 | 73 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. \n15 mm nominal outer dia .Pipes. | Item no.73 | 15 | RMT |
| 74 | 74 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc.\n 20 mm nominal outer dia .Pipes. | Item no.74 | 20 | RMT |
| 75 | 75 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc.\n25 mm nominal outer dia .Pipes. | Item no.75 | 30 | RMT |
| 76 | 76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc.\n32 mm nominal outer dia .Pipes. | Item no.76 | 40 | RMT |
| 77 | 77 | Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I.\n(d) 32mm dia and weight not less than 700gms. | Item no.77 | 1 | Each |
| 78 | 78 | Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I.\n(e) 40mm dia and weight not less than 1.0 Kg.. | Item no.78 | 1 | Each |
| 79 | 79 | Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I.\n(f) 50mm dia and weight not less than 1.5 Kg. | Item no.79 | 1 | Each |
| 80 | 80 | Providing and fixing Male ended 15mm dia brass bib cock of approved quality (Wt. Not less than 350 gms) with extra socket all complete as per specification and direction of E/I. : | Item no.80 | 2 | Each |
| 81 | 81 | Providing and fixing brass/C.I stop cock of approved quality all complete as per specification and direction of E/I.\n15mm nominal bore | Item no.81 | 2 | Each |
| 82 | 82 | Providing and fixing 15mm size C.P. brass pillar cock (Weight not less than 350gms). C.I. body brass spindle pillar cock of approved quality as per specification and direction of Engineer-in-Charge.\n(b) C.I. body brass spindle | Item no.82 | 1 | Each |
| 83 | 83 | Providing and fixing PTMT grating of approved quality and colour.Circular type\n100 mm nominal dia | Item no.83 | 2 | Each |
| 84 | 84 | Providing and fixing PTMT grating of approved quality and colour.Circular type\n125 mm nominal dia with 25 mm waste hole | Item no.84 | 20 | Each |
| 85 | 85 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. \n110 mm diameter | Item no.85 | 20 | RMT |
| 86 | 86 | WATER TANK 25000 LITRES CAPACITY\nDesigning (aesthetivally), and constructiong RCC elevated service reservoirs of following capacity with RCC. Staging consisting of columns, intrnal and external bracings spaced vertically not more than 4.5 meters centre to centre for ESR having capacity upto 500 cum and not more than 6m c/c for ESR having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and out side face of the container and also plaster with plastic paint in all columns and bracings including refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying erecting, hoisting and jointing of pipe assembly of inlet, outler, washout overflow and bypass arrangement as per departmentals design, providing and fixing accessories such as M.S ladder out side, stainless steel lader in contnor, F.I. manhole frame and covers, water level indicators, lightening conductor, G.I. pipe railing around walk way and top slab, providing stair case from ground level to roof level, M.S grill gate of 2m height with locking arrangement of approved design, BB masonry chambers for all valves ventilating shfts providig and applying three coats of acryline emulsion with silicon edditives paint to the structure incluing roof slab, epoxy painting o internal surface and antitermite treatment for under ground part soft he structure and giving satisfactory water tightness test as pe I.S code. The job to include painting then ame of the scheme and other details on the reservior as per the direction of engineer in, charge. | Item no.86 | 1 | Each |
| 87 | 87 | ELECTRICAL Point wiring in PVC conduit, with modular type switch - \nPoint wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required.\nGroup - B | Item no.87 | 90 | P/Point |
| 88 | 88 | Wiring for twin control light point with 1.5 sq.mm \nFRPVC insulated copper conductor single/core cable in surface/recessed PVC conduit 2 way piano type switch phenolic laminated sheet cover suitable size M.S. box and earthing the paint with 1.5 sq.mm FRPVC | Item no.88 | 4 | Each |
| 89 | 89 | Wiring for light/power plug with 2 x 4 sq.mm FRPVC insulated\n copper conductor single core cable in surface/recessed PVC conduit along with 1 No. sq.mm FRPVC insulated copper conductor single core cable for loop earthing as required | Item no.89 | 120 | Mtr. |
| 90 | 90 | Wiring for Curcuit submain wiring along with earth\n wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC sonduit as required\n2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire | Item no.90 | 205 | \nMtr. |
| 91 | 91 | Wiring for Curcuit submain wiring along with earth\n wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC sonduit as required\n2 x 4.0 sq.mm. + 1 x 4.0 sq.mm. earth wire | Item no.91 | 150 | \nMtr. |
| 92 | 92 | S/F PVC conduit - \nSupplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required.\n20mm | Item no.92 | 90 | \n Mtr. |
| 93 | 93 | S/F PVC /G.I. boxes - \nSupplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.\n75mm x 75mm x 50mm deep/(4\" x 4\") | Item no.93 | 24 | Each |
| 94 | 94 | Telephone wiring in existing conduit - \nSupplying and drawing following pair, 0.5 sq.mm FR PVC copper conductor, unarmoured telephone cable in the existing surface/recessed PVC conduit as required.\n2 Pair | Item no.94 | 120 | Per Mtr. |
| 95 | 95 | TV cable in existing conduit - \nSupplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit as required. | Item no.95 | 120 | Mtr. |
| 96 | 96 | S/F Modular type switch/socket on the existing switch\n box including connection etc. as required\n5/6 amp. Switch & 3 pin 5/6 amp. Socket/outlet | Item no.96 | 32 | Each |
| 97 | 97 | S/F Modular type switch/socket on the existing switch\n box including connection etc. as required\n3 pin 5/6 amp. Socket/outlet | Item no.97 | 32 | Each |
| 98 | 98 | S/F Modular type switch/socket on the existing switch\n box including connection etc. as required\nTelephone socket outlet | Item no.98 | 4 | Each |
| 99 | 99 | S/F Modular type switch/socket on the existing switch\n box including connection etc. as required\nTV antenna socket outlet | Item no.99 | 4 | Each |
| 100 | 100 | S/F Modular type electronic fan regulator -\nSupplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | Item no.100 | 10 | Each |
| 101 | 101 | S/F suitable size G.I. box with modular plate and cover \nin front on surface or in recess including P.F. 3 pin 5/6 amp. Modular socket outlet and 5/6 amp. Modular switch connection painting etc. as required | Item no.101 | 12 | Each |
| 102 | 102 | S/F suitable size G.I. box with modular plate and\n cover in front on surface/recess including P/F 6 pin 15/16 amp. And 5/6 amp modular socket outlet and 15/16 amps. Modular switch connection as painting etc. as required | Item no.102 | 16 | Each |
| 103 | 103 | S/F 3 pin 5 amp ceiling rose on the existing junction \nbox wooden block including connection etc. as required | Item no.103 | 112 | Each |
| 104 | 104 | S/F brass vatton/Angle Holder including connection etc. as required | Item no.104 | 40 | Each |
| 105 | 105 | S/F Dingdong call bel - \nSupplying and fixing dingdong call bell suitable for D.C/A.C single phase, 2230 volts, complete as required. | Item no.105 | 1 | Each |
| 106 | 106 | ITC fluorescent fitting directly on surface - \nInstalltion, testing and commissioning of Pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm. FR PVC insulated, copper conduit. | Item no.106 | 70 | Each |
| 107 | 107 | I.T.C of ceiling fan including wiring the down rods of\nstandard length (Up to 30 cm) with 1.5 sq.mm FRPVC with 1.5 sq.mm. FRPVC insulated copper conductor single core cable etc. as required | Item no.107 | 10 | Each |
| 108 | 108 | I.T.C of exhaust fan up to 450mm sweep in the existing \nopening including making the hole to suit the size of the above fan making good the damage connection testing commissioning etc. as required | Item no.108 | 4 | Each |
| 109 | 109 | S/F T.P. MCB DB - \nSupplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)\n4 way (4 + 12), Double door, Horizontal type | Item no.109 | 12 | Each |
| 110 | 110 | S/F T.P. MCB DB - \nSupplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)\n6 way (4 + 18), Double door, Horizontal type | Item no.110 | 9 | Each |
| 111 | 111 | S/F 5 amp. To 32 amp rating 240 volt \"C\" series miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc. as required.\n6/32 amps, single pole, \"B\" series | Item no.111 | 6 | Each |
| 112 | 112 | S/F 'C' series, MCB - \nSupplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required.\n40 amps, TPN | Item no.112 | 8 | Each |
| 113 | 113 | S/F 'C' series, MCB - \nSupplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required.\n50/63 amps, TPN | Item no.113 | 4 | Each |
| 114 | 114 | S/F following rating single pole 240 volts isolator in the\n existing MCB DB complete with connection testing and commissioning etc. a srequired\n40 amp | Item no.114 | 6 | Each |
| 115 | 115 | S/F following rating single pole 240 volts isolator in the\n existing MCB DB complete with connection testing and commissioning etc. a srequired\n63 amp | Item no.115 | 8 | Each |
| 116 | 116 | Earthing with G.I. earth pipe 4.5 mtr. Long, 40mm dia \nincluding accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required. | Item no.116 | 1 | P/Set |
| 117 | 117 | Copper earth plate elecrtode - \nEarthing with copper earth plate 600mmx 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (But without charcoal or coke and salt) | Item no.117 | 1 | P/Set |
| 118 | 118 | Salt/Charcoal for plate earth electrode - \nExtra for using salt and charcoal for G.I. or copper plate earth electrode as required. | Item no.118 | 1 | P/Set |
| 119 | 119 | S/L 8 SWG copper wire at 0.50 metre below ground level\nfor conductor earth electrode including soldering etc. as required | Item no.119 | 30 | Mtr. |
| 120 | 120 | P/F lighting conductor final made of 25mm dia 30omm\n long copper tube having single pole at top with 85mm dia 3mm thick copper base plate including holes etc. complete as required | Item no.120 | 1 | Each |
| 121 | 121 | Reverting sweating and soldering of copper/G.I. tape (with another\ncopper G.I. tape base of the final or any other metalic object) as required | Item no.121 | 30 | Mtr. |
| 122 | 122 | P/F copper lightning conductor tape in horizontal run - \nProviding and fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) | Item no.122 | 42 | Mtr. |
| 123 | 123 | P/F copper lighning conductor tape in vertical run - \nProviding and fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) | Item no.123 | 30 | Mtr. |
| 124 | 124 | P/F testing joint made of 20 x 3mm thick copper strip\n 125mm long with 4 nos. of tinned brass bolts nuts check nuts and spring washers etc. complete as required | Item no.124 | 1 | Each |
| 125 | 125 | MV Cable Laying upto120 Sq mm in ground:- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc, as required. | Item no.125 | 30 | Mtr. |
| 126 | 126 | MV Cable Laying upto400 Sq mm in ground:- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc, as required. | Item no.126 | 30 | Mtr. |
| 127 | 127 | Supply 1200mm ceiling fan Bajaj/cromption or any other approved\nmake etc. without regulator | Item no.127 | 4 | Each |
| 128 | 128 | S/F 18 watt LED | Item no.128 | 40 | Each |
| 129 | 129 | 1X28 watt T5 Tube light fitting | Item no.129 | 15 | Nos. |
| 130 | 130 | Supply of Wallmounted Fan : Supply of 16\"(400mm), 230V AC wall/cabin fan including fixing the bracket, making , connection testing, commissioning etc as required( Make- Polar/Bajaj/ Havells/Crompton) | Item no.130 | 16 | Nos. |
| 131 | 131 | Supply 12\" dia Khaitan India exhaust fan etc. all required | Item no.131 | 4 | Each |
| 132 | 132 | BORING\nCost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.\n(a) From 0.00 M to 50.00 M below G.L. | Item no.132 | 50 | M |
| 133 | 133 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.\n(b) From 51.0 M to125.00 M | Item no.133 | 75 | M |
| 134 | 134 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.\n(c) From126.0 M to150.00 M | Item no.134 | 125 | M |
| 135 | 135 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.\n200 mm nominal size dia | Item no.135 | 50 | M |
| 136 | 136 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \"V\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge | Item no.136 | 2 | Hours |
| 137 | 137 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:\n200 mm dia | Item no.137 | 2 | Each |
| 138 | 138 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.\n200 mm clamp | Item no.138 | 2 | Each |
| 139 | 139 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.\nSubmersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages\n3 HP | Item no.139 | 1 | Each |
| 140 | 140 | Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes ,royalty etc all complete job as per direction of E/I. | Item no.140 | 1 | Each |
| 141 | 141 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. | Item no.141 | 160 | M |
| 142 | 142 | Supply fitting and fixing lowering 50 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I. | Item no.142 | 160 | M |
| 143 | 143 | GST @ 12% | Item no.143 | 0.12 | Per. |
| 144 | 144 | Labour cess @ 1% | Item no.144 | 0.01 | Per. |
AI Tender Summary
Tender Timeline
Jun 08, 2021
11:30 IST
Tender Published
Tender notice published.
Completed
Jun 11, 2021
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedJun 11, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJun 12, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender