Power Government Departments Closing in 0 days TDR #27949984

Procurement Of Abb Make Electrical Spares.

Issued by Government Departments · , Karnataka
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Jun 2021
0 days left
EMD
1900
Bank guarantee accepted
Document Fee
550
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Procurement Of Abb Make Electrical Spares. 1. 3 Pole Ac Mccb,100A,690V,Abb Make: Abb Sace Version: Tmax T2s160 With Pr 221Ds Protection Module In: 100A, Cat: A Ue: 690V, Ui: 800V, Uimp: 8Kv 50/60Hz, Iec-60947-2, 2. Mcb-4 Pole, 32 A, 440 V Miniature Circuit Breaker,Rated Current:32Amps, No.Of Poles: 4 Pole, Rated Voltage: 415/440 Vac, Rated Frequency: 50Hz, Rated Short Circuit Breaking Capacity: 10Ka, Mounting: Clipon Din Rail (35X7.5Mm), Make: L&T,Seimens, Schneider., 3. Psu-14-2X 220V Dcrelay 7No+7Nc Hbb Make Psu-14-2X 220V Dc Relay 7No+7Nc, 4. Motor Protection Crkt Breaker Abb Ms116-4.0 2.5-4A, 1No +1Nc, 5. Motor Protection Crkt Breaker Abb Ms116-0.63 0.4-0.63,1No + 1Nc Model:Ms116-0.63, Range:0.4-0.63A , Ac-3,3P 50Ka, 415V ,Ip:20, 50Hz,Mtg:Din Rail Mounting, With 1No+1Nc Auxilary Contact Tm Based With O/L & S/C Release Make:Abb, 6. Trip Relay Type:Pq8nch2j, Abb Make High Speed Trip Relay,Type:Pq8nch2j, Aux. Voltage : 220V Dc, Contact:4No+3Nc H/R, Case Size:1/2 `S` Case, Mounting : Flush, Application:Master/Lockout Device., 7. Universal Timer - Nt10 Item: Universal Timer Relay Make: M/S Abb, Vadodara. Ordering Information : 1Myn569701-B Specification: Equivalent To Ssx90m6c2j Type: Nt10 Contacts: 1 No + 2 Co Auxiliary Voltage: 220V Dc Time Setting Range Required: 6-60Sec, 8. Mpcb Abb Make 6.3-10A Abb Make Mpcb Range 6.3-10A Cat No.Ms116-10 3Pole Model:Ms116-10 Range:6.3-10A 3P 50Ka, Ac-3 Mpcb 415V 50Hz,Ui:690V,Uimp:6Kv,Ip:20, Trip Class 10A, With 1No+1Nc Auxilary Contact(Model:Hk1-11) Tm Based With O/L & S/C Release ,Mtg: Din Rail Mounting, Make:Abb, 9. Mpcb Abb 4-6.3A Abb Make Mpcb Range 4-6.3A Cat No.Ms116-6.30 3Pole With Addon Block Hk1-11 1No,1Nc (Above Auxiliary Contact Mountable On Right Side) Make:Abb, 10. Abb Thermal Olr Model:Ta25du-Xm,Range:0.4-0.63A, Ui:690V,Ue:690V,Uimp:6Kv, Trip Class:10, Ip:20, Bimetallic Thermal Overload Relay With 1No+1Nc Aux Contacts With Suitable Mounting Kit Make:Abb, 11. Abb Thermal Overloadrelay 2.4A Abb Thermal Overload Relays 2.4A Abb Thermal Overload Relays For Ttr Of Chp-3 General Information Extended Product Type: Ta25du-2.4M Product Id: 1Saz211201r2028 Ean: 4013614482489 Catalog Description: Ta25du-2.4M Thermal Overload Relays Technical Setting Range: 1.70 ... 2.40 A Voltage: 440/500 V Ac/Dc, Main Circuit 690 V Ac, Current : 2.4 A, Frequency (F): 50 Hz, Rated Impulse Withstand Voltage (U ): 6 Kv, Rated Insulation Voltage (U ): 690 V, Number Of Poles: 3, Number Of Auxiliary Contacts Nc: 1, No: 1 Degree Of Protection: Housing Ip20, Main Circuit Terminals Ip10, 12. Abb Thermal Overload Relay 19A Abb Thermal Overload Relays 19.0A Abb Thermal Overload Relays For Ttr Of Chp-3 General Information Extended Product Type: Ta25du-19M Product Id: 1Saz211201r2047 Ean: 4013614482564 Catalog Description: Ta25du-19M Thermal Overload Relays. Technical Setting Range: 13.0 ... 19.0 A Voltage: 440/500 V Ac/Dc, Main Circuit 690 V Ac, Current : 19 A, Frequency (F): 50 Hz, Rated Impulse Withstand Voltage (U ): 6 Kv, Rated Insulation Voltage (U ): 690 V, Number Of Poles: 3, Number Of Auxiliary Contacts Nc: 1, No: 1 Degree Of Protection: Housing Ip20, Main Circuit Terminals Ip10, 13. Mpcb 20A (Manual Motor Starter Mpcb 20A (Manual Motor Starter) Motor Protection Circuit Breaker For Ttr Chp-3 Make : Abb, Setting Range : 16.0...20.0A, Type : Ms132-20, Trip Class : 20A Order Code : 1Sam350000r1013 Order Data : Ms132 Screw Terminal Rated Operational Voltage Ue : 690 V Ac / 250 V Dc Rated Operational Current Le : 20.0 Rated Instantaneous Short-Circuit Current Setting Li : 300A Rated Frequency : Dc, 50/60 Hz Number Of Poles : 3 Rated Impulse Withstand Voltage Uimp : 6Kv Note : The Proposed Item Shall Match All Electrical Parameters, Terminal Connection, Mounting Arrangements & All Other Dimensions Of Existing Mpcb., 14. Sk1-11 Single Contact Sk1-11 Single Contact Manual Motor Starter Accessories/Motor Protection Circuit Breaker Auxiliary Contact Suitable For Abb Manual Motor Starter(Mpcb)(Type:Ms132-20)Of Ttr Chp-3 Make:Abb Extended Product Type:Sk1-11 Product Id:1Sam201903r1001 Ean: 4013614320392 Catalog Description: Sk1-11 Signal Contact Technical Rated Operational Voltage: 690 V Ac, 600 V Dc, Main Circuit 690 V Rated Operational Current Ac-15(I):(240 V) 4A, (24 V) 6A, (380/400 V) 3A, (690V) 1A Rated Operational Current Dc-13(I):(125 V) 0.55A, (24V) 2A, (250V) 0.27A, (440V) 0A, (600 V) 0A Rated Impulse Withstand Voltage (U ): Auxiliary Circuit 6Kv Rated Insulation Voltage (U):690 V Degree Of Protection: Ip20 Number Of Auxiliary Contacts No: 1 Number Of Auxiliary Contacts Nc: 1 Standards: Iec/En 60947-1, Iec/En 60947- 5-1, Ul 60947-1, Ul 60947-4-1, Ul 508, Csa 22.2 No.14, 15. Hk1-11 Single Contact Hk1-11 Single Contact Manual Motor Starter Accessories/Motor Protection Circuit Breaker Auxiliary Contact Suitable For Abb Manual Motor Starter (Type : Ms132-20) Of Ttr Chp-3 Make : Abb Extended Product Type: Hk1-11 Product Id: 1Sam201902r1001 Ean: 4013614320361 Catalog Description: Hk1-11 Auxiliary Contact Technical Rated Operational Voltage: 690 Vac, 600 Vdc, Main Circuit 690V Rated Operational Current Ac-15 (I):(240V) 4 A, (24 V) 6A, (380/400V) 3A, (690 V) 1A Rated Operational Current Dc-13 (I):(125V) 0.55A, (24V) 2A, (250V) 0.27A, (440V) 0A, (600V) 0A Rated Impulse Withstand Voltage (U):Auxiliary Circuit 6 Kv Rated Insulation Voltage (U):690 V Degree Of Protection: Ip20 Number Of Auxiliary Contacts No/Nc/Co(Spdt): 1/1/0 Standards: Iec/En 60947-1, Iec/En 60947- 5-1, Ul 60947-1, Ul 60947-5-1, Ul Csa 22.2 No. 14, 16. Abb Mpcb Ms116-2.5 Model: Ms 116,1.6-2.5A, Ac-3, Trip Class: 10A, 3P 50Ka, Mpcb 415V 50Hz, Din Rail Mounting, Tm Based With O/L & S/C Release, 1No+1Nc Auxilary Contact(Model:Hk1- 11), Make:Abb, 17. Abb Mpcb Ms132-16 Model:Ms132 10-16A Ac-3, Trip Class: 10A, 3P 50Ka, Mpcb 415V 50Hz, Din Rail Mounting, Tm Based With O/L & S/C Release, 1No+1Nc Auxilary Contact(Model:Hk1- 11), Make:Abb, 18. Abb Olr, Range : 1.7A - 2.4A Abb Make Thermal Over Load Relay, Type-T25du2.4, Tange : 1.7A - 2.4A With 1No+1Nc Aux. Contacts, 19. Abb Olr, Range : 10A - 14A Abb Make Thermal Over Load Relay, Type- T25du14, Range : 10A - 14A With 1No+ 1Nc Aux. Contacts., 20. Abb Olr, Range : 2.8A - 4A Abb Make Thermal Over Load Relay, Type : T25du4, Range : 2.8A - 4A With 1No+1Nc Aux. Contacts, 21. 825350718R Abb Olr, Range : 4.5A - 6.5A Abb Make Thermal Over Load Relay, Type- T25du6.5, Range : 4.5A - 6.5A With 1No+1Nc Aux. Contacts., 22. Abb Olr, Range : 7.5A - 11A Abb Make Thermal Over Load Relay, Type T25du11, Range : 7.5A - 11A With 1No+1Nc Aux. Contacts.,

BOQ

Sl No Item Code Item Name Item Description Unit Quantity
1
144803189V 3 POLE AC MCCB,100A,690V,ABB MAKE: ABB SACE Version: Tmax T2S160 with PR 221DS Protection module In: 100A, CAT: A Ue: 690V, Ui: 800V, Uimp: 8KV 50/60Hz, IEC-60947-2
Nos
1
2
144804139V MCB-4 POLE, 32 A, 440 V Miniature Circuit Breaker,Rated Current:32Amps, No.of Poles: 4 Pole, Rated Voltage: 415/440 VAC, Rated frequency: 50Hz, Rated Short Circuit Breaking Capacity: 10kA, Mounting: Clipon DIN rail (35x7.5mm), Make: L&T,Seimens, Schneider.
Nos
2
3
561010204R PSU-14-2X 220V DCRELAY 7NO+7NC HBB MAKE PSU-14-2X 220V DC RELAY 7NO+7NC
Nos
1
4
571140215B MOTOR PROTECTION CRKT BREAKER ABB MS116-4.0 2.5-4A, 1NO +1NC
Nos
6
5
571140216B MOTOR PROTECTION CRKT BREAKER ABB MS116-0.63 0.4-0.63,1NO + 1NC MODEL:MS116-0.63, RANGE:0.4-0.63A , AC-3,3P 50kA, 415V ,IP:20, 50Hz,MTG:DIN RAIL MOUNTING, with 1NO+1NC auxilary Contact TM based with O/L & S/C Release MAKE:ABB
Nos
2
6
6900110039 TRIP RELAY TYPE:PQ8NCH2J, ABB MAKE HIGH SPEED TRIP RELAY,Type:PQ8NCH2J, AUX. VOLTAGE : 220V DC, CONTACT:4NO+3NC H/R, CASE SIZE:1/2 `S` CASE, MOUNTING : FLUSH, APPLICATION:MASTER/LOCKOUT DEVICE.
Nos
2
7
691301728R UNIVERSAL TIMER - NT10 ITEM: UNIVERSAL TIMER RELAY MAKE: M/S ABB, VADODARA. ORDERING INFORMATION : 1MYN569701-B SPECIFICATION: EQUIVALENT TO SSX90M6C2J TYPE: NT10 CONTACTS: 1 NO + 2 CO AUXILIARY VOLTAGE: 220V DC TIME SETTING RANGE REQUIRED: 6-60Sec
Nos
1
8
821603900B MPCB ABB MAKE 6.3-10A ABB Make MPCB range 6.3-10A Cat No.MS116-10 3pole MODEL:MS116-10 RANGE:6.3-10A 3P 50kA, AC-3 MPCB 415V 50Hz,Ui:690V,Uimp:6KV,IP:20, TRIP CLASS 10A, WITH 1NO+1NC auxilary Contact(MODEL:HK1-11) TM based with O/L & S/C Release ,MTG: DIN RAIL MOUNTING, MAKE:ABB
Nos
2
9
821604000B MPCB ABB 4-6.3A ABB Make MPCB range 4-6.3A Cat No.MS116-6.30 3pole WITH ADDON BLOCK HK1-11 1NO,1NC (Above Auxiliary contact mountable on right side) MAKE:ABB
Nos
6
10
8233507033 ABB THERMAL OLR MODEL:TA25DU-Xm,Range:0.4-0.63A, Ui:690V,Ue:690V,Uimp:6KV, Trip Class:10, IP:20, Bimetallic thermal Overload relay with 1NO+1NC aux contacts with suitable mounting kit MAKE:ABB
Nos
2
11
823350705B ABB THERMAL OVERLOADRELAY 2.4A ABB THERMAL OVERLOAD RELAYS 2.4A ABB Thermal Overload Relays for TTR of CHP-3 General Information Extended Product Type: TA25DU-2.4M Product ID: 1SAZ211201R2028 EAN: 4013614482489 Catalog Description: TA25DU-2.4M Thermal Overload Relays Technical Setting Range: 1.70 ... 2.40 A Voltage: 440/500 V AC/DC, Main Circuit 690 V AC, Current : 2.4 A, Frequency (f): 50 Hz, Rated Impulse Withstand Voltage (U ): 6 kV, Rated Insulation Voltage (U ): 690 V, Number of Poles: 3, Number of Auxiliary Contacts NC: 1, NO: 1 Degree of Protection: Housing IP20, Main Circuit Terminals IP10
Nos
1
12
823350710B ABB THERMAL OVERLOAD RELAY 19A ABB THERMAL OVERLOAD RELAYS 19.0A ABB Thermal Overload Relays for TTR of CHP-3 General Information Extended Product Type: TA25DU-19M Product ID: 1SAZ211201R2047 EAN: 4013614482564 Catalog Description: TA25DU-19M Thermal Overload Relays. Technical Setting Range: 13.0 ... 19.0 A Voltage: 440/500 V AC/DC, Main Circuit 690 V AC, Current : 19 A, Frequency (f): 50 Hz, Rated Impulse Withstand Voltage (U ): 6 kV, Rated Insulation Voltage (U ): 690 V, Number of Poles: 3, Number of Auxiliary Contacts NC: 1, NO: 1 Degree of Protection: Housing IP20, Main Circuit Terminals IP10
Nos
6
13
823600100B MPCB 20A (MANUAL MOTOR STARTER MPCB 20A (MANUAL MOTOR STARTER) MOTOR PROTECTION CIRCUIT BREAKER for TTR CHP-3 Make : ABB, Setting range : 16.0...20.0A, Type : MS132-20, Trip class : 20A Order code : 1SAM350000R1013 Order data : MS132 Screw Terminal Rated operational voltage Ue : 690 V AC / 250 V DC Rated operational current le : 20.0 Rated instantaneous short-circuit current setting li : 300A Rated frequency : DC, 50/60 Hz Number of poles : 3 Rated impulse withstand voltage Uimp : 6kV Note : The proposed item shall match all electrical parameters, terminal connection, mounting arrangements & all other dimensions of existing MPCB.
Nos
5
14
823600101B SK1-11 SINGLE CONTACT SK1-11 SINGLE CONTACT MANUAL MOTOR STARTER ACCESSORIES/MOTOR PROTECTION CIRCUIT BREAKER AUXILIARY CONTACT suitable for ABB Manual Motor Starter(MPCB)(Type:MS132-20)of TTR CHP-3 Make:ABB Extended Product Type:SK1-11 Product ID:1SAM201903R1001 EAN: 4013614320392 Catalog Description: SK1-11 Signal Contact Technical Rated Operational Voltage: 690 V AC, 600 V DC, Main Circuit 690 V Rated Operational Current AC-15(I):(240 V) 4A, (24 V) 6A, (380/400 V) 3A, (690V) 1A Rated Operational Current DC-13(I):(125 V) 0.55A, (24V) 2A, (250V) 0.27A, (440V) 0A, (600 V) 0A Rated Impulse Withstand Voltage (U ): Auxiliary Circuit 6kV Rated Insulation Voltage (U):690 V Degree of Protection: IP20 Number of Auxiliary Contacts NO: 1 Number of Auxiliary Contacts NC: 1 Standards: IEC/EN 60947-1, IEC/EN 60947- 5-1, UL 60947-1, UL 60947-4-1, UL 508, CSA 22.2 No.14
Nos
4
15
823600102B HK1-11 SINGLE CONTACT HK1-11 SINGLE CONTACT MANUAL MOTOR STARTER ACCESSORIES/MOTOR PROTECTION CIRCUIT BREAKER AUXILIARY CONTACT suitable for ABB Manual Motor Starter (Type : MS132-20) of TTR CHP-3 Make : ABB Extended Product Type: HK1-11 Product ID: 1SAM201902R1001 EAN: 4013614320361 Catalog Description: HK1-11 Auxiliary Contact Technical Rated Operational Voltage: 690 VAC, 600 VDC, Main Circuit 690V Rated Operational Current AC-15 (I):(240V) 4 A, (24 V) 6A, (380/400V) 3A, (690 V) 1A Rated Operational Current DC-13 (I):(125V) 0.55A, (24V) 2A, (250V) 0.27A, (440V) 0A, (600V) 0A Rated Impulse Withstand Voltage (U):Auxiliary Circuit 6 kV Rated Insulation Voltage (U):690 V Degree of Protection: IP20 Number of Auxiliary Contacts NO/NC/CO(SPDT): 1/1/0 Standards: IEC/EN 60947-1, IEC/EN 60947- 5-1, UL 60947-1, UL 60947-5-1, UL CSA 22.2 No. 14
Nos
6
16
8239012249 ABB MPCB MS116-2.5 Model: MS 116,1.6-2.5A, AC-3, Trip Class: 10A, 3P 50kA, MPCB 415V 50Hz, DIN RAIL MOUNTING, TM based with O/L & S/C Release, 1NO+1NC auxilary Contact(MODEL:HK1- 11), MAKE:ABB
Nos
6
17
8239012257 ABB MPCB MS132-16 MODEL:MS132 10-16A AC-3, Trip Class: 10A, 3P 50kA, MPCB 415V 50Hz, DIN RAIL MOUNTING, TM based with O/L & S/C Release, 1NO+1NC auxilary Contact(MODEL:HK1- 11), MAKE:ABB
Nos
2
18
825350705R ABB OLR, RANGE : 1.7A - 2.4A ABB MAKE THERMAL OVER LOAD RELAY, TYPE-T25DU2.4, TANGE : 1.7A - 2.4A WITH 1NO+1NC AUX. CONTACTS
Nos
6
19
825350706R ABB OLR, RANGE : 10A - 14A ABB MAKE THERMAL OVER LOAD RELAY, TYPE- T25DU14, RANGE : 10A - 14A WITH 1NO+ 1NC AUX. CONTACTS.
Nos
2
20
825350714R ABB OLR, RANGE : 2.8A - 4A ABB MAKE THERMAL OVER LOAD RELAY, TYPE : T25DU4, RANGE : 2.8A - 4A with 1NO+1NC aux. contacts
Nos
8
21
825350718R 825350718R ABB OLR, RANGE : 4.5A - 6.5A ABB MAKE THERMAL OVER LOAD RELAY, TYPE- T25DU6.5, RANGE : 4.5A - 6.5A WITH 1NO+1NC AUX. CONTACTS.
Nos
8
22
825350723R ABB OLR, RANGE : 7.5A - 11A ABB MAKE THERMAL OVER LOAD RELAY, TYPE T25DU11, RANGE : 7.5A - 11A WITH 1NO+1NC AUX. CONTACTS.
Nos
2

AI Tender Summary

OUR REF NO 27949984
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 07-06-2021
Authority
Authority Name Karnataka Power Corporation Limited
Work Description Procurement Of Abb Make Electrical Spares. 1. 3 Pole Ac Mccb,100A,690V,Abb Make: Abb Sace Version: Tmax T2s160 With Pr 221Ds Protection Module In: 100A, Cat: A Ue: 690V, Ui: 800V, Uimp: 8Kv 50/60Hz, Iec-60947-2, 2. Mcb-4 Pole, 32 A, 440 V Miniature Circuit Breaker,Rated Current:32Amps, No.Of Poles: 4 Pole, Rated Voltage: 415/440 Vac, Rated Frequency: 50Hz, Rated Short Circuit Breaking Capacity: 10Ka, Mounting: Clipon Din Rail (35X7.5Mm), Make: L&T,Seimens, Schneider., 3. Psu-14-2X 220V Dcrelay 7No+7Nc Hbb Make Psu-14-2X 220V Dc Relay 7No+7Nc, 4. Motor Protection Crkt Breaker Abb Ms116-4.0 2.5-4A, 1No +1Nc, 5. Motor Protection Crkt Breaker Abb Ms116-0.63 0.4-0.63,1No + 1Nc Model:Ms116-0.63, Range:0.4-0.63A , Ac-3,3P 50Ka, 415V ,Ip:20, 50Hz,Mtg:Din Rail Mounting, With 1No+1Nc Auxilary Contact Tm Based With O/L & S/C Release Make:Abb, 6. Trip Relay Type:Pq8nch2j, Abb Make High Speed Trip Relay,Type:Pq8nch2j, Aux. Voltage : 220V Dc, Contact:4No+3Nc H/R, Case Size:1/2 `S` Case, Mounting : Flush, Application:Master/Lockout Device., 7. Universal Timer - Nt10 Item: Universal Timer Relay Make: M/S Abb, Vadodara. Ordering Information : 1Myn569701-B Specification: Equivalent To Ssx90m6c2j Type: Nt10 Contacts: 1 No + 2 Co Auxiliary Voltage: 220V Dc Time Setting Range Required: 6-60Sec, 8. Mpcb Abb Make 6.3-10A Abb Make Mpcb Range 6.3-10A Cat No.Ms116-10 3Pole Model:Ms116-10 Range:6.3-10A 3P 50Ka, Ac-3 Mpcb 415V 50Hz,Ui:690V,Uimp:6Kv,Ip:20, Trip Class 10A, With 1No+1Nc Auxilary Contact(Model:Hk1-11) Tm Based With O/L & S/C Release ,Mtg: Din Rail Mounting, Make:Abb, 9. Mpcb Abb 4-6.3A Abb Make Mpcb Range 4-6.3A Cat No.Ms116-6.30 3Pole With Addon Block Hk1-11 1No,1Nc (Above Auxiliary Contact Mountable On Right Side) Make:Abb, 10. Abb Thermal Olr Model:Ta25du-Xm,Range:0.4-0.63A, Ui:690V,Ue:690V,Uimp:6Kv, Trip Class:10, Ip:20, Bimetallic Thermal Overload Relay With 1No+1Nc Aux Contacts With Suitable Mounting Kit Make:Abb, 11. Abb Thermal Overloadrelay 2.4A Abb Thermal Overload Relays 2.4A Abb Thermal Overload Relays For Ttr Of Chp-3 General Information Extended Product Type: Ta25du-2.4M Product Id: 1Saz211201r2028 Ean: 4013614482489 Catalog Description: Ta25du-2.4M Thermal Overload Relays Technical Setting Range: 1.70 ... 2.40 A Voltage: 440/500 V Ac/Dc, Main Circuit 690 V Ac, Current : 2.4 A, Frequency (F): 50 Hz, Rated Impulse Withstand Voltage (U ): 6 Kv, Rated Insulation Voltage (U ): 690 V, Number Of Poles: 3, Number Of Auxiliary Contacts Nc: 1, No: 1 Degree Of Protection: Housing Ip20, Main Circuit Terminals Ip10, 12. Abb Thermal Overload Relay 19A Abb Thermal Overload Relays 19.0A Abb Thermal Overload Relays For Ttr Of Chp-3 General Information Extended Product Type: Ta25du-19M Product Id: 1Saz211201r2047 Ean: 4013614482564 Catalog Description: Ta25du-19M Thermal Overload Relays. Technical Setting Range: 13.0 ... 19.0 A Voltage: 440/500 V Ac/Dc, Main Circuit 690 V Ac, Current : 19 A, Frequency (F): 50 Hz, Rated Impulse Withstand Voltage (U ): 6 Kv, Rated Insulation Voltage (U ): 690 V, Number Of Poles: 3, Number Of Auxiliary Contacts Nc: 1, No: 1 Degree Of Protection: Housing Ip20, Main Circuit Terminals Ip10, 13. Mpcb 20A (Manual Motor Starter Mpcb 20A (Manual Motor Starter) Motor Protection Circuit Breaker For Ttr Chp-3 Make : Abb, Setting Range : 16.0...20.0A, Type : Ms132-20, Trip Class : 20A Order Code : 1Sam350000r1013 Order Data : Ms132 Screw Terminal Rated Operational Voltage Ue : 690 V Ac / 250 V Dc Rated Operational Current Le : 20.0 Rated Instantaneous Short-Circuit Current Setting Li : 300A Rated Frequency : Dc, 50/60 Hz Number Of Poles : 3 Rated Impulse Withstand Voltage Uimp : 6Kv Note : The Proposed Item Shall Match All Electrical Parameters, Terminal Connection, Mounting Arrangements & All Other Dimensions Of Existing Mpcb., 14. Sk1-11 Single Contact Sk1-11 Single Contact Manual Motor Starter Accessories/Motor Protection Circuit Breaker Auxiliary Contact Suitable For Abb Manual Motor Starter(Mpcb)(Type:Ms132-20)Of Ttr Chp-3 Make:Abb Extended Product Type:Sk1-11 Product Id:1Sam201903r1001 Ean: 4013614320392 Catalog Description: Sk1-11 Signal Contact Technical Rated Operational Voltage: 690 V Ac, 600 V Dc, Main Circuit 690 V Rated Operational Current Ac-15(I):(240 V) 4A, (24 V) 6A, (380/400 V) 3A, (690V) 1A Rated Operational Current Dc-13(I):(125 V) 0.55A, (24V) 2A, (250V) 0.27A, (440V) 0A, (600 V) 0A Rated Impulse Withstand Voltage (U ): Auxiliary Circuit 6Kv Rated Insulation Voltage (U):690 V Degree Of Protection: Ip20 Number Of Auxiliary Contacts No: 1 Number Of Auxiliary Contacts Nc: 1 Standards: Iec/En 60947-1, Iec/En 60947- 5-1, Ul 60947-1, Ul 60947-4-1, Ul 508, Csa 22.2 No.14, 15. Hk1-11 Single Contact Hk1-11 Single Contact Manual Motor Starter Accessories/Motor Protection Circuit Breaker Auxiliary Contact Suitable For Abb Manual Motor Starter (Type : Ms132-20) Of Ttr Chp-3 Make : Abb Extended Product Type: Hk1-11 Product Id: 1Sam201902r1001 Ean: 4013614320361 Catalog Description: Hk1-11 Auxiliary Contact Technical Rated Operational Voltage: 690 Vac, 600 Vdc, Main Circuit 690V Rated Operational Current Ac-15 (I):(240V) 4 A, (24 V) 6A, (380/400V) 3A, (690 V) 1A Rated Operational Current Dc-13 (I):(125V) 0.55A, (24V) 2A, (250V) 0.27A, (440V) 0A, (600V) 0A Rated Impulse Withstand Voltage (U):Auxiliary Circuit 6 Kv Rated Insulation Voltage (U):690 V Degree Of Protection: Ip20 Number Of Auxiliary Contacts No/Nc/Co(Spdt): 1/1/0 Standards: Iec/En 60947-1, Iec/En 60947- 5-1, Ul 60947-1, Ul 60947-5-1, Ul Csa 22.2 No. 14, 16. Abb Mpcb Ms116-2.5 Model: Ms 116,1.6-2.5A, Ac-3, Trip Class: 10A, 3P 50Ka, Mpcb 415V 50Hz, Din Rail Mounting, Tm Based With O/L & S/C Release, 1No+1Nc Auxilary Contact(Model:Hk1- 11), Make:Abb, 17. Abb Mpcb Ms132-16 Model:Ms132 10-16A Ac-3, Trip Class: 10A, 3P 50Ka, Mpcb 415V 50Hz, Din Rail Mounting, Tm Based With O/L & S/C Release, 1No+1Nc Auxilary Contact(Model:Hk1- 11), Make:Abb, 18. Abb Olr, Range : 1.7A - 2.4A Abb Make Thermal Over Load Relay, Type-T25du2.4, Tange : 1.7A - 2.4A With 1No+1Nc Aux. Contacts, 19. Abb Olr, Range : 10A - 14A Abb Make Thermal Over Load Relay, Type- T25du14, Range : 10A - 14A With 1No+ 1Nc Aux. Contacts., 20. Abb Olr, Range : 2.8A - 4A Abb Make Thermal Over Load Relay, Type : T25du4, Range : 2.8A - 4A With 1No+1Nc Aux. Contacts, 21. 825350718R Abb Olr, Range : 4.5A - 6.5A Abb Make Thermal Over Load Relay, Type- T25du6.5, Range : 4.5A - 6.5A With 1No+1Nc Aux. Contacts., 22. Abb Olr, Range : 7.5A - 11A Abb Make Thermal Over Load Relay, Type T25du11, Range : 7.5A - 11A With 1No+1Nc Aux. Contacts.,
Basic Detail
Tender No KPCL/2021-22/IND4204
Bidding Type Tender
Location
City
State Karnataka
Key Dates
Publish Date 21 May 2021
Submission Date 07 Jun 2021
Open Date 09 Jun 2021
Finance
Tender Value Ref. Documents
Tender Fee 550
EMD 1900
Exemption Not Available
Document List
750f5bfe-56b9-4ab7-a314-d63a7c4a12ad.html
latest tender book new gst.doc
technical specification.doc
e-portal declaration.docx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 21, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 07, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 09, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

750f5bfe-56b9-4ab7-a314-d63a7c4a12ad.html

doc

latest tender book new gst.doc

doc

technical specification.doc

docx

e-portal declaration.docx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders