| 1 | 1 | M&L Taking down Street/Perimeter/Flood Light Fitting of any type and any capacity from any Height after disconnecting, Opening Cover and Checking of Light Fitting, Repairing as required, Re-fixing the Light Fitting after repaired in Original Position and Providing Connections including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed.\nNOTE : New Spares/Parts (Quantites are Provisional) will be Measured and Paid separately under respective Items as 'Supply only'. | BI01010001010000000000000515BI0100001113 | 65 | EACH JOB |
|---|
| 2 | 2 | Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 25 Watt, complete all as specified and as directed. | BI01010001010000000000000515BI0100001114 | 20 | EACH |
|---|
| 3 | 3 | Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 30 Watt, complete all as specified and as directed. | BI01010001010000000000000515BI0100001115 | 20 | EACH |
|---|
| 4 | 4 | Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 45 Watt, complete all as specified and as directed. | BI01010001010000000000000515BI0100001116 | 20 | EACH |
|---|
| 5 | 5 | Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 100 Watt, complete all as specified and as directed. | BI01010001010000000000000515BI0100001117 | 5 | EACH |
|---|
| 6 | 6 | S&F LED Street Light Fitting 30 Watt Environmental Friendly, Energy Saving, New Generation, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELLS/ PHILIPS (as approved by GE) | BI01010001010000000000000515BI0100001118 | 30 | EACH |
|---|
| 7 | 7 | S&F LED Street Light Fitting 45 Watt Environmental Friendly, Energy Saving, New Generation, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELLS/ PHILIPS (as approved by GE) | BI01010001010000000000000515BI0100001119 | 35 | EACH |
|---|
| 8 | 8 | S&F LED Street Light Fitting 100 Watt Environmental Friendly, Energy Saving, New Generation, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELLS/ PHILIPS (as approved by GE) | BI01010001010000000000000515BI0100001120 | 4 | EACH |
|---|
| 9 | 9 | S&F BAMBOO Light Fitting, New Generation, Environmental Friendly, Energy Saving, Long Life, Aesthetically Designed, Aluminium Landscape Luminaire for Diffused Lighting with High Power LED as Light Source, IP-65 protected, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELLS, Cat No. BAMBOOBL8WLED830SSYMTOPCM (1.0 M) or equivalent in Model in Make : BAJAJ/ CG/ C&S/ PHILIPS (as approved by GE) | BI01010001010000000000000515BI0100001121 | 10 | EACH |
|---|
| 10 | 10 | S&F RUBY (CLEAR), New Generation, Post Top, New Generation, Energy Saving, Environmental Friendly, Long Life, Aesthetically Designed with Symmetrical Light Distribution, Spun Aluminium Landscape Luminaire with High Power LEDs as Light Source, IP-65 protected, suitable for Pole 76mm dia, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELLS, Cat No. RUBYPT25WLED757PSYMTOPC or equivalent Model in Make : BAJAJ/ CG/ C&S/ PHILIPS (as approved by GE) | BI01010001010000000000000515BI0100001122 | 4 | EACH |
|---|
| 11 | 11 | S&F GRACE Small Decorative Gate Light Fitting, made up of High Grade Unbreakable Polycarbonate Material suitable for Retrofit CFL 20 Watt Spiral/ 10 Watt LED Bulb with B-22 Base, having Mounting Pole Dia - 60mm (Max) OD, Width: 160mm & Height : 284mm, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELLS, Cat No. LHFHASN1TL4K015 or equivalent Model in Make : BAJAJ/ CG/ C&S/ PHILIPS (as approved by GE) | BI01010001010000000000000515BI0100001123 | 6 | EACH |
|---|
| 12 | 12 | S&F MOON (PRISMAT IC) Decorative Gate Light Fitting, made up of High Grade Unbreakable Polycarbonate Material suitable for Retrofit CFL 8 Watt/ 14 Watt (TU)/ LED Lamp B-22 Base Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELLS, Cat No. LHFXBON1TN6F023 or equivalent Model in Make : BAJAJ/ CG/ C&S/ PHILIPS (as approved by GE) | BI01010001010000000000000515BI0100001124 | 10 | EACH |
|---|
| 13 | 13 | S&F PVC insulated Aluminium Wire 1.5 Sqmm, 3 Core for Providing Connection from Overhead Line to Street Light Fitting including Taking down Unserviceable Wire of any description, complete all as specified and as directed. | BI01010001010000000000000515BI0100001125 | 200 | RUNNING METRE |
|---|
| 14 | 14 | M&L Trimming/Cutting of Tree Branches of any girth/size and Clearing of LT OH Lines (any Nos. of ACSR Conductors, Earth Wire, etc.) upto 4.00 Metre distance, Removing Tree Branches from the Sites, complete all as specified and as directed. | BI01010001010000000000000515BI0100001126 | 100 | EACH SPAN |
|---|
| 15 | 15 | M&L Preparing Surfaces of LT Pre-stressed Concrete Pole including Cross Arms Channel, Flat Iron Clamps, etc., applying Two Coats of Cement Base Paint to Pre-stressed Concrete Pole, One Coat of Synthetic Enamel Painting to Pole in Strips 250mm high (5 No.) with Two different Colours from Top of PCC Copping, Writing Pole Number with Black Paints, Height of letters not less than 65mm including applying One Coat of Aluminum Paint to Cross Arms, Channel, Flat Iron Clamps, etc. complete all as specified and as directed. | BI01010001010000000000000515BI0100001127 | 20 | EACH JOB |
|---|
| 16 | 16 | M&L Preparing Surfaces of LT Steel Tubular Pole including Cross Arms, Channel, Flat Iron Clamps, etc. applying One Coat of Aluminium Paint to Pole, One Coat of Synthetic Enamel Painting to Pole in Strips 250mm high (5 No.) with Two different Colours from Top of PCC Copping, Writing Pole Number with Black Paints, Height of letters not less than 65mm including applying One Coat of Aluminum Paint to Cross Arms, Channel, Flat Iron Clamps, etc. complete all as specified and as directed. | BI01010001010000000000000515BI0100001128 | 40 | EACH JOB |
|---|
| 17 | 17 | Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Serviceable (if any) Cables, Bricks/Cable Protection Cover, etc. keep in Safe Custody for re-use, complete all as specified and as directed.\nNOTE : Necessary Earth Works will be Measured & Paid under appropriate Items. | BI01010001010000000000000515BI0100001129 | 300 | RUNNING METRE |
|---|
| 18 | 18 | Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable, Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001130 | 81 | CUBIC METRE |
|---|
| 19 | 19 | Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001131 | 52 | CUBIC METRE |
|---|
| 20 | 20 | Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001132 | 29 | CUBIC METRE |
|---|
| 21 | 21 | Supply & Laying XLPE Insulated, Armoured, Heavy duty Electric Cable with Aluminium Conductor 1100 Volt grade, Cross-sectional Area 10 Sqmm 2 Core, laid in Tenches or fixing to Electric Poles or Passing through Pipes/ along Walls/ Roof/ across Drains/ Culvert, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001133 | 200 | RUNNING METRE |
|---|
| 22 | 22 | M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 35 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001134 | 100 | RUNNING METRE |
|---|
| 23 | 23 | Taking down unserviceable LT Cable Cross-sectional area 6 Sqmm 2 Core to 16 Sqmm 2 Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001135 | 200 | RUNNING METRE |
|---|
| 24 | 24 | Taking down unserviceable LT Cable Cross-sectional area 35 Sqmm 3½ Core to 70 Sqmm 3½ Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001136 | 100 | RUNNING METRE |
|---|
| 25 | 25 | M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.\nNOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured. | BI01010001010000000000000515BI0100001137 | 25 | CUBIC METRE |
|---|
| 26 | 26 | Supply & Laying Bricks, Sub-class ‘B’, Well burnt of size 230x115x75mm, Covering as Mechanical Protection to Cable, laid Flat dry with Width Equal to Length of Brick, complete all as specified and as directed. | BI01010001010000000000000515BI0100001138 | 2340 | EACH |
|---|
| 27 | 27 | S&F MCCB 63 Amp 4 Pole, 35 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed.\nMAKE : ABB/ LEGRAND/ SCHNEIDER/ SIEMENS (as approved by GE) | BI01010001010000000000000515BI0100001139 | 2 | EACH |
|---|
| 28 | 28 | S&F MCCB 100 Amp 4 Pole, 35 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed.\nMAKE : ABB/ LEGRAND/ SCHNEIDER/ SIEMENS (as approved by GE) | BI01010001010000000000000515BI0100001140 | 2 | EACH |
|---|
| 29 | 29 | S&F On Load Change Over Switch (Front Operated) Open Execution, 100 Amp rating, 4 Pole, 415 Volt, fixing in any Situation/as directed and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed.\nMAKE : LEGRAND, Cat Part No. CSCS100NM4CO or equivalent Model in Make : ABB/ SCHNEIDER/ SIEMENS (as approved by GE) | BI01010001010000000000000515BI0100001141 | 1 | EACH |
|---|
| 30 | 30 | M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.5 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. | BI01010001010000000000000515BI0100001142 | 2 | EACH SET |
|---|
| 31 | 31 | M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.3mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. \nNOTE : All Joints should be joined by Exothermic Welding or Brazing. | BI01010001010000000000000515BI0100001143 | 2 | EACH SET |
|---|