| 1 | 1 | Capex Cost of Sound and Light Show at Jhansi Fort in Jhansi City. | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1.01 | Supply, Installation, Testing and Commissioning Equipment Rack 42 U Steel Doors – plain, vented at bottom, fully perforated and dual perforated, Glass Doors – with optional vented side trims for front-to-back air flow | BI01010001010000000000000515BI0100001113 | 1 | Nos. |
|---|
| 3 | 1.02 | Supply, Installation, Testing and Commissioning of Flying, arrayble Full Size dual 15\" weatherised subwoofer element. The subwoofer must have frequency range of 32Hz-100Hz(-10dB), sensitivity (1W/1m)97dB SPL or more, delivering Max SPL of 132dB or more with power handling peak of 4000W or less. The speaker should have a nominal impedance of 4 O | BI01010001010000000000000515BI0100001114 | 4 | Nos. |
|---|
| 4 | 1.03 | Supply, Installation, Testing and Commissioningof Dual 10\" – 15” Two-Way Line Array IP 55 rated or better Speaker with a Frequency Range(-10dB): -50-20kHz & Long Term Power Handling of = 600W (at a Nominal Impedance of 4/ 8 Ohms). The Loudspeaker should have a Sensitivity(1W/1m) Max. SPL of >=130dB. The (HXV) Coverage of Speaker should be 60Degrees or better. | BI01010001010000000000000515BI0100001115 | 12 | Nos. |
|---|
| 5 | 1.04 | Supply, Installation, Testing and Commissioning Supply of Corded Vocal Microphone with Dynamic neodymium magnet based microphone element with frequency response of 32Hz-17kHz or better ,Cardioid polar pattern, sensitivity of = 2.3 mV/Pa ,Dynamic Range > 140 dB, rated impedance of 350 ohm | BI01010001010000000000000515BI0100001116 | 2 | Nos. |
|---|
| 6 | 1.05 | Supply, Installation, Testing and Commissioning of multi channel class D/H Power amplifier with built in Audio Digital Signal Processor, a Maximum Output Power = 900W@8 ohms, = 1750W@4 Ohms for single channel operation; Max Bridged Output Power = 5500W @ 4 ohms,Frequency Response (+/- 1dB) ref. 1 KHz:15Hz - 20 KHz,Max input level:+21dBu,Crosstalk< - 80dB,input impedence:20kohm,signal to noise ratio >109 dB,with built in Digital Signal processor. | BI01010001010000000000000515BI0100001117 | 8 | Nos. |
|---|
| 7 | 1.06 | Supply, Installation, Testing and Commissioning of 16 channel Compact Mixing System (12 x Mic/Line + 4 x Mic/Stereo-Line), Auxiliarys (MON, FX, AUX) : 2 Pre, 2 Post, 2 Pre/Post switchable, Frequency Response, -3 dB, ref. 1 kHz : 15 Hz to 65 kHz, Crosstalk, 1 kHz Channel to Channel < -80 dB, THD at 1 kHz < 0.005%, CMRR MIC input 1 kHz > 80 dB, Dual stereo 24/48-bit multi effects processors | BI01010001010000000000000515BI0100001118 | 1 | Nos. |
|---|
| 8 | 1.07 | Supplying, Installation, Testing and commissioning of USB audio interface / Internal Sound Card with studio-quality sound | BI01010001010000000000000515BI0100001119 | 1 | Nos. |
|---|
| 9 | 1.08 | 3-Chip DLP or better Laser projector with complete dust protection as per IP60 standards/sealed DLP core, Min. 30,000 ANSI/ISO Lumens or brighter, Laser light source having 25000-30000 hrs. life, 4K Native display resolution or better, Contrast ratio(Native) min. 5000:1 or better, HDR Supported, 24/7 operation ,PC 3D ready ,Anamorphic ally ready, Filter less operation with liquid cooled technology, Inputs: Display port, , HDMI, HDBaseT, 3G-SDI in/out Controls: 3D sync in/out, LAN,RS-232,AMX,DMX Art-Net along with suitable long throw lens. | BI01010001010000000000000515BI0100001120 | 8 | Nos. |
|---|
| 10 | 1.09 | Projection housing enclosure with DEC Control Interface for setup and monitoring of temperature, humidity and status indicators. Power control circuit with PID Management system compatible with the projection housing unit and display unit. | BI01010001010000000000000515BI0100001121 | 8 | Nos. |
|---|
| 11 | 1.1 | Supplying, Installation, Testing and commissioning of 10-Watt RGB Laser System. | | 10 | Nos. |
|---|
| 12 | 1.11 | Laser housing enclosure with DEC Control Interface for setup and monitoring of temperature, humidity and status indicators. Power control circuit with PID Management system compatible with the projection housing unit and display unit. | BI01010001010000000000000515BI0100001123 | 10 | Nos. |
|---|
| 13 | 1.12 | Supplying, Installation, Testing and commissioning of Laser show programming and control software. | BI01010001010000000000000515BI0100001124 | 1 | Nos. |
|---|
| 14 | 1.13 | Assembly and mounting of projector as per site plan with cables, mounting brackets and tilt/pan arrangement systems for projection layout. | | 1 | Lot |
|---|
| 15 | 1.14 | SITC of LED moving Head Light\nLight source: 300w; Angle:3° -30°; Max..Power:400w; Display On board control, Custom mode,0-25 Hz Strobe; Pan/Tilt rotation:540°/270°(8-16bit); Rotating Gobo:8 Gobos+ White,Gobo-flow effect, Gobo- shake, Bi-directional rotation; Static Gobo:12gobos+white,Gobo ; Colors: CMY wheel one color wheel; Animation Wheel: Bi-directional rotation, speed adjustable; Focus: Motorized linear focus | | 20 | Nos. |
|---|
| 16 | 1.15 | Media Player and Programming software should support video mapping, projection mapping, 3D mapping | | 8 | Nos. |
|---|
| 17 | 1.16 | Supplying, Installation, Testing and commissioning of Media Management Software | | 1 | Nos. |
|---|
| 18 | 1.17 | Supplying, Installation, Testing and commissioning of Show Control Software | | 1 | Nos. |
|---|
| 19 | 1.18 | Supplying, Installation, Testing and commissioning of DMX splitter | | 3 | Nos. |
|---|
| 20 | 1.19 | SITC of Workstation with intel Xeon processor with Intel Mainboard/Intel chipset motherboard.SSD Hard drive 500 gb( 2 nos.) for Raid 1. Nvidia GTX 950 – GTX 970 graphic card. 16 GB RAM Tower cabinet with 750 PSU with 750 PSU ,DVDdrive.Windows 7/8.1 Professional 64 bit. | | 2 | Nos. |
|---|
| 21 | 1.2 | Supply, Installation, Testing and Commissioning of 4 Output Server with following specifications: - Intel xeon E5-2620v4 Haswell-E 6-Core 2.40GHz LGA 2011- CPU 15Mb cache, Asus Z10PE - D16 Intel C- 612Chipset Original Motherboard, Kingston 32Gb (8 GBx 4 Nos.) ecc-regd DDR4 DRAM 2133MHz Memory, Intel Cpu Cooler, Coolermaster 850wt smps ( V850 ), Prime sorce Rm-4002 Rack Mount Chessis 4U Rack, Nvidia Quadro M-4000 16Gb DDR-5, 120Gb SSD Intel 535 Series, 500Gb x 2 SSD Samsung 850Evo (for RAID 1), DVD drive, Window 7 Professional 64 Bit, 24” 1920 x 1200 pixels TFT Dell Monitor, USB Keyboard and Mouse. Complete as required. | | 3 | Nos. |
|---|
| 22 | 1.21 | 24 inches Flat LCD Display Monitors with Optimal Resolution of 1920 x 1080 at 60 Hz having Brightness 250 cd/m² (typical). | | 2 | Nos. |
|---|
| 23 | 1.22 | Supply, installation testing and commissioning 60 KVA UPS, true on- line UPS 3 Ph double Conversion with all safeties and protection and suitable capacity sealed maintenance free 12 V batterie with a 30 mins backup time on full load with M open MS Battery rack and cable with paralleling kit | | 2 | Nos. |
|---|
| 24 | 1.23 | Supply, installation testing and commissioning Small Business 24 port Gigabit switch and 2 x Mini GBIC fiber Uplinks. | | 1 | Nos. |
|---|
| 25 | 1.24 | Supply, laying and termination of DVI D copper cables with ends duly terminated. | | 24 | Nos. |
|---|
| 26 | 1.25 | DP/HDMI/DVI range extender Tx – RX set over Single FO/CAT 6. Suitable for UDH 4K bandwidth of 3840x2160 as per site requirement. | | 8 | Nos. |
|---|
| 27 | 1.26 | Fibre optic cable with required accessories | | 1 | Lot |
|---|
| 28 | 1.27 | Cat6 twisted unshielded pair cable. | | 1 | Lot |
|---|
| 29 | 1.28 | Electrical panel, Power cabling and other electrical accessories with ISI Standard | | 1 | Lot |
|---|
| 30 | 1.29 | Air conditioner Portable/Fixed AV Control Room with minimum Two operator Seating Capacity | | 1 | Lot |
|---|
| 31 | 1.3 | Seating System for 250 Audience | | 1 | Lot |
|---|
| 32 | 1.31 | Remote device monitoring Panel for temperature, humidity etc. | | 1 | Lot |
|---|
| 33 | 1.32 | Surge Protection System | | 2 | Nos. |
|---|
| 34 | 1.33 | 200KVA Servo Voltage stabilizer | | 1 | Nos. |
|---|
| 35 | 1.34 | 200 KVA DG Set | | 1 | Nos. |
|---|
| 36 | 1.35 | All Audio ,video,DMX Cables and Connectors | | 1 | Lot |
|---|
| 37 | 1.36 | 30 Min AV Content Creation including, research, original music creation with 2D/3D animation, voice over in two languages (Hindi& English) using existing script | | 1 | Lot |
|---|
| 38 | 1.37 | Any other Hardware or Software required to meet the RFP requirements (Bidder to list individual items and provide costing). | | 1 | Nos. |
|---|
| 39 | 2.01 | Cost of Operation and Maintenance for 5 years | BI01010001010000000000000515BI0100001130 | 5 | Nos. |
|---|