Repair To Sunken Floor And Misc Repair To Certain Md And Otm Accn Including Mes Installations , Internal Electrification Including Fittings And Fixtures And Old Mcb Db , Mcb Earthing , Sub Main Wiring Service Wire Along With Connected Items Under Age

Tender Notice

27908446
Corrigendum : Repair To Sunken Floor And Misc Repair To Certain Md And Otm Accn Including Mes Installations , Internal Electrification Including Fittings And Fixtures And Old Mcb Db , Mcb Earthing , Sub Main Wiring Service Wire Along With Connected Items Under Age
Indian
Gujarat
08-06-2021
15-06-2021
17-06-2021

Tender Details

Repair To Sunken Floor And Misc Repair To Certain Md And Otm Accn Including Mes Installations , Internal Electrification Including Fittings And Fixtures And Old Mcb Db , Mcb Earthing , Sub Main Wiring Service Wire Along With Connected Items Under Age

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Jun-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-06-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.00 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work: REPAIR TO SUNKEN FLOOR AND MISC REPAIR TO CERTAIN MD AND OTM ACCN INCLUDING MES INSTALLATIONS, INTERNAL ELECTRIFICATION INCLUDING FITTINGS AND FIXTURES AND OLD MCB DB, MCB EARTHING, SUB MAIN WIRING SERVICE WIRE ALONG WITH CONNECTED ITEMS UNDER AGE B/R-II AND AGE E/M AT GE(ARMY) BHUJ
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for special treatment of sunken portion of WCs and Bath room as per following stages:\nStage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc .\nStage 2:- Providing 10mm thick plaster in CM 1:3 with chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd\nStage 3:- Applying Dr Fixit Primseal primer or STP Ltd (and allow to dry for 8 hours) under touch dry condition\nStage 4:- Applying two coats of water proofing decorative elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP(The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufacturer instruction\nStage 5:- Making holes in wall and fixing 600mm long 40mm dia GI spout for draining the surplus water if any. BI01010001010000000000000515BI0100001113 35 Sqm
2 2 M&L Plain cement concrete 1:4:8 type D-2 as in mass filling in sunken portion complete all as specified and directed. BI01010001010000000000000515BI0100001114 16.5 Cum
3 3 S&F in repair vitreous china squatting pan, Orissa pattern, size 580 x 440 mm white with integral foot rests and connection with cast iron P trap and to flushing pipe, anti syphonage pipe etc (excluding flushing cistern and flush pipe) complete with provision of lime concrete bedding including taking down/ Dismantling existing unserviceable WC of any description and in any position & fixing new WC in repair and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed. BI01010001010000000000000515BI0100001115 34 Each
4 4 S & F in repair vitreous china wash basin, white flat back , size 550mmx450mm with and including Waste fittings, brass, chromium plated for basins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated fancy type pillar tap 15mm bore, screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipe complete all as specified and directed. BI01010001010000000000000515BI0100001116 13 Each
5 5 S & F in repair vitreous china wash basin, white flat back , size 450mmx300mm with and including Waste fittings, brass, chromium plated for basins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated, fancy type, pillar tap, 15mm bore, screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipe complete all as specified and directed. BI01010001010000000000000515BI0100001117 20 Each
6 6 S&F in repair PVC valve-less, syphonic action type, flushing cistern, low level, 10 litre capacity (ISI marked) white with inlet, ball valve, float and handle including brackets complete all as specified and directed. BI01010001010000000000000515BI0100001118 32 Each
7 7 S&F Stop valves, cast copper alloy, ISI marked ,screwed down high pressure with crutch of butter fly handle, fancy type , chromium plated, with long shank and cup, screwed both ends for iron pipes or for union , for 15 mm bore , complete all as specified and directed. BI01010001010000000000000515BI0100001119 65 Each
8 8 Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 15mm dia, any grade, of any description or in any position including fittings complete all as specified and directed BI01010001010000000000000515BI0100001120 325 RM
9 9 Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 20mm dia, any grade, of any description or in any position including fittings complete all as specified and directed BI01010001010000000000000515BI0100001121 260 RM
10 10 Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exc 10 cm girth BI01010001010000000000000515BI0100001122 325 RM
11 11 Supplying and Laying 16mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed BI01010001010000000000000515BI0100001123 325 RM
12 12 Supplying and Laying 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed BI01010001010000000000000515BI0100001124 260 RM
13 13 S&F bib tap, cast copper alloy chromium plated, screwed down high pressure with crutch of butter fly handle fancy type CP for 15 mm bore dia complete all as specified and directed. BI01010001010000000000000515BI0100001125 65 Each
14 14 S&F for Swivel shower rose size 125 mm of PTMT , any colour , for fixing with 15 mm dia pipe ,( minimum weight 40 gm. ) with and including Shower arm 15 mm size, 195 mm long with bend of 45 degree with flange of PTMT any colour (Min wt. 40gms) , fixed in repairs, complete all as specified and directed. BI01010001010000000000000515BI0100001126 32 Each
15 15 S&F PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed BI01010001010000000000000515BI0100001127 65 Each
16 16 S/F in repair 75 mm bore PVC (SWR) floor trap plain with grating incl jointing with solvent cement complete all as specified and directed BI01010001010000000000000515BI0100001128 100 Each
17 17 S&F in repair vitreous china Wash down water closet (pedestal pattern), complete including Pedestal pan and trap and seat cover, including connection to drain ( or outgoing pipe) and flushing pipe, antisyphonage pipes etc (excluding flushing cistern and flush pipe) complete all as specified and directed BI01010001010000000000000515BI0100001129 32 Each
18 18 S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes ; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting unions to pipe, overall size 495mmX420mm bowl size 410mmX330mmX160mm complete all as specified and directed BI01010001010000000000000515BI0100001130 25 Each
19 19 S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes ; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting unions to pipe, overall size 915mmX460mm bowl size 410mmX330mmX160mm complete all as specified and directed BI01010001010000000000000515BI0100001131 6 Each
20 20 S&F in repair Rotational moulded polyethylene water storage tanks 1000 Litres Capacity ( Cylindrical vertical with closed top hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed BI01010001010000000000000515BI0100001132 36 Each
21 21 Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed BI01010001010000000000000515BI0100001133 1.56 10 Sqm
22 22 M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over 20mm thick screed layer in cement mortar 1:6 and pointed in white cement with pigment to match with colour of tile complete all as specified and directed BI01010001010000000000000515BI0100001134 13 Sqm
23 23 M&L Granite (of any type) tiles 20mm thick machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete laid over 10mm thick screed layer in cement mortar 1:4 complete all as specified and directed BI01010001010000000000000515BI0100001135 2.6 Sqm
24 24 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed BI01010001010000000000000515BI0100001136 32.5 RM
25 25 Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as directed BI01010001010000000000000515BI0100001137 485 Sqm
26 26 M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed. BI01010001010000000000000515BI0100001138 95 Sqm
27 27 M&L for glazed ceramic tiles, coloured tiles, 450X350X7mmm x 7mm thick on vertical faces i.e.. as in skirting/dado etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fix over and including 10 mm thick backing coat in cement mortar (1:4) complete all as specified and directed. BI01010001010000000000000515BI0100001139 390 Sqm
28 28 Taking down cement plaster of any description and in any position of brick or stone wall/concrete surfaces on walls ,ceiling etc including raking out joints ,hacking for key scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed BI01010001010000000000000515BI0100001140 260 Sqm
29 29 M&L rendering 15 mm thick in CM 1:6 on brick/concrete wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed . BI01010001010000000000000515BI0100001141 195 SQM
30 30 M&L for preparation of the newly plastered surfaces of walls & applying two coats distemper oil- emulsion , white or tinted over a coat of primer surfaces of wall complete all as specified and directed. BI01010001010000000000000515BI0100001142 195 Sqm
31 31 M&L for rendering 5 mm thick in Cement Mortar (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and directed. BI01010001010000000000000515BI0100001143 65 Sqm
32 32 M&L for preparation of the newly plastered surfaces of ceiling & applying 3 coats of white wash on ceiling surfaces complete all as specified and directed. BI01010001010000000000000515BI0100001144 65 Sqm
33 33 Taking down existing wire mesh of any description and in any position and supplying and fixing Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm (weight not less than 600 gms/per sqm) and fixed with aluminium wire staples, wooden beads etc complete all as specified and directed BI01010001010000000000000515BI0100001145 50 SQM
34 34 Hacking out old broken glass of any thickness and any description from metal frame and supply and fixing 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed. BI01010001010000000000000515BI0100001146 25 SQM
35 35 Hacking out old broken glass of any thickness and any description from metal frame and supply and fixing 3 mm thick, figured glass, Pin headed type ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed. BI01010001010000000000000515BI0100001147 6.5 SQM
36 36 Taking down carefully copper/aluminium point wiring (light,fan,socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody ot for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed. BI01010001010000000000000515BI0100001148 300 Per Point
37 37 M&L for point wiring for One light/fan/exhaust fan/buzzer point controlled by one,one way switch with using 1.5 Sqmm (nominal sectional area) multi stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including PVC casing and capping/PVC Conduit of adequate size fixed on surface with PVC rawl plugs with and including Wooden Board/sunken type pressed steel terminal boxes of required size of not less than 1.6 mm thick factory made and factory painted with top cover 3mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core multi-stranded copper conductor 1.5 sqmm size PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit/casing capping complete for one light/fan/exhaust fan point controlled by one; one way switch. \nNOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. \n(ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'.\n(iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers\n BI01010001010000000000000515BI0100001149 130 Per Point
38 38 All as per item No. 37 here-in-before but One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch. BI01010001010000000000000515BI0100001150 30 Per Point
39 39 All as per item No. 37 here-in-before but One 3 pin socket out let 5 amp point on the (same board) with other switches. BI01010001010000000000000515BI0100001151 30 Per Point
40 40 All as per item No. 37 here-in-before but with using 2.50 Sqmm cable and 1.5sq mm earth cable PVC insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board. BI01010001010000000000000515BI0100001152 20 Per Point
41 41 M&L for point wiring with using 1.5 Sqmm (nominal area) multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including PVC conduit pipe of adequate size fixed on surface with PVC rawl plugs with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- (A) One light/buzzer/fan/exhaust fan point controlled by one; one way switch. \nNOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. \n(ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'.\n(iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers\n BI01010001010000000000000515BI0100001153 60 Per Point
42 42 All as per item No. 41 here-in-before but One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch. BI01010001010000000000000515BI0100001154 10 Per Point
43 43 All as per item No. 41 here-in-before but One 3 pin socket out let 5 amp point on the (same board) with other switches. BI01010001010000000000000515BI0100001155 10 Per Point
44 44 All as per item No. 41 here-in-before but with using 2.50 Sqmm cable and 1.5sq mm earth cable PVC insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board. BI01010001010000000000000515BI0100001156 10 Per Point
45 45 S & F ceiling rose, surface bakelite, 65X20mm three terminal complete all as specified and directed. BI01010001010000000000000515BI0100001157 190 Each
46 46 S & F switch piano flush button single pole230 / 250 volts one way 5 Amps Complete all as specified and directed. BI01010001010000000000000515BI0100001158 270 Each
47 47 S & F socket outlet 5 pin 5 Amp, flush type complete all as specified and directed. BI01010001010000000000000515BI0100001159 80 Each
48 48 S & F switch socket combination multi-purpose two in one, 3 pin, 5 and 15 Amp, flush type complete all as specified and directed. BI01010001010000000000000515BI0100001160 30 Each
49 49 S & F bell push button single pole230 / 250 volts 5 amps Complete all as specified and directed. BI01010001010000000000000515BI0100001161 10 Each
50 50 S & F bell ding dong AC, 230 volts single pole complete all as specified and directed. BI01010001010000000000000515BI0100001162 10 Each
51 51 S & F deluxe electronic ceiling fan regulator rotatry type, four step 120/240 Volt and connecting all as directed. BI01010001010000000000000515BI0100001163 60 Each
52 52 S & F in repairs earth plug and socket, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 volts with and including one MCB, SP, 20A, 240 Volts as per all as specified and directed. BI01010001010000000000000515BI0100001164 5 Each
53 53 S & F in replacement elegantly industrial general purpose box type luminaire, 1x20 Watt, designed box type LED luminaries, CRCA sheet steel housing with white reflector cover fitted to the body with decorative end covers complete with electronic ballast, spring loaded rotor type lamp holders, connected block with and including 01 No LED lamp 20 Watt and all accessories, pre-wired and connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light fitting to walls / roof surface over and including 2 Nos PVC square box complete all as specified and directed. BI01010001010000000000000515BI0100001165 30 Each
54 54 S & F in replacement 10 W mirror light having indirect up down light for mirror and as well light application with CCT 6000K, including LED Bulb/Module and Electrical connection with 3 core flexible wire of appropriate size from ceiling rose to the tubelight fitting, all as specified and directed. BI01010001010000000000000515BI0100001166 10 Each
55 55 S&F lamp holder PVC / Polycarbonate type with cord grip cap suitable for LED/CFL lamp fitting complete all as specified and directed. BI01010001010000000000000515BI0100001167 30 Each
56 56 Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for MCB DB SPN 08 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed. BI01010001010000000000000515BI0100001168 10 Each
57 57 Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for MCB DB SPN 04 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed. BI01010001010000000000000515BI0100001169 5 Each
58 58 Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for MCB DB SPN 12 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed. BI01010001010000000000000515BI0100001170 5 Each
59 59 Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for vertical type MCB DB TPN 04 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed. BI01010001010000000000000515BI0100001171 5 Each
60 60 Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for vertical type MCB DB TPN 06 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed. BI01010001010000000000000515BI0100001172 5 Each
61 61 Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for vertical type MCB DB TPN 08 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed. BI01010001010000000000000515BI0100001173 5 Each
62 62 Supply and fixing MCB TPN, 63 Amps in `C’ series having current rating 10 KA complete all as specified and directed. BI01010001010000000000000515BI0100001174 15 Each
63 63 Supply and fixing MCB SPN, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed. \n BI01010001010000000000000515BI0100001175 80 Each
64 64 S&F MCB single pole, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.\n BI01010001010000000000000515BI0100001176 120 Each
65 65 Taking Down Old Unserviceable Submain wiring complete including all accessories and making good the disturbed surfaces and M/L for Sub main wiring with 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 4 Sqmm drawn through PVC conduit/casing capping including accessaries with 2.5 sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up ,all as directed. Note: 2 runs of cable and one run earth wire and conduit/Casing & Caping will be measured as one length complete all as specified and directed BI01010001010000000000000515BI0100001177 100 RM
66 66 Taking Down Old Unserviceable Submain wiring complete including all accessories and making good the disturbed surfaces and M/L for Sub main wiring with 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 6 Sqmm drawn through PVC conduit/casing capping including accessaries with 4 sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up ,all as directed. Note: 2 runs of cable and one run earth wire and conduit/Casing & Caping will be measured as one length complete all as specified and directed BI01010001010000000000000515BI0100001178 100 RM
67 67 M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ BI01010001010000000000000515BI0100001179 5 Each
68 68 M&L for repair to light fittings, sockets, switches and bell and in any type, make and capacity and in any position including replacing unserviceable item or replacing whole fixture, fittings complete all as specified and directed.\nNote : The unserviceable item should be paid separately BI01010001010000000000000515BI0100001180 700 Each Job
69 69 Supplying only choke suitable for and upto 18/20 W flouescent tube light fitting as per existing model complete all as specified and directed BI01010001010000000000000515BI0100001181 100 Each
70 70 All as per item No 69 here in before but of capacity for and upto 36/40 W flourescent tube light fitting complete all as specified and directed BI01010001010000000000000515BI0100001182 400 Each
71 71 Supplying only flourescent tube rod 36/40 W as per existing model complete all as specified and directed BI01010001010000000000000515BI0100001183 300 Each
72 72 All as per item No 71 here in before but of capacity for and upto 18/20 W flourescent tube light fitting complete all as specified and directed BI01010001010000000000000515BI0100001184 100 Each
73 73 Supplying only LED 18 W Rod suitable for 1x18 W LED fitting suitable suitable for existing make complete all as specified and directed BI01010001010000000000000515BI0100001185 30 Each
74 74 S & F in replacement LED mirror light for photo frame complete all as specified and directed BI01010001010000000000000515BI0100001186 3 Each
75 75 S & F decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base complete all as specified and directed BI01010001010000000000000515BI0100001187 10 Each
76 76 S & F in replacement LED spot (recessed) white light 15 W round type AC 90 - 260 volts including all accessories and fixing arrangement complete all as specified and directed BI01010001010000000000000515BI0100001188 10 Each
77 77 S & F in replacement LED spot (recessed) white light 12 W round type AC 90 - 260 volts including all accessories and fixing arrangement complete all as specified and directed BI01010001010000000000000515BI0100001189 10 Each
78 78 S & F in replacement LED spot (recessed) white light 6 W round type AC 90 - 260 volts including all accessories and fixing arrangement complete all as specified and directed BI01010001010000000000000515BI0100001190 10 Each
79 79 S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. \nNote :- The retreived materials have been mentioned in the Sch of credit in the tender documents in pdf form. The amount of Sch of credit will be deducted offline from the amount of BOQ at the time of acceptance. BI01010001010000000000000515BI0100001191 10 Each Job
Disclaimer :