Gorakhpur Municipal Corporation has published Request For Proposal For Selection Of Master System Integrator ( Msi ) For Implementation Of Intelligent Traffic Management System ( Itms ) In Gorakhpur City. Submission Date for this Tender is 18-06-2021. Traffic monitoring system Tenders in Nagar Nigam Gorakhpur Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: RFP for Selection of Master System Integrator (MSI) for Implementation of Intelligent Traffic Management System (ITMS) in Gorakhpur City | |||||
---|---|---|---|---|---|
Sl. No. | BOM Line Item | Item Code / Make | Indicative Quantity | Units | |
1 | 1 | Adaptive Traffic Control System | BI01010001010000000000000515BI0100001112 | ||
2 | 1.01 | ATCS Controller with cabinet and other accessories | BI01010001010000000000000515BI0100001113 | 21 | Number |
3 | 1.02 | Vehicle Detector | BI01010001010000000000000515BI0100001114 | 76 | Number |
4 | 1.03 | Traffic Signal Aspects -Red | BI01010001010000000000000515BI0100001115 | 228 | Number |
5 | 1.04 | Traffic Signal Aspects – Amber | BI01010001010000000000000515BI0100001116 | 228 | Number |
6 | 1.05 | Traffic Signal Aspects -Green Arrow | BI01010001010000000000000515BI0100001117 | 608 | Number |
7 | 1.06 | Vehicle Countdown Timer | BI01010001010000000000000515BI0100001118 | 76 | Number |
8 | 1.07 | Pedestrian Countdown Timer | BI01010001010000000000000515BI0100001119 | 152 | Number |
9 | 1.08 | Pedestrian Walk Man | BI01010001010000000000000515BI0100001120 | 152 | Number |
10 | 1.09 | Pedestrian Stop Man | BI01010001010000000000000515BI0100001121 | 152 | Number |
11 | 1.1 | Galvanized Cantilever Poles with Foundation | BI01010001010000000000000515BI0100001122 | 76 | Number |
12 | 1.11 | Galvanized Standard Poles with Foundation | BI01010001010000000000000515BI0100001123 | 152 | Number |
13 | 1.12 | Disabled Friendly Audio Tactile Device | BI01010001010000000000000515BI0100001120 | 152 | Number |
14 | 1.13 | Pedestrian Push Button | BI01010001010000000000000515BI0100001121 | 152 | Number |
15 | 1.14 | Civil Works (Complete Cabling, Trenchless Ducting, Lightning Arrester, Junction Box, Installation, Commissioning) per Junction | BI01010001010000000000000515BI0100001122 | 21 | Number |
16 | 1.15 | ELCB pole with Junction Box per Junction | BI01010001010000000000000515BI0100001123 | 21 | Number |
17 | 2 | ITMS Centralized DC/DR | BI01010001010000000000000515BI0100001112 | ||
18 | 2.01 | ANPR Software and License per Lane | BI01010001010000000000000515BI0100001125 | 98 | Number |
19 | 2.02 | RLVD Software License per Arm | BI01010001010000000000000515BI0100001126 | 49 | Number |
20 | 2.03 | SVD Software License per Lane | BI01010001010000000000000515BI0100001127 | 16 | Number |
21 | 2.04 | E Challan Software | BI01010001010000000000000515BI0100001128 | 1 | Lot |
22 | 2.05 | Traffic Monitoring & Management System Software | BI01010001010000000000000515BI0100001125 | 1 | Lot |
23 | 2.06 | ATCS Software | BI01010001010000000000000515BI0100001126 | 1 | Lot |
24 | 2.07 | Simulation Model (for junctions) | BI01010001010000000000000515BI0100001127 | 1 | Lot |
25 | 2.08 | Traffic Enforcement Modules (No- Helmet, Triple Riding, No Parking, Wrong Way, No Seat Belt) per lane | BI01010001010000000000000515BI0100001125 | 98 | Number |
26 | 3 | Red Light Violation Detection System | BI01010001010000000000000515BI0100001112 | ||
27 | 3.01 | Red Light Violation Detection (RLVD) sensors (one per each arm) with Internal/External IR Illuminator per Arm | BI01010001010000000000000515BI0100001125 | 49 | Number |
28 | 3.02 | ANPR Camera with Internal/External IR Illuminator per Lane | BI01010001010000000000000515BI0100001126 | 98 | Number |
29 | 3.03 | Local processing unit per Arm | BI01010001010000000000000515BI0100001127 | 49 | Number |
30 | 3.04 | Galvanized Cantilever Poles with Foundation | BI01010001010000000000000515BI0100001128 | 49 | Number |
31 | 3.05 | Civil Works (Complete Cabling, Trenchless Ducting, Lightning Arrester, Junction Box, Installation, Commissioning) per Junction | BI01010001010000000000000515BI0100001125 | 13 | Number |
32 | 4 | Speed Violation Detection System | BI01010001010000000000000515BI0100001112 | ||
33 | 4.01 | Speed Detection Sensor per Lane | BI01010001010000000000000515BI0100001125 | 16 | Number |
34 | 4.02 | ANPR Camera with Internal/External IR Illuminator per Lane | BI01010001010000000000000515BI0100001126 | 16 | Number |
35 | 4.03 | Local processing unit per Arm | BI01010001010000000000000515BI0100001127 | 8 | Number |
36 | 4.04 | Galvanized Cantilever Poles with Foundation | BI01010001010000000000000515BI0100001128 | 8 | Number |
37 | 4.05 | Ruggedized Network Switch | BI01010001010000000000000515BI0100001125 | 16 | Number |
38 | 4.06 | Civil Works (Complete Cabling, Trenchless Ducting, Lightning Arrester, Junction Box, Installation, Commissioning) per Junction | BI01010001010000000000000515BI0100001124 | 2 | Number |
39 | 5 | Operation Control Room | BI01010001010000000000000515BI0100001112 | ||
40 | 5.01 | Video wall 3x2 Matrix 55” screen with wall mount | BI01010001010000000000000515BI0100001126 | 1 | Number |
41 | 5.02 | Video wall Controller | BI01010001010000000000000515BI0100001127 | 1 | Number |
42 | 5.03 | Video wall Software | BI01010001010000000000000515BI0100001128 | 1 | Number |
43 | 5.04 | MPLS Router | BI01010001010000000000000515BI0100001125 | 2 | Number |
44 | 5.05 | 24 Port PoE Switch | BI01010001010000000000000515BI0100001125 | 2 | Set |
45 | 5.06 | PABX with integrated ACD & Server | BI01010001010000000000000515BI0100001126 | 1 | Number |
46 | 5.07 | PRI Gateway with one PRI card | BI01010001010000000000000515BI0100001127 | 1 | Number |
47 | 5.08 | Soft Phone | BI01010001010000000000000515BI0100001128 | 7 | Number |
48 | 5.09 | Desk Phone | BI01010001010000000000000515BI0100001125 | 7 | Number |
49 | 5.1 | Headset Compatible with Soft phone & Desk Phones | BI01010001010000000000000515BI0100001125 | 7 | Number |
50 | 5.11 | Workstation with 2 Monitor | BI01010001010000000000000515BI0100001126 | 5 | Number |
51 | 5.12 | 20 KVA Online UPS | BI01010001010000000000000515BI0100001127 | 2 | Number |
52 | 5.13 | 42 U Network Rack | BI01010001010000000000000515BI0100001128 | 1 | Number |
53 | 5.14 | Furniture for Contact Center Operator Desks | BI01010001010000000000000515BI0100001125 | 4 | Number |
54 | 5.15 | Operation Control Room Civil and Interior Cost | BI01010001010000000000000515BI0100001125 | 1 | Number |
55 | 5.16 | Air Conditioner (2 Ton) | BI01010001010000000000000515BI0100001126 | 2 | Number |
56 | 6 | City Wi-Fi | BI01010001010000000000000515BI0100001112 | ||
57 | 6.01 | Wireless Controller | BI01010001010000000000000515BI0100001126 | 1 | Set |
58 | 6.02 | Wireless Access Point (Outdoor) | BI01010001010000000000000515BI0100001127 | 150 | No. |
59 | 6.03 | Centralized Wi-Fi Management | BI01010001010000000000000515BI0100001128 | 1 | Set |
60 | 7 | PA System | BI01010001010000000000000515BI0100001112 | ||
61 | 7.01 | Public Address System – IP based PA with speakers, UPS, Mounting Structure, Junction Box and Power | BI01010001010000000000000515BI0100001125 | 21 | Number |
62 | 8 | Variable Message Signboard | BI01010001010000000000000515BI0100001112 | ||
63 | 8.01 | VMS board including VMS controller with complete hardware and accessories as required + Mounting structure for VMS including UPS facility as per specifications with UPS and Mounting Poles, VMS Software | BI01010001010000000000000515BI0100001125 | 10 | Number |
64 | 9 | Emergency Call Box | BI01010001010000000000000515BI0100001112 | ||
65 | 9.01 | ECB system with UPS, Mounting Structure, Junction Box and Power | BI01010001010000000000000515BI0100001125 | 21 | Number |
66 | 10 | Field Endpoint Connectivity | BI01010001010000000000000515BI0100001112 | ||
67 | 10.01 | City Network - MPLS | BI01010001010000000000000515BI0100001125 | 1 | Lot |
68 | 10.02 | Field Passive components | BI01010001010000000000000515BI0100001126 | 1 | Lot |
69 | 11 | Manpower | BI01010001010000000000000515BI0100001112 | ||
70 | 11.01 | Team Leader cum Project Manager | BI01010001010000000000000515BI0100001127 | 12 | Man month |
71 | 11.02 | Operation Control Room Expert | BI01010001010000000000000515BI0100001128 | 12 | Man month |
72 | 11.03 | ITMS Expert | BI01010001010000000000000515BI0100001125 | 12 | Man month |
73 | 11.04 | City Wi-Fi Expert | BI01010001010000000000000515BI0100001125 | 12 | Man month |
74 | 11.05 | ITMS Maintenance Engineer | BI01010001010000000000000515BI0100001126 | 12 | Man month |
75 | 11.06 | Electrician | BI01010001010000000000000515BI0100001127 | 12 | Man month |
76 | 12 | Common Field Items | BI01010001010000000000000515BI0100001112 | ||
77 | 12.01 | UPS and Battery along with IP65 Enclosure | BI01010001010000000000000515BI0100001125 | 42 | Number |
78 | 12.02 | Ruggedized Network Switch | BI01010001010000000000000515BI0100001128 | 76 | Number |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail