Repairs / Maintenance Of Cooling Appliances Including Window/ Split Acs/ Air Curtains / Voltage Stabilizers/ Refrigerators / Deep Freezers , Replacement Of Unserviceable Spares And Fixtures At Chaf Bangalore

Tender Notice

27998795
Corrigendum : Repairs / Maintenance Of Cooling Appliances Including Window/ Split Acs/ Air Curtains / Voltage Stabilizers/ Refrigerators / Deep Freezers , Replacement Of Unserviceable Spares And Fixtures At Chaf Bangalore
Indian
Karnataka
14-06-2021
21-06-2021
23-06-2021

Tender Details

Repairs / Maintenance Of Cooling Appliances Including Window/ Split Acs/ Air Curtains / Voltage Stabilizers/ Refrigerators / Deep Freezers , Replacement Of Unserviceable Spares And Fixtures At Chaf Bangalore

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Jun-2021 BOQ and Tender Corrigendum BOQ 14-06-2021
2 14-Jun-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-06-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.00 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIRS / MAINTENANCE OF COOLING APPLIANCES INCLUDING WINDOW/ SPLIT ACS/ AIR CURTAINS / VOLTAGE STABILIZERS/ REFRIGERATORS / DEEP FREEZERS , REPLACEMENT OF UNSERVICEABLE SPARES AND FIXTURES AT CHAF BANGALORE
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Servicing complete Split type AC up to 1.5/2.0/3.0 Ton capacity of any make as and when ordered including cleaning of air filters, greasing of fan/blower motors, electrical connections etc. as in preventive maintenance all as specified and as directed. Note:Replacement spares, charging of gas, etc. shall be measured and paid separately under relevant items of this Schedule, complete all as specified and directed. 255 Each Job
2 2 Pressure testing and rectifying the leakages found in the system of split type ACs capacity up to and including 3 Ton capacity including vacumizing,charging and checking the gas pressure to desire level complete for satisfactory functioning, complete all as specified and directed.\nNote:Topping up of gas will be measured and paid seperately 120 Each Job
3 3 Shifting of Air Conditioner,Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing, complete all as specified and directed.\nNote: Topping up of gas and copper tubing will be measured and paid seperately 22 Each Job
4 4 Hermatically sealed new compressor for split AC of capacity 1.5 Ton including disconnecting the electrical and refrigerant connection of defective sealed unit of split AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing, fixed as in repairs, complete all as specified and directed \nNote:- \n(a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase. 13 Each Job
5 5 All as per Srl item No 4 here in before but for 2 TR split type AC, complete all as specified and directed. 7 Each Job
6 6 All as per Srl item No 4 here in before but for 2.5 - 3 TR split type AC 3Ph 415V 50Hz, complete all as specified and directed. 2 Each Job
7 7 Condenser coil in replacement after disconnecting the refrigerant connection of defective condenser coil unit of split AC 1.5 Ton and replacing the condenser coil unit connecting the same unit with refrigerant connections, complete all as specified and directed. 12 Each Job
8 8 All as per Srl item No 7 here in before but for 2.0 TR Split type AC, complete all as specified and directed. 8 Each Job
9 9 All as per Srl item No 7 here in before but for 2.5-3.0 TR Split type AC, complete all as specified and directed. 4 Each Job
10 10 Remote assembly corded/cordless for any type and size of split type ACs, upto and including 3.0 TR, fixed as in repairs, complete all as specified and directed. 20 Each
11 11 Remote sensing unit for upto and including 2.0 TR split type Ac of existing type, fixed as in repairs, complete all as specified and directed. 18 Each
12 12 Remote sensing unit for 2.5-3.0 TR split type Ac of existing type, fixed as in repairs, complete all as specified and directed. 9 Each
13 13 Condenser Fan motor suitable for split type Air Conditioner of any make up to and including 3 TR capacity, fixed as in repairs, complete all as specified and directed. Make of fan motor: AUE/ GEC/Himsun. 33 Each
14 14 Blower motor, suitable for split type Air Conditioner of any make up to and including 3 TR capacity, fixed as in repairs, complete all as specified and directed. Make of fan motor: AUE/ GEC/Himson. 28 Each
15 15 Over load relay, suitable for split type Air Conditioner of any make up to and including 3.0 TR capacity, fixed as in repairs, complete all as specified and directed. 19 Each
16 16 Thermostat, suitable for split type Air Conditioner of any make up to and including 3 TR capacity, fixed as in repairs, completeall as specified and directed. 13 Each
17 17 Starting capacitor, suitable for split type Air Conditioner of any make up to and including 2 TR capacity, fixed as in repairs, complete all as specified and directed. 30 Each
18 18 Starting capacitor, suitable for split type Air Conditioner of any make 2.5 to 3 TR capacity, fixed as in repairs, complete all as specified and directed. 28 Each
19 19 Running capacitor, suitable for split type Air Conditioner of any make up to and including 3 TR capacity, fixed as in repairs, complete all as specified and directed. 29 Each
20 20 Potential relay, suitable for split type Air Conditioner of any make up to and including 3 TR capacity, fixed as in repairs, complete all as specified and directed. 18 Each
21 21 Front grill, suitable for split type Air Conditioner of any make up to and including 3 TR capacity, fixed as in repairs, complete all as specified and directed. 17 Each
22 22 PVC insulated multi stranded copper conductor 3 core 2.5 sq.mm, as in wiring including connecting up and taking down existing unserviceable cable of any description and size, complete all as specified and directed.\nMake: HAVELLS/ FINOLEX/ KALINGA/ POLYCAB/ INCAB/ ANCHOR 80 RM
23 23 All as per Srl Item No 22 here in before but of size 4 core 4 sqmm, complete all as specified and directed. 75 RM
24 24 Refrigerant gas,(R 22) Freon suitable for cooling equipments supplied and filled, complete all as specified and directed. 38 Kgs
25 25 Refrigerant gas,(R 410) suitable for cooling equipments supplied and filled, complete all as specified and directed. 18 Kgs
26 26 Refrigerant gas,(R 32) suitable for cooling equipments supplied and filled, complete all as specified and directed. 30 Kgs
27 27 Copper tube, 15 mm / 18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof, fixed as in repairs, complete all as specified and directed 45 RM
28 28 Copper tube, 9 mm dia, superior quality suitable for refrigeration and discharge lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof, fixed as in repairs, complete all as specified and directed. 45 RM
29 29 Invertor AC Printed Circuite Board (PCB) ,suitable for split type inverter Air Conditioner of any make up to and including 2 TR capacity, fixed as in repairs, complete all as specified and directed. 6 Each
30 30 Servicing complete water cooler, storage type, upto 150 litres capacity including cleaning, checking of electrical/ water supply connections etc. as in preventive maintenance, complete all as specified and as directed. \nNote:Replacement spares, charging of gas, etc. shall be measured and paid separately under relevant items of this Schedule. 45 Each Job
31 31 Relay, suitable for Water Cooler of any make up to 150 litres capacity, fixed as in repairs, complete all as specified and directed. 22 Each
32 32 Thermostat, suitable for Water cooler of any make up to 150 litres capacity, fixed as in repairs, complete all as specified and directed. 22 Each
33 33 Package type relay, suitable for water cooler compressor of any model size and type up to 150 Ltr capacity, fixed as in repairs, complete all as specified and directed. 20 Each
34 34 Hermatically sealed new compressor for water cooler 40/80 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing, fixed as in repairs, complete all as specified and directed.\n Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.\n 7 Each
35 35 All as per Srl item No 34 here in before but for 60/120 litres/Hr capacity, complete all as specified and directed. 3 Each
36 36 All as per Sl item No 34 above but for 150/150 litres/Hr capacity. 2 Each
37 37 Starting capacitor 20/40 mfd, suitable for water cooler of any make and capacity, fixed as in repairs, complete all as specified and directed. 15 Each
38 38 Running capacitor 10 mfd suitable for water cooler of any make and capacity, fixed as in repairs, complete all as specified and directed. 15 Each
39 39 Leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering, fixed as in repairs, complete all as specified and directed. 7 Each
40 40 Self closing push type bib tap 15mm dia made out of cast copper alloy chromium plated suitable for water cooler conforming to ISI mark, including testing and leak proof etc., fixed as in repairs, complete all as specified and directed. 18 Each
41 41 PVC connection pipe 450mm long 15 mm dia with brass unions with washers on both the ends, fixed as in repairs, complete all as specified and directed. 16 Each
42 42 S&F ball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity all as directed. 18 Each
43 43 Supply and fix inreplacement Stainless steel tray suitable for water cooler of 40 / 80 litres capacity all as specified and as directed. 8 Each
44 44 Supply and fix inreplacement Stainless steel tray suitable for water cooler of 150 Litres capacity all as specified and as directed. 2 Each
45 45 M&L for preparing the old painted surface of the water coolers of capacity up to 40/80 Litres and spray painting with synthetic enamel paint all as specified and as directed. 4 Each Job
46 46 M&L for preparing the old painted surface of the water coolers of capacity cap 150 Litres and spray painting with synthetic enamel paint all as specified and as directed. 1 Each Job
47 47 Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and as directed. 2 Each Job
48 48 Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and as directed. 1 Each Job
49 49 S & F inreplacement Electric Condenser fan motor, AC 230 volt, single phase with recommended RPM etc suitable for water cooler of any make of 40/80 litres capacity, all as specified and as directed.\nMake of fan motor: AUE/ GEC/Himson 10 Each
50 50 All as per Sl item No 49 above but for 60/120 litres/Hr capacity. 1 Each
51 51 Blower motor, suitable for split type Air Conditioner of any make up to and including 3 TR capacity, fixed as in repairs, complete all as specified and directed. Make of fan motor: AUE/ GEC/Himson. 2 Each
52 52 Door gasket, suitable for lid of water cooler upto 150 litres capacity, fixed as in repairs, complete all as specified and directed. 16 Each
53 53 Pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning, complete all as specified and directed.\nNote:Topping up of gas will be measured and paid seperately\n 35 Each Job
54 54 All as per Srl item No 53 here in before but for 60/120 litres/Hr capacity, complete all as specified and directed. 1 Each Job
55 55 All as per Srl item No 53 above but for 150/150 litres/Hr capacity, complete all as specified and directed. 1 Each Job
56 56 PVC drain out pipe 30mm dia bore as per existing including providing necessary GI clamps, nut bolt etc., fixed as in repairs, complete all as specified and directed. 15 Each
57 57 Condensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity, fixed as in repairs, complete all as specified and directed. 10 Each
58 58 Evaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity, fixed as in repairs, complete all as specified and directed. 10 Each
59 59 Servicing of Refrigerator, 165 to 255 litres capacity including cleaning, checking of electrical connections etc. complete as in preventive maintenance, complete all as specified and directed. \nNote: Replacement of spares, topping up of gas, etc., \nNote:Replacement spares, charging of gas, etc., if required shall be measured and paid separately under relevant items of this Schedule. 25 Each Job
60 60 All as per Srl item No 59 here in before but for 260 to 310 litres capacity, complete all as specified and directed. 30 Each Job
61 61 All as per Srl item No 59 here in before but for 315 to 360 litres capacity, complete all as specified and directed. 20 Each Job
62 62 Thermostat, suitable for refrigerator of any make 165 to 360 litres capacity, fixed as in repairs, complete all as specified and directed. 35 Each
63 63 Relay, box type, suitable for refrigerator of any make 165 to 360 litres capacity, fixed as in repairs, complete all as specified and directed. 35 Each
64 64 Evaporator coil, suitable for refrigerator of 165 to 255 ltrs any make size and type, fixed as in repairs, complete all as specified and directed. 12 Each
65 65 All as per Srl item No 64 here in before but for 260 to 310 litres capacity, fixed as in repairs, complete all as specified and directed. 10 Each
66 66 All as per Srl item No 64 here in before but for 315 to 360 litres capacity, fixed as in repairs, complete all as specified and directed. 8 Each
67 67 Condensing coil for refrigerator of capacity 165 to 255 Ltr, fixed as in repairs, complete all as specified and directed. 12 Each
68 68 All as per Srl item No 67 here in before but for 260 to 310 litres capacity, fixed as in repairs, complete all as specified and directed. 10 Each
69 69 All as per Srl item No 67 here in before but for 315 to 360 litres capacity, fixed as in repairs, complete all as specified and directed. 8 Each
70 70 Hhermatically sealed new compressor for 165 to 255 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 255 litres, fixed as in repairs, complete all as specified and directed.\n Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase. 6 Each
71 71 All as per Srl item No 70 here in before but for 260 to 310 litres capacity, fixed as in repairs, complete all as specified and directed. 5 Each
72 72 All as per Srl item No 70 here in before but for 315 to 360 litres capacity, fixed as in repairs, complete all as specified and directed. 5 Each
73 73 Gasket, suitable for door of Refrigerator of any make, 165 to 255 litres capacity, fixed as in repairs, complete all as specified and directed. 10 Each
74 74 All as per Srl item No 73 here in before but for 260 to 310 litres capacity, fixed as in repairs, complete all as specified and directed. 10 Each
75 75 All as per Srl item No 73 here in before but for 315 to 360 litres capacity, fixed as in repairs, complete all as specified and directed. 10 Each
76 76 Preparing the old painted surface of refrigerator of capacity 165 litres to 360 litres and spray painting with synthetic enamel paint of approved colour, complete all as specified and directed. \n 3 Each Job
77 77 Freezer door, suitable for Refrigerator of any make, 165 to 255 litres capacity, fixed as in repairs, complete all as specified and directed. 10 Each
78 78 All as per Srl item No 77 here in before but for 260 to 310 litres capacity, fixed as in repairs, complete all as specified and directed. 6 Each
79 79 All as per Srl item No 77 here in before but for 315 to 360 litres capacity, fixed as in repairs, complete all as specified and directed. 8 Each
80 80 Chiller tray, suitable for Refrigerator of any make, 165 to 255 litres capacity, fixed as in repairs, complete all as specified and directed. 10 Each
81 81 All as per Srl item No 80 here in before but for 260 to 310 litres capacity, fixed as in repairs, complete all as specified and directed. 10 Each
82 82 All as per Srl item No 80 here in before but for 315 to 360 litres capacity, fixed as in repairs, complete all as specified and directed. 10 Each
83 83 Vegetable tray, suitable for Refrigerator of any make, 165 to 255 litres capacity, fixed as in repairs, complete all as specified and directed. 15 Each
84 84 All as per Srl item No 83 here in before but for 260 to 310 litres capacity, fixed as in repairs, complete all as specified and directed. 10 Each
85 85 All as per Srl item No 83 here in before but for 315 to 360 litres capacity, fixed as in repairs, complete all as specified and directed. 12 Each
86 86 Pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 255 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning, complete all as specified and directed.\nNote:Topping up of gas will be measured and paid seperately 10 Each Job
87 87 All as per Srl item No 86 here in before but for 260 to 310 litres capacity, complete all as specified and directed. 8 Each Job
88 88 All as per Srl item No 86 here in before but for 315 to 360 litres capacity, complete all as specified and directed. 4 Each Job
89 89 Ice superior quality plastic/PVC Ice cube tray for refrigerator of cp 200 Ltrs to 310 ltrs, complete all as specified and directed. 20 Each
90 90 Magnetic beeding for refrigetator of cap 200 ltrs to 310 ltrs, fixed as in repairs, complete all as specified and directed. 15 Each
91 91 Electric bulb 20 watt 230v threaded type for refrigetator of cap 200 ltrs to 310 ltrs, fixed as in repairs, complete all as specified and directed. 10 Each
92 92 Hermatically sealed new compressor for deep freezer of capacity 200 to 300 ltr including disconnecting the electrical and refrigerant connection of defective sealed unit ofdeep freezer 200 to 300 litres and connection of all pipe line & charging of refrigerant and testing, complete all as specified and directed \nNote:- \n(a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase. 2 Each
93 93 All as per Srl item no 92 here in before but of capacity 400 to 500 ltr, complete all as specified and directed.\n 1 Each
94 94 Supply and charging of refrigerant gas R-134a to water cooler , refrigerator and deep freezer of any type, make and capacity, complete all as specified and as directed 40 Kg
95 95 Top plug 3 pin 15 A bakelite, fixed as in repairs, complete all as specified and directed. 80 Each
96 96 Top plug 3 pin 5A bakelite, fixed as in repairs, complete all as specified and directed. 45 Each
97 97 Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance alongwith blower assembly filter and other components including checking electrical connections, complete all as specified and directed.\n 10 Each Job
98 98 Blower motor assembly of Air curtain unit of any type capacity and length, single phase AC, 230 Volts as including electrical connections, complete all as specified and directed.\n 4 Each
99 99 Dismantling the transformer from the stabilizers of following capacity and removing the old / burnt transformer and replaced with new transformer, complete all as specified and directed.
100 99.01 (a) 0.5 KVA 4 Each
101 99.02 (b) 1 KVA 4 Each
102 99.03 (c) 2 KVA 5 Each
103 99.04 (d) 4 KVA 9 Each
104 99.05 (e) 5 KVA 8 Each
105 100 Replacement of following spare parts for 1 KVA to 2 KVA capacity stabalizers, complete all as specified and directed.
106 100.01 (a) Relay set ( set of two ) 3 Each
107 100.02 (b) PCB ( Printed circuit board) 3 Each
108 101 Replacement of following spare parts for 4 KVA to 5 KVA capacity stabalizers, complete all as specified and directed.
109 101.01 (a) Relay set ( set of two ) 6 Each
110 101.02 (b) PCB ( Printed circuit board) 7 Each
111 102 Digital voltmeter 0-250volt for stabilizers any type as per existing, fixed as in repairs, complete all as specified and directed. 12 Each
112 103 Heat insulation superior quality nitrile rubber of 9 mm thickness, ISI marked for copper tubing of any size of refrigerant line including necessary clamps,PVC tape knots,in all respects, fixed as in repairs, complete all as specified and directed. 290 Rm
113 104 Printed circuite board (PCB) suitable for refrigerator 165 Ltr to 255 ltr capacity of any make, fixed as in repairs, complete all as specified and directed. 8 Each
114 105 All as per Srl item No 104 here in before but for 260 to 310 Ltrs capacity, fixed as in repairs, complete all as specified and directed. 5 Each
115 106 All as per Srl item No 104 here in before but for 315 to 360 Ltrs capacity, fixed as in repairs, complete all as specified and directed. 4 Each