Repairs And Maint Of Security/Perimeter Lights/High Mast Lights/Solar Lights/Garden Lights And Connected Items At Rayang Mil Stn Under Ge 872 Ews, RAYANG-Arunachal Pradesh

Military Engineer Services-MES has published Repairs And Maint Of Security/Perimeter Lights/High Mast Lights/Solar Lights/Garden Lights And Connected Items At Rayang Mil Stn Under Ge 872 Ews. Submission Date for this Tender is 09-06-2021. Tube Light Tenders in RAYANG Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27904935
Corrigendum : Repairs And Maint Of Security/Perimeter Lights/High Mast Lights/Solar Lights/Garden Lights And Connected Items At Rayang Mil Stn Under Ge 872 Ews
National Competitive Bid
Indian
Arunachal Pradesh
RAYANG
09-06-2021

Tender Details

Repairs And Maint Of Security/Perimeter Lights/High Mast Lights/Solar Lights/Garden Lights And Connected Items At Rayang Mil Stn Under Ge 872 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-May-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-06-2021
2 05-Jun-2021 DATE Date 09-06-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 16000.0 /-
Tender Value
INR 8 Lakhs /-

BOQ Items

NAME OF WORK : REPAIRS & MAINT OF SECURITY/ PERIMETER LIGHTS/ HIGH MAST LIGHTS/ SOLAR LIGHTS/ GARDEN LIGHTS & CONNECTED ITEMS AT RAYANG MIL STN UNDER GE 872 EWS
Sl. No. Item Description Item Code / Make Quantity UNITS
1 1 M&L Taking down Street/Perimeter Light Fitting of any descriptions from any Height after disconnecting, Opening Cover and Checking of Light Fitting, Repairing as required, Re-fixing the Light Fitting after repaired in Original Position and Providing Connections including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed.\nNOTE :-\n(a) Cost of Minor Parts/ Spares such as Wiring Wires, Mild Steel Bolts, Nuts & Washers deemed to be included in the Quoted Unit Rate.\n(b) New Spares/Parts (Quantites are Provisional) will be Measured and Paid separately under respective Items as 'Supply only'. BI01010001010000000000000515BI0100001113 30 EACH JOB
2 2 Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 30 Watt, complete all as specified and as directed. BI01010001010000000000000515BI0100001114 5 EACH
3 3 Supply only Driver (as approved) suitable for LED Street Light Fitting 45 Watt, complete all as specified and as directed. BI01010001010000000000000515BI0100001115 6 EACH
4 4 M&L Lowering down High Mast Lights, Repairing High Mast Light by apply Greasing, Oiling, etc., Repairing as required, Re-hoisting High Mast Lights after Repaired including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed.\nNOTE : New Spares/Parts (Quantites are Provisional) will be Measured and Paid separately under respective Items as 'Supply only'. BI01010001010000000000000515BI0100001116 2 EACH JOB
5 5 Supply only Driver (as approved) suitable for LED Flood Light Fitting 120 Watt, complete all as specified and as directed. BI01010001010000000000000515BI0100001117 20 EACH
6 6 Supply only LED Flood Light 1x120 Watt (as approved), complete all as specified and as directed. BI01010001010000000000000515BI0100001118 4 EACH
7 7 M&L Taking down Solar Light Fitting of any type and any capacity from any Height, Replacing Defective/ Unserviceable Spares/ Parts, Applying Mineral Jelly to the Battery Terminal(s), Tightening of All Connections, Cleaning of Solar Panel throughly, Filling Distilled Water to Solar Light Batteries, Re-fixing the Solar Light Fitting in Original Position, complete all as specified and as directed.\nNOTE : New Spares/Parts (Quantites are Provisional), Distilled Water, etc. will be Measured and Paid separately under respective Items as 'Supply only' BI01010001010000000000000515BI0100001119 12 EACH JOB
8 8 Supply only Tinned/ Copper Battery Terminal (as approved), complete all as specified and as directed. BI01010001010000000000000515BI0100001120 10 EACH
9 9 Supply only Solar Battery 12 Volt, 75 AH, Dry Gel (as approved) suitable for 3 Days Backup capacity, complete all as specified and as directed. BI01010001010000000000000515BI0100001121 2 EACH
10 10 Supply only Distilled Water suitable for Solar Light Batteries, complete all as specified and as directed. BI01010001010000000000000515BI0100001122 60 LITRE
11 11 S&F LED Street Light Fitting 30 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELLS/ PHILIPS (as approved by GE) BI01010001010000000000000515BI0100001123 15 EACH
12 12 S&F LED Street Light Fitting 45 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELLS/ PHILIPS (as approved by GE) BI01010001010000000000000515BI0100001124 19 EACH
13 13 S&F Flood Light 50 Watt Luminaire with High Power COB LED as Light Source, Energy Saving, IP-65 Protectd complete with all Accessories, IP-65 protected, Providing Electric Connections including Taking down unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELLS/ PHILIPS (as approved by GE) BI01010001010000000000000515BI0100001125 2 EACH
14 14 M&L Street Light Fitting Bracket made out from GI Pipe 40mm Bore (dia), Light Grade, not exc. 1.20 Metre long, bend to required shape and fixing to Poles, etc. with and including Mild Steel Flat Iron Clamps 40x5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc. including Painting with One coat of Red Oxide Zinc Chrome Primer and Two coats of Aluminium Paint to all Mild Steel Works including Taking down Unserviceable Street Light Fitting Bracket of any description from any Height, complete all as specified and as directed. BI01010001010000000000000515BI0100001126 20 EACH JOB
15 15 S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 310x210x120mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. and duly Painted on Both Sides with Two Coats of Synthetic Enemel Paint over a Coat of Red Oxide Zinc Chrome Primer including Taking down Unserviceable Pole Box of any description from any Height, complete all as specified and as directed.\nMAKE : HENSEL/ SCHNEIDER/ SINTEX/ UNIVERSAL SWITCH GEARS CONTROL or as approved by GE. BI01010001010000000000000515BI0100001127 1 EACH JOB
16 16 S&F Street Light Digital Timer, comprising of Incoming Cable Terminals, MCBs, Timer, Contactor, Outgoing Terminal duly Pre-wired and all Accessories, housed in Mild Steel Box, Outdoor type of capacity 40 Amp, TPN, 3 Pole, 230 Volt having Contactor rating 32 Amp, TP, Providing necessary Connection and Testing including Taking down Unserviceable Timer of any description from any Height, complete all as specified and as directed.\nMAKE : HAVELLS, Cat No. IHXTS03060 or equivalent Model in Make : BAJAJ/ L&T /SIEMEN (as approved by GE) BI01010001010000000000000515BI0100001128 1 EACH
17 17 M&L Taking down existing Unserviceable Garden Light Fitting of any description from 3.00 Metre Pole after disconnecting, Opening Cover and Checking the Light Fitting, Carry out necessary Repairing including Changing of Defetive Parts, Refixing the repaired Garden Light Fitting in Existing Position and Testing, complete all as specified and directed.\nNOTE :-\n(a) Cost of Minor Parts/Spares such as Wiring Wires, Mild Steel Bolts, Nuts, Washers, etc. deemed to be included in the Quoted Unit Rate.\n(b) New Parts/ Spares will be Measured and Paid for seperately under appropriate Items. BI01010001010000000000000515BI0100001129 4 EACH JOB
18 18 S&F BAMBOO Light Fitting, New Generation, Environmental Friendly, Energy Saving, Long Life, Aesthetically Designed, Aluminium Landscape Luminaire for Diffused Lighting with High Power LED as Light Source, IP-65 protected, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELLS, Cat No. BAMBOOBL8WLED830SSYMTOPCM (1.0 M) or equivalent Model in Make : BAJAJ/ CG/ C&S/ PHILIPS as approved by GE BI01010001010000000000000515BI0100001130 8 EACH
19 19 S&F Globe shaped LED Post Top Lantern Fitting 20 Watt in Frosted Finish made up of Polycarbonate suitable for LED Lamp (B-22 base) complete with all Accessories with LED Lamp 20 Watt and Providing Connection including Taking down Unserviceable Post Top Lantern Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELLS, Cat No. LHFXBON1TN5Q020 or equivalent Model in Make : BAJAJ/ CG/ C&S/ PHILIPS (as approved by GE) BI01010001010000000000000515BI0100001131 4 EACH
20 20 S&F LED Post Top Fitting 25 Watt, Energy Saving, Environmental Friendly, Long Life, Asthetically designed with Symmetrical Light Distribution, Spun, Aluminium Landscape Luminare, IP-65 Protection with High Power LED as Light Source including Lamp 25 Watt, Providing necessary Electrical Connection including Taking down unserviceable Post Top Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELLS, Cat No. CORALPT25WLED757PSYMTOPC or equivalent Model in Make : BAJAJ/ CG/ C&S/ PHILIPS (as approved by GE) BI01010001010000000000000515BI0100001132 2 EACH
21 21 M&L PVC Insulated, Multi-stranded, FRLS Copper Conductor Cable of size 1.0 Sqmm 3 Core, fixing from Fitting to Junction Box, complete all as specified and as directed. BI01010001010000000000000515BI0100001133 90 RUNNING METRE
22 22 Dismantling Unserviceable LT Steel Tubular Pole of any description and any size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed.\nNOTE: Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately. BI01010001010000000000000515BI0100001134 3 EACH JOB
23 23 Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed. BI01010001010000000000000515BI0100001135 0.5 QUINTAL
24 24 Taking down ACSR Conductor of any size including Line Spacers of OH Electric Lines from LT Electric Poles, complete all as specified and as directed. BI01010001010000000000000515BI0100001136 0.5 QUINTAL
25 25 Disconnecting & Taking down/out carefully Defective LT Cable of any size and any descriptions from Trenches, Floors, Walls, GI Pipes, etc. after tracing Cable Fault including Serviceable (if any) Cables, Bricks/Cable Protection Cover, etc. keep in Safe Custody for re-use, complete all as specified and as directed.\nNOTE : Necessary Earth Works will be Measured & Paid under appropriate Items. BI01010001010000000000000515BI0100001137 180 RUNNING METRE
26 26 Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable, Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed. BI01010001010000000000000515BI0100001138 40.5 CUBIC METRE
27 27 Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Metre for Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed. BI01010001010000000000000515BI0100001139 0.5 CUBIC METRE
28 28 Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed. BI01010001010000000000000515BI0100001140 6 CUBIC METRE
29 29 Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed. BI01010001010000000000000515BI0100001141 35 CUBIC METRE
30 30 Drilling/Making Hole (Horizontally) under Roads/ Hardstanding, etc. by any means suitable for passing GI Tubing 40mm to 80mm bore (dia), complete all as specified and as directed. BI01010001010000000000000515BI0100001142 10 RUNNING METRE
31 31 M&L Cutting Existing Road not exc. 1.50 Metre in depth and not exc. 1.50 Metre wide including Making Good the same to match the Original Surface level with Cement Concrete after laying of Cables, Well Ramming and leveling in layers, etc., complete all as specified and as directed.\nNOTE : Cement Concrete will be Measured and Paid separtely under appropriate Item. BI01010001010000000000000515BI0100001143 14 RUNNING METRE
32 32 M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.\nNOTE : Cost of Formwork will deem to be include in the Quoted Unit Rate. BI01010001010000000000000515BI0100001144 0.3 CUBIC METRE
33 33 M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.\nNOTE : Cost of Formwork will deem to be include in the Quoted Unit Rate. BI01010001010000000000000515BI0100001145 0.5 CUBIC METRE
34 34 M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc., Weathering slightly Rounded or Chamfered Angle and Throating, Finishing all Exposed Faces of Concrete including necessary Formwork, complete all as specified and as directed.\nNOTE : Cost of Formwork will deem to be include in the Quoted Unit Rate. BI01010001010000000000000515BI0100001146 0.2 CUBIC METRE
35 35 M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed.\nNOTE : Necessary Earth Work & Cement Concrete will be Measured and Paid separately under relevent Items. BI01010001010000000000000515BI0100001147 3 EACH JOB
36 36 M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and applying Two coats of Aluminium Paint over a coat of Red Oxide Zinc Chromium Primer after preparation of Surfaces, complete all as specified and as directed. BI01010001010000000000000515BI0100001148 0.5 QUINTAL
37 37 S&F Insulator Pin type, 100mm height, 65mm dia Porcelain, Vitreous, White, Brown or Green for 1100 Volt grade including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut including Taking down unserviceable Insulator, complete all as specified and as directed. BI01010001010000000000000515BI0100001149 5 EACH
38 38 S&F Insulator Shackle type, Porcelain, Vitreious, white brown or green of size 100mm High & 115mm dia including Galvanised Mild Steel Straps of Section 31x5.0mm, 14mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 1100 Volt grade including Taking down unserviceable Insulator, complete all as specified and as directed. BI01010001010000000000000515BI0100001150 5 EACH
39 39 M&L ACSR Conductor of any size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed.\nNOTE : Sizes of Conductor will be as per Site requirement as directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001151 0.5 QUINTAL
40 40 S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 3/4-Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed. BI01010001010000000000000515BI0100001152 10 EACH
41 41 S&F MCCB 40 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz with Thermal Magnetic Trip Unit and fixing in any Situation including Taking down/out unserviceable MCCB, complete all as specified and as directed.\nMAKE : ABB/ LEGRAND/ SCHNEIDER/ SIEMENS (as approved by GE) BI01010001010000000000000515BI0100001153 1 EACH
42 42 S&F MCCB 100 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz with Thermal Magnetic Trip Unit and fixing in any Situation including Taking down/out unserviceable MCCB, complete all as specified and as directed.\nMAKE : ABB/ LEGRAND/ SCHNEIDER/ SIEMENS (as approved by GE) BI01010001010000000000000515BI0100001154 1 EACH
43 43 S&F MCCB 200 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz with Thermal Magnetic Trip Unit and fixing in any Situation including Taking down/out unserviceable MCCB, complete all as specified and as directed.\nMAKE : ABB/ LEGRAND/ SCHNEIDER/ SIEMENS (as approved by GE) BI01010001010000000000000515BI0100001155 2 EACH
44 44 S&F On Load Change Over Switch (Front Operated) Open Execution, 100 Amp rating, 4 Pole, 415 Volt, fixing in any Situation and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed.\nMAKE : LEGRAND, Cat Part No. CSCS100NM4CO or equivalent Model in Make : ABB/ SCHNEIDER/ SIEMENS (as approved by GE) BI01010001010000000000000515BI0100001156 1 EACH
45 45 M&L Preparing Surfaces of LT Steel Tubular Pole 8.5/9.0 Metre high for 1.50 Metre above PCC Coping including GI Bracket, Cross Arms, Channel, Flat Iron Clamps, etc. and applying with One coat of Aluminium Paint (Superior quality) and Bottom 1.50 Metre portion of Pole Painting with Strips 300mm high (5 Nos.) around the Pole with Two different Colour Synthetic Enamelled Paint (Black and Yellow) in alternate Strips, Writing Pole No. in 50mm high/ size Letters/Numbers with Black Paints, complete all as specified and as directed. BI01010001010000000000000515BI0100001157 120 EACH JOB
46 46 Supply & Laying XLPE Insulated, Armoured, Heavy duty Electric Cable with Aluminium Conductor 1100 Volt grade, Cross-sectional Area 25 Sqmm 4 Core, laid in Tenches or fixing to Electric Poles or Passing through Pipes/along Walls/ Roof/ across Drains/ Culvert, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. BI01010001010000000000000515BI0100001158 50 RUNNING METRE
47 47 Supply & Laying XLPE insulated, PVC sheathed, Heavy duty, armoured with multi-stranded Aluminium Conductor Electric Cable, 1100 Volt grade, having Cross-sectional Area 70 Sqmm 3½ Core, conforming to IS:7098 (Part-1), laid in Tenches or fixing to Electric Poles or Passing through Pipes/ along Walls/ Roof/ across Drains/ Culvert, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items BI01010001010000000000000515BI0100001159 60 RUNNING METRE
48 48 Supply & Laying XLPE insulated, PVC sheathed, Heavy duty, armoured with multi-stranded Aluminium Conductor Electric Cable, 1100 Volt grade, having Cross-sectional Area 120 Sqmm 3½ Core, conforming to IS:7098 (Part-1), laid in Tenches or fixing to Electric Poles or Passing through Pipes/ along Walls/ Roof/ across Drains/ Culvert, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items BI01010001010000000000000515BI0100001160 70 RUNNING METRE
49 49 M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.\nNOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured. BI01010001010000000000000515BI0100001161 12.15 CUBIC METRE
50 50 Supply & Laying Unreinforced Pre-cast Concrete Cable Cover of size 300x180x40mm thick, Class LV, Type 2, Flat, Concrete grade M-20 minimum, complete all as specified and as directed. BI01010001010000000000000515BI0100001162 900 EACH
51 51 M&L Galvanised Steel Tubing Pipe 40mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed. BI01010001010000000000000515BI0100001163 10 RUNNING METRE
52 52 M&L Galvanised Steel Tubing Pipe 50mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed. BI01010001010000000000000515BI0100001164 10 RUNNING METRE
53 53 M&L Factory made Outdoor type Panel, made out of 16 SWG CRCA Sheet, Powder Coated, Weather Proof, Front Opening Shutter with proper Locking Arrangements, suitable for Totally Enclosed complete and grouting in Cement Concrete 1:2:4 (20mm graded stone aggregate) Work of suitable size including necessary Electric Connections and Testing, Comprising with the followings including Taking down unserviceable Panel, complete all as specified and as directed:-\n(a) Copper Bus-bar 4 Strip, 450mm long, 100 Amp, 415 Volt - 01 Set\n(b) MCB 32 Amp, TP, 25 kA, 230 Volt - 03 No. \n(c) MCB 63 Amp, TPN, 4 Pole, 25 kA, 415 Volt - 01 No. BI01010001010000000000000515BI0100001165 1 EACH JOB
54 54 M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.5 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. BI01010001010000000000000515BI0100001166 1 EACH SET
55 55 M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. \nNOTE : All Joints should be joined by Exothermic Welding or Brazing. BI01010001010000000000000515BI0100001167 1 EACH SET
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy