Coal and Mines Boards / Undertakings / PSU Closing in 0 days TDR #27925520

Procurement Of Anchor Testing Machine 50 T Capacity -Vibration Meter -Vibrometer For Underground Coal Mines

Issued by Boards / Undertakings / PSU · WCL AGM Office Kanhan Area Dungaria, Madhya Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Jun 2021
0 days left
EMD
8720
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
WCL AGM Office Kanhan Area Dungaria → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Procurement Of Anchor Testing Machine 50 T Capacity -Vibration Meter -Vibrometer For Underground Coal Mines

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 14-Jun-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-Jun-2021

BOQ

Name of Work: Procurement of Anchor Testing Machine 50 T Capacity & Vibration meter /Vibrometer for Underground mines
Sl.No.Item DescriptionItem Code / MakeQtyUnit
11Anchor Testing Machine 50 T Capacity\nTECHNICAL SPECIFICATION \n1. The equipment should be suitable to measure the anchorage resistance (Pull out force) of roof bolts and roof stitching confirming to the latest DGMS circular no. 5 of 2002 and DGMS circular no 11 of 2002 clause VII\n2. This should be incorporated with portable hydraulic jack of minimum 50 tonne capacity with a central hole and bridge assembly.\n3. It should be fitted with suitable dial type 100 mm dia pressure gauge of reputed quality and calibrated from 0 to 50 tonnes with least count of 500 kg \n4. Jucking device to be operated with a separate hydraulic pump by suitable operating level. The Hydraulic fluid used in the machine shall be DGMS approved.\n5. At least five (5) meter long DGMS APPROVED high pressure hydraulic hose with and fittings is to be provided for connecting the hydraulic jack.\n6. The run of the piston should be minimum 15 cm.\n7. The testing machine should be complete with all accessories like pulling head for bolts, bearing plate, pulling head for wire rope and other hardware etc.\n8. A separate reaping kit along with operating manual & spare parts list is to be provided.\n9. Manufacturers name plate with SL No. of the machine to be provided in each machine.\n10. Manufacturers test certificate to be provided with each machine6.5305e+102Nos
22Vibration meter/Vibrometer ( SIESMOGRAPH)\nTechnical specification :\nThe vibration measuring 4 channel system shall be compact light weight and handy to operate for the measurement of ground vibration in respect of peak particle velocity in various directions frequency and air (noise) due to ballasting etc. It shall be supplied with all the required ready to use accessories like ( external triaxial geophones, microphone, cable for geophone and microphone, USB adapter cable. AC power charger, carrying case, manual etc) and software.\n• Range at least 200 mm /sec or more .\n• Frequency analysis : frequency at peak , USBM, DGMS(A)DGMS(B), CRI OSMRE & DIN analysis with quick report.\n• Sample rate : 1024 S/s to 4096 S/s per channel ( independent of record time)\n• Responses : All Channels- 2 to 250 HZ(_33dB)\n• Record mode: Manual and continuous.\n• Record time : 1 to 20 sec (programmable in one – second steps) auto record time programmable for 1 to 9 sec.\n• Storage Capacity : Minimum 250 one second full – wave form events at 1024 S/s sample rate event summaries : Minimum 1500\n• Battery life : Rechargeable sealed gel cell battery – capacity for at least 200 hours of continuous monitoring \n• Operating temperature : Must operate with full efficiency from 0 degree Celsius to 48 degree Celsius.\n• Power charge : suitable charger with connecting cable etc. For 220 v 50C/s AC input supply.\n• Event report data analysis software: The data analysis software should generate event report on CMRI, DGMS (A), DGMS (B) permissively ground vibrating standards. The sample report must be enclosed to demonstrate software capability.\n• Repair/calibration/after sales service facility in India : after sales service repair facility and calibration facility for the supplied instrument should be available in India for yearly calibration and testing for ascertaining the reliability to the instrument and servicing /repair which may be needed . The same must be committed and proved by the tenderer . Inspection of the repair , calibration/testing facility within India shall be done by the authorised representative. \n1.55561e+101Nos

AI Tender Summary

OUR REF NO 27925520
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 18-06-2021
Authority
Authority Name Western Coalfields Limited
Work Description Procurement Of Anchor Testing Machine 50 T Capacity -Vibration Meter -Vibrometer For Underground Coal Mines
Basic Detail
Tender No WCL/KAN/APC/skp/21-22/eOT-18 dt.17.5.21
Bidding Type Tender
Location
City WCL AGM Office Kanhan Area Dungaria
State Madhya Pradesh
Key Dates
Publish Date 14 Jun 2021
Submission Date 18 Jun 2021
Open Date 19 Jun 2021
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 8720
Exemption Not Available
Document List
BOQ_212545.xls
TPS_212545.xls
F6F87B01-23D7-4235-A708-97402061AB36.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 14, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 18, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 18, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 19, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_212545.xls

xls

TPS_212545.xls

html

F6F87B01-23D7-4235-A708-97402061AB36.html

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders