| 1 | 1 | Taking down high pressure SV/MV/MH /FTL/LED street light fitting/Flood Light fittings of any wattage/any height of pole/walls/any location for repairs or replacement of burnt out the accessories and rectifying the fault complete all as specified and as directed.\nNote: LED Drivers, Surge protection, cables, etc. for rectifying shall be measured and paid separately under relevant items here-in-after.\n | | 117 | Each |
|---|
| 2 | 2 | Fixing only for street light fittings/flood lights after duly repaired of the any wattage on poles/walls, etc. and at any height comprising of LED Drivers, Surge protection, etc. with copper cables in prewired suitable for mounting on existing/new 40mm/25mm GI pipe bracket, arms with pole fixing attachments and other connected to electrical connections and testing complete all as specified anda as directed.\nNote : GI pipe brackets & Copper cable shall be measured and paid separately under respective items here-in-after. | | 85 | Eeach |
|---|
| 3 | 3 | S&F LED 72 watts street light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 66 protection luminaries complete all as specified and as directed.\nMake: Crompton, Cat Part No. LSTP-72-CDL or equivalent model of make Bajaj/Surya Roshni Ltd. | | 71 | Each |
|---|
| 4 | 4 | All as per Serial item No. 3 here-in-before but 100 Watts\nMake : Crompton, Cat Part No. LSTP-100-CDL or equivalent model of make Bajaj/Surya Roshni Ltd. | | 35 | Each |
|---|
| 5 | 5 | S&F LED 170 watts Flood light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 66 protection luminaries complete all as specified and as directed.\nMake : Crompton, Cat Part No. LSFO-170-CDL/60 or equivalent model of make Bajaj/Surya Roshni Ltd. | | 6 | Each |
|---|
| 6 | 6 | All as per Serial item No. 5 here-in-before but 200 Watts.\nMake: Crompton, Cat Part No. LSFO-200-CDL/60 or equivalent model of make Bajaj/Surya Roshni Ltd. | | 5 | Each |
|---|
| 7 | 7 | S&F 5 KV surge for LED street light, 230 volts, 50 Hz compatible for industrial & outdoor LED fixtures up to rated power of 75 watts for fixing in repairs complete complete all as specified and as directed.\nMake : Crompton/Surya Roshni Ltd/Bajaj | | 20 | Each |
|---|
| 8 | 8 | S&F 5 KV surge for LED street light, 230 volts, 50 Hz compatible for industrial & outdoor LED Fixtures rated power above 75 watts & upto 150 watts for fixing in repairs complete all as specified and as directed.\nMake : Crompton/Surya Roshni Ltd/Bajaj | | 15 | Each |
|---|
| 9 | 9 | S&F Drivers for LED street lights 25W/30W, 230 Volts, 50 Hz complete all as specified and as directed.\nMake : Crompton/Surya Roshni Ltd/Bajaj | | 15 | Each |
|---|
| 10 | 10 | S&F Drivers for LED street lights 45W/60W, 230 Volts, 50 Hz complete all as specified and as directed.\nMake : Crompton/Surya Roshni Ltd/Bajaj | | 15 | Each |
|---|
| 11 | 11 | S&F Drivers for LED Flood lights 100W/120W, 230 Volts, 50 Hz complete all as specified and as directed.\nMake : Crompton/Surya Roshni Ltd/Bajaj | | 6 | Each |
|---|
| 12 | 12 | S&F Decorative Post top for 360 degree indirect light with IP 65 protection, 230 volts complete all as specified and as directed.\nMake : Crompton, Cat Part No. LPTO-60-CDL or equivalent model of make Surya Roshni Ltd/ Bajaj/Havells | | 12 | Each |
|---|
| 13 | 13 | S&F timelite distrubution board 32A, 3 pole, 230 volts Digital time switch complete all as specified and as directed.\nMake : Indo Asian, Cat No. TL032DBO or equivalent model of make L&T/Siemens | | 2 | Each |
|---|
| 14 | 14 | S&F 1100 volts, heavy duty round sheathed multistranded three core bright annealed bare copper conductor cable of size 2.5 Sq.mm for electrical connections to the street lights fittings including taking out old cable complete all as specified and as directed.\n\n | | 100 | RM |
|---|
| 15 | 15 | M&L for painting of the swaged steel tubural LT poles of any length including cross arms, clamps and light bracktes surface of any discription after preparation of old painted surface (removing old paint by paint removers and cleaning with scraper any number of exiting coats) with one finishing coat aluminium paint and marking pole no. as per exiting numbers and painting of lower portion of the pole in alternate layer of black and yellow shades/colour complete all as specified and as directed.\n | | 110 | Each Job |
|---|
| 16 | 16 | All as per Serial item No. 15 here-in-before but swaged steel tubural HT poles of any length. \n | | 12 | Each Job |
|---|
| 17 | 17 | M&L for 40mm dia GI pipe, light grade, bracket 1.5m in length, bend to shape as required for fixing street light fitting complete including taking out old unserviceable one complete all as specified and as directed. | | 20 | Each |
|---|
| 18 | 18 | Taking down old unserviceable XLPE LT Underground Cable complete all as specified and as directed. \nNote: Necessary excavation & earth work shall be measured and paid separately under respective items. | | 600 | RM |
|---|
| 19 | 19 | Supply, laying and testing LT underground cable XLPE insulated and sheathed armoured cable, 1100 volts, 2 core, 10 Sq.mm aluminium conductor as in trenches/poles and connecting with all accessories complete all as specified and as directed. | | 150 | RM |
|---|
| 20 | 20 | All as per Serial item No. 19 here-in-before but of cable 4 core, 16 Sq.mm. | | 200 | RM |
|---|
| 21 | 21 | All as per Serial item No.19 here-in-before but of cable 3.5 core, 25 Sq.mm | | 250 | RM |
|---|
| 22 | 22 | Supply only lugs for UG cable for 3.5/4 core, 16 Sq.mm to 70 Sq.mm complete all as specified and as directed. | | 50 | Each Job |
|---|
| 23 | 23 | Excavation in trenches not exeeading 1.5m wide and not exceeding 1.5m in depth/width and getting out in loose/soft soil for laying under ground cable complete all as specified and as directed. | | 120 | Cum |
|---|
| 24 | 24 | Returning, filling in, including spreading, levelling and well ramming in layers not exc. 25 cm in thick complete all as specified and as directed. | | 68 | Cum |
|---|
| 25 | 25 | Removal of excavated surplus soil to a distance not exc. 50m away and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. | | 52 | Cum |
|---|
| 26 | 26 | Supply and spread sand in trenches for protection and providing cushioning for the cable complete all as specified and as directed.\nNote: Only punned thickness of 18 cm will be measured for the purpose of payment.\n | | 36 | Cum |
|---|
| 27 | 27 | Supply and laying burnt out sub class 'B' brick of size 230 x 115 x 75mm for protection of cable for laying in trenches complete all as directed. | | 4 | Per 1000 Nos |
|---|
| 28 | 28 | S&F GI tubing of 50mm dia, light grade at crossing of road for cable protection as per site requirement and sealing the pipe both ends with sealing compound including taking down old one complete all as specified and as directed.\n\n | | 20 | RM |
|---|
| 29 | 29 | All as per Serial item No. 28 here-in-before but 40mm dia. | | 20 | RM |
|---|
| 30 | 30 | S&F of pin type, porcelain vitreous, while, brown or green insulator including one Galvanised mild steel spindle, two galvanised iron washers and one Galvanised iron nut, 100mm height, 65mm dia for 1100 volts including taking down old unserviceable insulator complete all as specified and as directed. | | 15 | Each |
|---|
| 31 | 31 | S&F of shackle type insulator, porcelain, virtuous, white, brown or green insulator, 75mm height, 90mm dia for 1100 volts grade including one Galvanized mild steel straps washers insulator bolts, washers and nuts including taking down old unserviceable insulator complete all as specified and as directed. | | 10 | Each |
|---|
| 32 | 32 | Restringing only LT over head ACSR conductor after free from pin, disc, shackle type insulators, binding with and including binding wire to insulators and connecting in 4 conductors system in position complete all as specified and as directed.\nNote: 4 run of ACSR conductor will be measured as one length. | | 2000 | RM |
|---|
| 33 | 33 | M&L for PVC line separator suitable for 4 wire LT over head lines at any height and position complete all as specified and as directed. | | 40 | Each |
|---|
| 34 | 34 | M&L for PVC line separator suitable for 2 wire LT over head lines at any height and position complete all as specified and as directed. | | 25 | Each |
|---|
| 35 | 35 | S&F HOT moulded (FRP) jucntion box for street light pole with locking arrangementt with IP-65 protection of size 280 x 200mm, 32 Amp, 4 way, heavy duty, terminal block with 10 Amps MCB SP and two steel bracket to fixing with pole complete all as specified and as directed. Make : Hansel/Sintex and/or any make approved in MES subject to submission copy of approval letter. | | 30 | Each |
|---|
| 36 | 36 | M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking down of old unserviceable one complete all as specified and as directed. | | 1 | Qtl |
|---|
| 37 | 37 | M&L for triming of tree branches (touching HT/LT over head line) uptto 10cm width or girth, at any height and position after shutdown electrical line (live electrical line to be shutdown prior intimation well in advance) including disposal off the cut of tree branches complete all as specified and as directed.\nNote:- Tools & plants including safety measures and equipments like belt, ladder, rops, etc shall be arranged by the contractor at his own cost and to be inclusive in quoting rate. | | 40 | Each Tree |
|---|
| 38 | 38 | Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not exc. 60m complete all as specified and as directed. \nNote : Item shall be executed twice in each installation and quantity is given for two operation. however unit rate to be quoted by the tendered for single operation only. | | 2000 | Sqm |
|---|
| 39 | 39 | S&F for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed. | | 20 | Each |
|---|