Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #27937685

Repair Replacement Of Internal Wiring Fittings Fixtures At Meghadripeta Ashoka Park Pallava Park Namac Ctw Nsb Area Under Age Em Of Ge Nd Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatnam, Andhra Pradesh
Tender Value
40 Lakhs
Estimated cost
Bid Submission
09 Jun 2021
0 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatnam → Andhra Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair Replacement Of Internal Wiring Fittings Fixtures At Meghadripeta Ashoka Park Pallava Park Namac Ctw Nsb Area Under Age Em Of Ge Nd Visakhapatnam

BOQ

Name of Work: REPAIR / REPLACEMENT OF INTERNAL WIRING, FITTINGS, FIXTURES AT MEGHADRIPETA, ASHOKA PARK, PALLAVA PARK, NAMAC, CTW, NSB AREA UNDER AGE E/M OF GE[ND] VISAKHAPATNAM
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11The rates quoted by the tenderer shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:-\n[i] The repairs shall be done by skilled workmen in the relevant field to the entire satisfaction of Engineer-in-Charge. The contractor shall engage sufficient manpower for the entire period so that progress of work shall not be hampered due to non availability of labour at any time.\n[ii] The contractor on getting information through Site order / Works diary regarding the nature of repair to be carried out, he shall immediately respond to the same and make all out efforts to carry out the same on priority within 48 hours. In case of any delay in responding / attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs. 100/- per day per each work ordered upto 05(Five) days and Rs. 200/- per day thereafter till completion of the work in case of delay without valid reasons as decided by GE.\n[iii] Further, the above penalty is applicable even for the multiple locations of work at the same period. It is the responsibility of contractor to make suitable arrangements for attending the repairs simultaneously at all the places.\n[iv] The decision of the GE as to whether a particular repair has been attended or not on a particular day will be final and binding. The above penalty shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e (Compensation for delay in completion of work).
22M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit/casing caping of suitable size including accessories fixed on wall/floor/roof, etc including provision of pressed mild steel terminal box with (surface/concealed) 3mm thick hylem sheet top cover, provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell point controlled by one, one way switch including taking down old point wiring with fittings & fixtures complete all as specified and directed.115POINT
33All as per item No. 2 above but suitable for one 5 Amps socket point controlled by one switch on independent board35POINT
44All as per item No. 2 above but suitable for one 5 Amps socket point on the same board20POINT
55All as per item No. 2 above but point wiring with 2.5 Sqmm (nominal area) suitable for one power socket point on independent board complete all as specified and directed.20POINT
66All as per item No. 2 above but point wiring with 4.0 Sqmm (nominal area) suitable for one power socket point on independent board complete all as specified and directed.20POINT
77All as per item No. 2 above but suitable for One light point controlled by 2 Nos two way switches5POINT
88M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including Concealed PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including provision of MS terminal box with white modular cover plate & frame, provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell point controlled by one, one way switch including taking down old point wiring with fittings & fixtures complete all as specified and directed. [Note: Quoted rate is deemed to be inclusive for necessary cutting chases in walls / floors / ceiling of any description, pinning in making good to disturbed surfaces where required and pointing in cement mortar 1:3 and finished to match with existing finishes complete]780POINT
99All as per item No. 8 above but suitable for one 5 Amps socket point controlled by one switch on independent board120POINT
1010All as per item No. 8 above but suitable for one 5 Amps socket point on the same board50POINT
1111All as per item No. 8 above but suitable for One light point controlled by 2 Nos two way switches15POINT
1212All as per item No. 8 above but point wiring with 4.0 Sqmm (nominal area) suitable for one power socket point on independent board complete all as specified and directed.152POINT
1313M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn in existing concealed / surface PVC conduit including provision of MS terminal box (surface/concealed) with white modular cover plate and frame including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan / bell point / 5 Amps socket point controlled by one switch including taking down old point wiring with fittings & fixtures and making good disturbed surfaces to match with existing complete all as specified and directed.45POINT
1414All as per item No. 13 above but suitable for one 5 Amps socket point controlled by one switch on independent board15POINT
1515All as per item No. 13 above but suitable for one 5 Amps socket point on the same board10POINT
1616All as per item No. 13 above but suitable for One light point controlled by 2 Nos two way switches5POINT
1717All as per item No. 13 above but point wiring with 4.0 Sqmm (nominal area) suitable for one power socket point on independent board complete all as specified and directed.20POINT
1818S & F Switch Piano, flush type, single pole, One way, 5 Amps, 230 Volt complete all as specified.310EACH
1919S & F Switch Piano, flush type, single pole, Two way, 5 Amps, 230 Volt complete all as specified.20EACH
2020S & F switch socket combination multipurpose 3 pin, 5 Amps controlled by one 5 Amps switch complete all as specified and directed.205EACH
2121S & F switch socket combination, multipurpose, 2 in 1, 3 Pin, 5/15 Amps, flush type, universal controlled by one switch 15 Amps, 250 volts, complete all as specified and directed120EACH
2222S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed550EACH
2323S & F modular switch 1 way, 6 Amps, 1 module1020EACH
2424S & F modular switch 2 way, 6 Amps, 1 module60EACH
2525S & F modular socket outlet, 6 Amps, 2/3 pin combined 2 module200EACH
2626S & F modular socket outlet, 6/16 Amps, 2/3 pin combined 2 module180EACH
2727S & F modular electronic fan regulator, socket type, omplete all as specified and directed.175EACH
2828S & F modular bell push flush type 6 Amps110EACH
2929S & F Calling bell, AC, 230 Volts, single pole100EACH
3030S & F modular switch 1 way, 16 Amps, 1 module180EACH
3131S & F in repairs modular switch 1 way, 16 Amps, 1 module62EACH
3232M & L for sub main wiring with 2 runs of single core 1100 volts grade, 6.0 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including suitable size surface / concealed PVC conduit and conduit accessories including provision of 1 run of 6.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. \n[NOTE: 3 runs of 6.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]\n290RM
3333M & L for sub main wiring with 2 runs of single core 1100 volts grade, 4.0 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including suitable size surface / concealed PVC conduit and conduit accessories including provision of 1 run of 4.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. \n[NOTE: 3 runs of 4.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]\n260RM
3434M & L for sub main wiring with 2 runs of single core 1100 volts grade, 2.5 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including suitable size surface / concealed PVC conduit and conduit accessories including provision of 1 run of 2.5 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. \n[NOTE: 3 runs of 2.5 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]\n250RM
3535M & L for sub main wiring with 5 runs of single core 1100 volts grade, 10.0 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including surface / concealed PVC conduit of 25mm dia and conduit accessories including provision of 1 run of 10.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. \n[NOTE: 6 runs of 10.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]\n50RM
3636S & F in repairs KWH meter box of size 250x250x155mm shock proof, rust proof, with provision for cable entry at bottom and/or sides, weather proof suitable for LT single Phase KWH meter including taking down and refixing KWH meter in old / new location with all connections and testing of meter complete all as specified and directed80EACH
3737S & F in repairs GI powder coated louvers suitable for exhaust fans 300mm sweep complete all as directed. [Note: Quoted rate is deemed to be inclusive for necessary scaffolding as required for work at any height]50EACH
3838S & F in repairs factory made sheet metal enclosure double door SPN MCB DBs (fixed flush to the wall), 4 way, 240 Volts, IP-42 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed.10EACH
3939S & F in repairs factory made sheet metal enclosure double door SPN MCB DBs (fixed flush to the wall), 8 way, 240 Volts, IP-42 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed.40EACH
4040S & F in repairs factory made sheet metal enclosure double door SPN MCB DBs (fixed flush to the wall), 12 way, 240 Volts, IP-42 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed.35EACH
4141S & F in repairs factory made sheet metal enclosure double door VTPN DBs (fixed flush to the wall) with provision for MCCB, four Pole as incomer and outgoing as TPN, 6 way, 415 Volts, IP-42 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed. [Note: MCCB shall be measured and paid seperately]10EACH
4242S & F in repairs factory made sheet metal enclosure double door TPN MCB DBs (fixed flush to the wall), 4 way, 415 Volts, IP-42 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed.10EACH
4343S & F in repairs sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete all as specified and directed.25EACH
4444S & F in repairs Isolator, TPN, 100 Amps, 415 Volt, 125 KA, 50 Hz complete all as directed15EACH
4545S & F in repairs MCB, TPN, 63 Amps, 415 Volt, rupturing capacity 16 KA, 50 Hz, 'B' curve complete all as directed32EACH
4646S & F in repairs MCB, TP, 63 Amps, 415 Volt, rupturing capacity 16 KA, 50 Hz, 'B' curve complete all as directed35EACH
4747S & F in repairs MCB, TPN, 40 Amps, 415 Volt, rupturing capacity 16 KA, 50 Hz, 'B' curve complete all as directed20EACH
4848S & F in repairs MCB, TP, 40 Amps, 415 Volt, rupturing capacity 16 KA, 50 Hz, 'B' curve complete all as directed14EACH
4949S & F in repairs MCB, SPN, 40 Amps, 240 Volt, rupturing capacity 10 KA, 50 Hz, 'B' curve complete all as directed40EACH
5050S & F in repairs MCB, SPN, 63 Amps, 240 Volt, rupturing capacity 10 KA, 50 Hz, 'B' curve complete all as directed35EACH
5151S & F in repairs MCB, SP, 6 to 32 Amps, 240 Volt, rupturing capacity 10 KA, 50 Hz, 'B' curve complete all as directed300EACH
5252S & F in repairs MCB, SP, 40 Amps, 240 Volt, rupturing capacity 10 KA, 50 Hz, 'B' curve complete all as directed75EACH
5353S & F in repairs RCCB for earth leakage over load & short circuit protection DP, 40 Amps, 100mA, 240 Volts, AC supply complete all as directed45EACH
5454S F in repairs MCCB, FP, 100 Amps, 415 Volts fixed type breaking capacity 16 KA complete all as directed6EACH
5555S F in repairs MCCB, FP, 200 Amps, 415 Volts fixed type breaking capacity 35 KA complete all as directed4EACH
5656Taking down existing light fittings of any type LED light / security lights from any position and refixing the same in new/old location with new clamps, nuts, washers and PVC copper cable as required at site complete all as specified and directed by the Engineer-in-Charge.380EACH
5757Taking down existing ceiling fan of any type and sweep from any position and refixing the same in original / new location after necessary servicing, cleaning for dust, grease including replacement of minor spares such as bushes, bearings, canopy, capacitors, etc as required at site and applying two coats of synthetic enamel paint (spray painting) including filling the cavities with filler and writing MES Nos on the fans complete all as specified and directed by the Engineer-in-Charge. [Note: Quoted rate is deemed to be inclusive for writing MES Nos on the fans]250JOB
5858M & L for removing defective / burnt out winding of ceiling fans of any capacity and rewinding with super enamelled copper winding wire of suitable size complete all as specified and directed by the Engineer-in-Charge.110EACH
5959Taking down existing Exhaust fan / Air circulator / Pedestal fan / wall mounted fan of any type and sweep from any position and refixing the same in new / old position after necessary over hauling / servicing and cleaning for dust, grease including replacement of minor spares such as bushes, bearings, capacitors, etc as required at site and applying two coats of synthetic enamel paint (spray painting) including filling the cavities with filler including replacement of defective spares complete all as specified and directed by the Engineer-in-Charge. [Note: Quoted rate is deemed to be inclusive for writing MES Nos on the fans]50EACH
6060M & L for removing defective / burnt out winding of Exhaust fan / Air circulator / Pedestal fan / wall mounted fan of any capacity and rewinding with super enamelled copper winding wire of suitable size complete all as specified and directed by the Engineer-in-Charge.25EACH
6161S & F LED tube light fittings, retro bar professional WH 5700K to 6200K and minimum 1800 to 2000 lumens of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.150EACH
6262S & F LED tube light fittings, 2 feet long of 900 to 1000 lumens of cool white wall mounted batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.80EACH
6363S & F LED Mirror light fitting of 5 Watt with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down existing light fittings of any type and making good to the disturbed surafces to match with existing complete all as specified and as directed by the Engineer-in-Charge.30EACH
6464S & F in repairs LED bulb 9 watts with pin type holder (PVC / Polycarbonate insulated body) with back plate complete all as directed150EACH
6565S & F Building Security light LED type of minimum 4500 Lumens Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 25mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.50EACH
6666S & F in repairs batten suitable for LED T8 lamps150EACH
6767Supply and replacement MS powder coated down rod of size 15mm bore, 45 to 100mm long with necessary holes suitable for hanging ceiling fans of any sweep complete all as specified.20EACH
6868Supply and replacement MS powder coated down rod of size 15mm bore 1200mm (48'') long with necessary holes suitable for hanging ceiling fans of any sweep complete all as specified.25EACH
6969Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth lead 4mm dia by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed.\n[Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, Precast RCC 1:2:4, Type B-1 cover 40mm thick reinforced with 8mm dia CTD bars @ 75mm c/c both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 15mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]28JOB
7070S & F Earth continuity conductor or main earthing lead of 4mm dia GI wire fixed to wall on batten or recess or cases or buried in ground or drawn in conduit / pipe or fixed to poles complete all as specified.150RM
7171M & L for removing the old rusted steel DB (SPN/TPN) of any type and description including metering arrangements complete after dressing the incoming and outgoing cable and securing it properly and filling the cavity / blank space with brick masonry in CM 1:6 and rendering with CM 1:4 and finishing the surfaces with two coats of distemper over a coat of primer over thick layer of putty and refixing the DBs so as to flush with the wall complete all as directed by the Engineer-in-Charge30JOB

AI Tender Summary

OUR REF NO 27937685
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 09-06-2021
Authority
Authority Name Military Engineer Services
Work Description Repair Replacement Of Internal Wiring Fittings Fixtures At Meghadripeta Ashoka Park Pallava Park Namac Ctw Nsb Area Under Age Em Of Ge Nd Visakhapatnam
Basic Detail
Tender No 8955/GEND
Bidding Type Tender
Location
City Visakhapatnam
State Andhra Pradesh
Key Dates
Publish Date 17 May 2021
Submission Date 09 Jun 2021
Open Date 15 Jun 2021
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Not Available
Document List
BOQ_494535.xls
A24AE7A3-AB44-47DD-95CB-651A0F5DFA11.html
8955Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 17, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 09, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 15, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_494535.xls

html

A24AE7A3-AB44-47DD-95CB-651A0F5DFA11.html

pdf

8955Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender