| Name of Work : REPAIR/REPLACEMENT OF SUMMER APPLIANCES INCLUDING WATER COOLERS, DESERT COOLERS, REFRIGERATION AND AIR CONDITIONING AT AF STATION CHANDIGARH | |||||
|---|---|---|---|---|---|
| SERIAL No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | 1 REPAIR TO WINDOW TYPE AIR CONDITIONER OF ANY MAKE AND TYPE OF CAPACITY 1.5 TR | |||
| 2 | 1.01 | Dismantling & taking out unserviceable sealed unit from existing window type AC 1.5 ton capacity, Supply and fix reciprocating/rotary type company new compressor suitable for Make :- Carrier/ voltas/ Emersion/ Videocon including cleaning of condenser/cooling coil, charging of compressor oil, Refrigerant R-22 & testing, including replacement of new Bushes, washers, mounting Rubbers, Nuts & Bolts, complete all as specified and directed. | 20 | Each Job | |
| 3 | 1.02 | Dismantling and taking out window type air conditioner of capacity 1.5/2.0 Ton of any make/type from its original location, carrying out maintenance/overhauling cleaning with vacuum cleaner and greasing, including cleaning of condensers/cooling coil, cleaning of air filter with caustic soda and water mixture & checking of connections complete servicing replacement of minor unserviceable parts such as rubber bushes, washers, mounting pad, Rubbers, Nuts & Bolts, clips etc and refixing the same after testing, complete all as specified and directed.\nNote : (a) Spare parts (other than minor )required for replacement and gas shall be measured and paid for separately under respective item of Schedule of Works.\n(b) The work under this item shall be excuted on emergency basis to avoid inconvinance to the users as directed by Engineer-in-Charge. In this connection condition 8 of IAFW-2249 also refers | 73 | Each Job | |
| 4 | 1.03 | Supply & refilling, refrigerant R-22 after testing, rectification of leakage in the system with brazing/welding, complete all as specified and directed | 200 | Each Job | |
| 5 | 1.04 | Supply & fix, liquid line strainer in repair, complete all as specified and directed | 100 | Each | |
| 6 | 1.05 | Supply & fixing, Thermostatic switch for air conditioner in repair, complete all as specified and directed. Make: Indfoss/Danfoss. | 100 | Each | |
| 7 | 1.06 | Supply & fix, PVC condenser fan blade in repair matching with existing type & mode, complete all as specified and directed. | 50 | Each | |
| 8 | 1.07 | Supply & fix, blower drum in repair matching with existing type & model, complete all as specified and directed. | 50 | Each | |
| 9 | 1.08 | Supply and fix, Fan Motor 1/5 HP single Phase 230 Volts complete with Base, nuts, bolts, & washers in repair to match with existing type and model, complete all as specified and directed. Make : AUE/Cool home/Universal/Crompton. | 60 | Each | |
| 10 | 1.09 | Supply & fix, air filter as per existing superior quality (Window type AC 1.5/2.0 ton) in replacement, complete as specified & directed. | 50 | Each Job | |
| 11 | 1.1 | Supply and fix, Condenser coil 4-row fins type in repair as per existing type & model, complete all as specified & directed. | 80 | Each Job | |
| 12 | 1.11 | Supply and fix, wiring kit in repair as per original specification with bronze thimbles and code marking, complete all as specified & directed. | 60 | Each Job | |
| 13 | 1.12 | Supply and fix, cooling coil in repair as per existing type and model, complete all as specified and directed. | 60 | Each Job | |
| 14 | 1.13 | Supply only, remote control electronic type suitable for 1.5 TR window type AC. \nMake : LG /Videocon/Voltas | 20 | Each Job | |
| 15 | 1.14 | M&L for PCB repair for 1.5/2 TR window type AC complete | 60 | Each Job | |
| 16 | 1.15 | Supply and fix, front grill of window AC capacity 1.5 Ton complete with knobs, PVC filter etc all as per sample including taking down old unserviceable, complete all as specified and directed. \nMake: Carrier/LG/Videocon | 60 | Each Job | |
| 17 | 2 | REPAIR TO SPLIT TYPE AIR CONDITIONERS 1.5/2 TR CAPACITY ANY MAKE AND MODEL | |||
| 18 | 2.01 | Dismantling & taking out unserviceable sealed unit from existing split type AC 1.5 ton capacity, supply and fix reciprocating/ rotary type new compressor including necessary brazing & cleaning of condenser/cooling coil, charging of compressor oil, Refrigerant R-22, including replacement of new Bushes, washers, mounting Rubbers, Nuts & Bolts, & testing, complete all as specified & directed. \nMake : LG/Emulsion Climate/Techumch/Carrrier/Videocon | 15 | Each Job | |
| 19 | 2.02 | Dismantling & taking out unserviceable sealed unit from existing split type AC 2.0 ton capacity, supply and fix reciprocating/rotary type new compressor including necessary brazing & cleaning of condenser/cooling coil, charging of compressor oil, Refrigerant R-22, including replacement of new Bushes, washers, mounting Rubbers, Nuts & Bolts., & testing complete. all as specified & directed. Make :LG/Emulsion Climate/Techumch/Carrier/Videocon | 15 | Each Job | |
| 20 | 2.03 | Dismantling & taking out Split type air conditioner of capacity 2.0/1.5 Ton of any make/type from its original location, carrying out maintenance/overhauling, greasing after cleaning thoroughly with vacuum cleaner, checking of connections, replacement of minor unserviceable parts such as rubber bushes, washers, mounting , Rubbers, Nuts & Bolts, clips etc and testing, complete all as specified and directed. \nNote : Spare parts required for replacement shall be measured and paid for separately | 207 | Each Job | |
| 21 | 2.04 | Supply & refilling, refrigerant R-22 after testing, rectification of leakage in the system with Nitrogen Gas, complete all as specified and directed. | 300 | Each Job | |
| 22 | 2.05 | Supply and fix, Contactor single-phase 230 Volts AC 40 Amps coil range 208/240 volts in repair, complete all as specified and directed. Make: USHA/SIEMENS/L&T | 100 | Each Job | |
| 23 | 2.06 | Supply and fix, Capacitor 4 MFD, AC 230 volts dry type in replacement, complete all as specified and directed. \nMake: Epcos/Bajaj/Usha/Uniston | 110 | Each Job | |
| 24 | 2.07 | Supply & fix, Fan Motor 1/8 HP single Phase 230 Volts complete with Box and fan blades in repair as per existing type and model for out door unit of make Carrier, complete all as specified and directed. | 50 | Each Job | |
| 25 | 2.08 | Supply & fix, blower motor 1/20 HP single Phase 230 Volts complete with Box and fan blades in repair as per existing type and model for out door unit of make Carrier, complete all as specified and directed. | 50 | Each Job | |
| 26 | 2.09 | Supply only, remote control electronic type suitable for 1.5/2.0 TR split type AC, complete all as specified and directed. \nMake : LG /Videocon/Voltas | 20 | Each Job | |
| 27 | 2.1 | Supply and fix, panel circuit board electronic for split AC 1.5/2.0 ton in replacement, complete all as specified and directed. | 50 | Each Job | |
| 28 | 2.11 | Supply and fix, Tee Valve of size 5/8? and 3/8? in repair, complete all as specified and directed. | 40 | Each Job | |
| 29 | 2.12 | Supply and fix, Tee valve of size 3/8? and 1/4? in replacement, complete all as specified and directed | 40 | Each Job | |
| 30 | 2.13 | Supply and fix, wiring kit in replacement as per original specification with bronze thimbles and code marking, complete all as specified & directed. | 50 | Each Job | |
| 31 | 3 | MISCELLENEOUS ITEMS FOR REPAIR TO WINDOW TYPE AND SPLIT TYPE ACs | |||
| 32 | 3.01 | Supply and fix, running capacitor 36 MFD, AC 230 volts grade in replacement, complete all as specified and directed. \nMake: Epcos/Usha/Unistar/Siemen | 50 | Each | |
| 33 | 3.02 | Supply and fix, running capacitor 45 MFD, AC 230 volts grade in replacement, complete all as specified and directed. \nMake: Epcos/Usha/Unistar/Siemen | 50 | Each | |
| 34 | 3.03 | Supply and fix, starting capacitor 100-120MFD in replacement, complete all as specified and directed. \nMake : KELTRON/ TESLA/SIEMEN/SPEED | 50 | Each | |
| 35 | 3.04 | Supply and fix, starting relay box type in replacement (suitable for off sizes split type ACs), complete all as specified and directed. Make: SHRIRAM/ RENUTRAL/Hi-Tech | 60 | Each | |
| 36 | 3.05 | Supply and fix, copper tubing size 5/8? including Gas welding and making Leak proof in replacement, complete all as specified and directed. | 250 | RM | |
| 37 | 3.06 | Supply and fix, copper tubing size 3/8? including Gas welding and making Leak proof in replacement, complete all as specified and directed | 250 | RM | |
| 38 | 3.07 | Material and labour, Black Foam 4mm thick and 50mm wide for insulating suction and discharge line, complete all as specified and directed. | 400 | RM | |
| 39 | 3.08 | Supply and fix, thermostatic switch in repair of split type air conditioner 1.5/2.0 TR, complete all as specified and directed. Make – Indfoss/Danfoss | 100 | Each job | |
| 40 | 3.09 | Supply and fix, plug top 15 Amps, 3 pin 230 Volts grade, complete all as specified and directed. \nMake : Anchor/SSK/Kalinga/Havells | 50 | Each job | |
| 41 | 4 | REPAIR TO WATER COOLER CAPACITY 150/120/80 LITRE ; MAKE : USHA/ VOLTAS/ SHRIRAM | |||
| 42 | 4.01 | Dismantling & taking out unserviceable sealed unit from existing water cooler capacity 150/120/80 Litre, Supply & fix new compressor including charging of compressor oil, Refrigerant R-22 upto required pressure including replacement of foundation bushes & Nuts/ bolts of existing size, complete all as specified and directed. | 10 | Each Job | |
| 43 | 4.02 | Supply and fix, Condenser fan motor 1/16 HP capacity with blade and Box plate in replacement, complete all as specified and directed. Make: AVE/Universal/Coolhome/Khaitan | 20 | Each Job | |
| 44 | 4.03 | Supply and fix, Condenser fan motor 1/10 HP capacity with blade and Box plate in replacement, complete all as specified and directed. Make: AVE/Universal/Coolhome/Khaitan | 15 | Each Job | |
| 45 | 4.04 | Supply and fix, Condenser fan motor 1/8 HP capacity AC 230 volts with blade and Box plate in replacement, complete all as specified and directed. Make: AVE/Universal/Coolhome/Khaitan | 20 | Each Job | |
| 46 | 4.05 | Supply & refilling, Refrigerant R-22 after testing, rectification of leakage in the system with Brazing/welding , complete all as specified and directed | 36 | Each Job | |
| 47 | 4.06 | Supply and fix, Push cock 15mm dia Chromium plated self closing (Heavy duty) in replacement as per existing size, complete all as specified and directed. Make: ARIHANT/BIR/LEADER | 12 | Each Job | |
| 48 | 4.07 | Supply & fixing, float valve 15mm dia bore high pressure complete with ball, brass rod, ISI Marked, in repair, complete all as specified and directed | 20 | Each Job | |
| 49 | 4.08 | Supply and fix, thermostatic switch for water coolers in repair, complete all as specified and directed. \nMake : Indfoss/Danfoss | 18 | Each Job | |
| 50 | 5 | REPAIR TO DESERT COOLERS 3000 /4000 CFM: The work under item 46 to 54 here-in- after shall be excuted on emergency basis to avoid inconvenience to the users as direted by Engineer-in-Charge. In this connection condition 08 of IAFW-2249 also refer | |||
| 51 | 5.01 | S&F fan motor 1/8 HP single phase 230 volts complete with legs, fan Blade, Nuts, Bolts & Washers etc including dismantling & taking out and removal unserviceable burnt fan motor, complete all as specified and directed. Make: Khaitan/Coolhome. | 300 | Each Job | |
| 52 | 5.02 | Supply & Fix, water lifting pump 1/70 HP AC single phase 230 Volts including taking out and removal unserviceable water lifting Pump, complete all as specified and directed.. Make: Khaitan/ Crompton. | 300 | Each Job | |
| 53 | 5.03 | Supply & fix, selector switch with knob (as per sample) in replacement, complete all as specified and directed. | 100 | Each Job | |
| 54 | 5.04 | Supply & fix, wood wool pads as per existing size and type in replacement, complete all as specified and directed | 500 | Each Set of 03 | |
| 55 | 5.05 | Supply and fix, PVC insulated copper conductor flexible cable of size 70/.0076, 3 core, in replacement, complete all as specified and directed. \nMake: Havells/Kalinga/Polycab/Gloster/Paragon | 500 | RM | |
| 56 | 5.06 | Supply and fix, PVC insulated copper conductor flexible cable of size 40/.0076, 3 core, in replacement, complete all as specified and directed.\nMake: Havells/Kalinga/Polycab/Gloster/Paragon | 200 | RM | |
| 57 | 5.07 | Supply and fix, front grill made out of PVC/GI sheet including selector switch, indication lamp fixed on GI front sheet 0.7mm thick, suitable for air flow capacity 3000/4000 CFM desert cooler including taking out old unserviceable front grill alongwith front sheet, complete all as specified and directed. | 40 | Each Job | |
| 58 | 5.08 | Supply and fix, Fan Blade as per requirement for desert cooler 3000/4000 CFM including taking out old unserviceable fan blade, complete all as specified and directed. | 50 | Each Job | |
| 59 | 5.09 | Supply and fix, PVC connection with complete accessories suitable for desert cooler 3000/4000 with flair nuts , PVC conector and washers, ISI marked suitable for 15mm bore complete all as specified and directed | 50 | Each Job | |
| 60 | 6 | REPAIR TO VOLTAGE STABILIZERS ANY MAKE AND MODEL | |||
| 61 | 6.01 | Supply, installation, testing and commissioning, voltage stabilizer of capacity 5KVA auto/manual operation single phase naturally air cooled and designed for input voltage of 160-280 volts with output stabilized at 220 Volts + 5% and having low and high cut off and intelligent delay relay, complete all as specified and directed.\nMake:- Carrier/Blue Star/Voltas | 10 | Each Job | |
| 62 | 6.02 | Supply, installation, testing and commissioning ,voltage stabilizer of capacity 4 KVA auto/manual operation single phase naturally air cooled and designed for input voltage of 160-280 volts with output stabilized at 220 Volts + 5% and having low and high cut off and intelligent delay relay, complete all as specified and directed.\nMake:- Carrier/Voltas/Blue Star | 10 | Each Job | |
| 63 | 7 | REPAIR/MAINTENANCE OF CENTRAL AC PLANTS | |||
| 64 | 7.01 | Supply, charging & testing leakage with nitrogen gas upto required pressure in central AC plants system, off sizes comprising of 3 units including rectification of leakage by means of gas welding and making system leak proof at any of the AC plants, complete all as specified and directed. Note : - The work should be done by auth compony rep . | 50 | Each Job | |
| 65 | 7.02 | Supply & charging, refrigerant Mafron-22 (R-22) brought at site in company sealed cylinder 61 Kgs capacity at any installation/AC plants, complete all as specified and directed by Engineer-in-Charge. \nNote: Empty cylinder shall be returned back as and when available with the department.\n | 400 | Kg | |
| 66 | 7.03 | Supply & charging, refrigerant R 407-C brought at site in company sealed cylinder 50 Kgs capacity at any installation/AC plants, complete all as specified and directed by Engineer-in-Charge. \nNote: Empty cylinder shall be returned back as and when available with the department.\n | 400 | Kg | |
| 67 | 7.04 | Supply & charging, compressor oil (Non freezing) in company sealed barrel of capacity 210 litres for (R-22) refrigerant AC plants, complete all as specified and directed. Make: Sheetal/Freezal-58/Caltese. | 300 | Litre | |
| 68 | 7.05 | Dismantling and opening both side cover of condenser comprising of 3 units and de-scaling of condenser of capacity 7.5 TR to 25 TR at any installation, by using concentrated HCL solution carefully and roding with brushes including replacement of rubber gasket & worn out nuts, bolts of condenser, complete all as specified & directed. Note : - The work should be done by auth compony rep . | 20 | Each Job | |
| 69 | 7.06 | Do all as per item No 61 above but of capacity 80 TR | 2 | Each | |
| 70 | 7.07 | Dismantling and opening of GI sheet ducting from AHU for cleaning/de-scaling complete with automatic cleaning system comprising of air compressor, vacuum unit, dust cleaning equipment. Note : - The work should be done by auth compony rep .\nNotes : \n(i) The cleaning of duct is to be started from AHU to different branches in different rooms. All the grills and diffusers are to be cleaned before re-fixing. Rate quoted shall also includes taking down of false ceiling as required and re-fixing the same and re-fixing of dismantled duct with proper clamps, nut, bolts all as specified and directed.\n(ii) The cleaning equipment shall have monitor, video camera etc for recording of complete cleaning process. The recording of complete cleaning process shall be stored and soft copy (DVD) of the same shall be handed over to the Engineer-in-Charge for record.\n | 200 | Sqm | |
| 71 | 7.08 | Dismantling and opening of cooling coil (AHU) at any installation complete for cleaning with acid solution, with circulating water pump etc, detection of leakage repair of damaged cooling coils tubes with necessary brazing after thorough cleaning etc complete and re-fixing the same, testing on load, complete all as specified and directed.Note : - The work should be done by auth compony rep . | 15 | Each Job | |
| 72 | 7.09 | Cleaning of Chiller water shell of chiller after dismantling of chiller water supply line with cleaning agent and reassembling of chiller shell, complete all as specified and directed.Note : - The work should be done by auth compony rep . | 10 | Each Job | |
| 73 | 7.1 | Supply and fixing, micro type filter synthetic non woven type, supported with aluminium and HDPE mesh having filter efficiency of 90% down to 10 micron of size 600 x 600x150mm (as per sample) including taking out old and removal, complete all as specified and directed. Make: Athlete/Universal. | 20 | Each | |
| 74 | 7.11 | Supply & fixing, LP cutout type, MP-I, complete all as specified and directed. \nMake: Danfoss/Indfoss/Ranco.\n | 4 | Each | |
| 75 | 7.12 | Supply & fixing, oil failure switch, type MP-55, complete all as specified and directed. \nMake: Danfoss/Indfoss/Ranco.\n | 4 | Each | |
| 76 | 7.13 | Supply & fixing, HP cut out, type MP-5, complete all as specified and directed.\n Make: Danfoss /Indfoss/Ranco.\n | 4 | Each | |
| 77 | 7.14 | Supply & fixing, LP/HP cut out, type MP-15, complete all as specified and directed.\nMake: Danfoss /Indfoss/Ranco.\n | 4 | Each | |
| 78 | 7.15 | Supply & fixing, thermostatic expansion valve type TCLE 7.5 HW, complete all as specified and directed. \nMake: Alco/Sporlon/Indfoss/Danfoss | 4 | Each | |
| 79 | 7.16 | Supply & fixing, V belt, A-28 in replacement, complete all as specified and directed. \nMake: Fenner/Dunlop | 40 | Each | |
| 80 | 7.17 | Supply & fixing, V belt, A-30 in replacement, complete all as specified and directed. \nMake: Fenner/Dunlop. | 40 | Each | |
| 81 | 7.18 | Supply & fixing, V belt, A-45 in replacement, complete all as specified and directed. \nMake: Fenner/Dunlop. | 40 | Each | |
| 82 | 7.19 | Supply & fixing, V belt, A-66 in replacement, complete all as specified and directed. \nMake: Fenner/Dunlop. | 40 | Each | |
| 83 | 7.2 | Supply & fixing, PVC fins suitable for ‘Delta’ cooling tower, any size and any type in replacement, complete all as specified and directed. | 1095 | Each | |
| 84 | 7.21 | Supply & fixing, solenoid valve, magnetic coil type, single phase, 230 Volts, suitable for R-22 refrigerant including taking out old and removal, complete all as specified and directed. \nMake: Sporlon/ALCO/Indfoss/Danfoss | 4 | Each | |
| 85 | 7.22 | Supply & fixing, contactor CA-3-30, 3 phase, 415 Volts, 45 Amps including taking out old and removal, complete all as specified and directed. Make: GE/L&T/Siemens. | 4 | Each | |
| 86 | 7.23 | Supply & fixing, relay type CT-3-12, range 1.6 to 2.5 Amps AC, 3 phase, 600 Volts including taking out old and removal, complete all as specified and directed. Make: GE/L&T/Siemens. | 4 | Each | |
| 87 | 7.24 | Supply & fixing, contactor MNX-12 Amps capacity, AC 3 phase 415 Volts, 50 Hz including taking out old and removal, complete all as specified and directed. \nMake: GE/L&T/Siemens\n | 3 | Each | |
| 88 | 7.25 | Supply & fixing, contactor MNX-25, AC 3 phase, 415 Volts, 50 Hz with standard coil including taking out old and removal, complete all as specified and directed. Make :GE/L&T/Siemens | 3 | Each | |
| 89 | 7.26 | Supply & fixing, contactor MNX-9, AC 3 phase, 415 Volts, 50 Hz with standard coil including taking out old and removal, complete all as specified and directed. Make: GE/L&T/Siemens | 3 | Each | |
| 90 | 7.27 | Supply & fixing , relay range 6 to 10 Amps, 415 Volts, 50 Hz including taking out old and removal, complete all as specified and directed. Make: GE/L&T/Siemens | 8 | Each | |
| 91 | 7.28 | Supply & fixing, contactor MO-A 1, AC 15Amps, 3 phase, 415 Volts including taking out old and removal, complete all as specified and directed. Make :GE/L&T/Siemens/Legrand\n | 3 | Each | |
| 92 | 7.29 | Supply & fixing, anti freeze thermostatic switch for chiller unit in replacement, complete all as specified and directed. \nMake: Danfoss/ Indfoss/Ranco. | 5 | Each | |
| 93 | 7.3 | Dismantling and taking out burnt electric motor of any make, type, RPM, 7.5 HP capacity, 3 phase 415 Volts, thoroughly cleaning and rewinding to stator with supper enameled copper wire of appropriate gauge including allied insulating material and varnishing of stator, replacement of front and rear bearings (as per sample) of the electric motor, re-fixing in position including electric connection and testing complete on load , complete all as specified and directed. | 5 | Each Job | |
| 94 | 7.31 | Dismantling and taking out burnt electric motor of any make, type, RPM, 5 HP capacity, 3 phase 415 Volts, thoroughly cleaning and rewinding to stator with supper enameled copper wire of appropriate gauge including allied insulating material and varnishing of stator, replacement of front and rear bearings (as per sample) of the electric motor, re-fixing in position including electric connection & testing complete on load, complete all as specified & directed. | 5 | Each Job | |
| 95 | 7.32 | Dismantling and taking out burnt electric motor of any make, type, RPM, 3 HP capacity, 3 phase 415 Volts, thoroughly cleaning and rewinding to stator with supper enameled copper wire of appropriate gauge including allied insulating material and varnishing of stator, replacement of front and rear bearings (as per sample) of the electric motor, re-fixing in position including electric connection and testing complete on load, complete all as specified and directed. | 6 | Each Job | |
| 96 | 7.33 | Dismantling and taking out burnt electric motor of any make, type, RPM, 1 HP capacity, 3 phase 415 Volts, thoroughly cleaning and rewinding to stator with supper enameled copper wire of appropriate gauge including allied insulating material and varnishing of stator, replacement of front and rear bearings (as per sample) of the electric motor, re-fixing in position including electric connection and testing complete on load, complete all as specified and directed. | 8 | Each Job | |
| 97 | 7.34 | Dismantling and taking out unserviceable condenser water pump and chiller water pump of capacity 3 HP/5 HP and overhauling complete by replacing the bushes, worn out impellor, gland packing, gland bolts, shaft nuts and greasing etc, complete all as specified and directed | 8 | Each Job | |
| 98 | 7.35 | Dismantling and taking out unserviceable condenser water pump and chiller water pump of capacity 7.5 HP/10 HP and overhauling complete by replacing the bushes, worn out impellor, gland packing, gland bolts, shaft nuts and greasing etc, complete all as specified and directed. | 4 | Each Job | |
| 99 | 7.36 | Supply and fixing in replacement, 3 pole power contactor type ML-1.5, standard voltage coil 230 Volts, 25 Amps capacity, complete all as specified and directed. Make: L&T/BCH/Siemens. | 6 | Each | |
| 100 | 7.37 | Supply and fixing in replacement, 3 pole power contactor, type ML-2, standard voltage coil 230 Volts, 32 Amps capacity, complete all as specified and directed. Make: L&T/BCH/Siemens. | 3 | Each | |
| 101 | 7.38 | Supply and fixing in replacement, 3 pole power contactor type, ML-3, standard voltage coil 230 Volts, 40Amps capacity, complete all as specified and directed. Make: L&T/BCH/Siemens.\n | 3 | Each | |
| 102 | 7.39 | Supply and fixing in replacement, Finned type strip heaters 2000 Watt, 240 Volts, complete all as specified and directed. \nMake: Daspass Cat Part No. FSH-20. | 40 | Each | |
| 103 | 7.4 | Supply and fixing in replacement, Finned type strip heaters, 3000 Watt, 240 Volt, complete all as specified and directed. Make: Daspass Cat Part No. FSH-30. | 40 | Each | |
| 104 | 7.41 | Material & labour, repair to cooling tower of capacity 15 TR to 20 TR including replacement of sprinkle assembly of size 2\"/3\" with PVC branch distribution pipe etc. complete with cleaning of collector tank etc, complete all as specified and directed. | 5 | Each Job | |
| 105 | 7.42 | Material & labour, repair to cooling tower of capacity 25 TR to 50 TR including replacement of sprinkle assembly of size 2\"/3\" with PVC branch distribution pipe etc complete with cleaning of collector tank etc., complete all as specified and directed. | 5 | Each Job | |
| 106 | 7.43 | Supply & fixing, blower motorpakage type 1 HP(960 RPM) with assy for AC Plants (Make: Delta). Incluing dismentling, taking out old & removal,, complete all as specified and directed. | 4 | Each | |
| 107 | 7.44 | Supply and fixing Compressor 8.75 Tr for AC plant Make : Emerson (Model No. ZR108KC-TFD-522) including taking out old & removal,, complete all as specified and directed. | 5 | Each | |
| 108 | 7.45 | Supply and fixing in replacement Compressor 5.5 Tr for AC plant Make : Emerson (Model No. ZR72KCE-TFD-522) including taking out old & removal,, complete all as specified and directed. | 2 | Each | |
| 109 | 7.46 | Supply and fixing in replacement Compressor 12 Tr for AC plant Make : Voltas (Model As per existing model installed at base Ops) including taking out old & removal,, complete all as specified and directed. | 2 | Each | |
| 110 | 7.47 | Supply and fixing in replacement Compressor 10 Tr for AC plant Make : Daikin (Model As per existing model installed at base Ops) including taking out old & removal,, complete all as specified and directed. | 2 | Each | |
| 111 | 7.48 | Supply & fixing in replacement, micro filter of size 23.5\"x 15\"of thickness as per existing , complete all as specified and directed. | 4 | Each | |
| 112 | 7.49 | Supply & fixing in replacement, micro filter of size 25?x25?of thickness as per existing , complete all as specified and directed. | 6 | Each | |
| 113 | 7.5 | Supply & fixing in replacement, humidistat indoor type of range 0-90, complete all as specified and directed. Make: Honey bell/Dass Pass/Armco. | 7 | Each | |
| 114 | 7.51 | Supply & fixing in replacement, thermostat having range 0-120, complete all as specified and directed. | 5 | Each | |
| 115 | 7.52 | Supply & fixing in replacement, MCCB ,3 pole, capacity 125 Amps, 415 volts, AC having rupturing capacity 16 KA, complete all as specified and directed. Make: LEGRAND/ABB/GE/L&T/SIEMENS/SCHNEIDER | 12 | Each | |
| 116 | 7.53 | Supply & fixing in replacement, MCCB ,3 pole, capacity 100 Amps, 415 volts, AC having rupturing capacity 16 KA, complete all as specified and directed. Make: LEGRAND/ABB/GE/L&T/SIEMENS/SCHNEIDER | 12 | Each | |
| 117 | 7.54 | Supply & fixing in replacement, MCCB ,3 pole, capacity 200 Amps, 415 volts, AC having rupturing capacity 36 KA, complete all as specified and directed. Make: LEGRAND/ABB/GE/L&T/SIEMENS/SCHNEIDER | 12 | Each | |
| 118 | 7.55 | Supply & fixing in replacement, MCCB ,3 pole, capacity 63 Amps, 415 volts, AC having rupturing capacity 16 KA, complete all as specified and directed. Make: LEGRAND/ABB/GE/L&T/SIEMENS/SCHNEIDER | 12 | Each | |
| 119 | 7.56 | Supply & fixing MCB, 40 Amps, 3 phase, TP, 415 Volts, AC 50 Hz, with rupturing capacity 9 KA including taking out old and removal, complete all as specified and directed. Make: LEGRAND/ABB/GE/L&T/Siemens/Schneider/Havells/Indiasian. | 10 | Each | |
| 120 | 7.57 | S&F sheet metal incl single pole and neutal with 02 pin and earth plug and shocket complete with 01 single pole 20 Amps 240 volts, MCB complete incl necessary fixing arrangement and all incoming and outgoing electric connection as as specified as directed by Engr-in-Charge. Make: Legrand/Havells/ABB.\n | 50 | Each | |
| 121 | 7.58 | Material & Labour for Sub Main Wiring with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in and including PVC concealed conduit 25mm dia with and including 1 run single core 4 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge.( 02 run of single core cable and 1 run single core of earth wire will measured as one unit). Make: Finolex/ Havells /Standard. | 300 | RM | |
| 122 | 7.59 | Supply and Fixing 3 Pin 20 Amp. AC top made of aluminum suitable for window/split type AC complete all as specified.\n | 100 | Each | |
| 123 | 7.6 | M&L for fabrication of angle iron stand maid out of 35mm x 35mm x 5mm angle iron of size (Approx) 27\" and 43\" height complete diagonalily braced with MS flat iron (25\" x 3\" ) suitable for positioning the desert cooler including painting with two coat of (blac) enameled paint over a coat of red oxide primer including all as specified and directed by the EIC | 30 | Each\n Job | |
| 124 | 7.61 | Taking out defective /perished hard board any size from window frame and S&F 3mm thick hard bed suitable for 450mm/500mm sweep desert cooler all as specified and directed. | 55 | Each\n Job | |
| 125 | 7.62 | S&F in repairs of set of panels made out of PGI sheet 22 gauge thick with wood wool pads, in required quantity duly filled complete as per sample and all as directed by EIC | 60 | Each (Set of three) | |
| 126 | 7.63 | Marerial and labour for shifting of WIndow AC's any make/capacity from any height & location and refix the same on another location after making necessary cutting on wall/roof/window/glass/grills as per requirement of users, complete all as specified and as directed.(Note:- Necessary insulation for copper tubing,gas filling,ply work shall be measured and paid seperately under respective item). | 30 | Each Job | |
| 127 | 7.64 | All as per above Item No. 7.63 but for Split AC's of any make/ capacity all as specified and directed. | 12 | Each Job | |
| 128 | 7.65 | Replacement of unserviceable of desert cooler body made of 20 gauge PGI sheet suitable for evaporative type desert cooler of size 73x73x93 cm including side panel - 03 Nos with 20 gause PGI sheet and water tank height 20 cm & grill with fins electrical wiring and connection with ON/OFF switch piano type with distribution PVC cup and elbow PVC pipe connection , PVC cable 3 core 23/.0076 - 3 Mtr with top plug 5 Amps - 01 No including duly painted complete body internally and externally and all side panel inner and outer side with two coat with synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and as directed. \n | 30 | Each Job | |
| 129 | 7.66 | Scarpping of old painted surfaces of central type AC plant of any capacity,M&L for spray painting with approved colour after preparing all equipments for smooth surfaces of compressor,condensor,monoblock pumps,compressor motors,motor starter,LT panel boards,water supply pipe lines,cooling tower,supply and discharge lines,liquid lines,AHUs etc including all connected accessories and marking of refrigerant system,water supply system etc with approved colour and marking of SM/MES nos with black enamelled paint of approved size and marking of incomng/outgoing electrical connection on LT panel board,operator room,glow sign boards of AC plant with approved colour on blue back ground all as directed at site by EIC. | 10 | Each Job | |
| 130 | 7.67 | Repairing /Replaccing the AC Plant panel boards of different capacities/location with lugs/thimbles/wires/winding/painting/braging/cement work/MCCB cover and by supply and replacing the following parts item no. 7.68 to 7.71 complete all as specified and as directed. | 6 | Each | |
| 131 | 7.68 | Ammeter 0-50 Amp, CT type size 96 sq mm square. | 4 | Each | |
| 132 | 7.69 | Voltmeter 0 - 500 Volt, size 96 sq mm. | 4 | Each | |
| 133 | 7.7 | Indicator lamps 230 Volt. | 8 | Each | |
| 134 | 7.71 | Selector switch as per sample complete assembly. | 6 | Each | |
| 135 | 7.72 | Earthing complete all as shown on electrical plate No 3 of MES schedule part-I, as specified & as directed including the following :-\n(i) Galvanised steel earth plate of size 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.50 metres below ground level. \n(ii) Earth plate surrounded by and packed with char-coal and comoan slft in alternative layers (n.exc 15cms each layer).\n(iii) 32x6mm G.I strip from earth plate to feeder pillar including necessary GI bolts, nuts check nuts, washers, thimbles etc. | 15 | Each Job | |
| 136 | 7.73 | Dismanting and taking out burnt electric motor of any make, type, RPM, 15 HP capacity 3 phase 415 volts, thoroughly cleaning and rewinding to stator with super enemeled copper wire of appropriate gauge including allied insulating material and varnishing of stator replacement of front and rear bearings (asper sample) of the electric motor, re-fixing in position including electric connection and testing complete on load, complete all as specified and directed. | 10 | Each Job | |
| 137 | 7.74 | S&F in replacement Condenser pump motor 7.5 HP 3 phase as per the existing make and model suitable for the AC plant located at site of Make Voltas. | 4 | Each | |
| 138 | 7.75 | S&F in replacement Condenser pump motor 5 HP 3 phase as per the existing make and model suitable for the AC plant located at site of Make Voltas. | 5 | Each | |
| 139 | 7.76 | S&F in replacement Condenser pump motor 3 HP 3 phase as per the existing make and model suitable for the AC plant located at site of Make Voltas. | 4 | Each | |
| 140 | 7.77 | S&F in replacement Condenser pump motor 2 HP 3 phase as per the existing make and model suitable for the AC plant located at site of Make Voltas. | 4 | Each | |
| 141 | 7.78 | S&F in replacement Cooling Tower fan motor 3 HP 3 Phase suitable for existing cooling tower of cap 8.75 TR AC Plant of Make Voltas. | 4 | Each | |
| 142 | 7.79 | S&F in replacement AHU motor (Blower motor) 3 HP 3 Phase suitable for existing AHU of cap 8.75 TR AC Plant of Make Voltas. Make CG or equivalent. | 4 | Each | |
| 143 | 7.8 | S&F in replacement Cooling Tower fan motor 5 HP 3 Phase suitable for existing cooling tower of cap 48 TR AC Plant of Make Voltas. | 2 | Each | |
| 144 | 7.81 | S&F in replacement AHU motor (Blower motor) 7.5 HP 3 Phase suitable for existing AHU of cap 48TR AC Plant of Make Voltas installed at Base Ops. | 2 | Each | |
| 145 | 7.82 | S&F in replacement Sprinkler Assembly for coolimg tower as per existing plant of Make Voltas suitable for existing location of AC plant of Make Voltas 8.75 TR installed at PMSI and PMS-II | 2 | Each | |
| 146 | 7.83 | S&F in replacement Sprinkler Assembly for coolimg tower as per existing plant of Make Voltas suitable for existing location of AC plant of Make Voltas 48TR installed at Base Ops. | 1 | Each | |
| 147 | 7.84 | S&F in replacement Sprinkler Assembly for coolimg tower as per existing plant of Make Voltas suitable for existing location of AC plant of Make Daikin 80 TR installed at New ATC. | 1 | Each | |
| 148 | 7.85 | Note:- Amount of credit of Rs. 142485.00 for retrieved materials is mentioned in Schedule of Credit Page No 108 to 110 of tender documents in pdf form which will be deducted offline while acceptance of tender. |