Repairs Replacement Of Burnt Defective Mcb Db Mccb Bldg Earthing Pits And Other Misc Items At Af Stn Suryalanka As Per Boq And Tender Document

Issued by Statutory Bodies & Commissions/Committees · SURYALANKA, Andhra Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
14 Jun 2021
0 days left
EMD
12600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
SURYALANKA → Andhra Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repairs Replacement Of Burnt Defective Mcb Db Mccb Bldg Earthing Pits And Other Misc Items At Af Stn Suryalanka As Per Boq And Tender Document

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 29-May-2021 Amendment to tender documents Financial Bid 08-Jun-2021
2 08-Jun-2021 Date Corrigendum Date 14-Jun-2021

BOQ

Name of Work: REPAIRS/ REPLACEMENT OF BURNT/ DEFECTIVE MCB / DB / MCCB, BLDG EARTHING PITS AND OTHER MISC ITEMS AT AF STN SURYALANKA
Sl.No.Description of Item of WorksItem Code / MakeApproximate No. of Units RequiredUNIT
11S&F in replacement of MCB, SP 6-32 Amps, C Curve, 10 kA, Complete all as specified and as directed.220Each
22S&F in replacement of MCB, SP 40 Amps, C Curve, 10 kA, Complete all as specified and as directed.50Each
33S&F in replacement of MCB, SPN 6-32 Amps, C Curve, 10 kA, Complete all as specified and as directed.80Each
44S&F in replacement of MCB, SPN 40 Amps, C Curve, 10 kA, Complete all as specified and as directed.40Each
55S&F in replacement of MCB, Four Pole 40 Amps, C Curve Complete all as specified and as directed.9Each
66S&F in replacement of MCB, Four Pole 63 Amps, C Curve Complete all as specified and as directed.12Each
77S&F in replacement of MCB, Three Pole 40 to 63 Amps, C Curve Complete all as specified and as directed.32Each
88S&F MCB DB Double Door, SPN 8 way IP 54 protection, concealed in wall complete all as specified and as directed.8Each
99All as per item No.8 above, but SPN 4 way2Each
1010All as per item No.8 above, but SPN 12 way5Each
1111All as per item No.8 above, but TPN 04 way.\n\nNote for item No. 8 to 11:- The quoted rate shall be inclusive of the cost of dismantling of wall portion for concealing the DB and making good the disturbed portion to match with the existing finish complete.3Each
1212S&F in replacement MCCB 3 Pole, 125 Amps, 25kA in existing DB/ Panel with necessary extended copper terminals complete all as specified and as directed.2Each
1313S&F in replacement two pin and earth Metal clad plug and socket with MCB SP 20Amps, complete all as specified and as directed.10Each
1414S&F in replacement Single Module time switch, 24 hours program, Programmable every 15 min., backup of 100 hours, current capacity 16A, with 1 changeover complete all as specified and as directed.\n10Each
1515M&L in repair sub main wiring with two runs of single core 2.5 Sqmm (FRLS) multistranded copper conductor PVC unsheathed cable drawn through and including PVC conduit of not less than 25 mm dia concealed in wall/floor including cutting chasses and making good the wall/ceiling / floor or fixed to wall for sub main connection including 2.5 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly including taking down existing sub main wiring complete all as specified and directed. Note : Three runs of 2.5 Sqmm (FRLS) copper conductor and one run of PVC conduit shall be measured as one unit length). \n150RM
1616M&L for Earthing complete with earth galvanized steel plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with galvanized earth lead GI wire 4 mm dia by means of bolts, check nut and washers of GI or steel, GI pipe light grade of 15 mm bore as protection pipe, GI wire of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia light grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.20Each Set

AI Tender Summary

OUR REF NO 27950221
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 14-06-2021
Authority
Authority Name Military Engineer Services
Work Description Repairs Replacement Of Burnt Defective Mcb Db Mccb Bldg Earthing Pits And Other Misc Items At Af Stn Suryalanka As Per Boq And Tender Document
Basic Detail
Tender No AGE(I)/SL/8393
Bidding Type Tender
Location
City SURYALANKA
State Andhra Pradesh
Key Dates
Publish Date 08 Jun 2021
Submission Date 14 Jun 2021
Open Date 16 Jun 2021
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 12600
Exemption Not Available
Document List
Tendernotice_1.pdf
PS.pdf
DDA5D52F-1F76-416F-89F0-D8A9510D1F13.html
Tenderdoc.pdf
BOQ_495881.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 08, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 08, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 14, 2021
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 14, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 16, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

PS.pdf

html

DDA5D52F-1F76-416F-89F0-D8A9510D1F13.html

pdf

Tenderdoc.pdf

xls

BOQ_495881.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders