Special Repairs To Bldgs No E-21 ( Or Living ) Of 554 Asc Bn And Provn Of Ramp For Bldg No P-172 At Mh Secunderabad Of Age B/R ( South ) No . I And Age E/M ( South ) Under Ge ( South ) Secunderabad
Tender Overview
Project Description
Special Repairs To Bldgs No E-21 ( Or Living ) Of 554 Asc Bn And Provn Of Ramp For Bldg No P-172 At Mh Secunderabad Of Age B/R ( South ) No . I And Age E/M ( South ) Under Ge ( South ) Secunderabad
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-Jun-2021 | amendment to tender documents | Other | 12-Jun-2021 |
| 2 | 03-Jun-2021 | amendment to tender documents | Other | 12-Jun-2021 |
| 3 | 04-Jun-2021 | amendment2 | Other | 12-Jun-2021 |
| 4 | 12-Jun-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-Jun-2021 |
BOQ
| Name of Work: SPECIAL REPAIRS TO BLDGS NO E-21 (OR LIVING) OF 554 ASC BN AND PROVN OF RAMP FOR BLDG No P-172 AT MH SECUNDERABAD OF AGE B/R (SOUTH) NO. I AND AGE E/M (SOUTH) UNDER GE (SOUTH) SECUNDERABAD | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Excavation in trenches, not exceeding 1.5 m wide or not exceeding 10 sq m on plan and not exceeding 1.5 m in depth for foundation of manhole etc and getting out as in soft/loose soil complete all as specified and as directed. | 26 | Cum | |
| 2 | 2 | Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick , including watering ,ramming complete all as specified and as directed. | 14 | Cum | |
| 3 | 3 | Surface dressing n.exc 15 cm deep and getting out of soft or loose soil complete all as specified and as directed . | 175 | Sqm | |
| 4 | 4 | M&L for sand cushion 25 to 30mm thick for fixing of inter locking tiles complete all as specified and as directed. | 3.75 | Cum | |
| 5 | 5 | Removing of soil to distance n.exc 50 mtr and depositing at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed . | 12 | Cum | |
| 6 | 6 | M&L hard core of gauge n exc 63 mm deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and as directed. | 30.3 | Cum | |
| 7 | 7 | Material and Labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling complete all as specified and as directed . | 3.3 | Cum | |
| 8 | 8 | M&L for PCC 1:2:4 type B1 20 mm graded aggregate as in coping, haunching and edging etc complete all as specified and directed. | 3 | Cum | |
| 9 | 9 | M&L for PCC 1:3:6 type C-1 using 20 mm garged aggregate for fixing holdfast complete all as specified and as directed. | 0.8 | Cum | |
| 10 | 10 | Material and Labour for RCC 1:1.5:3 Type A1 ( using 20 mm graded stone aggregate ) as in foundation , plinth beams , footing , under reamed piles and mass concrete complete all as specified and as directed . | 5.6 | Cum | |
| 11 | 11 | Material and Labour for RCC 1:1.5:3 Type A1 ( using 20 mm graded stone aggregate ) as in slab supported on wal , beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. | 10 | Cum | |
| 12 | 12 | Material and Labour for RCC 1:1.5:3 Type A1 ( using 20 mm graded stone aggregate ) as in RCC Beam / cantilever / lintel over 1.50 m span complete all as specified and as directed . | 7 | Cum | |
| 13 | 13 | Material and Labour for RCC 1:1.5:3 Type A1 ( using 20 mm graded stone aggregate ) as in RCC column complete all as specified and as directed . | 5 | Cum | |
| 14 | 14 | Material and Labour for RCC 1:1.5:3 Type A1 ( using 20 mm graded stone aggregate ) as in fins, fascias, louvres,parapets and railings exc.60cm in height complete all as specified and as directed . | 8 | Cum | |
| 15 | 15 | Supply only integral water proofing compound . | 110 | KG | |
| 16 | 16 | M&L brick work with subclass B bricks ,straight or curved on plan exc 6m mean redius built in cm 1:6 complete all as specified and as directed. | 10 | Cum | |
| 17 | 17 | M&L brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall built in cement motor 1:4 complete all as specified and as directed. | 30 | Sqm | |
| 18 | 18 | Use and waste of form work to the side of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams complete all as specified and as directed . | 26 | Sqm | |
| 19 | 19 | Use and waste of form work to soffits of suspended slabs such as roof slab , floor slabs , landings and similar work n.excceding 200 mm thick complete all as specified and as directed . | 186 | Sqm | |
| 20 | 20 | Use and waste of form work as in sides and soffit of floor or roof beams , beam haunchings girders , bressummers , lintels , cantilevers , shelves moulding supports , overhangs etc also splays between floor and beams etc complete all as specified and as directed . | 30 | Sqm | |
| 21 | 21 | Use and waste of form work to the side of RCC column incl finish the surface rough complete all as specified and as directed . | 77 | Sqm | |
| 22 | 22 | Use and waste of formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide including finish the surface rough complete all as specified and as directed . | 62 | RM | |
| 23 | 23 | S&F 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed. | 0.61 | Cum | |
| 24 | 24 | S &F 2nd class hardwood 35mm thick glazed and skeleton shutters open rebated and prepared to receive glass gauze etc divided into squares, with plain, chamfered or rounded mitred and rebated sash bars any number edges of framing plain, chamfered or rounded, fitted with cut and metered beads for securing glass etc size of members of shutters as specified in SSR Part I Sec 8 clause 8.24 (a) complete all as specified and as directed. | 17.64 | Sqm | |
| 25 | 25 | S&F for Factory made 35mm thick 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the side of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and as directed. | 17.64 | Sqm | |
| 26 | 26 | Taking down frames with shutters (without taking off shutters from the frame ) area not exc 1.5 Sqm Each incl iron mangery complete all as specified and as directed. | 27 | Each | |
| 27 | 27 | Taking down shutters with frames (without taking off) shutters from the frame) exc 1.5Sqm but n.exc 4 Sqm Each complete all as specified and as directed. | 6 | Each | |
| 28 | 28 | S & F 150mm long Aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed. | 56 | Each | |
| 29 | 29 | S & F 300 mm long aluminium alloy anodised sliding door bolt with hasp staple (bolt type ) and fixing clips of sheets ,cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and as directed. | 14 | Each | |
| 30 | 30 | S & F 100mm size mild Steel butt hinges medium weight cold rolled complete all as specified and as directed. | 42 | Each | |
| 31 | 31 | S&F 300 mm ordinary rat rail rod pattern spring including roller and roller plate complete all as specified and as directed. | 14 | Each | |
| 32 | 32 | M&L 150 mm length Aluminium handles fabricated type anodised complete all as specified and as directed. | 56 | Each | |
| 33 | 33 | M&L for door stoper of aluminium alloy body Rubber 140 mm long complete all as specified and as directed. | 56 | Each | |
| 34 | 34 | S&F galvanised mild steel wire 0.56mm nominal dia of wire and average width of aperture 1.18mm complete all as specified and as directed. | 70 | Sqm | |
| 35 | 35 | S&F for framed work such as grill, gratings, etc with ends of bars shouldered and/or riveted or forged in to spikes, framed guard bars, barred iron doors ladders framed balusters and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed. | 400 | KG | |
| 36 | 36 | M&L for Mild Steel flat iron as in hold fast supplied and fixed including tarring complete all as specified and as directed. | 20 | KG | |
| 37 | 37 | Material and Labour TMT bar 10mm dia and over cut to length, bent to shape as required and binding with MS wire n.less than 0.9 mm dia annealed complete all as specified and as directed | 1600 | KG | |
| 38 | 38 | All as per Item No 37 above but 6 to 8 mm dia . | 1200 | KG | |
| 39 | 39 | All as per item No.37 above but 5 to 10 mm dia as in stirrups complete all as specified and as directed . | 700 | KG | |
| 40 | 40 | S&F rolled Mild steel sections as in main and cross beams hip and jack rafters, purlines fixed independently including welding complete all as specified and as directed. | 3900 | KG | |
| 41 | 41 | S&F steel window with side hung double shutters on both sides to receive glass on one side shutters and to receive gauze on other side shutters including projection type hinges with steel handle on both side shutters and steel peg stay ,complete with glazing bars complete all as specified and as directed | 38.88 | Sqm | |
| 42 | 42 | S&F steel Ventilators with top hung shutters including hinges steel peg stay, complete all as specified and as directed . | 1 | Sqm | |
| 43 | 43 | S&F aluminium snap grid made of aluminium anodised sections such as wall angle of size 25x25x1.8mm and main/cross tees of size 25x25x1.6 mm, and grid size not exc 610x610 mm suspended with GI wire at intervals not exc 600 mm C/C from main and cross tees fixed to roof truss fixed etc. complete all as specified and as directed. | 305 | Sqm | |
| 44 | 44 | S & F Pre-painted galvatume aluminum zinc coating GI vased corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed. | 550 | Sqm | |
| 45 | 45 | S & F Pre-painted galvatume aluminum zinc coating GI vased Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ridge to wall fixed with self tapping screws complete all as specified and as directed. | 50 | Sqm | |
| 46 | 46 | M&L machine cut polished sahabad stone flooring in CM (1:6) 20 mm thick (minimum) over cement screed base laid and jointed and pointed in CM 1:3 with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc, complete all as specified and as directed. | 400 | Sqm | |
| 47 | 47 | All as per Sl item No 46 above but in skirting /dados over cement backing in CM (1:4) etc, complete all as specified and as directed. | 50 | Sqm | |
| 48 | 48 | M&L for 75 mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in sub base of floor etc complete all as specified and as directed. | 630 | Sqm | |
| 49 | 49 | M&L Machine pressed precast concrete interlocking paver block of approved shape and size confirming to IS 15658-2006 of 80 mm thickness with grey cement and no pigment, M-40 Grade of approved colour and design complete all as specified and as directed | 150 | Sqm | |
| 50 | 50 | M&L for 10 mm thick backing coat on vertical surfaces such as skirting/dado in CM 1:4 for laying stone complete all as specified and as directed. | 50 | Sqm | |
| 51 | 51 | Taking down cement plaster hacking of key racking out joint of old brick work or stone work complete all as specified and as directed. | 800 | Sqm | |
| 52 | 52 | M&L sheet glass 3mm thick ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in Each pane complete all as specified and as directed. | 42 | Sqm | |
| 53 | 53 | M&L for sheet glass 3mm thick figured glass, pin headed type and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in Each pane complete all as specified and as directed. | 0.6 | Sqm | |
| 54 | 54 | Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed. | 70.56 | Sqm | |
| 55 | 55 | M & L for preparation of new steel surfaces and applying 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. | 117.64 | Sqm | |
| 56 | 56 | Demolition of Brickwork or stone / boulders masonry laid drybuilt in cement mortar complete all as specified and as directed. | 13.45 | Cum | |
| 57 | 57 | Dismantaling stone slabs and tiles of any description or thickness in floor ,aprones laid bedded and pointed in any mortar complete all as specified and as directed. | 48 | 10 Sqm | |
| 58 | 58 | Demolition of cement concrete in ground floor and paving n exc 15 cm thickness below and above ground level complete all as specified and as directed. | 62.33 | Cum | |
| 59 | 59 | Dismantling mild steel/wrought iron work of any description not otherwise provided complete all as specified and as directed. | 39 | Per Qtl | |
| 60 | 60 | Dismantling of AC sheets (corrugated and semicorrugated etc) in roofing incl ridge tiles complete all as specified and as directed. | 600 | Sqm | |
| 61 | 61 | Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets complete all as specified and as directed. | 310 | Sqm | |
| 62 | 62 | M&L for non asbestos fibre cement building boards 4 mm thick fixed or laid/inserted to timber / GI / Aluminium framework, fixed in ceiling with nails to timber frame work or with staples on snap grid and applying two coats of OBD over a coat of primer. complete all as specified and as directed. | 300 | SQM | |
| 63 | 63 | M & L for cement concrete 1:3:6 type C-1, 75 mm thick (using 20mm graded stone aggregates) as in plinth protection finished fair and even without using extra cement complete all as specified and as directed. | 153 | Sqm | |
| 64 | 64 | Material and labour for PCC coloured chequared cement concrete tile of size 300 mm X 300 mm X 25 mm thick as in floor , set , jointed and pointed in neat cement slurry with grey cement and pigment , laid over 20 mm thick screed bed with CM 1:6 complete all as specified and as directed . | 160 | Sqm | |
| 65 | 65 | Material and labour for rendering 5 mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified. | 82 | Sqm | |
| 66 | 66 | Material and labour for rendering 5mm thick in cement mortar (1:4) including WPC over a layer of 10 mm thick in CM 1:6 on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and as directed. | 345 | Sqm | |
| 67 | 67 | M&L for rendering 15mm thick in CM 1:6 on fair faces of brick/concrete finished even and smooth without using extra cement complete all as specified and as directed. | 500 | Sqm | |
| 68 | 68 | M&L for 20 mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and as directed. | 400 | Sqm | |
| 69 | 69 | M&L for prepration of new plaster surface of walls and applying two coat of oil bound distempers over one coat of primer and two coat of wall care putty complete all as specified and as directed. | 500 | Sqm | |
| 70 | 70 | Complete removal of existing treatment and applying two coat of OBD over over a coat of alkali resistant primer including applying two coats of wall care putty complete all as specified and as directed . | 50 | Sqm | |
| 71 | 71 | M&L complete removal of existing treatment applying two coat of cement base paint over a coat of alkali resistant primer paint on walls complete all as specified and as directed . | 50 | Sqm | |
| 72 | 72 | Complete removal of existing treatement and applying two coats of white wash on walls, etc complete all as specified and as directed. | 20 | Sqm | |
| 73 | 73 | M&L for preparation of new plastered or un- plastered surfaces and walls including cornices, pilasters etc and applying two Coats of cement base paint over a coat of primer complete all as specified and as directed. | 330 | Sqm | |
| 74 | 74 | Material and labour for preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and as directed. | 80 | Sqm | |
| 75 | 75 | Material and labour for preparation of new plastered on wall including applying two coats of weather proof exterior emulsion paint over a coat of primer complete all as specified. Make : ASIAN PAINTS ( APEX ULTIMA ) or any other equivalent complete all as specified and as directed. | 130 | Sqm | |
| 76 | 76 | Taking down existing unserviceable point wiring of any description/type/ size of light/ fan/tube/power/two way/bell point etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed. | 165 | POINT | |
| 77 | 77 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed. | 3 | Each | |
| 78 | 78 | M & L for Concealed Conduit Point wiring with 1.5 Sq mm copper conductor single core PVC insulated cable FRLS type 1100 V multistranded drawn through conduit and including rigid PVC conduit and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 1.6 mm thick MS duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated hylam sheet including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc all as specified for:- one light point controlled by one, one way switch 5A, SP | 85 | POINT | |
| 79 | 79 | All as Sl item No 78 above but one ceiling / exhaust fan point controlled by one, one way switch | 28 | POINT | |
| 80 | 80 | All as Sl item No 78 above but one 2/3 pin 5 Amps switch socket outlet point controlled by one switch on the same board | 10 | POINT | |
| 81 | 81 | All as Sl item No 78 above but one 3 Pin 5 Amps switch socket Independt board | 40 | POINT | |
| 82 | 82 | All as Sl item No 78 above but using 4 Sq mm single core copper conductor cable of multistranded PVC insulated FRLS 1100 Volts grade for 5/15 Amps switch socket combination point including running of 4 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. | 2 | POINT | |
| 83 | 83 | S & F Switch piano type single pole one way flush type 5 Amps capacity 230 volts. | 123 | EACH | |
| 84 | 84 | Supply and fix switch socket combination flush type multipurpose 2/3 pin 5 Amps, 230 Volts complete all as specified and as directed. | 40 | EACH | |
| 85 | 85 | Supply and fix socket outlet flush type multipurpose 2/3 pin 5 amps, 230 volts complete all as specified and as directed. | 10 | EACH | |
| 86 | 86 | Supply and fix switch socket combination flush type multipurpose 5 in 1, 5/16 Amps, 230 Volts complete all as specified and as directed. | 2 | EACH | |
| 87 | 87 | S & Fix ceiling fan regulator step type AC 240 volt suitable for 1200/1400 mm sweep complete all as specified and as directed. | 28 | Each | |
| 88 | 88 | S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and as directed. | 113 | EACH | |
| 89 | 89 | S&F sheet metal enclosure vertical type MCB DB TPN 4 way double door with 200 Amps rated bus bar 415 volts suitable for and including 63 Amps TPN MCCB 16 KA as incommer and 12 Outgoing SP MCB's with magnetic locking system complete all as specified. Note: MCB SP Shall be measured and paid seperately, all as specified and directed by Engg in Charge | 1 | EACH | |
| 90 | 90 | S and F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 Volts double door with magnetic locking system complete all as specified and as directed. | 2 | EACH | |
| 91 | 91 | S & F MCB SP 230V suitable for fixing on MCB DB of capacity 6 to 32 Amps complete all as specified and directed by Engg in Charge | 24 | EACH | |
| 92 | 92 | S & F MCB SPN 230V suitable for fixing on MCB DB of capacity 40 Amps complete all as specified and directed by Engg in Charge | 2 | EACH | |
| 93 | 93 | S & F wall mounted box type LED of 18/22 watt with LED Lamp, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with 2 Nos round blocks with necessary fixing arrangements and connecting to the point wiring with necessary flexible copper conductor multistranded three core of suitable length & size from fitting to the ceiling rose complete all as specified and as directed by Engr-in-Charge. | 40 | EACH | |
| 94 | 94 | S & F LED bed side light fitting with lamp capacity 7W, 6500K, adjustable type including all accessories and as directed by Engr-in-Charge. Make : Havells, Bajaj, Philips | 40 | Each | |
| 95 | 95 | M & L for Submain wiring with two single core 6 Sq mm PVC insulated FR copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC concealed conduit and conduit accessories of 25 mm dia medium grade including running up of 6 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length. | 40 | RM | |
| 96 | 96 | Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth earth lead 4 mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe med grade 15mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI pipe med grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 5 of SSR Part-I and connection to earth test point all as specified incl testing on completion. Note :- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 4 mm size and protection pipe of 15 mm bore GI light grade. | 2 | EACH JOB | |
| 97 | 97 | Disconnecting and removing ceiling fan of 1200/1400 mm sweep any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler , one coat after cleaning all dust etc & testing complete all as specified. NOTE :- (1) Necessary repairs/ replacement of unserviceable parts shall be measured and paid seperately.(2)Labour element for replacing of u/s parts deemed to be included in rate quoted. | 14 | JOB | |
| 98 | 98 | Material and labour for rewinding of the ceiling fan complete with equivalent new super enamelled copper wire of existing gauge and weight as per manufacturer's design and instructions including varnishing for ceiling fan of any make and any sweep complete all as specified and directed including taking out burnt copper wire. Note: old winding material is property of the contractor :- Supply only the following items suitable for ceiling fans / exhaust fans of any size and sweep and make. | 14 | JOB | |
| 99 | 99 | All as Sl item No 98 above but Capacitor 2.5 Mfd capacity 240 Volts. | 28 | EACH | |
| 100 | 100 | All as Sl item No 98 above but Sealed ball bearing | 56 | EACH | |
| 101 | 101 | All as Sl item No 98 above but Rubber bushes | 28 | EACH | |
| 102 | 102 | S & F Security Lights of 1x25 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all as specified and as directed by Engg-in-Charge. | 5 | Each | |
| 103 | 103 | M & L bracket made out of GI pipe of suitable dia not less than 1.2 mtr long and fixed on walls with 2 nos MS clamps made out of MS flat of suitable size thick complete with MS nuts, bolts and washers etc bent to required shape complete all as specified and as directed by Engg-in-Charge | 5 | Each |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender