External Electrification And Sub Station Works At Food Craft Institute Almora-2Nd Call, Almora-Uttarakhand

Finance Department has published External Electrification And Sub Station Works At Food Craft Institute Almora-2Nd Call. Submission Date for this Tender is 14-06-2021. Electrification Work Tenders in Almora Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

28028476
External Electrification And Sub Station Works At Food Craft Institute Almora-2Nd Call
Open Tender
Indian
Uttarakhand
Almora
14-06-2021

Tender Details

External Electrification And Sub Station Works At Food Craft Institute Almora-2Nd Call

Key Value

Document Fees
INR 5900 /-
EMD
INR 83000.0 /-
Tender Value
INR 41.70 Lakhs /-

BOQ Items

Name of Work:CONSTRUCTION OF PROPOSED SUB STATION EQUIPMENTS AT FOOD CRAFT INSTITUTE ALMORA-2nd Call
Sl. No. Item Description Item Code / Make Quantity Units
1 1 TWO POLE STRUCTURE\nSupplying, installing, structural steel tubular pole conforming to IS-2713, 410 SP-51, 164 Kg weight with base plate of 300 mm x 300 mm x 6 mm for erecting 11 KV two pole structure comprising of 11 Mtr. pole, i/c welding, cutting, revetting, bolting and painting the entire structures with red oxide primer and two coats of synthetic enamel paint and necessary foundations including excavation and earth work for the steel structure with PCC 1:2:4 with following accessories. BI01010001010000000000000515BI0100001127
2 1.01 Supplying, installing 11 KV 9 KA discharge current single pole lightning arrestor with insulated base and necessary hardware. - 3 Nos. BI01010001010000000000000515BI0100001128
3 1.02 Supplying & installing 11 KV single pole strain insulators complete with all necessary hardware for termination. - 3 Nos. BI01010001010000000000000515BI0100001129
4 1.03 Supplying & installing 11 KV 3 phase, 200 Amp. Vertical type gang operated switch with hot dip galvanised channels post type, insulator, tinned copper contacts, arcing horns, GI pipe gang operating handle, limit switch etc. (wiring with 4 x 2.5 sq.mm PVC insulated copper wire upto HT breaker laid in GI pipe of 40mm dia) locking arrangements etc. complete in all respects. - 1 Set. BI01010001010000000000000515BI0100001130
5 1.04 Supplying & installing 11 KV post type insulators for jumper supports. - 3 Nos. BI01010001010000000000000515BI0100001131
6 1.05 11 KV, 3 phase 200 Amp dropout fuse unit with 60 Amp fuses. Hot dip galvanished channel, post type insulator, tinned copper contacts bakelite fuse, carriers etc. complete in all respects. - 1 Set. BI01010001010000000000000515BI0100001132
7 1.06 Supplying & installing of "DOG" 6 /. 186 Al. Plus 7 / 0.062 Steel ACSR overhead conductor - 10 Mtrs. BI01010001010000000000000515BI0100001133
8 1.07 Cross arms of shape and size as shown on drawing and made out of M.S. channels 100mmx50mm with flats and fixed to poles with M.S. clamps, GI bolts, nuts and washers and all hardware, jumpers & thimbles etc. of required size. BI01010001010000000000000515BI0100001134
9 1.08 Anti Climbing devices on each pole made out of 2 mm barbed wire coiled alongwith pole. BI01010001010000000000000515BI0100001135
10 1.09 Danger Notice Boards with Skull & Bones in red colour made out of 14 SWG sheet in Hindi & English with voltage indicated. BI01010001010000000000000515BI0100001136
11 1.1 Supplying & installing 150 mm dia GI pipe - 10 Mtr. BI01010001010000000000000515BI0100001137
12 1.11 Earthing & GI Strips. BI01010001010000000000000515BI0100001138
13 1.12 Stay Assembly. BI01010001010000000000000515BI0100001139 1 Set
14 2 Supplying, installation, testing & commissioning of single panel with VCB totally enclosed, indoor sheet steel clad floor mounting, vermin proof, vertical isolation, horizontal drawout, extensible type air insulated metal clad switchgear having motorised mechanism SPMX, complete with circuits detailed as below The switchboard would be complete with necessary busbars and integral earthing facility through bus bar for the entire switchboard, small wiring labels, cable eyes, cable box to receive XLPE cables suitable for operation on 11 KV, three phase, 50 cycle, earthed system with a rupturing capacity of 350 MVA at 11 KV. BI01010001010000000000000515BI0100001140
15 2.01 Supplying, installation, testing & commissioning of single panel with VCB totally enclosed, indoor sheet steel clad floor mounting, vermin proof, vertical isolation, horizontal drawout, extensible type air insulated metal clad switchgear having motorised mechanism SPMX, complete with circuits detailed as below The switchboard would be complete with necessary busbars and integral earthing facility through bus bar for the entire switchboard, small wiring labels, cable eyes, cable box to receive XLPE cables suitable for operation on 11 KV, three phase, 50 cycle, earthed system with a rupturing capacity of 350 MVA at 11 KV. BI01010001010000000000000515BI0100001141
16 2.02 1) One. Incoming panel equipped with air insulated Metal clad 630 Amps. Housing. BI01010001010000000000000515BI0100001142
17 2.03 2) A set of three phase PVC insulated 630 Amp busbars. BI01010001010000000000000515BI0100001143
18 2.04 3) One triple pole draw out truck mounted 350 MVA 630 amps, Vacuum Circuit Breaker fitted with all necessary vacuum interrupters. BI01010001010000000000000515BI0100001144
19 2.05 4) One trip free, motor charged, spring released closing mechanism fitted with shunt trip suitable for 24 V DC operation complete with necessary auxiliary switches, emergency hand trip device and mechanical ON and OFF indicators. BI01010001010000000000000515BI0100001145
20 2.06 5) 3 Nos 100/50/5A ratio, 15 VA, class 1.0 resin cast current transformer for metering purpose and 15 VA, class 5P10 resin cast current transformer for protection purposes. BI01010001010000000000000515BI0100001146
21 2.07 6) One three phase horizontal draw out type resin cast line type potential transformer of 11KV/110 V, 100 VA burden per phase class 1.0 accuracy connected star/star on HV & LV sides with HV and LV fuses, isolating plugs, for HV side and LV connection. BI01010001010000000000000515BI0100001147
22 2.08 7) One strip heater to prevent absorption of moisture. BI01010001010000000000000515BI0100001148
23 2.09 8) IDMT relay having 2 over current & 1 no. Earth fault relay BI01010001010000000000000515BI0100001149
24 2.1 INSTRUMENT PANEL BI01010001010000000000000515BI0100001150
25 2.11 1) One 144 sq.mm, scaled 0-15000V, flush type, digital voltmeter with 3 way and OFF selector switch. BI01010001010000000000000515BI0100001151
26 2.12 2) One 144 sq.mm, scaled 0-200 Amps, flush type, digital ammeter with 3 way and OFF selector switch. BI01010001010000000000000515BI0100001152
27 2.13 3) One 144 sq.mm digital PF meter. BI01010001010000000000000515BI0100001153
28 2.14 4) One no. Electronic Trivector Meter. BI01010001010000000000000515BI0100001154
29 2.15 5) One triple pole very inverse definite mean time over-current and earth fault relay two outer elements connected for over current protection and the middle element for earth fault protection with over current setting of 50-200%,and earth fault setting 10 to 40% and short circuit setting of 200-800%. BI01010001010000000000000515BI0100001155
30 2.16 6) One no. trip circuit supervision relay. BI01010001010000000000000515BI0100001156
31 2.17 7) One no. Master trip relay. BI01010001010000000000000515BI0100001157
32 2.18 8) Annunciation circuit for fault tripping of HT panels with 8 Window annunciation with windows. BI01010001010000000000000515BI0100001158
33 2.19 9) One set of Red/Green/Indication lamps for check and open protection. BI01010001010000000000000515BI0100001159
34 2.2 10) One Amber indicating lamp for trip circuit healthy BI01010001010000000000000515BI0100001160
35 2.21 11) One set of white phase indication lamps for phase. BI01010001010000000000000515BI0100001161
36 2.22 OUTGOING BI01010001010000000000000515BI0100001162
37 2.23 1) Outgoing Panel equipped with air insulated Metal clad 630 Amps. Housing BI01010001010000000000000515BI0100001163
38 2.24 2) A set of three phase PVC insulated 630 Amp busbars. BI01010001010000000000000515BI0100001164
39 2.25 3) One triple pole draw out truck mounted 350 MVA 630 amps, Vacuum Circuit Breaker fitted with all necessary vacuum interrupters. BI01010001010000000000000515BI0100001165
40 2.26 4) One trip free, motor charged, spring released closing mechanism fitted with shunt trip suitable for 24 V DC operation complete with necessary auxiliary switches, emergency hand trip device and mechanical On and OFF indicators. BI01010001010000000000000515BI0100001166
41 2.27 5) 3 Nos 50/30/5 A ratio, 15 VA, class 1.0 Resin cast current transformer for metering purpose and 15 VA class 5P10 resin cast current transformer for protection purposes. BI01010001010000000000000515BI0100001167
42 2.28 6) One strip heater to prevent absorption of moisture. BI01010001010000000000000515BI0100001168
43 2.29 7) One 144 sq.mm, scaled 0-30Amps, flush type, digital ammeter with 3 way and OFF selector switch. BI01010001010000000000000515BI0100001169
44 2.3 8) One no. trip circuit supervision relay. BI01010001010000000000000515BI0100001170
45 2.31 9) One no. Master trip relay BI01010001010000000000000515BI0100001171
46 2.32 10) One set of Red/Green/Indication lamps for check and open protection. BI01010001010000000000000515BI0100001172
47 2.33 11) One amber indicating lamp for trip circuit healthy. BI01010001010000000000000515BI0100001173
48 2.34 12) One set of white phase indication lamps for phase. BI01010001010000000000000515BI0100001174
49 2.35 13) Suitable cable boxes with double compression brass glands suitable to receive 3 Core 11KV XLPE cable. BI01010001010000000000000515BI0100001175
50 2.36 14) Annunciation circuit for fault tripping of HT panels with 8 Window annunciation with windows. BI01010001010000000000000515BI0100001176
51 2.37 15) IDMT relay having 2 over current & 1 no. Earth fault relay BI01010001010000000000000515BI0100001177 1 Set
52 3 Supplying, installing, testing & commissioning of O.L.T.C. 400 KVA Dry Type Transformer with copper winding having 400 KVA rating 11 KV / 433 V, 3 Phase, 50 Hz Vector Group Dyn-11, having cable end box on HV side suitable for 11 KV XLPE cable & on 433 Volt side suitable for XLPE cable.The Transformer shall have on load tap changing links on HV side, for +7.5% to -7.5% in steps of 2.5% with locking arrangement. It shall also have Thermistor Type Sensor for high temperature Alarm & Trip contacts, Earthing Terminal, Lifting hooks, base channels skid type suitable for mounting on floor and plinth. The enclosure of transformer shall be sheet steel enclosure type IP33 for indoor installation complete as required. BI01010001010000000000000515BI0100001178 1 set
53 4 Supplying, installing, testing & commissioning of Trickle Boost Charger of 24 Volt complete with automatic trickle charger, change over complete with voltmeter, ammeter 50 Hz. AC supply & DC ammeter / voltmeter complete with 12 Nos. 2 Volt batteries, 40 AH etc. as required. BI01010001010000000000000515BI0100001179 1 Set
54 5 150 KVAR CAPACITOR PANEL BI01010001010000000000000515BI0100001180
55 5.01 Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of suitable size 4 strip Al. Busbar complete with interconnection providing Lugs, inter-earthing, painting etc. i/c providing & fixing below noted accessories: BI01010001010000000000000515BI0100001181
56 5.02 INCOMING : BI01010001010000000000000515BI0100001182
57 5.03 200 Amp 415 V FP MCCB having breaking capacity - 50 KA, with Rotary Handle operating Mechanism - 1 Nos. BI01010001010000000000000515BI0100001183
58 5.04 (0-200 A) Digital Ammeter with selector switch & 200/5 C.T.'s - 1 Set BI01010001010000000000000515BI0100001184
59 5.05 0 - 500 Volt Voltmeter with selector switch - 1 Set BI01010001010000000000000515BI0100001185
60 5.06 RYB Indication lamps with Backup fuses - 1 Set of three BI01010001010000000000000515BI0100001186
61 5.07 Power factor meter - 1 Set BI01010001010000000000000515BI0100001187
62 5.08 8 step APFC relay with aux. Contactor and timer - 1 Set BI01010001010000000000000515BI0100001188
63 5.09 OUTGOING : BI01010001010000000000000515BI0100001189
64 5.1 80 Amp 415 V TP MCCB having breaking capacity - 35 KA, with Ics=Icu=35 KA, with Rotary Handle operating Mechanism - 5 Nos. BI01010001010000000000000515BI0100001190
65 5.11 63 A TP Contactor - 5 Nos. BI01010001010000000000000515BI0100001191
66 5.12 25 KVAR Capacitor banks - 5 Sets (MPP type Normal Duty) BI01010001010000000000000515BI0100001192
67 5.13 Push button for START / STOP - 5 Set BI01010001010000000000000515BI0100001193
68 5.14 AUTO / MANUAL Selector switch - 1 No. BI01010001010000000000000515BI0100001194 1 Set
69 6 Supplying, installing, testing & commissioning of 630 amp. Ready to intall factory fabricated automatic transformer switch (ATS) to manage the automatic change over between two supply lines (one from transformer & the other from D.G. Set) along with enclosure CRCA sheet steal duly power coated after derusting, degreasing & phosphetising etc. complete with electronic control box, inverted mounting plate and 2 nos. 630 amp. MCCB's 70 KA, connection, interconnection, lungs etc. as required. BI01010001010000000000000515BI0100001195 1 Set
70 7 FEEDER PILLAR - 1 (out door cubical panel) BI01010001010000000000000515BI0100001196
71 7.01 Supply and creation of factory fabricated and wired metal clad dust and vermin proof floor mounting panel MCCB switch board complete with the following MCCB , MCB and instrument chamber etc. complete in all respects. the instrument chamber shall be separate and shall comprise of digital type ammeter. Voltmeter, selector switches for ammeter and voltmeter instrument, fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminum bus-bars as per IS:8623 insulated with heat shrink sleevings and mounted on non hygroscopic supports such as CMC/DMC supports with detachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, cable sockets, compression glands and indicating lamp on incoming etc.The switch board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm cubical type. \n.\n\n BI01010001010000000000000515BI0100001197
72 7.02 INCOMING : BI01010001010000000000000515BI0100001198
73 7.03 100 Amp 415 V FP MCCB having breaking capacity - 25 KA, with Ics=Icu=25 KA, with Rotary Handle operating Mechanism - 1 No. BI01010001010000000000000515BI0100001199
74 7.04 (0- 100A) Digital Ammeter with selector switch, 100/5A C.T.'s - 1 Set BI01010001010000000000000515BI0100001200
75 7.05 (0-500 V) Digital Voltmeter with selector switch - 1 Set BI01010001010000000000000515BI0100001201
76 7.06 Indication lamp R/Y/B with backup fuses - 1 Set of Three BI01010001010000000000000515BI0100001202
77 7.07 150A strip Al. bus bars with heat shrinkable colored PVC sleeves 1 Set BI01010001010000000000000515BI0100001203
78 7.08 OUTGOING BI01010001010000000000000515BI0100001204
79 7.09 63 Amp 415 V TP MCCB having breaking capacity - 25 KA, with Ics=Icu=25 KA, with Rotary Handle operating Mechanism - 7 No. BI01010001010000000000000515BI0100001205
80 7.1 63A FP MCCB -1 No. BI01010001010000000000000515BI0100001206
81 7.11 40A FP CONTACTOR - 1 No. BI01010001010000000000000515BI0100001207
82 7.12 40A TP Isolater -2 No. BI01010001010000000000000515BI0100001208
83 7.13 Timer for 24 hours BI01010001010000000000000515BI0100001209 1 Set
84 8 Supplying of following size of 11 KV cable circular aluminium conductor, conductor screened, XLPE insulated, insulation screened with extruded semi-conducting compound in combination with copper tape (short ckt. rating (350MVA for 1 sec). Aluminium round wire armoured and overall PVC sheathed cable conforming to IS:7098/II/85 with latest amendments complete as reqd. BI01010001010000000000000515BI0100001210
85 8.01 3 core 185 sq.mm. BI01010001010000000000000515BI0100001211 50 Mtr
86 8.02 3 core 120 sq.mm. BI01010001010000000000000515BI0100001212 25 Mtr
87 9 Supplying and making INDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. BI01010001010000000000000515BI0100001213
88 9.01 120 sq. mm BI01010001010000000000000515BI0100001214 3 Nos
89 9.02 185 sq. mm BI01010001010000000000000515BI0100001215 2 Nos
90 10 Supplying and making OUTDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor .cable of 11 KV grade as required: BI01010001010000000000000515BI0100001216
91 10.01 185 sq. mm BI01010001010000000000000515BI0100001217 1 Nos
92 11 Laying of one number PVC insulated and PVC but not exceeding 11 KV of size exceeding 120 sq. mm but not exceeding 400 sq. mm dirct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. BI01010001010000000000000515BI0100001218 25 Mtr
93 12 Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade (XLPE type) at a depth of 750mm below ground lever over a cushion of 75 mm. thick sand around and protect with burnt bricks on sides and on top. as directed by he Engineer-armouring of by he cable shall be properly connected with the earth conductor by clamps etc. BI01010001010000000000000515BI0100001219
94 12.01 3.5 x 185 sq.mm. BI01010001010000000000000515BI0100001220 50 Mtr
95 12.02 3.5 x 300 sq.mm. BI01010001010000000000000515BI0100001221 40 Mtr
96 13 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1. KV grade as required : BI01010001010000000000000515BI0100001222
97 13.01 3.5 x 185 sq.mm. BI01010001010000000000000515BI0100001223 2 Nos
98 13.02 3.5 x 300 sq.mm. BI01010001010000000000000515BI0100001224 4 Nos
99 14 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement :2 fine sand) including testing of joints etc. complete. BI01010001010000000000000515BI0100001226
100 14.01 250 mm dia. R.C.C. pipe BI01010001010000000000000515BI0100001227 30 Mtr
101 15 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick Including accessoires, & providing masonary enclosure with cover plate having locking arrangement & watering pipe etc. (but without charcoal or coke and salt) as required. BI01010001010000000000000515BI0100001228 6 Set
102 16 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick Including accessories, & providing masonary enclosure with cover plate having locking arrangement & watering pipe etc. (but without charcoal or coke and salt) as required. BI01010001010000000000000515BI0100001229 4 Set
103 17 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode, as required. BI01010001010000000000000515BI0100001230 75 Mtr.
104 18 Providing & fixing 25 mm X 5 mm G.I strip on surface or in recess for connections etc. as required. BI01010001010000000000000515BI0100001231 80 Mtr.
105 19 Providing and fixing M.V danger notice plate of 200 mm x 150 mm, made mild steel, atleast 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.st 2mm thick & vitreous enamelled white on both sides & with inscription in single red colour on front side as required. BI01010001010000000000000515BI0100001232 4 Set
106 20 DANPLHV P/F H.V. danger notice plate: each\nProviding and fixing H.T danger notice plate of 250 x 200 mm, made mild steel, atleast 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. BI01010001010000000000000515BI0100001233 2 Set
107 21 Supplying and making cable route marker with cement concrete 1.2.4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. BI01010001010000000000000515BI0100001234 40 set
108 22 Providing, installing, testing and commissioning of Diesel Generating set having prime power rating of 125 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system and consisting of the following: BI01010001010000000000000515BI0100001235
109 22.01 Diesel Engine BI01010001010000000000000515BI0100001236
110 22.02 Diesel Engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at site condition and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour in any 12 hours duration. The engine will be fitted complete with all the reqd. acc. including the following accessories: BI01010001010000000000000515BI0100001237
111 22.03 Flywheel to suit flexible coupling BI01010001010000000000000515BI0100001238
112 22.04 Flexible coupling BI01010001010000000000000515BI0100001239
113 22.05 Exhaust gas turbo charger BI01010001010000000000000515BI0100001240
114 22.06 Automatic safety control in case of high water temperature BI01010001010000000000000515BI0100001241
115 22.07 Automatic safety control in case of low lubrication oil pressure BI01010001010000000000000515BI0100001242
116 22.08 Automatic over speed trip protection BI01010001010000000000000515BI0100001243
117 22.09 Lubrication oil pump BI01010001010000000000000515BI0100001244
118 22.1 Lubrication oil filter BI01010001010000000000000515BI0100001245
119 22.11 Lubrication oil pan BI01010001010000000000000515BI0100001246
120 22.12 Lube oil By-Pass filter BI01010001010000000000000515BI0100001247
121 22.13 Fuel pump BI01010001010000000000000515BI0100001248
122 22.14 Fuel filter BI01010001010000000000000515BI0100001249
123 22.15 Hoses for fuel tank BI01010001010000000000000515BI0100001250
124 22.16 Air intake manifold BI01010001010000000000000515BI0100001251
125 22.17 Air cleaner dry type BI01010001010000000000000515BI0100001252
126 22.18 Electronic Governor BI01010001010000000000000515BI0100001253
127 22.19 Self Starter BI01010001010000000000000515BI0100001254
128 22.2 Alternator for battery charging BI01010001010000000000000515BI0100001255
129 22.21 Flexible pipe for silencer BI01010001010000000000000515BI0100001256
130 22.22 Engine mounted Instrument Panel fitted with and having digital display for following: BI01010001010000000000000515BI0100001257
131 22.23 Start-stop switch with key BI01010001010000000000000515BI0100001258
132 22.24 Water temperature indication BI01010001010000000000000515BI0100001259
133 22.25 Lubrication oil pressure indication BI01010001010000000000000515BI0100001260
134 22.26 Lubrication oil temperature indication BI01010001010000000000000515BI0100001261
135 22.27 Battery charging indication BI01010001010000000000000515BI0100001262
136 22.28 RPM indication BI01010001010000000000000515BI0100001263
137 22.29 Over speed indication BI01010001010000000000000515BI0100001264
138 22.3 Low lub. Oil trip indication BI01010001010000000000000515BI0100001265
139 22.31 Engine Hours indication BI01010001010000000000000515BI0100001266
140 22.32 Alternator: BI01010001010000000000000515BI0100001267
141 22.33 Synchronous alternator rated at 125 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at site condition. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722 / BS 2613 suitable for tropical conditions and with class-F/H insulation. BI01010001010000000000000515BI0100001268
142 22.34 Base Frame & Foundation: BI01010001010000000000000515BI0100001269
143 22.35 Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. BI01010001010000000000000515BI0100001270
144 22.36 Fuel Tank: BI01010001010000000000000515BI0100001271
145 22.37 Daily service fuel tank of 990 liters capacity fabricated out of 3mm thick MS sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required. BI01010001010000000000000515BI0100001272
146 22.38 Exhaust System: BI01010001010000000000000515BI0100001273
147 22.39 Dry exhaust manifold with hospital exhaust silencer and catalytic converter. BI01010001010000000000000515BI0100001274
148 22.4 Starting System: BI01010001010000000000000515BI0100001275
149 22.41 12V / 24 V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation. Complete with suitable nos. of batteries. BI01010001010000000000000515BI0100001276
150 22.42 Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. BI01010001010000000000000515BI0100001277 1 Set