}

Construction Of U Value Apparatus For Full Scale Building Component Testing Civil, Electrical And Mechanical Works, Director CSIR CBRI Roorkee-Uttarakhand

Council Of Scientific And Industrial Research-CSIR has published Construction Of U Value Apparatus For Full Scale Building Component Testing Civil, Electrical And Mechanical Works. Submission Date for this Tender is 14-06-2021. Electromechanical Work Tenders in Director CSIR CBRI Roorkee Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

28076855
Construction Of U Value Apparatus For Full Scale Building Component Testing Civil, Electrical And Mechanical Works
Open Tender
Indian
Uttarakhand
Director CSIR CBRI Roorkee
14-06-2021

Tender Details

Construction Of U Value Apparatus For Full Scale Building Component Testing Civil, Electrical And Mechanical Works

Key Value

Document Fees
INR 590 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Construction of "U" Value Apparatus for Full Scale Building Component Testing
Sl. No. Item Description
1Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
2Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
3Providing unskilled labour for emergentworks like cleaning of roofs , uprooting the wild vegetation from roof /outer walls /rain water pipes etc. of staff quarters and misc. other works as per the direction of Engineer in charge.
4Providing skilled manpower for shifting of various items, furneture,old testing models and materials from construction site to specified space in the institute as per direction of Engineer-in-charge
5Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
6Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below
7Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
8Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50metres lead
9Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge
10Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
11Providing Tractor trolly for shifting of malba, debrise, soil, various old testing models and materials from construction site to outside of institute and out site area of nagar nigum Roorkee including loading unloadingcomplete work in all respect as per direction of Engineer-in-charge.
12Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead :
13Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m All kinds of soil.
14Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
15Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
16Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
17Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
18Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
19Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick
20Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Light shade pigment using white cement
21Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
22Brick work in superstructure of class designation 75 in Cement mortar 1:6 (1 Cement : 1 coarse sand).
23Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
24Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
25Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
26Centering and shuttering including strutting, propping etc. and removal of form for :
27Foundations, footings, bases of columns, etc. for mass concrete
28Suspended floors, roofs, landings, balconies and access platform
29Lintels, beams, plinth beams, girders, bressumers and cantilevers
30Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars
31Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :100x10
32Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.50 mm
33Providing and fixing bright finished brass handles with screws etc. complete:100 mm
34Providing and fixing magnetic catcher of approved quality in cupboard /ward robe shutters, including fixing with necessary screws etc. complete.Double strip (horizontal type)
35Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
36Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper.
37Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete
386 mm thick cement plaster on ceiling with cement mortar 1:3 (1cement: 3 fine sand).
3912 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand.
4015 mm thick cementplaster rough side brick work 1:6 cementmortar(1cement :6 coarse sand) .
41Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
42Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
43Grinding and polishing of existing floor including labour T&P material complete in all respect at site asper direction of engineer-in-charge.
44Providing insulation inside doors with interlocking precoated PUF panel having GI sheet on both sides with 150mm thick, PUF insulation denstiy :38kg/cum, PUF thermal conductivity : 0.035W/m/K at 30 deg.C mean temperature, Facing material: Powder coated GI sheet, Facing Material thickness : 0.6mm, including complete in all respect at site as per direction of Engineer-in-charge.
45Providing insulation inside walls, floors, and roofs with interlocking precoated PUF panel having GI sheet on both sides with 150mm thick, PUF insulation denstiy :38kg/cum, PUF thermal conductivity : 0.035W/m/K at 30 deg.C mean temperature, Facing material: Powder coated GI sheet, Facing Material thickness : 0.6mm, including complete in all respect at site as per direction of Engineer-in-charge.
46Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
48Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
49Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
50Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
51Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
52Wiring for light Point /fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit with modular switch of Havells Modular /Legrand MOSAIC /Anchore ROMA/ Make or its equivelent make ,ISI marked, modular plate suitable G.I Box and earthing the point with 1.5 sq mm FRLS PVC insulated multi strand copper conductor single core cable of Polycab/Havell’s /KEI Cables /RR Kable/Finolex make or its equivelent make I.S.I. marked 1100 volts grade as required for Group ‘C’Point including ceiling rose or lamp holder as required
53Wiring for circuit /sub-main wiring along with earthwire the following size of FRLS PVC Insulated multi standard copper conductor single core cable of Polycab/Havell’s /KEI Cables /RR Kable/Finolexmake or its equivelent make I.S.I marked 1100Volts grade in surface/ recessed steel conduit as required
542 x 1.5 sqmm + 1 x 2.5 sqmm earth wire
552 x 2.5 sqmm + 1 x 2.5 sqmm earth wire
562 x 4 sqmm + 1 x 4 sqmm earth wire
572 x6 sq.mm + 1 x 6 sqmm earth wire
584 x6 sq.mm + 2 x 6 sqmm earth wire
59S/F 4module GI box of size 125 x 75 mm along with modular base and cover plate for modular switches in recess etc as required.complete in all respect.
60Supply and fixing 5/6 Amps Modular type switch on the existing Modular plate & switch boxincludingconnections but excluding modular plate etc. as required complete in all respect.
61Supplying and fixing 3 pin 5 amp.ceilingrose on the existing junction box /wooden block including connection etc as required
62Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required.
63Supply and fixing suitable size G.I Box with modular plate and cover in front on surface/recessed including P/F 5 pin 5/6 Amps modular socket outlet and 5/6Amps modular switch of Havells Modular /Legrand MOSAIC /Anchore ROMA/ Make or its equivelent make,ISI marked, connections painting etc as required
64Supply and fixing suitable size G.I Box with modular plate and cover in front on surface/recessed including P/F 6 pin 15/16 Amps and 5/6 Amps modular socket outlet and 15/16Amps modular switch of Havells Modular /Legrand MOSAIC /Anchore ROMA/ Makeor its equivelent make ,ISI marked, connections painting etc as required
65Supply and fixing 20 amps 240 Volts SPN industrial type socket outlet with two pole and earth metal enclosed plug top along with 20 Amps ‘C’ Cueve, SP, MCB, in sheet steel enclosure, on surface or in recesses with chained metal cover for the socket outlet complete with connection, testing, commissioning etc. as requiredof Havells / Legrand /L&T/ Sciemense Make or its equivelent make .
66Supply and fixing 30 amps 415 Volts TPN industrial type socket outlet with four pole and earth metal enclosed plug top along with 32 Amps ‘C’ curve, TPMCB in sheet steel enclosure on surface or in recesses with chained metal cover for the socket outlet complete with connection, testing, commissioning etc. as required of. Havells / Legrand /L&T/ Sciemense/ABB Make or its equivelent make.
67Supply and Fixing8Way double doorsurface/recess mounting vertical type415 volts,TPN, MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bars, common neutral link, earthbar, dinbar for mounting MCB’s (But without MCBs and incomer MCCB)of Havells make model load lineor its equivalent of Legrand/ABB /L&T/ Sciemense Make or its equivelent make including paintingearthing etc. as required.
68Providing and fixing 100 amps 16 KA rating and breaking capacitythreepole MCCB in existing cubical panel board including drilling holes in cubical panel making connection etc. including testing and commissioning. as requiredofLegrand/ Havells /L&T/ Sciemense Make or its equivelent make .
69Supply and fixing 5amps-to- 32 amps rating 240/415 Volts C Curve miniature circuit Breaker suitable for inductive loads of Single Pole in the existing MCB DB complete with connections, testing and commissioning etc as requiredofLegrand/ Havells /L&T/ Sciemense Make or its equivelent make .
70Earthing with G.I. earth plate 600mm x 600mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etcwith charcoal / coke and salt complete as required.
71Supply and laying25mmx5mm G.I strip at 0.50 meter below ground as strip earth electode,incluidinng connection/terminating with G.I.Nut,bolt,spring,washer etc. as required.
72Providing and Laying 6 SWG G.I. wire at 0.5 mbelow ground level for conductor earth electrode including connectionter mination withG.I. thimbleetc. as required.
73Laying of one number PVC insulated and PVC sheathed/ XLPE aluminium conductor power cable of 1.1 KV grade of size Above 35 sq.mm andUp to95 sq.mmin the existing RCC/HUME/ METAL/ DWC HDPE pipe etc. as required.
74Laying of one number PVC insulated and PVC sheathed/ XLPE aluminium conductor power cable of 1.1 KV grade of size Above 185 sq.mm andUp to400 sq.mm in the existing RCC/HUME/ METAL/ DWC HDPE pipeetc. as required.
75Supplying and laying of 90 mm dia (OD-90 mm & ID-76 mm nominal) sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
76Supplying and making indoor end termination with brass compression gland and aluminium lugs for 3.5 x 70 sq.mm(38 mm )size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
77Supplying and making indoor end termination with brass compression gland and aluminium lugs for 3.5 x 240 sq.mm(62 mm )size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
78Supplying & Fixing of 32 mm diax2.00 meters long G.I. pipe(medium class) bracket for mounting ofstreet light fitting on wall including bending the pipe to the required shape,40mmx3mm flate iron clamp and wiring with1.5 sq.mm wp/pvc wire and painting the flate iron with primer and finish paint etc. as required
79Taking out carefully old electric point wiring, sub-main, switch board, Power Points and electrical fitting & fixtureincluding all other old electrical items taken under renovation area complete in all respect and shifting of old materials as required.
80Supply and fixing 1400 mm sweep double ball bearing type heavy duty ceiling fan ofHavells make model velocity/velocity HS or equivelent of cinni/ crompton makecomplete in all respect as required and directed by the Engineer –in-charge.
81Supply andfixing factory wiredHavellsmake STOUT PLUSLED Light battens 0f 40 watt including suitable size M.S.Patticat.no. STOUTPLUS1200BS40WLED840(or 857)SPCWH or its equivalent make of Bajaj/Phillips make complete in all respect as required.
82Supply for laying, including testingconnecting etc. in the existing trench/ surface/ wall PVC insulated and PVC sheathes XLPE armoured heavy duty 1100 volts grade Gems Cab /Havell’s/Poly Cab/KEI make ISI marked,Heavy Duty, aluminium conductor electric cable as per latest I.S.Spesification, including connection testing etc complete in all respect as requiredof size 3.5corex70 sq.mm
83Supply for laying including testing,connecting etc. in existing trench/ surface/ wall PVC insulated and PVC sheathes XLPE armoured heavy duty 1100 volts grade Gems Cab /Havell’s/Poly Cab/KEI make or its equivelent make ISI marked,Heavy Duty, aluminium conductor electric cable as per latest I.S.Spesification, including connection testing etc complete in all respect as required and directed by engineer Incharge of size 3.5corex240 sq.mm
84S/F LED Street Light fixture of new generation energy saving and environmental friendly long life LED Street Lightmade up of pressure die cast aluminium housing with high power LEDas lighting source and lens embedded PC cover having TOP OPENING seprate driver compartment with ,IP66protection andimpact resistance of IK07 with10 KV Built-in Surge protectionDeviceof Havells make 90 Watt 230 volts odering code ENDURAPEARLPLUSSL90WLED757SASYTOPC or its equivalent make of Bajaj/ Phillips make complete as required
85Supplying installation, testingcommissioning, of Indoor type totally enclosed floor mounted Panel board of 600 mm deep having fully compartmentalizedFactoryfabricated from 2mm thick CRCA sheet steelwith base frame mounted on cement concrete foundation/ MS Angle iron frame of size 50mmx50mmx5mm thick, ,including making of suitable size cable trench for installation of cubical type LT Panel board of size 2200mmx1800mmx600mm suitable for 415 V,3phase, 4wire 50Hz AC Supply system,3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade having extensible type a TPN aluminium Alloy bus bar of high conductivity, DMC/SMC bus bar supports fabrication shall be done in transportable section entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 02 Nos. earth stud ,solid connections from main bus bar to switch gear with required size of AL.bus bars ,gland plates including indicating lamps on incoming etc.The instruments chamber shall be separate and shall comprise of flush type ammeter, voltmeter selector switches for ammeter and voltmeter instruments SP MCB etc in two half i/c providing following switch gears (I)Incomings:(1) 02 Nos.-400 Amps 4 pole MCCB for fault breaking capacity 35KA. (2)01Nos.400 Amps 4 Pole on load Change Over Switch (II)Bus Bars:TPN aluminium bus bars of minimum of 600Amps capacity 4 strip “with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section side supports (III)Outgoings:2. (1)02 Nos. 200 Amps 4 pole MCCB 25KA 3. (2)02 Nos. 100 Amps 4 pole MCCB 16KA
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail