Public Administrative Department Government Departments Closing in 0 days TDR #28076256

Rate Contract For Pre-Fabricated Huts Pre-Fabricated Huts

Issued by Government Departments · Kashmir, Jammu And Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
09 Jun 2021
0 days left
EMD
5000
Bank guarantee accepted
Document Fee
25
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kashmir → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Rate Contract For Pre-Fabricated Huts Pre-Fabricated Huts-1 Pre-Fabricated Classroom Of Size 30’X40’ Made Up Of Steel Structure And Puf Panels In Wall As Per Drawing Attached And Technical Specifications Given Below. The Main And Partition Walls Will Be Made Up Of 60Mm Thick Puff Insulated Panels. The False Ceiling Will Be Provided With Puff Insulated Panels As Specified Below. Roof Covering Will Be Provided With 0.63 Mm Thick Colour Coated Steel Sheets.Design Parameters. ( A ) Seismic Zone - Zone V ( B ) Snow Load - 1.0 M Standing On Roof ( C ) Wind Speed - 55 M / S ( As Per Is-875 ) ( D ) Temperature - ( - ) 40 To ( + ) 50 C ( E ) Roof Slope - 1:2 2 The Steel Structure For The Shelters Built Up In Truss Purlin, Rafter, Column Made Up Of Isi Mark As Per Isi As Per Is-4923-1968 With Manufacturers Test Certificate For Raw Material And Structural Properties 3 A ) Coulumn:-The Main Columns ( 12No’S ) Will Be Made Out Of Rhs Section Of Size 122X61x3.60 Mm Conforming To Is 4923:1997. Ms Base Plate Of Size 250X250x8 Mm And Top Plate Of Size 200X150x8 Mm Will Be Welded To The Columns, All Top And Base Plates Will Be Pre-Drilled With 4 Nos 18 Mm Dia Holes. Base Plates Will Be Provided With 4 Nos 16 Mm Dia 450 Mm Long Holding Down Bolts Each, While Top Plates Will Be Provided With 4 Nos 16 Mm Dia Normal Bolts 4 B ) Rafter Made Up Of Rhs Section Of Size 96X48x4mm Thick With Ms Plate Of Size 200X150x6 Mm Thick Welded To Both Ends Of Rafter. Ms Plates Will Be Provided With 04 Nos Holes Of 18 Mm Dia To Join With Principal Rafter Plate ( C ) Truss The Principal Rafter And The Bottom Chord Will Be Fabricated Out Of Rh Steel Sections Of Size 96X48x4 Mm. All Other Structure Members Will Be Fabricated Out Of Rh Steel Sections Of Size 66X33x2.90Mm ( 4.07 Kg / Rm ) ( D ) Purlin The Purlins ( 10Nos ) Will Be Fabricated Out Of Rh Steel Sections Of Size 96X48x4mm With 6 Mm Thick Cleats Welded At Both The Ends 5 Sunshade Suitable Sunshades Made Out Of 0.63 Mm Thick Colour Coated Steel Sheets Fixed With Angle Iron Frame Of Isa 40X40x5mm ( 3.0Kg / Rm ) Will Be Provided To All External Windows And Doors. The Minimum Projection For The Sunshades Will Be 450 Mm For Window And 600Mm For Doors And 300 Mm Wider Than The Width Of The Opening. 6 Roof: 7 A. The Roof Will Be Provided With 0.63Mm Thick Colour Coated Steel Profile Sheets. Sheets Covering Will Be Fixed With Using Hot Dip Zinc Coated Self Drilling Hexagonal Washer Head Fasteners. The Sheets Shall Be Laid With Minimum End And Side Lap Of 150Mm. Ridge Shall Be Covered By 0.63 Mm Thick Colour Coated Steel Sheet. 8 B. Roof Projection. The Roof Will Have Minimum Projection 450 Mm All Around. Purlins Will Also Be Extended In The Roof At The Eaves 9 Wall Panel: ( A ) The Walls Will Be Made Up Of 60 Mm Thick Wall Panels. The Panels Will Be Made Of 0.50 Mm Thick Hot Dipped Galvanized Steel Sheets On Both Sides With 60 Mm Thick Layer Of Rigid Cfc Free Close Cell Polyurethane Foam ( Density 40 Kg +- 2Kg / Cum ) Insulation. The Wall Panels Will Be Provided With Tongue And Groove Joint And Will Be New And Shall Comply With Relevant Bureau Of India Standard Specification. Base And Top Channel Of Size 30 X 65 X 1.25 Mm Thick Will Be Provided For Fixing Of Wall Panels.The Puf Insulation Material In The Panel Will Have Fire Retarding And Self Extinguishing Properties 10 Ceiling: P / F Of ( Acoustics Ceiling ) Gip Board Fiber Square Pipe With 24Mm Grid Section For Ceiling Of Size 595X595x15mm Thick Is To Be Installed On Frame Work Of Acoustics Sktel ( Concealed Grid System To Be Used ) Which Will Comprise Of Nrc 1Base Panel With Humidity Resistance Of 90% Rh & Light Reflectance Up To 85% With Lead Points Green Performance Certified Fiber 15Mm For Ceiling Tile Rating For Flame Test With Complete Framework Of Skillet As Per Installation With Cove Design All Complete Job 11 ( C ) Openings: Doors: Three Numbers Aluminium Doors Of Size 1100X2100mm Shall Be Provided With Each Shelter As Per Drawing Windows: Six Numbers Windows Of Size 1175 X 1175 Mm Aluminium Anodized Of Extrusions Powder Colour Coated Aluminium Section Three Tracks With Three Sliding Shutters 12 Civil Work: 13 Earth Work In Excavation In All Kinds Of Soil By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30Cm In Depth 1.5 M In Width As Well As 10 Sqm On Plan ) Including Disposal Of Excavated Earth, Lead Up To 14 Supplying / Filling Dry Stone Soling Tightly Hand Packed Under Foundation & Under Floors Including All Leads, Lifts And All Carriages Upto Site Of Work Complete 15 P / L Of Cement Concrete 1:4:8 Mix Using 40Mm N / Size Agg. In Foundation / Plinth Excluding Cost Of Shuttering Complete Job 16 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For: Foundation, Footing , Bases For Columns 17 P / L Cement Concerted Flooring In 1:2:4 Mix With Nominal Size 20Mm Aggregate. With Proper Curing And All Carriages Complete Job 18 Supply And Filling Of Nallahmuckh 19 15Mm Thick Cement Plaster In Cement Mortar 1:4 Mix 20 P / L Of Vitrified Floor Tiles Of Size 60X60 Cm With Water Absorption Less Than 0.08% &Confirming To Is:15622 Of Approved Make &Colour Laid 0N 20Mm Thick Cement Motor Including Grouting The Joints With White Cement & Matching Pigment Complete Job ( 60X60cm ) Kajaria, Somany Or Equivalent 21 Construction Of Soakage / Septic Tank With All Fittings Complete Job 22 P / F Electrification Including Cost Of Wire, Conduit, Mcb, All Complete Job 23 Heating Point 24 Light Point

BOQ

Description: Rate Contract for Pre-Fab HUTS
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Pre-Fabricated Classroom of size 30’x40’ made up of steel structure and PUF panels in wall as per Drawing attached and technical specifications given below. The main and partition walls will be made up of 60mm thick Puff insulated panels. The false ceiling will be provided with Puff insulated panels as specified below. Roof covering will be provided with 0.63 mm thick colour coated steel sheets.Design parameters.(a) Seismic zone - zone V (b) Snow load - 1.0 m standing on roof (c) Wind speed - 55 m/s (as per IS-875) (d) Temperature - (-) 40 to (+) 50 c (e) Roof slope - 1:2
22The steel structure for the shelters built up in Truss Purlin, Rafter, Column made up of ISI mark as per ISI as per IS-4923-1968 with manufacturers test certificate for raw material and structural properties
32.01a) COULUMN:-The main columns (12No’s) will be made out of RHS section of size 122x61x3.60 mm conforming to IS 4923:1997. Ms Base plate of size 250x250x8 mm and top plate of size 200x150x8 mm will be welded to the columns, All top and base plates will be pre-drilled with 4 Nos 18 mm dia holes. Base plates will be provided with 4 Nos 16 mm dia 450 mm long holding down bolts each, while top plates will be provided with 4 Nos 16 mm dia normal bolts1Kg
42.02b) RAFTER Made up of RHS section of size 96x48x4mm thick with MS plate of size 200x150x6 mm thick welded to both ends of rafter. MS plates will be provided with 04 nos holes of 18 mm dia to join with principal rafter plate (c) TRUSS The principal rafter and the bottom chord will be fabricated out of RH steel sections of size 96x48x4 mm. All other structure members will be fabricated out of RH steel sections of size 66x33x2.90mm (4.07 kg/Rm) (d) PURLIN The purlins (10nos) will be fabricated out of RH steel sections of size 96x48x4mm with 6 mm thick cleats welded at both the ends1Kg
52.03Sunshade Suitable sunshades made out of 0.63 mm thick colour coated steel sheets fixed with angle iron frame of ISA 40X40X5MM (3.0KG/Rm) will be provided to all external windows and doors. The minimum projection for the sunshades will be 450 mm for window and 600mm for doors and 300 mm wider than the width of the opening.1Sqm
63Roof:
73.01a. The roof will be provided with 0.63mm thick colour coated steel profile sheets. Sheets covering will be fixed with using hot dip zinc coated self drilling hexagonal washer head fasteners. The sheets shall be laid with minimum end and side lap of 150mm. Ridge shall be covered by 0.63 mm thick colour coated steel sheet.1Sqm
83.02b. Roof Projection. The roof will have minimum projection 450 mm all around. Purlins will also be extended in the roof at the eaves1Rm
94WALL PANEL: (a) The walls will be made up of 60 mm thick wall panels. The panels will be made of 0.50 mm thick hot dipped galvanized steel sheets on both sides with 60 mm thick layer of rigid CFC free close cell polyurethane foam (Density 40 Kg +- 2Kg/Cum) insulation. The wall panels will be provided with tongue and groove joint and will be new and shall comply with relevant Bureau of India Standard specification. Base and Top channel of size 30 x 65 x 1.25 mm thick will be provided for fixing of wall panels.The PUF insulation material in the panel will have fire retarding and self extinguishing properties1Sqm
104.01CEILING: P/F of (Acoustics ceiling) GIP board fiber square pipe with 24mm grid section for ceiling of size 595x595x15mm thick is to be installed on frame work of Acoustics sktel (concealed grid system to be used ) which will comprise of NRC 1base panel with humidity resistance of 90% RH & light reflectance up to 85% with lead points green performance certified fiber 15mm for ceiling tile rating for flame test with complete framework of skillet as per installation with cove design all complete job1Sqm
114.02(c) Openings: Doors: Three Numbers aluminium doors of size 1100x2100mm shall be provided with each shelter as per drawing Windows: Six numbers windows of size 1175 x 1175 mm aluminium anodized of extrusions powder colour coated aluminium section three tracks with three sliding shutters1Sqm
125CIVIL WORK:
135.01Earth work in excavation in all Kinds of soil by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to1Cum
145.02Supplying /filling dry stone soling tightly hand packed under foundation & under floors including all leads, lifts and all carriages upto site of work complete1Cum
155.03P/L of cement concrete 1:4:8 mix using 40mm N/size agg. In foundation /plinth excluding cost of shuttering complete job1Cum
165.04Centering and shuttering including strutting ,propping etc. and removal of form work for: foundation, footing ,bases for columns1Sqm
175.05P/L cement concerted flooring in 1:2:4 mix with nominal size 20mm aggregate. with proper curing and all carriages complete job1Sqm
185.06Supply and filling of Nallahmuckh1Cum
195.0715mm thick cement Plaster in cement mortar 1:4 mix1Sqm
205.08P/L of vitrified floor tiles of size 60x60 cm with water absorption less than 0.08% &confirming to IS:15622 of approved make &colour laid 0n 20mm thick cement motor including grouting the joints with white cement & matching pigment complete job(60x60cm) Kajaria, Somany or equivalent1Sqm
216CONSTRUCTION OF SOAKAGE/SEPTIC TANK with all fittings Complete Job1Cum
227P/F Electrification including cost of wire, Conduit, MCB, all complete job
237.01Heating Point1Point
247.02Light Point1Point

AI Tender Summary

OUR REF NO 28076256
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 09-06-2021
Authority
Authority Name Jammu And Kashmir Small Scale Industries Development Corporation Limited
Work Description Rate Contract For Pre-Fabricated Huts Pre-Fabricated Huts-1 Pre-Fabricated Classroom Of Size 30’X40’ Made Up Of Steel Structure And Puf Panels In Wall As Per Drawing Attached And Technical Specifications Given Below. The Main And Partition Walls Will Be Made Up Of 60Mm Thick Puff Insulated Panels. The False Ceiling Will Be Provided With Puff Insulated Panels As Specified Below. Roof Covering Will Be Provided With 0.63 Mm Thick Colour Coated Steel Sheets.Design Parameters. ( A ) Seismic Zone - Zone V ( B ) Snow Load - 1.0 M Standing On Roof ( C ) Wind Speed - 55 M / S ( As Per Is-875 ) ( D ) Temperature - ( - ) 40 To ( + ) 50 C ( E ) Roof Slope - 1:2 2 The Steel Structure For The Shelters Built Up In Truss Purlin, Rafter, Column Made Up Of Isi Mark As Per Isi As Per Is-4923-1968 With Manufacturers Test Certificate For Raw Material And Structural Properties 3 A ) Coulumn:-The Main Columns ( 12No’S ) Will Be Made Out Of Rhs Section Of Size 122X61x3.60 Mm Conforming To Is 4923:1997. Ms Base Plate Of Size 250X250x8 Mm And Top Plate Of Size 200X150x8 Mm Will Be Welded To The Columns, All Top And Base Plates Will Be Pre-Drilled With 4 Nos 18 Mm Dia Holes. Base Plates Will Be Provided With 4 Nos 16 Mm Dia 450 Mm Long Holding Down Bolts Each, While Top Plates Will Be Provided With 4 Nos 16 Mm Dia Normal Bolts 4 B ) Rafter Made Up Of Rhs Section Of Size 96X48x4mm Thick With Ms Plate Of Size 200X150x6 Mm Thick Welded To Both Ends Of Rafter. Ms Plates Will Be Provided With 04 Nos Holes Of 18 Mm Dia To Join With Principal Rafter Plate ( C ) Truss The Principal Rafter And The Bottom Chord Will Be Fabricated Out Of Rh Steel Sections Of Size 96X48x4 Mm. All Other Structure Members Will Be Fabricated Out Of Rh Steel Sections Of Size 66X33x2.90Mm ( 4.07 Kg / Rm ) ( D ) Purlin The Purlins ( 10Nos ) Will Be Fabricated Out Of Rh Steel Sections Of Size 96X48x4mm With 6 Mm Thick Cleats Welded At Both The Ends 5 Sunshade Suitable Sunshades Made Out Of 0.63 Mm Thick Colour Coated Steel Sheets Fixed With Angle Iron Frame Of Isa 40X40x5mm ( 3.0Kg / Rm ) Will Be Provided To All External Windows And Doors. The Minimum Projection For The Sunshades Will Be 450 Mm For Window And 600Mm For Doors And 300 Mm Wider Than The Width Of The Opening. 6 Roof: 7 A. The Roof Will Be Provided With 0.63Mm Thick Colour Coated Steel Profile Sheets. Sheets Covering Will Be Fixed With Using Hot Dip Zinc Coated Self Drilling Hexagonal Washer Head Fasteners. The Sheets Shall Be Laid With Minimum End And Side Lap Of 150Mm. Ridge Shall Be Covered By 0.63 Mm Thick Colour Coated Steel Sheet. 8 B. Roof Projection. The Roof Will Have Minimum Projection 450 Mm All Around. Purlins Will Also Be Extended In The Roof At The Eaves 9 Wall Panel: ( A ) The Walls Will Be Made Up Of 60 Mm Thick Wall Panels. The Panels Will Be Made Of 0.50 Mm Thick Hot Dipped Galvanized Steel Sheets On Both Sides With 60 Mm Thick Layer Of Rigid Cfc Free Close Cell Polyurethane Foam ( Density 40 Kg +- 2Kg / Cum ) Insulation. The Wall Panels Will Be Provided With Tongue And Groove Joint And Will Be New And Shall Comply With Relevant Bureau Of India Standard Specification. Base And Top Channel Of Size 30 X 65 X 1.25 Mm Thick Will Be Provided For Fixing Of Wall Panels.The Puf Insulation Material In The Panel Will Have Fire Retarding And Self Extinguishing Properties 10 Ceiling: P / F Of ( Acoustics Ceiling ) Gip Board Fiber Square Pipe With 24Mm Grid Section For Ceiling Of Size 595X595x15mm Thick Is To Be Installed On Frame Work Of Acoustics Sktel ( Concealed Grid System To Be Used ) Which Will Comprise Of Nrc 1Base Panel With Humidity Resistance Of 90% Rh & Light Reflectance Up To 85% With Lead Points Green Performance Certified Fiber 15Mm For Ceiling Tile Rating For Flame Test With Complete Framework Of Skillet As Per Installation With Cove Design All Complete Job 11 ( C ) Openings: Doors: Three Numbers Aluminium Doors Of Size 1100X2100mm Shall Be Provided With Each Shelter As Per Drawing Windows: Six Numbers Windows Of Size 1175 X 1175 Mm Aluminium Anodized Of Extrusions Powder Colour Coated Aluminium Section Three Tracks With Three Sliding Shutters 12 Civil Work: 13 Earth Work In Excavation In All Kinds Of Soil By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30Cm In Depth 1.5 M In Width As Well As 10 Sqm On Plan ) Including Disposal Of Excavated Earth, Lead Up To 14 Supplying / Filling Dry Stone Soling Tightly Hand Packed Under Foundation & Under Floors Including All Leads, Lifts And All Carriages Upto Site Of Work Complete 15 P / L Of Cement Concrete 1:4:8 Mix Using 40Mm N / Size Agg. In Foundation / Plinth Excluding Cost Of Shuttering Complete Job 16 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For: Foundation, Footing , Bases For Columns 17 P / L Cement Concerted Flooring In 1:2:4 Mix With Nominal Size 20Mm Aggregate. With Proper Curing And All Carriages Complete Job 18 Supply And Filling Of Nallahmuckh 19 15Mm Thick Cement Plaster In Cement Mortar 1:4 Mix 20 P / L Of Vitrified Floor Tiles Of Size 60X60 Cm With Water Absorption Less Than 0.08% &Confirming To Is:15622 Of Approved Make &Colour Laid 0N 20Mm Thick Cement Motor Including Grouting The Joints With White Cement & Matching Pigment Complete Job ( 60X60cm ) Kajaria, Somany Or Equivalent 21 Construction Of Soakage / Septic Tank With All Fittings Complete Job 22 P / F Electrification Including Cost Of Wire, Conduit, Mcb, All Complete Job 23 Heating Point 24 Light Point
Basic Detail
Tender No 06aa-SICOP (GMM) of 2021 Dated 04.06.2021
Bidding Type Tender
Location
City Kashmir
State Jammu And Kashmir
Key Dates
Publish Date 04 Jun 2021
Submission Date 09 Jun 2021
Open Date 10 Jun 2021
Finance
Tender Value Ref. Documents
Tender Fee 25
EMD 5000
Exemption Not Available
Document List
Tendernotice_1.pdf
BOQ_247644.xls
06aaSBDPreFabHuts.pdf
956B25CD-15A5-48E5-81E7-C8809826245A.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 04, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 09, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 10, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

xls

BOQ_247644.xls

pdf

06aaSBDPreFabHuts.pdf

html

956B25CD-15A5-48E5-81E7-C8809826245A.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender