BOQ
| Sl. No. | Item Description |
| 1 | Desilting the Supply Well, Intake Well / Head Works, sump of water supply/ sewerage works etc. in wet or dry condition including lifts upto 10.5 M and lead upto 150 M as required beyond the work site, stacking, spreading, including necessary guarding, etc. complete, as directed by Engineer-in-charge.Lift 7.50.to 9.00 M |
| 2 | Excavation in general in hard material comprising of soft rock, hard rock, Manjara rock, etc. by blasting/ controlled blasting, chiseling as required in wet or dry condition for Supply Well for lift 0 to 1.50 M and lead of 150 M including barricading, guaLift 9.00.to 10.50 M |
| 3 | Lift 10.50.to 12.00M |
| 4 | Lift 12.000.to 13.50 M |
| 5 | Dewatering the excavated trenches and pools of water in the building/ trench area by using pumps and other devices including disposing of the water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel) etc. complet |
| 6 | Dierrecting and errecting of Pumping machinary……..etc |
| 7 | Making of Horizontal Bore……..etc( with DTH) |
| 8 | Drilling of Bore well in all types of strata 150 in all types of strataincluding all charges ---------- etc. complete.As per GSDA Given rate |
| 9 | Providing and fixing150 mm dia M.S. casing pipe class B 4.85 mm as per IS 1239 (Blank)As per GSDA Given rate |
| 10 | Providing and fixing 150 mm dia M.S. casing pipe class B 4.85 mm as per IS 1239 (Slotted)As per GSDA Given rate |
| 11 | Providing and fixing 150 mm dia M.S. CAP As per GSDA Given rate |
| 12 | Providing and fixing wooden block for support to clamp of bore well As per GSDA Given rate |
| 13 | Providing and fixing M.S. clamp for support to clamp of Tube well As per GSDA Given rate |
| 14 | Yeild test As per GSDA Given rate |
| 15 | Trandportation of drilling rig and unit upto site of work ---------- etc. complete. As per GSDA Given rate |
| 16 | Development of BoreAs per GSDA Given rate |
| 17 | Providing and fixing M.S. bell cap for Tube well As per GSDA Given rate |
| 18 | Providing, erecting and giving test of 150 mm dia. Submersible Pump sets conforming to I.S. 8034 & I.S. 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and bronze impeller Motor suitable for working on 415 +/- 10%, 3 Ph, 50 Hz, A.C. supply, cable guard, thrust carbon/ fibre bearing to accept entire hydraulic thrust, waterproof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturer’s design. Antitrust stream lined non-return valve shall be provided with the pump. Suitable suction strainer shall also be provided. 3 core, single/double run copper conductor submersible type flat cable 3 m and 2 pairs of erection clamps shall be provided along with the pump.Pump set – 5.00 H.P., Q = 64700 Lph, H=70 Mt.(E&M CSR 2019-20,It. No.PM 1-2-2, P.No 1)1 for bore well and 1 for supply well |
| 19 | Supplying and erecting G.I.pipe ‘‘Medium’ class in position for drop pipe for Submersible pump including plumbing with sockets & necessary material (CSR 2019-20 (Civil), It. No.1 (b), P.No77)Drop Pipe- 50 mm dia. G.I. ‘‘Medium’ classRate = 300.00 + 61.00 (L/L) =361.00 |
| 20 | Providing, erecting C.I.D.F. Sluice valves with jointing to pipe work (including all hardware and packing) water works quality having non-rising spindle with hand wheel and without bypass arrangement, spindle of stainless steel as per requirement excluding C.C. foundation/ structural steel supports.50 mm dia. C.I.D.F. Sluice valve (PN-1.0)(Civil CSR 2019-20, It. No.2 (c) i, P.No 124)Rate = 4917 + 757 = 5674.00 |
| 21 | Providing, erecting C.I.D.F. Reflux valves single door with jointing to pipe work (including all hardware and packing) water works quality with jointing to pipe without bypass arrangement with gunmetal seats excluding c.c. Foundation/ structural steel supports.( CSR 2019-20, It. No.1(c) I, P.No 122)50 mm dia. C.I.D.F. Reflux valve (PN-1.0) |
| 22 | Lowering, laying and jointing in position following CIDF Reflux valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. 50 mm dia. C.I.D.F. Reflux valve (PN-1.0)( CSR 2019-20, It. No.4 , P.No 127) |
| 23 | Supplying and erecting ‘B’ class G.I. Bend in position with necessary material.50 mm dia. G.I. Bend ‘B’ class(E&M CSR 2019-20, It. No. PW 3-4, P.No 17) |
| 24 | Supplying and erecting ‘B’ class G.I. Coupling in position with necessary material.50 mm dia. G.I. coupling ‘B’ class(E&M CSR 2019-20, It. No. PW 3-4, P.No 17) |
| 25 | Supplying and erecting ‘B’ class G.I. screwed flange (B.S. 10 table ‘D’) in position with necessary nut bolts, washers with rubber packing.50 mm dia. G.I. Flange ‘B’ class |
| 26 | Supplying and erecting flat flexible submersible cable with 3 core PVC insulated, PVC sheathed copper conductor.(E&M CSR 2019-20, It. No. CB 1, P.No 67)3 core, 4 Sqmm |
| 27 | Providing Panel board fabricated of M.S. sheet with T.P. Switch 32 amp 2 No, Ammeter 96 x 96 sq mm 1 No, Voltmeter 96 x 96 sq mm 1 No, Selector switch 1 No, Pilot Lampset 1 No, Single phase preventer 2 No, Mixed Di Electric Capacitor,DOL starter 12 amp 2 No, Danger board 1 No, ELCB 63 A-4 Pole 1 phase, Rubber matting, 16 SWG M.S.sheet, Change over switch 63 amp 1 No, Self locking arrangement 2 No, Marine ply wood 0.675 Sqm, 10 kg Iron work including cutting, bending, drilling, welding, cleaning, derusting and painting with one coat of red lead paint and two coats of enamel paint.(As per Rate Analysis) |
| 28 | Supplying and erecting galvanized cast iron earth plate 60x60x0.6 cm buried in specifically prepared earth pit 1.5 m below ground level with 30 kg Charcoal and Salt inalternate layers, Necessary length of double G.I. earth wire 8 SWG connected to plate with cadmium plate, G.I. nut bolts 12 mm dia. with bituminous compound and run through 12 mm dia. G.I. pipe 3 m long, remaining portion of G.I. wire from surface of earth to switch gear in PVC pipe upto accessible height duly sealed at both ends by bituminous compound complete to the nearest switch gear with end socket as per direction and duly tested by earth tester and recording the results and including supplying & erecting 19 mm dia. Vertical G.I. pipe 1.5 m long with funnel and mesh at top. |
| 29 | Providing & laying in situ following grade of C.C of trap/granite/quartzite/gneiss metal for foundation & bedding including dewatering, formwork, compacting and curing, finishing etc. complete. |
| 30 | Electrification of Switch Room including all material and labour cost and as directed by Engineer-in-charge…..etc Complete. |
| 31 | Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).90 mm dia 6 kg/cm2 |
| 32 | Providing I.S.I. mark G.I. pipes and specials of following class and diameter including all local and central taxes, octroi, inspection charges, conveyance upto site of work etc. complete.80 mm dia. Medium class G.I. Pipes |
| 33 | Providing and supplying ISI mark C.I.D.F. sluice valves of following dia.Including all taxes (Central & Local), railway freight, insurance, unloading from railway wagon, loading into truck, transport to site, unloading, stacking, etc. complete80 mm dia. CIDF Scour/ Sluice Valve (PN 1.0) |
| 34 | 80 mm dia. CIDF Refluxe Valve (PN 1.0) |
| 35 | Providing & fixing in position and jointing high performance C.I. Air valves for water combination type (Kinetic Air Valve along with automatic air valves) double ball, double orifice with stainless steel ball, tamper proof air vents rolling seal mechanism for air release and anti vacuum application designed for 16 kg. per Sq.Cm working pressure and tested for 20 for kg per Sq.cm. pressure (Rate to include cost of gaskets, bolt, nut and amy other material required for jointing and its transportation etc. including all taxes and duties except octroi) C.I. ARV FLFF PN 1.6 50mm dia |
| 36 | Excavation for foundation/ pipe trenches in earth soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 meters & lifts as below, stacking & spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling etc. |
| 37 | Excavation for foundation/ pipe trenches in hard murum and boulder including removing the excavated material upto a distance of 50 meters beyond the area & lifts as below, stacking & spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling etc. complete. |
| 38 | Excavation for foundation/ pipe trenches in soft rock and old cement & lime masonry foundation, asphalt road including removing the excavated material upto a distance of 50 meters beyond the area & lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation excluding backfilling etc. complete. |
| 39 | Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling, by machnial means or by any other means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete |
| 40 | Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, giving satisfactory hydraulic testing as per IS code, etc. complete (with cement solvent joint / ring fit joint).90 mm dia 6 kg/cm2 |
| 41 | Lowering, laying and jointing G.I. pipes and specials of following class and diameter including conveyance upto site of work, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position, as directed by Engineer-in-charge.80 mm dia. Medium class G.I. Pipes |
| 42 | Lowering, laying and jointing in position following CIDF Sluice valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.80 mm dia. CIDF Scour/ Sluice Valve (PN 1.0) |
| 43 | 80 mm dia. CIDF Refluxe Valve (PN 1.0) |
| 44 | Providing and fixing in position air valve shaft including providing and fixing GI medium class or 6mm thick M.S pipe shaft 2070m long over branch flange of air valve tee, providing PCC block ofM150 concrete 150mm thick around the air valve tee including encasing of vertical shaft in PCC M150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee. Etc compt. As per type design and as directed by engineer-in-charge for following diameter of pipe lines. |
| 45 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lift including consolidation, surcharging etc. complete. |
| 46 | Providing & laying in situ following grade of C.C of trap/granite/quartzite/gneiss metal for foundation & bedding including dewatering, formwork, compacting and curing, finishing etc. complete. |
| 47 | Leakage repairing of Rising main and Distribution line ……..etc90 mm 4 kg/ 6 KG |
| 48 | Supplying, Installing,Testing and commissioning of 2 HP capacity AC/DC Solar water pump(SPV pump), comprising of min.2 KWp capacity multi crystalline SPV modules mounted on GI Structure with necessary hardware with controller, suitable size HDPE delivery water pipe line up to 60mtr length inside or above water tank/borewell with necessary control valves and necessary power supply cable of appropriate size complete. With 5 years on site performance warranty as per specification no. ESD-SWPS |
| 49 | Providing and Supplying Blue MDPE pipes conforming to ISO 4427:1996 manufactured from virgin resin PE 80 Food grade compounded Raw Material having Blue Colour only with quality assurance certificate from quality agencies like WRC /CIPET (India) /DVGM /KIWA /SPGN etc. for usage in Drinking Water system. The cost shall include testing of all materials, Inspection charges, transportation up to store, transit insurance, loading, as specified and directed, unloading, stacking excluding GST levied by GOI & GOM in all respect, etc. complete as specified and directed |
| 50 | Supplying, erecting& terminatingXLPE armoured cable 3 core4sq. mm. copperconductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 51 | Providing and supplying ISI standard CI flanged / S& S specials including all statutory duties & taxes such as GST levied by GOI & GOM in all respect, railway freight, insurance, unloading from railway wagon, loadinginto truck transport to departmental store /site, unloading stacking etc. complete |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender