Special Repairs/Replacement Of Ht Oh Conductor To Ht Cable 95Sqmm 3 Core And Allied Works From 2 Pole Structure Near Div Hq Sub Stn To Rupa Water Point Sub Stn And 25Sqmm 4 Core Xlpe Cable From 100 Kva Transformer To Single Offrs Accn At Offrs Mess, GE 859 EWS-Arunachal Pradesh

Military Engineer Services-MES has published Special Repairs/Replacement Of Ht Oh Conductor To Ht Cable 95Sqmm 3 Core And Allied Works From 2 Pole Structure Near Div Hq Sub Stn To Rupa Water Point Sub Stn And 25Sqmm 4 Core Xlpe Cable From 100 Kva Transformer To Single Offrs Accn At Offrs Mess. Submission Date for this Tender is 21-06-2021. Overhead Line Tenders in GE 859 EWS Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28096220
Corrigendum : Special Repairs/Replacement Of Ht Oh Conductor To Ht Cable 95Sqmm 3 Core And Allied Works From 2 Pole Structure Near Div Hq Sub Stn To Rupa Water Point Sub Stn And 25Sqmm 4 Core Xlpe Cable From 100 Kva Transformer To Single Offrs Accn At Offrs Mess
Open Tender
Indian
Arunachal Pradesh
GE 859 EWS
21-06-2021

Tender Details

Special Repairs / Replacement Of Ht Oh Conductor To Ht Cable 95Sqmm 3 Core And Allied Works From 2 Pole Structure Near Div Hq Sub Stn To Rupa Water Point Sub Stn And 25Sqmm 4 Core Xlpe Cable From 100 Kva Transformer To Single Offrs Accn At Offrs Mess

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Jun-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-06-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 56000.0 /-
Tender Value
INR 28 Lakhs /-

BOQ Items

Nature of Work : SPL REPAIRS/REPLACEMENT OF HT OH CONDUCTOR TO HT CABLE 95SQMM 3 CORE AND ALLIED WORKS FROM 2 POLE STRUCTURE NEAR DIV HQ SUB STN TO RUPA WATER POINT SUB STN AND 25SQMM 4 CORE XLPE CABLE FROM 100 KVA TRANSFORMER TO SINGLE OFFRS ACCN AT OFFRS MESS AND PROVN OF STAND BYOH HT LINE FROM POWER HOUSE TO MH UNDER GE 859 EWS.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles/laying of under ground cables etc and getting out in hard/dense soil complete all as specified and as directed. 231.51 Cum
2 2 Excavating in Trenches, not exc. 1.50 Metre wide and exc. 1.50 Metre but not exc. 3.00 Metre in depth, for Foundation of Pole/Stays, etc. and getting out in hard/dense Soil, complete all as specified and as directed. 2.484 Cum
3 3 Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed. 156.38 Cum
4 4 Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. 74.55 Cum
5 5 Dismantling unserviceable Steel Tubular Poles of any description and any size including demolition of Cement Concrete (as/if required) and made good disturbed Ground, complete all as specified and as directed. 4 Each
6 6 Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed. 2.43 Qtl
7 7 Dismantling of lightning arrestor of any capacity complete all as specified and as directed. 2 Set of \nThree
8 8 Dismantling & taking down ACSR conductor complete from existing position complete all as specified and directed. 2.3 Qtl
9 9 Dismantling & taking down old/unsv HT pole complete from existing position complete all as specified and directed. 8 Each
10 10 Dismantling & taking down disc/pin type insulators complete all as specified and directed. 27 Each
11 11 Taking down XLPE cable any size/capacity, complete all as specified and directed 400 RM
12 12 Taking down LT panel including MCCB, MCB any size/type, complete all as specified and directed 1 Each
13 13 M&L for PCC (1:4:8) type D2 using 40mm graded aggregate as in foundation for filling in, mass concrete for pole, stay, pole base and transformer foundation complete all as specified and directed. 7.73 Cum
14 14 M&L for PCC (1:3:6) type C1 using 20mm graded aggregate as in mass filling of pole including necessary form work complete all as specified and directed. 4.26 Cum
15 15 PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole , top surface of plinth etc, including necessary form work complete all as specified and directed 0.31 Cum
16 16 Supply and spreading clean dry river sand in trenches for cushioning of UG cables complete all as specified and directed. 58.01 Cum
17 17 Supply and laying in replacement un-reinforced precast concerete cable cover, class HV, type 1 flat size 300mm x180mm x 40mm for cable protection complete all as specified and directed. 2350 Each
18 18 Supply and laying in replacement un-reinforced precast concerete cable cover, class HV, type 1 flat size 250mm x150mm x 40mm for cable protection complete all as specified and directed. 1333 Each
19 19 Supplying, laying, jointing, testing and commisioning HT 11 KV (E) XLPE cable, insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, size 3 core & cross section area 95 Sqmm laid in trenches/pipes/ducts/along poles/walls/ equipment etc complete all specified and directed.\nNote :-Payment for excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be made for separately under relevant item of Scedule 'A'. 540 RM
20 20 Supplying, laying and testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 Volts grade with stranded aluminium conductor, of size 4 core & cross section area 25 Sqmm laid in trenches/pipes/ducts/along poles/walls/ equipment etc complete all specified and directed. \n 400 RM
21 21 S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm incl dismantling and taking down old unsv complete all as specified and directed. 6 Each
22 22 S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm incl dismantling and taking down old unsv complete all as specified and directed. 1 Each
23 23 S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed. 2 Each
24 24 M&L for steel tubular swaged pole complete with cast iron base plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-55 (11 mtr long) complete all as specified and directed. \n 14 Each
25 25 S&F Switch Air break, gang operated, triple pole, mechanically operated mounted on 12 insulators of size 150mm dia and 150 mm height and steel frame with operating mechanism worked from ground level for current rating upto 200 Amps, 11000 Volts with locking arrangement incl drop out fuse upto 25 Amp incl dismantling and taking down old unsv complete all as specified and directed. 2 Each Set
26 26 S&F GI tubing 100mm bore medium grade for cable protection on pole / trench incl dismantling and taking down old unsv complete all as specified and directed. 18 RM
27 27 M&L for GI tubing light grade 80 mm dia galvanised with all fittings laid in trenches as protection of cable complete all as specified and directed. 18 RM
28 28 S&F Cross arms including replacement of bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. 7.93 Qtl
29 29 S&F of lightning arrestor high tension, expulsion type, distribution class, System voltage-12KV, min rating-10KV, Discharge cap-65 KA, Line discharge class-1 complete with bracket and connection complete all as specified and directed. \n 8 Set of Three
30 30 S&F Danger notice plate of 1.6mm thick mild steel sheet , vitreous enamelled white , with letters , figure and conventional skull and bone in signal red colour and fixed with MS clamps , bolts and nuts of approved size for HT, 25x20cm size complete all as specified & directed . 12 Each
31 31 M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below notmal ground level, connected to galvanised iron earth strip 32x6mm upto test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including light grade GI watering pipe 20mm bore with funnel wire mesh and medium grade GI wire protection pipe 40mm bore up to main board completew as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete ass as specified and testing on completion complete ass as specified and directed by Engineer-in-charge. Note - The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 20mm GI pipe (light grade) for watering 40mm GI protection pipe (medium grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. 12 Each Set
32 32 S&F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc., fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., complete all as specified and as directed.\nNOTE: Cost of Binding Wire is deemed to be included in the QUOTED UNIT RATE. 1.24 Qtl
33 33 M&L for Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 20mm, size of Plate 300x500x6mm, complete all as specified and as directed.\nNOTE: Earthwork, Cement Concrete, Mild Steel Stay Clamps with Bolts, Nuts, etc., Loop Insulator, etc. will be measured and paid under approprite Items.\n 2 Each
34 34 S&F Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 550 volts grade, complete all as specified and as directed. 24 Each
35 35 S&F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green 'Two-in-series' assembly for tension with tension clamps for conductors working pressure 11000 volts,complete all as specified and as directed. 6 Each
36 36 S&F Galvanised steel wire fixed on pole without kinks and bends of size 3.15 or 4mm dia complete all as specified and as directed. 1.3 Qtl
37 37 M&L Anti-climbing device spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed. 0.15 Qtl
38 38 Supply, install, testing and commissioning of LT Panel Board 'out door type' of size 1000mm x 1000mm x 500mm (minimum dimensios) CPRI approved factory made with suitable neoprene rubber gasket to make it completely dirt & vermin proof and degree of protection not less than IP-55 and general construction conforming to IS-13947, double door front and back openable & 4 side slanting canopy on roof top. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation by tinned copper bus bar wrapped with colured PVC tape/sleeves of rating in conformity to the incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.00 mm thick CRCA sheet duly pre-treated & powder coated supporting frame made out of 50X50X50mm angle iron & MC 100 channel base suitable for 3 ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable grands of suitable size incl suitable PCC (1:3:6) type C-2 and cable joint with lugs in MCCBs/MCB.\n(a) MCCB 200 Amp, 4P, 50 Hz, 415 V with rupturing capacity 35 KA - 01 No (incoming)\n(b) MCB 63 Amp TPN, 50 Hz, 415 Hz, 415 V - 05 Nos\n(c) Digital type AC volt meter with built in selector switch, 3 phase, 10-100A volts range, accuracy class-0.5, size 96X96mm. Model No AE 60332 of Make AE\n(d) Digital type AC Ammeter 0 to 100 A with built in selector switch & 03 Nos CTs (Type : CBF-0.6-D1) Accuracy class - 1.0, CT Ratio-600/5, Burden-15VA), 3 Phase, Accuracy class-0.5, size 96X96mm. Model No AE 62332 of Make AE.\n(e) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, orange, Blue) - 01 set. 1 Each Job