Housing Urban and Rular Development Government Departments Closing in 0 days TDR #27901822

Special Repair Of General Hospital At Meham In Rohtak District

Issued by Government Departments · Meham, Haryana
Tender Value
91.89 Lakhs
Estimated cost
Bid Submission
03 Jun 2021
0 days left
EMD
1.84 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Meham → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Special Repair Of General Hospital At Meham In Rohtak District

BOQ

Name of Work: Special repair of General Hospital at Meham in Rohtak District
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres. (HSR 6.6)685.68Cum
22Dismantling Brick Work, Tile Masonry or Tile Lining and Tile Terracing. (b) In cement. (HSR 8.5 b)58.78Cum
33Dismantling Concrete. (e) reinforced cement concrete with cleaning and straghtening and cutting of bars if required. (HSR 8.6 e)25.57Cum
44Removing door and windows (wood and steel) with chowkats by making Recesses in walls when the wall is not to be dismantled:- (HSR 8.18)
55Door103Nos.
66Windows104Nos.
77Ventilator158Nos.
88Removing rolling, shutters including top cover, brackets and side guides etc Complete. (HSR 8.24)4.18Sqm
99Dismantling cement eonglomerate/ terrazzo floor 25 mm to 50 mm thick without concrete base. (HSR 8.26)356.27Sqm
1010Scraping. (a) White wash and colour wash. (HSR 8.32 a)4611.37Sqm
1111Scraping. (c) Cement plaster. (HSR 8.32 c)735.12Sqm
1212Dismantling white or coloured glazed tiles (to be carefylly removed). (HSR 8.38)197.07Sqm
1313Cement concrete 1 : 8 : 16 with stone aggregate 40mm Nominal size in foundation and plinth. (HSR 10.28)89.92Cum
1414Cement concrete 1: 2 : 4 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.41)4.72Cum
1515Cement concrete 1:1.5:3 with stone aggregate 20mm nominal size for reinforced concrete work for walls exceeding 20cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects. (HSR 10.86 + 10.95 (a)119.8Cum
1616Cement concrete 1:1.5:3 with stone aggregate 20mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc., excluding steel reinforcement and including centring & shuttering, laid in position complete in all respects (for work upto 1.5 metres below ground level). (HSR 10.90 + 10.95 (a)181.74Cum
1717First class bricks work laid in cement sand mortar 1:4 in foundation and plinth (HSR 11.4)179.03Cum
1818First class brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. (HSR 11.9)\n(a) Ground floor186.09Cum
1919First floor13.01Cum
2020Second floor4.64Cum
2121Terracing consisting of tiles 22.86cm x 11.43cm x 3.81cm, laid over 87.50 mm mud filling on a layer of 25mm mud plaster and another layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 Kg per Sqm on top of R.C.C. slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13)1236.27Sqm
2222Top khurra 0.6 m X 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16. (HSR 13.50)30Nos.
2323Cement concrete 1:2:4 gola 10 cm X 10 cm quardrant along junction of roof with parapet wall finished smooth, where specially specified. (HSR 13.64)482.88Mtr.
2424Conglomerate floor 25mm thick cement concrete topping 1:2:4. (HSR 14.8)118.72Sqm
2525Conglomerate floor 40 mm thick cement concrete topping 1:2:4. (HSR 14.9)108.48Sqm
2626Kotah Stone flooring, minimum 25mm thick, in any pattern as specified over 20mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing. (HSR 14.62)65.03Sqm
2727Providing & fixing Vitrified Tiles 600 x 600mm of approved make in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and joint will be 4 mm wide instead of zero joint by using spacers to ensure uniformity of joint duly filled with epoxy grout minimum depth upto the thickness of tile of reputed make such as pidilite (T-13 Roff), Mapaie, Laticrete, Ardex Endura, as approved by Engineer-in-charge. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL, SIMPOLO. (Double charged tiles shall be used as approved by Engineer-in-charge. (NS)\nNote:- The agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.186.11Sqm
2828Providing & fixing 1st quality ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manufacturer) of approved make in all colors, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete. (b) Size of ceramic Glazed Tiles 300 x 450mm. (HSR 14.92 b)539.61Sqm
292912mm thick cement plaster 1:6. (HSR 15.7)
3030Ground floor2167.34Sqm
3131First floor367.94Sqm
3232Second floor87.94Sqm
333315mm thick cement plaster 1:6 on the rough side of single of half brick wall. (HSR 15.12)
3434Ground floor2167.34Sqm
3535First floor303.55Sqm
3636Second floor106Sqm
3737Cement pointing 1:2 deep variety on brick and Tile work. (HSR 15.60)186.69Sqm
3838Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 16.1) TR407.13Sqm
3939Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge) (HSR 16.2) TR981.88Sqm
4040Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge) (HSR 16.3) TR981.88Sqm
4141Painting two coats with synthetic enamel Paint in all shades on old wood-work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.5) TR310.77Sqm
4242Applying priming coat with metal primer on New steel or iron work including preparation of surface. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.9) TR455.8Sqm
4343Painting two coats excluding priming coat with ready-mixed paint for metallic surfaces in all shades on new steel or iron work. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.17) TR941.24Sqm
4444Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces. (Note: - First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge) (HSR 16.25) TR7539.24Sqm
4545Distempering with washable oil bound distemper two coats on old distempered work (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.60) TR5700.9Sqm
4646Providing two coats of exterior acrylic emulsion paint. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (b) 1st Quality. (HSR 16.79 (b) TR7539.24Sqm
4747Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (Note:- reputed make Putty such as J.K./ Birla shall be used as approved by Engineer-in-charge). (HSR 16.81) TR5200.35Sqm
4848Cost of iron fittings, complete for doors and windows, such as tower bolts, handles, etc and screws for these fitting (excluding sliding bolt). (HSR 17.71)
4949for single lead shutter.106.63Sqm
5050for double leaf shutter.63.01Sqm
5151Factory manufactured panelled door or glazed and window shutters of commercial hard wood, such as hollock, champ, chikrassy and chaplash etc. (non coniferous timber other teak, conforming to IS specification No. 1003, kiln seasoned) with 100mm wide vertical styles, 150mm wide lock rail, 200mm wide bottom rail and 100mm wide other rails, with panels of 15 mm thick , tongued and grooved of commercial hard wood and including cost of iron hinges, screws, chocks/cleats, stops, nails etc., complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position). (b) 35mm thick. (HSR 17.90 (b) - Note 17.18 i)195.9Sqm
5252Factory manufactured wire gauze door and window shutters of commercial hard wood such as hollock, champ, chikrassy and chaplash etc. (non coniferous timber other teak, conforming to IS specification No. 1003, kiln seasoned) with 100mm wide vertical styles 150mm wide lock rail 200mm wide bottom rail and wire gauze of 140G or 120G designation including cost of iron hinges, screws, chock/cleats, stops nails etc., complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position) (styler and rails of windows shutters shall be 75mm wide). (b) 35mm thick. (HSR 17.92 (b) -Note 17.18 i)64.39Sqm
5353Factory manufactured solid flush door shutters, with block board core as per IS 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hot pressed, confirming to IS 2202 part I and II, fixed in position, including iron hinges, screws, chocks/ cleats and stops, etc (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position. (a) commercial veneering with vertical grains or corss bands and face veneer on both sides commercial facing with laminated core and lipped edges:- (iii) 35mm thick. (HSR 17.93 (a) (iii) - Note 17.18 i)164.87Sqm
5454Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12)48.03Qtl.
5555Supplying and fixing rolling shutters, of approved make, M.S. laths, interlocked together through their entire length, and jointed together, at the end, by end locks mounted on specially designed pipe shaft, with brackets, side guides 27.5 cm long wire spring grade no. 2 and arrangement for inside and out-side locking with push and pull operation complete, including top cover 0.80 mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed). (b) with 80 mm X 1.25 mm M.S. Laths. (HSR 18.18 b)4.18Sqm
5656Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights/ depths/ storeys/ basements etc. (HSR 18.22)\nNote:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps, Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.249.64Qtl.
5757Supplying and fixing glass panes including special metal sash putty of approved make. (b) Glass panes 4 mm thick, exceeding 40sq dm areas. (HSR 18.30 b)161.32Sqm
5858Pressed steel sheet frames (chowkats), consisting of 2 mm thick steel sheet of the specified section, including iron lugs (hold fasts), iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready-mixed paint red lead non-setting primer, of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:3:6 for lugs complete:- (HSR 18.34)
5959door and window frame of size 89mm x 50mm with 40mm wide single rebate.715.82Mtr
6060door and window frame size 127mm x 50mm with 40mm wide double rebate.1542.54Mtr
6161Recoverable items
6262Recovery items: -\nBidders have to quote rates for recovery items at least or more than reserve price.\nThe rate quoted against recovery items will not be included in the total amount rather it will be deducted while calculating financial statement of the agency.\nMaterial obtained from dismantling of structure have been calculated taking assumption that 80% of theoretical material will be retrieved. The dismantled material can used in any of the item for the work after modification (bringing it to required specifications) on approval from employer. In case it is not possible to use this material on the work, the agency can take away this material. The reserve price is as under: -
6363Brick @ Rs.4000/- per 1000 Nos.2802Nos.
6464Brick bats @ Rs. 500/- Cum5.84Cum
6565Tiles @ Rs.5000/- per 1000 Nos.29670Nos.
6666Tiles bats @ Rs. 500/- cum18.84Cum
6767Doors @ Rs.500/- each103Nos.
6868Windows @ Rs. 300/- each104Nos.
6969Ventilators @ Rs.200/- each158Nos.
7070Note: - All quantities of the above materials have been worked out on the basis of theoretical quantities. However, agency may visit site before quoting rates and assess the extent of retrieved material. There shall be no measurement and if material after dismantling is found on lesser side, no claim of agency on this score will be entertained and full recovery on the basis of quoted rate and quantity exhibited in the BOQ shall be made. The reserve rates are minimum rates to be used as base for quoting purchase rate by the agency. No rates below the reserve price will be entertained and reserve price will be considered for all purposes in case the agency quotes lesser than reserve price.
7171P.H. items
7272Providing Salt Glazed Stone, ware pipes grade \"A\" in standard length of 600mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in HSR item no. 29.38, 29.39, 29.40 including the cost of jointing materials as well as carriage, loading, unloading stacking, handing, re-handling etc. complete in all respect to the satisfaction of Engineer-in-Charge. (c) 200mm i/d. (HSR 29.95 (c)250.16Mtr.
7373Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:2 cement sand mortar over manhole inlcuding carriage loading, unloading, stacking handing re-handling etc. complete in all respect to the satisfaction of Engineer-in-charge. (a) Type: Extra havy duty set (EHD-35) 560mm clear opening. (HSR 29.94 (a)25Nos.
7474Constructing brick masonry inspection chamber sizes as given below upto 0.60 meters average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement RCC 1:2:4 slab 100mm thick/C.C. topping 50mm thick with 455mm x 455mm / 455mm x 610mm inside light duty C.I inspection chamber cover and frame weight as per I.S.I specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (c) Size 600 mm x 900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping). (HSR 29.84 (c)29Nos.
7575P/F in position HCI grating 150 mm x 150 for gully trap including painting with black bitumistic superior paint of approved manufacture three coats. (HSR 30.86)25Nos.
7676Providing & fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (b) 150mm dia PVC pipe 6 kg. pressure (Note:- Reputed make PVC Pipe such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. (HSR 13.89 (b)\nNote:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.250.16Mtr.
7777Providing and fixing PVC Bend ISI mark. (b) 150mm dia PVC Bend (Note:- Reputed make PVC Bend such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. (HSR 13.90 (b)\nNote:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.25Nos.
7878Providing & fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal Work - Exposed on Wall. (iii) 25 mm internal diameter of pipeline (DSR 18.10 (iii)85.34Mtr.
7979Providing and fixing in position best Indian make (to the approval of the Engineer-in-charge). Indian type Orissa or Orya water closet suite for Sinking into floor, with raised foot treads complete with 100mm H.C.I, ‘P’ Trap with or without vent as required and all other necessary fittings as fully described in item no.30.1 above. (a) Size 580mm. (i) White. (HSR 30.2 (a) (i)6Nos.
8080Providing and fixing in position best Indian make (as approved by the Engineer-in-charge) European type water closet suite, Syphonic type, Consisting of- (i) Vitreous chinaware Syphonic Suite with 15 litres capacity matching chinaware cistern and all internal brass fittings complete with ‘P’ or ‘S’ trap with or without vent (as approved by the Engineer-in-charge). (ii) One piece Seat and lid in hollow black or white plastic fitted with chromium plated hinges and rubber buffers, (to the approval of the Engineer-in-charge). complete in all respects including cutting and making good the walls and floors. (a) Single trap symphonic W.C. Suite. (i) White. (HSR 30.5 (a) (i)10Nos.
8181Providing and fixing in position of best quality stainless steel sink of 600mm x 450mm x 200mm size. (for estimating purpose only). (HSR 30.53)9Nos.
8282Providing and fixing in position 15mm i/d C.P brass bib Cocks of best quality (as required by the Engineer-in-charge). (a) Bib cock long body. (HSR 30.75 (a)20Nos.
8383Bib cock.16Nos.
8484Providing and fixing in position C.P brass stop cocks (as Approved by the Engineer-in-charge). (a) 15mm stop cock. (ii) Concealed stop cock with flange. (HSR 30.76 (a) (ii)34Nos.
8585Providing and fixing in position best Indian make flexible tube connection. (a) Aluminium. (i) 15mm x 300mm. (HSR 30.82 (a) (i)34Nos.

AI Tender Summary

OUR REF NO 27901822
AUTHORITY Government Departments
TENDER VALUE 91.89 Lakhs
LAST DATE 03-06-2021
Authority
Authority Name Public Works Department
Work Description Special Repair Of General Hospital At Meham In Rohtak District
Basic Detail
Tender No PWD/P2/216
Bidding Type Tender
Location
City Meham
State Haryana
Key Dates
Publish Date 13 May 2021
Submission Date 03 Jun 2021
Open Date 03 Jun 2021
Finance
Tender Value 91.89 Lakhs
Tender Fee 5000
EMD 1.84 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
A0B002EA-8F03-429C-9787-4878E556A29F.html
BOQ_228160.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 13, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 03, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 03, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

A0B002EA-8F03-429C-9787-4878E556A29F.html

xls

BOQ_228160.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender